| 1 | | Erection of metallic pole of following length in cement concrete 1/3/6 (1 cement, 3 coarse sand ,6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required - Above 4.5 metre and upto 6.5 metre | 8 | each | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |
| 2 | | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required-32mm Dia | 32 | Mtr | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |
| 3 | | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (For Road Crossing) - Upto 35 sq. mm | 220 | Mtr | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |
| 4 | | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required - Upto 35 sq. mm (clamped with 1mm thick saddle ) | 160 | Mtr | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |
| 5 | | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 4 X 25 sq. mm (28mm) | 32 | Set | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |
| 6 | | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required - Single pole (Inside the Pole Loop Box) | 8 | each | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |
| 7 | | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (Grp. C) | 6 | Point | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |
| 8 | | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2.5sqmm x 3 | 120 | Meter | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |
| 9 | | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 6 sqmm x 3 | 30 | Meter | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |
| 10 | | Supplying and fixing following way, SPN, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12 way, Double door | 1 | each | Manish Pal 781021,ESIC Regional Office Bamunimaidan, Guwahati | 75 |