Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹3.6 L
Closing Date
22 Jun 2026, 12:00 pmClosed
Extension of OPD complex to accommodate (a) Medical Store (b) Physiotherapy department at Eastern Railway Hospital, Liluah by constructing one G+1 building on the south side of extended OPD.
Engg-OPDEXTN-25-26-LLH-R~ER
Engg-OPDEXTN-25-26-LLH-R
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹3.6 L
22 Jun 2026
29 May 2026
8 Jun 2026
I-Cable & Cable Laying for Electrical Works (Including all taxes and charges)
Supply of ISI marked Aluminium Cable Twin Core 6 Sq.mm Weather proof Unarmoured PVC Insulated ,PVC 1 Sheathed Cable with Aluminium Conductor for working Voltage up to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f IS:8130/1984 Reaffirmed 2005 Make: Gloster, Havells, Polycab, KEI or equilavent) (S= 81.37, L= 0.00)
Supply of LT XLPE insulated, PVC outer sheathed, non-magnetic galvanized steel strip armoured, stranded 2 compact circular Aluminium conductor Cable of size 4 core x 10 sq.mm, nominal system Voltage 1100V grade and highest system voltage 1210V confor- ming to IS 7098 ( Part I - 1988 ) with amendment number 1 and 2 and 3 Reaffirmed 2005. ( Make of cable -Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab) (S= 144.66, L= 0.00)
Supply of LT XLPE insulated, PVC outer sheathed, non-magnetic galvanized steel strip armoured, stranded 3 compact circular Aluminium conductor Cable of size 4 core x 50 sq.mm, nominal system Voltage 1100V grade and highest system voltage 1210V conforming to IS 7098 ( Part I - 1988 ) with amendment number 1 and 2 and 3 Reaffirmed 2005. ( Make of cable -Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab) (S= 369.35, L= 0.00)
Supply of LT XLPE insulated, PVC outer sheathed, non-magnetic galvanized steel strip armoured, stranded 4 compact circular Aluminium conductor Cable of size 4 core x 120 sq.mm, nominal system Voltage 1100V grade and highest system voltage 1210V conforming to IS 7098 ( Part I - 1988 ) with amendment number 1 and 2 and 3 Reaffirmed 2005. ( Make of cable -Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab) (S= 761.02, L= 0.00)
Laying, jointing, connection, testing & commissioning of LT cable 1100V grade of small size (Upto 95 sq mm ) along the wall by necessary clamping arrangement or concealed including making good of wall including socketing and termination with epoxy end jointing where necessary (clamps should be made of 50mmx 6mm MS flat). (S= 69.47, L= 0.00)
Laying, jointing, connection,testing & commissioning of LTcable 1100V grade of higher size(above 95 sq.mm.) along the wall/catenary or garder truss by necessary clamping arrangement including socketing and termination with epoxy end jointing where necessary (clamp should be made of 50 mm x 6 mm M.S. Flat) (S= 137.32, L= 0.00)
Cutting of concrete and trenching drawing laying and jointing of the 1100V grade cable through 7 underground as per CEE's drawing no.E4/GPST/033/87 and refilling the trench after laying the cable including making good the damages and then smooth flooring and re-concreting (18" wide xmin 3' deep) with cement, sand,& stone chips inratio 1:2:4 and connection with switcher gear along with supply of suitable size gland, socket etc. as required. (S= 471. 60 L= 0.00)
Trenching drawing laying and jointing ofthe 1100 V grade cable through under groundas per CEE's drawing no. E4/GPST/033/ 87and refilling the trench after laying the cable including making good the damages and connection with switch gears along with supply of suitable size gland, socket, cable jointing kits etc.) (S= 123.57, L= 0.00) Unit
A1-Non-schedule items or Non-DSR items "(Civil part)
Design & supply of detailed GAD, structural and architectural drawings of "Extension of OPD complex to 1 accommodate (a) Medical Store (b) Physiotherapy department at Eastern Railway Hospital, Liluah by constructing one G+1 building on the south side of extended OPD" including foundation, column, roof, etc. Complete in all respect as per instruction of Engineer-in-charge. Whenever required design & drawing of suitable type of foundation shall be given. The rate includes supply print out of all required drawings on tracing paper with 05copies of colour print, 01 copy of RTF, design booklet/report(s) in 03 set and one soft copy on pendrive. Design & drawings shall be tecnically vatted from Govt. Engineering college or any other reputed institution as per direction of Engineer-in-charge. The design & drawing should be prepared on the basis of relevant I.S. Code. Rate is Approx. 1% of total sum of Sch. B1 & Sch. B2
Preparation and submission of Final report of soil test giving complete and comprehensive record of investigations, laboratory test reports and calculations in approved format. Unit
A2-GST @ 18% on Schedule A1 (Civil part)
B1-As per CPWD's DSR- 2023 (Civil part)
B2-As per USSOR-2021 items(Civil part)
Hiring of machinery for minor miscellaneous works for short duration including operator/driver, fuel, 1 lubricants and consumable. The contractor shall arrange all statutory permits as required by rules and regulations prevailing in the area of work. Payment shall be made for actual working hours at site. JCB Backhoe Loaders 3DX Plus or similar with minimum 1.10 cum bucket capacity
Exploratory drilling of boreholes down to required depth, drilling of 150mm dia. boreholes in all type of soils 2 except hard rock & large boulders (boulder core more than 30cm) including refilling, reinstating surface and disposing off surplus material including use of mechanical rigs with power operated winches as well as percussion/chiselling tool for advancing through occasional seams of hard strata to be employed, where necessary in Dry area. 0m to 10m
Taking out 100mm dia. & 450mm long disturbed samples of soil from bore holes, including provision of air tight containers for packing, labeling and transporting the samples to laboratory. Samples shall be collected as per IS:2720.
Conducting standard penetration test as per IS:2131 at approximate1.5m intervals in bore holes, as directed by the Engineer in charge
Collection of water samples at required intervals
Conducting laboratory Tests on collected soil samples as per relevant IS code Moisture Content/Dry Density
Conducting laboratory Tests on collected soil samples as per relevant IS code Atterberg Limits
Conducting laboratory Tests on collected soil samples as per relevant IS code Specific Gravity
Conducting laboratory Tests on collected soil samples as per relevant IS code Grain size analysis including Hydrometer analysis
Conducting laboratory Tests on collected soil samples as per relevant IS code Direct Shear Test
Conducting laboratory Tests on collected soil samples as per relevant IS code Natural Density
Conducting laboratory Tests on collected soil samples as per relevant IS code Consolidation Test
Conducting laboratory Tests on collected soil samples as per relevant IS code Unconfined Compression Test
Conducting laboratory Tests on collected soil samples as per relevant IS code Tri-axial Test
Conducting chemical analysis of ground water samples to determine suitability for concreting and aggressiveness in relation to attack on concrete / reinforcement including determination of pH value.
Conducting chemical analysis of soil samples to determine aggressiveness in relation to attack on concrete / reinforcement including determination of pH value Unit
B3-GST @ 6% on Schedule B2(Civil part)
II-General Electrical Works for Electrical Works (Including all taxes and charges)
Supply of TPN MCB DB (Heavy duty, Outdoor type, UV ray protected,self fire-extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT,shock resistance IK10 (20 Joules ) and IP65 degree of protection grade transparent DB box, similar to ABB Mistral 65 - 20 Modules or equivalent ), 3Ph, 50Hz,415V, 4 way per phase,415V, 50Hz, 1 complete with total 12 nos. SPMCB of current rating from 6A to 32A, 10 kA,240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10kA, 415V, 50Hz, Suitable for AC + Pulsating DC(Type A) + Harmonics Make of MCB and Metal Distribution Board - L & T Switchgear (Lauritz Knudsen) / Siemens / ABB / Legrand / Schneider / C&S. (MCBs should confirm to IS/IEC 60898-1 or latest & 60947-2 or latest ) (TPN DB should confirm to IEC 61439-1&3 & IS 8623 -1&3 or latest with CRCE sheet steel,RAL9003,powder coated) (S= 19377.06, L= 0.00)
Fixing , installation ,testing and commissioning of above TPN MCB DB with suitable arrangement. (S= 0.00, L= 167.48)
Supply of SPN DB ( Metal Enclosure with Metal Door ), 10 way, 1Ph,240V, 50Hz, complete with 6 nos. SP MCB of current rating from 6A to32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 3 40A,300mA, 10kA, 230V,50Hz ( Make of MCB, RCBO and Metal Distribution Board - L & T Switchgear (Lauritz Knudsen) / Siemens/ ABB / Legrand / Schneider/ C&S) (MCBs should confirm to IS/IEC 60898-1 or latest & 60947-2 or latest )(RCBO should confirm to IS 12640-2 /IEC 61009-1 or latest) (SPN DB should confirm to IEC 61439-1&3 & IS 8623 -1&3 or latest with CRCE sheet steel,RAL9003,powder coated) (S= 8083.81, L= 0.00)
Fixing , installation ,testing and commissioning of above SPN MCB DB with suitable arrangement. (S= 0.00, L= 132.98)
Supply and installation of GI flat of 50 mm x 6 mm or GI Wire (6 SWG) for earthing arrangement of transformer, HT & LT panel and connection with earth pipe (GI Flat/ Wire to be decided by the EIC) from wall by Gl nut-bolts and washer with support. (S= 97.87, L= 0.00)
Supply of Dust and vermin proof metal Busbar Chamber fabricated using sheet steel (CRCA) of 16 SWG ( 1.6mm ) thickness and epoxy powder coated consisting of 4nos. tinned copper busbar of each bar of capacity 200 Amp, 6/8 6 way, suitable for 415V,50Hz , 25KA Short Circuit withstand Capacity(1Sec.,KA) supply system including all accessories along with fixing,connection, testing and commissioning of incoming and outgoing cables glanding, cable socketing and connection with all suitable arrangement. (similar to Havells cat, No.: IHBB020006 /IHBB020008) ( Make -Havells /Indo- Asian/ Standard / HPL/ C&S / LK (L&T)) (S= 10704. 62, L= 0.00)
Conceal wiring onwall/ceiling/floor throughPVC pipe of suitable diameter for Main line by two nos. single core,HRFR / FRLSH grade, PVC insulated, copper conductor cable of size 6.0 sq.mm., 1100V grade for phase and neutral along with one no. single core, HRFR / FRLSH grade,PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable,GI concealed box with modular cover plate, PVC pipe and all other associated work along with make good of wall surface as its original condition. (Make of Copper conductor wire - Anchor / Havells /Finolex / Gloster / KEI /Polycab / RR Kabel ) (Make of Modular switch,socket, box, cover plate etc. - ABB / Anchor (Panasonic ) / Havells (Crabtree ) / Legrand / LK(L&T) , North West , Schneider , C&S )(S= 151. 60, L= 0.00)
Conceal wiring onwall/ceiling/floor through PVC pipe of suitable diameter for Submain by two nos. single core,HRFR / FRLSH grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for phase and neutral 8 along with one no. single core HRFR / FRLSH grade,PVC insulated, copper conductor cable of size 2.5 sq.mm., 1100V grade for Earth Continuity conductor including supply of cable, GI concealed box with modular cover plate, PVC pipe and all other associated work along with make good of wall surface as its original condition. (Make of Copper conductor wire -Anchor / Havells /Finolex / Gloster / KEI /Polycab / RR Kabel ) (Make of Modular switch,socket, box, cover plate etc. - ABB / Anchor (Panasonic ) / Havells (Crabtree ) / Legrand / LK(L&T) , North West , Schneider , C&S ) (S= 104.50, L= 0.00)
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Light point /Fan point / Call Bell point/ Indication point / Glow Sign point by two nos.single core, HRFR / FRLSH grade, PVC insulated,copper conductor cable of size 1.5 sq.mm,1100V grade for phase and neutral along with one no. single core,HRFR / FRLSH grade, PVC insulated, 9 copper conductor cable of size1.5 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable,GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch,ceiling rose and all other associated work along with make good of wall surface as its original condition. (Make of Copper conductor wire -Anchor / Havells /Finolex / Gloster / KEI /Polycab / RR Kabel ) (Make of Modular switch,socket, box, cover plate etc. - ABB / Anchor (Panasonic ) / Havells (Crabtree ) / Legrand / LK(L&T) , North West , Schneider , C&S )(S= 368.05, L= 0.00)
Conceal wiring onwall/ceiling/floor through PVC pipe of suitable diameter for 6A/5 pin plug point by two nos. single core, HRFR / FRLSH grade, PVC insulated,copper conductor cable of size 1.5 sq.mm,1100V grade for phase and neutral along with one no. single core,HRFR / FRLSH grade, PVC insulated, copper onductor cable of size1.5 sq.mm., 1100V 10 grade for Earth Continuity Conductor ( ECC )including supply of cable,GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch,modular plug socket and all other associated work along with make good of wall surface as its original condition. (Make of Copper conductor wire -Anchor / Havells /Finolex / Gloster / KEI /Polycab / RR Kabel ) (Make of Modular switch,socket, box, cover plate etc. - ABB / Anchor (Panasonic ) / Havells (Crabtree ) / Legrand / LK(L&T) , North West , Schneider , C&S) (S= 255.49, L= 0.00)
Conceal wiring on wall /ceiling / floor through PVC pipe of suitable diameter for 16A/6 pin plug point by two nos.single core, HRFR / FRLSH grade, PVC insulated,copper conductor cable of size 4.0 sq.mm.,1100V grade for phase and neutral along with one no. single core,HRFR / FRLSH grade, PVC insulated, copper conductor cable of size1.5 sq.mm., 1100V 11 grade for Earth Continuity Conductor ( ECC ) including supply of cable,GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch,modular plug socket and all other associated work along with make good of wall surface as its original condition. (Make of Copper conductor wire -Anchor / Havells /Finolex / Gloster / KEI /Polycab / RR Kabel ) (Make of Modular switch,socket, box, cover plate etc. - ABB / Anchor (Panasonic ) / Havells (Crabtree ) / Legrand / LK(L&T) , North West , Schneider , C&S) (S= 467.02, L= 0.00)
"Supply and fixing of Mobile Charging points with hylam sheet cover consisting of a) Plug Socket 5Pin/6Amp. - 3nos. b) Piano Switch 6Amp - 3 nos. c) MCB SP6Amp, B/cap10KA. - 1 no.d) LED indication lamp -1no, including wiring with 2.5 mm 2 single core, multistrand, PVC FRLS Cu wire through suitable size (ISImarked) PVC conduit pipe/casing/ concealed 12 way and along with copper ECC of size 1.5 mm2 as per general specification. (PVC wire Make:Havells/Gloster/Polycab/RRKabel/KEI/Mescab) (Switch & Plug SocketMake: Roma/ Panasonic/Anchor/ GM Modular/Legrand/ Havells)(Switchgear Make:Siemens/ ABB/ Schneider/Lauritz Knudsen/ C&S/Havells/ Legrand)" (Make of Copper conductor wire -Anchor / Havells /Finolex / Gloster / KEI /Polycab / RR Kabel ) (Make of Modular switch,socket, box, cover plate etc. - ABB / Anchor (Panasonic ) / Havells (Crabtree ) / Legrand / LK(L&T) , North West , Schneider , C&S) (S= 1174.43, L= 0.00)
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for modular type Multi plug board/computer board with modular type switches, sockets and boards consisting of the following: i) 03 nos. 6 Amp switch (ISI marked), ii) 03 nos.6 Amp shuttered plug socket (ISI marked), iii) 01 no. 16Amp switch (ISI marked), iv)01 no. 16 Amp shuttered plug socket (ISI marked), v) 01 no.16 Amp MCB, vi) 01 no.Indicator.( Red ) by two nos. single core, HRFR / FRLSH 13 grade,PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for phase and neutral along with one no.single core, HRFR / FRLSH grade, PVC insulated,copper conductor cable of size 2.5 sq.mm.,1100V grade for Earth Conti- nuity Conductor (ECC ) including supply of cable, GI concealed box with modular cover plate,PVC pipe, 'junction /circular box, modular switch, modular plug socket and all other associated work along with make good of wall surface as its original condition. (Make of Copper conductor wire -Anchor / Havells /Finolex / Gloster / KEI /Polycab / RR Kabel ) (Make of Modular switch,socket, box, cover plate etc. - ABB / Anchor (Panasonic ) / Havells (Crabtree ) / Legrand / LK(L&T) , North West , Schneider , C&S) (S= 1373.00, L= 0.00)
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Window AC/Split AC/ Water Cooler by two nos. single core,HRFR / FRLSH grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral along with one no. single core, HRFR / FRLSH grade,PVC insulated, copper conductor cable of size 2.5 14 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC )including supply of cable,GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch,ceiling rose and all other associated work along with make good of wall surface as its original condition. (Make of Copper conductor wire -Anchor / Havells /Finolex / Gloster / KEI /Polycab / RR Kabel ) (Make of Modular switch,socket, box, cover plate etc. - ABB / Anchor (Panasonic ) / Havells (Crabtree ) / Legrand / LK(L&T) , North West , Schneider , C&S) (S= 1175.42, L= 0.00)
Supply of outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch,25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 25-35 sq. mm and outgoing 16 &2.5 sq. mm terminals. (63A TPN MCB MADE BY HAVELLS,STANDARD, C&S , 15 SIEMENS ).N.B.-(i) Inclusive of supply and fitment of all outgoing cable.However supply , laying & fitment of incoming cable scope is given inseperate items) (ii) Foundation with M-25 grade concrete with adequate height. Make:Havells/Gloster/Polycab/RRKabel/KEI/Mescab)(Switch & Plug Socket Make: Roma/ Panasonic/Anchor/ GM Modular/Legrand/ Havells)(Switchgear Make:Siemens/ ABB/ Schneider/Lauritz Knudsen/ C&S/Havells/ Legrand)" (S= 20578.09, L= 0.00)
Supply , installation ,testing & commissioning of 2 Ton 5 Star BEE Rating (ISEER value from>=5 to <=5.5) Inverter AC (Variable Speed) High Wall Split AC, Eco friendly refrigent ,with Remote,Outdoor unit mounting Stand and 16 minimum 3 Meter length of copper pipe and suitable connecting electrical cable for installation and commissioning as per IS 1391 latest part 2 for room Air conditioners(Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687797303630 dt.11/06/2025) ( Make Voltas, Carrier,Hitachi,Blue Star, O'General,Llyod, Daikin) (S= 47911.18, L= 0.00)
Supply , installation ,testing & commissioning of 1.5 Ton 5 Star BEE Rating (ISEER value from>=5 to <=5.5) Inverter AC (Variable Speed) High Wall Split AC, Eco friendly refrigent ,with Remote,Outdoor unit mounting Stand and 17 minimum 3 Meter length of copper pipe and suitable connecting electrical cable for installation and commissioning as per IS 1391 latest part 2 for room air conditioners(Detailed Description/Specification as per Product # 1 of GeM contract No. GEMC-511687755848252 dated 13/06/25) ( Make Voltas, Carrier,Hitachi,Blue Star, O'General,Llyod, Daikin) (S= 43669.70, L= 0.00)
Supply of Drainage system for each above Split AC machines for discharge of condensate water with all accessories by 1.5 inch dia PVC pipeand drain line of each machine connected by 0.5 inch cotton braided PVC flexible pipe with all other accessories along with fitment and commissioning. (S= 122.97, L= 0.00)
Supply of basic material to construct unit maintenance free earth as per RDSO specs NO.RDSO/SPN/197 Ver. 1.0 or latest and conforming to RDSO Drg No. SDP/RDSO/E&B/001 or latest.Necessary testing Certificate of UL,IEC to be produced. [Numbers = Lot] (S= 15760.07, L= 0.00)
Installation of unit maintenance free earth as supplied in above item. The installation of this item shall be carried out by the contractor as per RDSOSpecs. No. RDSO/SPN/197 Ver. 1.0 or latest and conforming to RDSO Drg No. SDO/RDSO/E&B/001 or latest. (S= 0.00, L= 5287.77)
Supply, installation , testing & commissioning of 400 mm sweep,1ph. bracket type wall mounted fan with suitable clamping arrangement. (Make - Havells/Usha/Anchor/Orient/Bajaj/Crompton/EPC) (S= 1904.20, L= 0.00)
Supply of A.C. Exhaust Fan, 300 mm sweep, 230V,50 c/s complete with louver and shutter and all accessories . (Make - Havells/Usha/Anchor/Orient/Bajaj/Crompton/EPC) (S= 1367.02, L= 0.00)
Supply of AC Metallic Exhaust Fan, 225 -230 mm sweep,230V, 50 c/s complete with all accessories . (Make - Havells/Usha/Anchor/Orient/Bajaj/Crompton/EPC) (S= 1623.43, L= 0.00)
Supply of Plastic Ventination Fan, 200 mm sweep,230V, complete with all accessories . (Make - Havells/Usha/Anchor/Orient/Bajaj/Crompton/EPC) (S= 1279.92, L= 0.00)
Fixing, connection & commissioning of Exhaust/Ventilation fan with G. I. clamps made of G. I. flat of suitable size & G. I. Nut, Bolts including necessary Massonary works. (S= 0.00, L= 305.47)
Supply of ISI marked Storage Water Heater 5 star rated of capacity 25 Ltrs suitable for operation on 1Ph,220-250V, 50Hz supply system including all accessories. ( Make :Bajaj / Venus / Crompton). (S= 5937.43, L= 0.00)
Installation, connection and commissioning of storage water heater with GI clamps made of GI flat of suitable size & GI nut- bolts. (S= 0.00, L= 229.37)
Supply of UV based Aquaguard Storage Water Cooler cum Purifier of Cap.120 Ltrs. (approx) for operation on 230V., A.C. 50 c/s complete with all accessories. (Make: Eureka Forbes/BlueStar/Voltas/Usha) (S= 107790.41, L= 0.00)
Fixing, connection & commissioning of above Storage Water Cooler cum Purifier with G. I. clamps made of G. I. flat of suitable size & G. I. Nut, Bolts including necessary Massonary works. (S= 0.00, L= 2679.09)
Supply of BLDC ceiling fan of sweep 1400 mm, air delivery range from 245 cubic meter per minute to 272 cubic meter per minute and input power consumption range from 33W to 36W (Star rating - 5 star, Class of insulation- 'F' 30 ,service value -7.4 & above cubic meter per minute per watt) with remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system (Confirm to all the performance requirements laid down in IS 374:2019 or latest, including all amendments, as applicable) with 60 months warranty. (BLDC Ceiling Fan Make - :Atomberg /Havells / Usha / Orient / Crompton / Bajaj/ Halonix) (S= 2480.64, L= 0.00)
Supply of 3.0 ft Down rod made of heavy gauge GI pipe of size 20 mm dia for suspension of ceiling fan including GI clamps made of GI flat of suitable size and GI nut bolts for hanging of MS down road from ceiling. (S= 85.92, L= 0.00)
Fixing, connection and commissioning of new BLDC ceiling fan by GI clamps made of GI flat of suitable size and GI nut-bolts along with down road arrangements (as per site condition) including transportation from site to stores. (S= 58.86, L= 0.00)
Supply of LT Wall Mounted/ Floor Mounted Double Door Cubical Outdoor type Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder comprising with the following items for 150 KVA to 180 KVA Load :- a) MCCB, 4 Pole,( 200 )Amp, 415V,50Hz, 36kA, ( Ics =100% Icu )Microprocessor based release similar to iTRP1 type of LK (L&T)-make or equivalent with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt Instantaneous protection, 4) Provision of Thermal Memory, 5) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication - 2 nos. b)MCCB, 4 Pole, ( 100 )Amp, 415V, 50Hz, 36kA,( Ics = 100% Icu ) Microprocessor based release similar to iTRP1 type of LK (L&T)-make or equivalent with above mentioned features - 2nos. c) MCCB, 4 Pole,63 Amp, 415V, 50Hz,36kA,( Ics = 100% Icu ) Microprocessor based release similar to iTRP1 type of LK (L&T)-make or equivalent with above mentioned features - 4nos. d) Tinned Copper Busbar (4 Bar) each of capacity 400 Amps., 415V, 50 Hz.- 1 set. e) Static Multifunction panel mounting LED Energy Meter suitable for Interrupts, THD, Events (High-Low ), Neutral Current, K Factor - 8nos. f) CT of suitable ratio for MFM - 24 nos. g) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF &TRIP" indication for all incoming and outgoing feeders - suitable nos. h) Petty Store for control cable,MCBs, gland, socket, fuse, push button, TNC switch, selector switch,rotary handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release,terminal blocks & NO/NC relays etc. - 1 job. i)Fabrication work for above panel including internal wiring - 1 job. (Make - LK (L&T) /Siemens / ABB / /Legrand / Schneider / C&S ) ( Make for Energy Meter - ABB/Fluke/HTC/Kaycee/Secure /LK (L&T) / Motwane/Schneider/Siemens/C&S ) peration on 3Ph, 415V,50Hz supply, Cl 1 with provision of RS-485 communication port having display parameters - V, A, F, PF,kW, kVA, kVAR, kWh,kVAh, kVARh, Run hours,On hours, Phase angle,Interrupts, THD, Events (High-Low ), Neutral Current, K Factor - 8 nos. h) CT of suitable ratio for MFM - 24 nos. i)LED indication lamp for 3-Phases for incoming feeders and "ON, OFF &TRIP" indication for all incoming and outgoing feeders - suitable nos. j) Petty Store for control cable,MCBs, gland, socket,fuse, push button, TNC switch, selector switch,rotary handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release,terminal blocks & NO/NC relays etc. - 1 job. k)Fabrication work for above panel including internal wiring - 1 job. (Make - LK (L&T) /Siemens / ABB / Hager /Legrand / Schneider /BCH / C&S )( Make for Energy Meter - ABB/Fluke/HTC/Kaycee/Secure /LK (L&T) / Motwane/Schneider/Siemens/C&S) (S= 254776. 34, L= 0.00) Unit
III-LED Luminaires for Electrical Works (Including all taxes and charges)
Supply of Wall mounted 7W LED luminaire with flexible neck for adjusting beam for mirror top light with 1 inbuilt driver similar to Philips Indoor Wall light Model No.-919215850797 or equivalent including all other accessories. TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 80 FOR LED SOURCE. ( Make: Philips (Signify) / Havells / Crompton / Bajaj/ Panasonic / Orient) (S= 2397.32, L= 0.00)
Supply,eraction,fixing and connection of 9 watt LED Bulb complete with holder and all other accessories for eraction of the same TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 80 FOR LED SOURCE. ( Make: Philips (Signify) / Havells / Crompton / Bajaj/ Panasonic / Orient) (S= 103.54, L= 0.00)
Supply, fixing, connection, testing and commissioning of indoor type, surface mounted 18-20 Watt integrated batton LED fittings with BIS certified driver and luminare, operating voltage of 150-270 Volt industrial grade constant current driver (minimum driver efficiency of 85%), ingress protection of IP20 (or better), impact protection of IKO3 (or 3 better), minimum system lumen efficacy of 120Lm/W (or higher), LED life of 50000 burning hours (or greater), aluminium housing, color temperature of 6500K, CRI>=80, THD<=20%, PF>=0.90, SPD> 4KV, LM 79 Report shall be provided from manufactures own NABL Lab with all accessories for erection of the same.( (LED make - Nichia,Osram, Seoul, ,Lumileds, Avago, Cree ) TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE SHALL BE PROVIDED FROM MANUFACTURES OWN NABL LAB , LM 80 FOR LED SOURCE,T21 PROJECTION REPORT,LUMINAIRE & LED DRIVER TYPE TEST CERTIFICATES. ( Make: Philips (Signify) / Havells / Crompton / Bajaj/ Panasonic / Orient) (S= 463.65, L= 0.00)
Supply ,Fixing ,connection ,testing and commissioning of Recess Downlighter 15 Watt LED light fitting with Flicker controlledtechnology (Orient Electric Modelno.- LDRER-15-C-V2-FC orequlivant) (LED make - Nichia,Osram, Seoul, 4 Lumileds, Avago, Cree ) DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; DRIVER PERFORMANCE REQUIREMENTS: IS 16104, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE SHALL BE PROVIDED FROM MANUFACTURES OWN NABL LAB , LM 80 FOR LED SOURCE,T21 PROJECTION REPORT,LUMINAIRE & LED DRIVER TYPE TEST CERTIFICATES. ( Make: Philips (Signify) / Havells / Crompton / Bajaj/ Panasonic / Orient) (S= 781.03, L= 0.00)
Supply ,Fixing ,connection , testing and commissioning of 2ft x 2ft Recess mounted 36 Watt LED light fitting with flicker controlled technology (Orient Electric Model no.- LTRAQ-36-C-FC or equlivant) (LED make - Nichia,Osram, Seoul, 5 Lumileds, Avago, Cree ) DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; DRIVER PERFORMANCE REQUIREMENTS: IS 16104, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE SHALL BE PROVIDED FROM MANUFACTURES OWN NABL LAB , LM 80 FOR LED SOURCE,T21 PROJECTION REPORT,LUMINAIRE & LED DRIVER TYPE TEST CERTIFICATES. ( Make: Philips (Signify) / Havells / Crompton / Bajaj/ Panasonic / Orient) (S= 1729.49, L= 0.00)
Supply, fixing, connection, testing and commissioning of out door type 40-45 Watt LED street light luminaries with BIS certified driver and luminare, operating voltage of 140-270 Volt having industrial grade constant current driver (minimum driver efficiency of 85%), (LED make - Nichia,Osram, Seoul, Lumileds, Avago, Cree ) complete with all accessories,ingress protection of IP66 (or better), impact protection of IKO7 (or better), minimum system lumen efficacy of 130Lm/W (or higher), LED life of 50000 burning hours (or greater), pressure die cast aluminium housing, color temperature 6 of 5700K, CRI>=70, THD<=20%, PF> 0.95, SPD>=10KV with Life span of LED chip - Greater than 50000 burnings hours with 60 months warranty including fixing,connection and commissioning of Street Light luminaire with suitable dia heavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure/ wall DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; DRIVER PERFORMANCE REQUIREMENTS: IS 16104, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE SHALL BE PROVIDED FROM MANUFACTURES OWN NABL LAB , LM 80 FOR LED SOURCE,T21 PROJECTION REPORT,LUMINAIRE & LED DRIVER TYPE TEST CERTIFICATES. ( Make: Philips (Signify) / Havells / Crompton / Bajaj/ Panasonic / Orient) (S= 2955.01, L= 0.00)
Supply , fixing, testing and commissioning of Dual faced indoor LED display signage as per approved design & specification. (S= 3935.57, L= 0.00)
SITC of Light emitting diodes illuminated signages fabricated by 25mm x 25mm aluminium border extrusion duly anodized having artwork as per desired from department having SMD LED light IP 20 make complete with fittings as per direction of EIC. (Size - 14" x 10") (S= 2534.27, L= 0.00)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
techcomplIIIIII.pdf
ATTACHMENT
Coomrl.compl.IVVVIVIIVIII.pdf
ATTACHMENT
AnnexureIX.pdf
ATTACHMENT
ANNEXURE-VIB.pdf
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
GCCACS1.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_2.pdf
ATTACHMENT
GCCforWorks-April2022-ACS-3-26.04.2023.pdf
ATTACHMENT
Checklist.pdf
ATTACHMENT
Tenderform.pdf
ATTACHMENT
2023_08_07RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT
2024_05_14ClarificationregardingsubmissionofAnnexure-VofGCC.pdf
ATTACHMENT
2023_12_21IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_6ACS-63.pdf
ATTACHMENT
2024_09_25IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
2024_12_20IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_8ACS-8.pdf
ATTACHMENT
2025_01_09IIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_9ACS-9.pdf
ATTACHMENT
2025_03_04RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_10ACS-10.pdf
ATTACHMENT
BIDdocumentasperGCC-22-uptoCorrection-11DSR-2023..pdf
ATTACHMENT
ANNEXURE-XI.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .