Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹32.3 L+₹4.6 L (16.6%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹33.3 L+₹5.5 L (19.9%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹34.9 L+₹7.2 L (26.0%)Rejected-Finance FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹49.0 L
EMD Value
₹97,980
Closing Date
15 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KHADKI
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIR / MAINTENANCE OF VARIOUS CENTRAL /PACKAGE TYPE AC PLANTS AND ITS RELATED WORKS SUCH AS REPLACEMENT OF FILTERS, V BELTS, PULLIES AND CONTROLS AT 512 ABWS , CAFVD UNDER AGE E/M-II (C) IN GE (C ) KHADKI
2024_MES_638001_1
CWE/KKE/TOKEN-58 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KHADKI
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
GE CENTRAL KHADKI
₹97,980
Yes
30 Mar 2024
18 Jan 2024
23 Feb 2024
18 Jan 2024
15 Feb 2024
2 Feb 2024
19 Jan 2024 - 26 Jan 2024
Amount
S&F in repair CI Pot Strainer/ Y Stainer with matching flanges, gasket, hardware all as specified and directed of following sizes as per site requirment.
For 80 mm bore
For 100 mm bore
Disconnecting water connections to the condenser of package/central A/C plant of following capacity by dismantling the both end cover of condenser. Descaling the condenser of compressors with dilute sulphuric acid , flushing/cleaning with brush and water, re-fixing the side cover with new gasket nut / bolts and detect leakage complete all as specified and directed by Engineer -in-Charge. NOTE :- Dilute sulphuric acid for descaling is deemed to be included in the quoted rates.
For 5.5 TR
For 7.5 TR
For 12 TR
For 18 TR
For 20/22 TR
For 25/30TR
M&L for servicing/cleaning of FRP cooling tower of following capacity by dismantling top cover, fan with fan motor and removing the honey comb frills. Cleaning of base tray & frills, pot strainer etc. servicing of fan motor with changing of bearings and greesing refixing the fan, frill & top cover testing commissioning complete all as directed by Engr-in-charge. Note : Spares as required during the servicing and repairs as declared unservicable by Engr in charge shall be mesured and paid under relavant items of this schdule.
For 16 TR to 45 TR
For 50 TR to 100 TR
For 110 TR to 200 TR
Disconnecting/Isolating the compressor from the system by putting plates to the suction and discharge valve opening of the compressor. Dismatling the compressor completely by taking down the crank shaft. Removing unserviceable internal parts cleaning overhauling complete replacement of worn out parts such as suction reed, discharge reed, cylinder liners, loading/unloading system of compressor, washers, nut bolts, gaskets shaft seal, "O" rings, cutting, metalizing, grinding, balancing the crank shaft and reassembling the compressor including changing the compressor oil, leak testing with nitrogen, repairing leakages and charging R-22, gas, testing/comissioning complete for following compressor make Accel sabro/Kirloskar, complete all as directed by engineer in charge. Note : Spare parts , R-22 gas, compressor oil and nitrogen gas shall be measured and paid separately under respective items.
For SMC 8-65
For SMC 6-65
For SMC 4-65
For AC 470
S & F in replacement of following spares for compressor make :- Kirloskar/Accel / Sabro 8-65/6-65/4-65 model complete all as specified and as directed .
For Piston
For Piston ring
For Pisotn pin
For Shaft seal assembly
For Discharge valve reeds
For Loading Unloading Frame
For Main bearing Bush
For CR bearing
For Gasket set for 6-65
For Gasket set for 8-65
For Gasket set for 4-65
For Aluminium washer set
For Oil pump assembly
For Oil ring
For O Ring set
For Cylinder head cover
For Split pin
ForSunction valve reed
For Thrust collor
For Oil filter
For Cylinder liner
For Oil drain valve
For Bushing for connecting rod
For Crank shaft complete for SMC 6-65
For Crank Shaft for SMC 4-65
S&F in replacement of following spares for compressor of AC-470 (Make : Kirloskar) all as directed by Engr-in-charge.
For Connecting rod assembly
For Piston
For Piston ring
For Gudgeon Pin
For Shaft seal assembly
For Paper filter
For Sunction valve spring
For Discharge valve spring
For Gasket set
For O ring set
For Solenoid valve assembly
For Coil for solenoid valve
For Cylinder liner
For Oil drain valve
For Oil pump assembly
For Crank Shaft for AC - 470
For Filter with nut
For V.L.D Piston assembly
For Tal valve teflon set
For Oil pump bush
For Aluminium packing for cylinder liner
For Aluminium packing set
For Angle valve
Supply and filling nitrogen gas for leak testing of central & package A/C plants all as directed by Engr-in-charge.
Supply and filling of R-22 Gas in central & package A/C plants all as directed by Engr-in-charge
Supply and fillling compressor oil suitable to air conditioning plants compressor and taking out old dirty compressor oil, cleaning the crank case and oil filter complete all as specified and as directed.by Engr-in-charge.
S & F in replacement of defective brassomatic pressure relief valve of suitable size for 300 PSI refrigerent gas pressure complete all as specified and as directed.
Dismantling, Removing the unserviciable spares from A/C plant of any make & supply & fix new spares for A/C plant of following specifications all as directed by Engr-in-charge.
For HP/LP cutout MP 15R
For Oil Pressure Switch MP 55
For Teflone TAL- O Ring 50 & Tal 40
For Brass angle valve 1/4" for freon gas
For 1 1/8" Brass valve Teflone sheet
For Adaptor for valve 3/8" x 1/4"
S&F in replacement of over load relays type MN relay range 14-23 A complete all as specified and as directed.
S&F in replacement of over load relays type MN relay range 24-40 A complete all as specified and as directed .
S&F MCB 40 to 63 Amps, TP "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly including dismantling of old unsv MCBs/SFU fuse unit complete.
S&F MCB 100 Amps, TP "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly including dismantling of old unsv MCBs/SFU fuse unit complete all as specified and as directed.
S&F MCB 6 to 32 Amps, single pole and neutral, "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly including dismantling of old unsv MCBs/SFU fuse unit complete all as specified and as directed .
S&F MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly including dismantling of old unsv MCBs/SFU fuse unit complete all as specified and as directed .
S&F of MCCB 63 Amps 25KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and as directed .
S&F of MCCB 100 Amps 25KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and as directed .
S&F of MCCB 125 Amps 25KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specified and as directed .
S&F of MCCB 200 Amps 36KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete .
S&F of MCCB 250 Amps 36KA, FP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete. NOTE :- For item No 18.00 to 22.00 - (i) All cable connections should be done with supply and fixing suitable size lugs/thimble etc. (ii) Any addition / alteration to sheet metal enclosure existing panel for fixing of MCCBs and removal of old u/s switch gear is deemed to be included in the rates quated.
S&F in replacement of following spares for central AC plant ;-
For Indicating lamps RYB - 01 Set
For 'V ' belt of size / No C 105
For 'V ' belt of size / No B 85
For 'V ' belt of size / No B 108
For 'V ' belt of size / No C 156
For Power Contactors ML1.5
For Power Contactors ML2
For Power Contactors ML3
For Power Contactors MNX 18
ForPower Contactors MNX 22
For Power Contactors MNX 40
for Power Contactors MNX 50
For Power Contactors MNX 70
Labour only for detection of leakage and repairing of central type AC Plant of capacity 24 TR to 60 TR capacity by leak testing, leak repairing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results. NOTE :- Nitrogen gas and refrigerant will be measured and paid separately.
Dismantling of Air Handling Unit of any capacity with complete accessories such as cooling coil ,air filters,blower motor, blower / drum ,blower shaft,side panels , and wall opening if required etc including removing of electric connection and dismantling of pipe work of any size and type by using gas cutter or Electric cutter complete all as specified and directed .
Re-assembling/Refixing the complete Air Handling Unit of any capacity after carring out cleaning, servicing to cooling coil, blower & filters by using CTC solution including remetling ,fine grinding blower shaft and hardening balancing , realignment to AHU shaft, replacing unserviceable blower fins ,replacing bearings 2 Nos including inlet out let pipe welding,all electric connections and leak testing by using nitrozen gas and testing and commissioning all as specified and directed by Engr-in- Charge
S&F for Cast iron Sluice valves class PN 1.6 of size 100mm dia (4") incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valves complete all as specified and directed Engr-in-Charge.
S&F for Cast iron Sluice valves class PN 1.6 of size 80mm dia (3") incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valves complete all as specified and directed Engr-in-Charge.
S&F for thermostate expansion valve of suitable size for 22TR/30TR capacity air conditioning plants including taking down the unserviceble valve.
S&F for thermostate expansion valve of suitable size for 15TR capacity air conditioning plants including taking down the unserviceble valve.
S&F for thermostate expansion valve of suitable size for 7.5TR capacity air conditioning plant including taking down the unserviceble valve.
S&F for thermostate expansion valve of suitable size for 5TR capacity air conditioning plants. including taking down the unserviceble valve.
S&F for water pressure gauge 0-7 Kg/Sqm including taking down the unserviceble gauge.
S&F for refrgerant pressure gauge 30 to 150 PSI including taking down the unserviceble gauge.
S&F in replacement of pressure release valve of condensor 3/8" BSP threaded suitable for 300 PSI
S&F in replacement of DB/WB thermometer wall mounted with the facility of RH readings.
Taking down carefully and overhauling of Monoblock pump set by disconnecting the pump from foundation and pipe line, dismantling of shaft from the pump, replacing the unserviceable wornout bearing, gland packing, seal and bushing and assembling after repairs complete testing for the pump:-
For 7.5 HP to 10 HP
for 12.5 HP to 20 HP
M&L in replacement of 50mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
M&L in replacement of 40mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
M&L in replacement of 25mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
M& L in replacement of 20mm bore GI pipe medium grade incl all fitting and acessories complete all as directed.
S& F Gate Valves (Brass Insert) of 50 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
S&F Gate Valves (Brass Insert) of 40 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
S&F Gate Valves (Brass Insert) of 25 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
S&F Gate Valves (Brass Insert) of 20 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
S&Ffloat valve/ball type assemblt complete of size 20 mm size dia.
Painting of CI/GI/MS pipes of Air / Water distribution of size 100/80 mm dia along with side supports complete with two coats of synthetic enamel paint all as per colour code directed by Engr-in-Charge.
M&L painting to cooling tower inside and outside with one coat of primer and one coats of epoxy paint of approved colour including scapping out the old paint complete all as specified and and directed by Engr-In-charge.
M&L for painting of storage tank with one coat of primer and one coats of synthetic enamel paint approved colour including scapping out the old paint complete all as specified and directed by Engr-In-charge.
M&L for mild steel brackets, frames ,supports, channels and stands of type as required at site made out of angle iron, flat or strip of grade Fe-410-S of any size as per site requirement for PGI air duct etc complete all as specified and as directed by Engr-in-charge .
S& F double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 630 x 500 x 50mm.
S& F double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 630 x 400 x 50mm.
S&F double nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 610 x 610 x150mm.
Material and Labour for for Copper piping 5/8" (18/20 gauges) with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds.
Material and Labour for for Copper piping 1/2" with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds or frame etc.
Material and Labour for for Copper piping 1/4" with necessary fitting such as elbow bends sockets and tee's , clamps and supports on wall and grounds.
Supply, laying, commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 70 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed.
Supply , laying, commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 35 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed.
Supply, laying, commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 25 Sqmm 3.5 core incl removing unserviceable/old cable complete all as specified and as directed.
Supply, laying, commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 16 Sqmm 4 core incl removing unserviceable/old cable complete all as specified and as directed.
Supply , laying, commissioning and testing XLPE insulated ,armoured heavy duty electric cable Aluminium conductor, 1100 volt cross sectional area 6 Sqmm 4 core incl removing unserviceable/old cable complete all as specified and as directed.
M&L for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 7.5 HP to 12.5 HP complete all as specified and as directed.
M&L for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 15 HP to 20 HP all as specified and directed.
M& L for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including material such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 30 HP to 40 HP complete all as specified and as directed.
Disconnection and taking out old defective Hermetically reciprocating sealed compressor unit as required of pakage AC plants and M&L for fixing new compressor (new sealed unit only) sealed unit by means of nut bolt & washer with antivibrating bush/ pad and brazing work, pressure testing for leakage,vaccumising etc of capacity 3 TR for pakage AC plants of the existing .
Disconnection and taking out old defective Hermetically reciprocating sealed compresso as required of pakage AC plants and M&L for fixing new compressor (new sealed unit only) sealed unit by means of nut bolt & washer with antivibrating bush/ pad and brazing work, pressure testing for leakage, vaccumnsing etc of capacity 5 TR for pakage AC plants of the existing.
M&L for robotic duct cleaning of AC PLANT ,opening of duct to insert robot along with cleaning equipment & its accesories, Washing & cleaning of supply & return air diffuser ,cleaning & washing of grills, damper cleaning, sanitization of duct and AHU and packing of complete floor area. also contractor should provide photos and video of before cleaning and after cleaning to the department complete all as specified & directed by Eng-in-Charge.
Demolition of cement concrete in ground floors and paving n exc 15 cm thickness ( below or above ground level) all as specified and directed.
M&L for cement concrete 1:2:4 type B-2 ( using 40 mm graded agg) as in sub base for stone sett paving complete all as specified and directed upto 150 mm thick
M&L for PCC Surface preperationby cleaning the surface from any moisture of dirt,wax grease, flux residue and all other contaminaints applying two coats of AS 2045 Epoxy primer on PCC Surface, supplying and applying two components dielectric coating on the prepared surface having electric strength not less than 32.2 KV/MM, Dielectric dissipation not less than 0.074,dielectric constant not less than 10.93K, flash point above 52 degree celcius, a film of thickness 3 mm is a achieved. Note:-(a) The Contractor has to produce a certificate from Govt approved lab certifying all thecharacteristic and properties of coating as stated above. (b) the Contractor has to produced the test reportings of the coatingsapplied at the locationto the complete statisfaction of Eng-in-Charge.(c) The coated rate is deemed to be inclusive of material required for surface preperation Complete all as specified and as directed by Engr-in-Charge at site.
BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS
SHAILENDRA B TULSANI
Chaulya Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .