Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹27.0 L Quoted ₹28.8 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹29.6 L+₹74,915 (2.60%)Rejected-Finance | ₹29.6 L+₹74,915 (2.60%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹30.0 L+₹1.2 L (4.02%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹30.0 L+₹1.2 L (4.02%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹33.8 L+₹5.0 L (17.2%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹33.8 L+₹5.0 L (17.2%) | L4 | Rejected-Finance BEING L4 |
| 5 | L5₹33.9 L+₹5.0 L (17.5%)Rejected-Finance 88 197 B CHAMAN GANJ KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | ₹33.9 L+₹5.0 L (17.5%) | L5 | Rejected-Finance BEING L5 |
| Sl No | Description | Qty | Unit | MOHAN LAL AND SONS L3 | slathia construction works L4 | PAWAN KUMAR GOVT. CONTRACTORS L2 | ASIA BUILDER L5 | RANBIR ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for replacement of chemical earthing comprising copper earth plate electrode 900 x 600 x 5 mm thick burried directly in ground, earth pit not less than 3.10 metres below normal ground level and complete size of pit shall be 1.60 m x 1.60 m x 5.10 metres, with top edge of the plate not less than 3.75 metres below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnisium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 32 x 6 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 65 mm bore light grade pipe from electrode and upto, 15 mm bore watering pipe light grade GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt in appropriate qty, charcoal dustin appropriate qty and Magnisium sulphate in appropriate qty filling in each alternate layers upto 1.80 m height including excavation, removal surplush soil to a distance not exc. 50 m, complete all as specified and directed. | 25 | Each Job | 30,000 ₹7,50,000 | 20,000 ₹5,00,000 | 19,500 ₹4,87,500 | 14,000 ₹3,50,000 Lowest | 18,000 ₹4,50,000 |
| 2.00 | M & L for replacement of chemical earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 2.25 m below normal ground level, below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnisium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 20 x 3 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 65 mm bore light grade pipe from electrode and upto, 15 mm bore watering pipe light grade GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt in appropriate qty, charcoal dustin appropriate qty and Magnisium sulphate in appropriate qty filling in each alternate layers upto 1.80 m height including excavation, removal surplush soil to a distance not exc. 50 m, complete all as specified and directed. | 40 | Each Job | 9,100 ₹3,64,000 | 14,000 ₹5,60,000 | 9,500 ₹3,80,000 | 12,000 ₹4,80,000 | 9,000 ₹3,60,000 Lowest |
| 3.00 | M & L for replacement of copper earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to copper earth strip of size 20 X 3 mm by means of nut-bolts, check nuts and washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2020, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust and common salt all around the earth plate in alternate layers minimum 150 mm (compacted thickness) in all directions with and including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. | 50 | Each Job | 9,100 ₹4,55,000 | 11,000 ₹5,50,000 | 9,500 ₹4,75,000 | 11,000 ₹5,50,000 | 9,000 ₹4,50,000 Lowest |
| 4.00 | Repairing to existing defective chemical earthing comprising copper earth plate electrode 900 x 600 x 5 mm by taking out carefully earth plate, watering pipe, protection pipe and re-buried the same after removing sludge from the plate and pipes. The earth plate shall be buried directly in ground with top edge of earth plate not less than 1.50 m below normal ground level, connected to GI earth wire or GI / copper earth strip any size by means of nut-bolts, check nuts and washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and other end connected to main switch board / main DB’s / earthing test point testing of earthing on completion of job complete all as specified and directed. | 20 | Each Job | 1,500 ₹30,000 | 500 ₹10,000 Lowest | 500 ₹10,000 Lowest | 4,000 ₹80,000 | 1,600 ₹32,000 |
| 5.00 | Repairing to existing defective chemical earthing comprising copper earth plate electrode 600 x 600 x 3.15 mm by taking out carefully earth plate, watering pipe, protection pipe and re-buried the same after removing sludge from the plate and pipes. The earth plate shall be buried directly in ground with top edge of earth plate not less than 1.50 m below normal ground level, connected to GI earth wire or GI / copper earth strip any size by means of nut-bolts, check nuts and washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and other end connected to main switch board / main DB’s / earthing test point testing of earthing on completion of job complete all as specified and directed. | 10 | Each Job | 1,500 ₹15,000 | 500 ₹5,000 Lowest | 500 ₹5,000 Lowest | 4,000 ₹40,000 | 1,000 ₹10,000 |
| 6.00 | Repairing to existing defective copper earthing comprising conventional copper earth plate electrode 600 x 600 x 3.15 mm by taking out carefully earth plate, watering pipe, protection pipe and re-buried the same after removing sludge from the plate and pipes. The earth plate shall be buried directly in ground with top edge of earth plate not less than 1.50 m below normal ground level, connected to GI earth wire or GI / copper earth strip any size by means of nut-bolts, check nuts and washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and other end connected to main switch board / main DB’s / earthing test point testing of earthing on completion of job complete all as specified and directed.
Note on item No 4 to 6 (i) Necessary eath work will be measured and paid seperately.
(ii) Material like, salt charcoal, protection pipe, funnel and earth plate will be measured and paid seperately
(iii) Copper earth plate shall be measured and paid seprately. | 40 | Each Job | 1,500 ₹60,000 | 500 ₹20,000 Lowest | 500 ₹20,000 Lowest | 4,000 ₹1,60,000 | 1,600 ₹64,000 |
| 7.00Supply only following parts required for recharging of earthing strip complete all as specified and directed. | ||||||||
| 7.01 | Supply only Copper plate of size 900 mm x 600 cm x 5 mm including nut, bolt, washers made of copper alloy complete all as specified and directed by Engr-in-Charge | 15 | Each | 15,000 ₹2,25,000 | 15,000 ₹2,25,000 | 12,000 ₹1,80,000 | 5,000 ₹75,000 Lowest | 16,200 ₹2,43,000 |
| 7.02 | Supply only Copper plate of size 600 mm x 600 cm x 3.15 mm including nut, bolt, washers made of copper alloy complete all as specified and directed by Engr-in-Charge | 20 | Each | 5,500 ₹1,10,000 | 10,000 ₹2,00,000 | 7,000 ₹1,40,000 | 4,000 ₹80,000 Lowest | 7,000 ₹1,40,000 |
| 7.03 | Supply only salt commercial for the earth pit all as specified and directed | 10 | Qtl | 1,200 ₹12,000 | 400 ₹4,000 Lowest | 1,500 ₹15,000 | 4,000 ₹40,000 | 2,000 ₹20,000 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
4 Dec 2025, 6:00 pmClosed
GE AF UDHAMPUR
GE AF STATION UDHAMPUR
REPAIR/ REPLACEMENT OF CONVENTIONAL EARTHING / CHEMICAL EARTHING / BRAZING WORK OF STRIP, REPLACEMENT OF UNSV-SPDs ETC ALONGWITH CERTAIN ALLIED WORK AT AIR FORCE STATION NATHATOP UNDER GE (AF) UDHAMPUR
2025_MES_739623_1
GEAFU-60/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (AF) STATION UDHAMPUR
REPAIR/ REPLACEMENT OF CONVENTIONAL EARTHING / CHEMICAL EARTHING / BRAZING WORK OF STRIP, REPLACEMENT OF UNSV-SPDs ETC ALONGWITH CERTAIN ALLIED WORK AT AIR FORCE STATION NATHATOP UNDER GE (AF) UDHAMPUR
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹80,000
29 Dec 2025
13 Nov 2025
6 Dec 2025
13 Nov 2025
4 Dec 2025
27 Nov 2025
13 Nov 2025 - 20 Nov 2025
Amount
M & L for replacement of chemical earthing comprising copper earth plate electrode 900 x 600 x 5 mm thick burried directly in ground, earth pit not less than 3.10 metres below normal ground level and complete size of pit shall be 1.60 m x 1.60 m x 5.10 metres, with top edge of the plate not less than 3.75 metres below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnisium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 32 x 6 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 65 mm bore light grade pipe from electrode and upto, 15 mm bore watering pipe light grade GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt in appropriate qty, charcoal dustin appropriate qty and Magnisium sulphate in appropriate qty filling in each alternate layers upto 1.80 m height including excavation, removal surplush soil to a distance not exc. 50 m, complete all as specified and directed.
M & L for replacement of chemical earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 2.25 m below normal ground level, below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnisium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 20 x 3 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 65 mm bore light grade pipe from electrode and upto, 15 mm bore watering pipe light grade GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt in appropriate qty, charcoal dustin appropriate qty and Magnisium sulphate in appropriate qty filling in each alternate layers upto 1.80 m height including excavation, removal surplush soil to a distance not exc. 50 m, complete all as specified and directed.
M & L for replacement of copper earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to copper earth strip of size 20 X 3 mm by means of nut-bolts, check nuts and washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2020, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust and common salt all around the earth plate in alternate layers minimum 150 mm (compacted thickness) in all directions with and including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed.
Repairing to existing defective chemical earthing comprising copper earth plate electrode 900 x 600 x 5 mm by taking out carefully earth plate, watering pipe, protection pipe and re-buried the same after removing sludge from the plate and pipes. The earth plate shall be buried directly in ground with top edge of earth plate not less than 1.50 m below normal ground level, connected to GI earth wire or GI / copper earth strip any size by means of nut-bolts, check nuts and washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and other end connected to main switch board / main DB’s / earthing test point testing of earthing on completion of job complete all as specified and directed.
Repairing to existing defective chemical earthing comprising copper earth plate electrode 600 x 600 x 3.15 mm by taking out carefully earth plate, watering pipe, protection pipe and re-buried the same after removing sludge from the plate and pipes. The earth plate shall be buried directly in ground with top edge of earth plate not less than 1.50 m below normal ground level, connected to GI earth wire or GI / copper earth strip any size by means of nut-bolts, check nuts and washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and other end connected to main switch board / main DB’s / earthing test point testing of earthing on completion of job complete all as specified and directed.
Repairing to existing defective copper earthing comprising conventional copper earth plate electrode 600 x 600 x 3.15 mm by taking out carefully earth plate, watering pipe, protection pipe and re-buried the same after removing sludge from the plate and pipes. The earth plate shall be buried directly in ground with top edge of earth plate not less than 1.50 m below normal ground level, connected to GI earth wire or GI / copper earth strip any size by means of nut-bolts, check nuts and washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and other end connected to main switch board / main DB’s / earthing test point testing of earthing on completion of job complete all as specified and directed. Note on item No 4 to 6 (i) Necessary eath work will be measured and paid seperately. (ii) Material like, salt charcoal, protection pipe, funnel and earth plate will be measured and paid seperately (iii) Copper earth plate shall be measured and paid seprately.
Supply only following parts required for recharging of earthing strip complete all as specified and directed.
Supply only Copper plate of size 900 mm x 600 cm x 5 mm including nut, bolt, washers made of copper alloy complete all as specified and directed by Engr-in-Charge
Supply only Copper plate of size 600 mm x 600 cm x 3.15 mm including nut, bolt, washers made of copper alloy complete all as specified and directed by Engr-in-Charge
Supply only salt commercial for the earth pit all as specified and directed
Supply only charcoal dust for the earth pit all as specified and directed.
Supply only cement concrete earth pit chamber in PCC 1:3:6, type C-1, 450 X 450 X 50 mm thick Pre-cast RCC cover in cement concrete 1:2:4, type B-1, duly reinforced with 8 mm dia mild steel TMT bars with fair finished concrete surfaces including necessary formwork and earth work as required/ordered at site, complete all as specified and as directed.
Supply only Pre-cast RCC Cover with Handle 2 Nos and hole of dia 40mm in Cement Concrete 1:2:4 (20mm graded stone aggregate) of size 540x540x60mm, reinforced with and including 10mm dia TMT Bars @ 250mm Centre to Centre in both ways, complete all as specified and as directed.
Supply only CI funnel made as specified in SSR Part -I electrical plate No 3 fixed with GI pipe of watering by welding or threading etc including taking down old unserviceable complete all as specified and as diirected.
Dismantling the existing earthing pit chamber made of PCC 1:2:4 type B-I (using 20 mm graded crushed stone aggregate) and cleaning the area including removal of broken PCC/excavated material 50 mtr away from site all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:2:4 type C2 using 40 mm graded stone aggregate as construction of earthing pit all as directed including use & waste of necessary form work all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 200 mm graded stone aggregate as construction of earthing pit cover all as directed including use & waste of necessary form work all as specified and as directed.
S&F in repair as new test point terminal block made of gun metal or phosphorus bronze size (75x75x25)mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screws for holding the bronze plate including fastening/ bolting the roof down conductor and earth electrode over the bronze plate with copper bolts & nuts of suitable size, providing 10mm thick fibre sheet of size (15x15)cm below the test point to avoid direct contact with wall including enclosing the test point with 1.6mm thick MS sheet front openable box duly painted complete all as specified and as directed.
M&L for Painting of old existing cement concerete earth pit chamber in colour code as white for convintional, yellow for copper conventional and red for chemical including preparation of surface , removal of dust etc and applying two coat of suitable paint complete all as directed by Engr-in-Charge.
M&L for taking out loose/displaced Unserviceable existing Aluminium Strip/ Copper Strip/ GI Strip of any size and make or any description including all accessories and refixing the same with necessary Fixing Arrangement like screws, saddles, nuts and bolts, complete all as specified and as directed. Note : (i) Cost of Screws, Saddles, Nuts and Bolts of copper/brass, etc. will deemed to be included in the Quoted Unit Rate. (ii) If T&P like hydra and others equipment required at site of building upto 10mtr height shall be measured and paid seprately.
Material and Labour for earth continuity conductor or main galvanised iron earth strip of size 32 x 6 mm burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed.
All as per item No. 14 hereinbefore but copper stip of size 25 x3 mm
All as per item No. 14 hereinbefore but copper stip of size 20 x 3mm
All as per item No. 14 hereinbefore but copper stip of size 32 x 6 mm
S & F of 25 mm dia of GI tubing, light grade with all fittings including fixing arrangement with screws, reducer and clamps fasnig as protection of wire on wall/ roof with suitable type of clamp and proper fixing of insulator up to 15mtr building height etc complete all as specified and directed.
S & F of 25 mm dia of GI tubing, medium grade with all fittings including fixing arrangement with screws, reducer and clamps fasnig as protection of wire on wall/ roof with suitable type of clamp and proper fixing of insulator up to 15mtr building height etc complete all as specified and directed.
S & F of 40 mm dia of GI tubing, light grade with all fittings including fixing arrangement with screws, reducer and clamps fasnig as protection of wire on wall/ roof with suitable type of clamp and proper fixing of insulator up to 15mtr building height etc complete all as specified and directed.
S & F of 40 mm dia of GI tubing, medium grade with all fittings including fixing arrangement with screws, reducer and clamps fasnig as protection of wire on wall/ roof with suitable type of clamp and proper fixing of insulator up to 15mtr building height etc complete all as specified and directed.
S & F of 50 mm dia of GI tubing, light grade with all fittings including fixing arrangement with screws, reducer and clamps fasnig as protection of wire on wall/ roof with suitable type of clamp and proper fixing of insulator up to 15mtr building height etc complete all as specified and directed.
S & F of 50 mm dia of GI tubing, medium grade with all fittings including fixing arrangement with screws, reducer and clamps fasnig as protection of wire on wall/ roof with suitable type of clamp and proper fixing of insulator up to 15mtr building height etc complete all as specified and directed.
S & F High density polyethylene pipes (HDPE)of dia 32 mm as earthing contunuity protection laid in trenches/wall/floor complete all as specified and directed
Cutting grass, removing of surplus of Soil from old existing serviceable earthing chamber pit and aligning in the centre line of earthing strip including taking old and properly filled of soil around chamber and repair of chamber is required at site with PCC 1:3:6, type C-1 complete all as specified and directed
S & F as in replacement single pointed air termination aluminum rod, 12 mm dia and 300 mm long mounted on arrester clamp 12 mm made out of brass/gun metal/screw nut, bolt complete all as specified and drected.
S & F as in replacement single pointed air termination aluminum rod, 12 mm dia and 300 mm long mounted on galvanised iron steel tubing 40 mm bore (dia) 1.5 mtr long light grade with all fittings out of brass/gun metal/screw nut, bolt complete all as specified and drected.
S & F as in replacement single pointed air termination copper rod, 12 mm dia and 300 mm long mounted on arrester clamp 12mm made out of brass/gun metal/screw nut, bolt complete all as specified and drected.
S & F as in replacement single pointed air termination copper rod, 12 mm dia and 300 mm long with galvanised iron steel tubing 40 mm bore (dia) 1.5 mtr long light grade with all fittings out of brass/gun metal/screw nut, bolt complete all as specified and drected.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted sections all as directed.
M&L for Checking of Earth Resistance test of existing Galvanised iron/copper conventional/Chemical Earthing for getting suitable resistant test complete all as specified and directed by Engr-in-Charge. Note :- (a) Contractor will Check Earth Resistance of test points and will be recorded in Register, same will be put up to the Engineer-in-Charge through concern JE E/M. (b) Necessary T&P will be provided by the Contractor. (Tester should be caliberated from NABL accredited labs). (c) Contractor will be responsible for pouring of water in the Earth Pits Weekly at his own arrangement with Water Tanker, etc. (d) Checking of Earth Pits existing and improve it by watering, adding of chemical etc. (Chemical will be measured and paid separately) (e) Contractor will be responsible for marking of Earth Check date and due date on existing Plate with paint as specified by Engineer-in-Charge. (f) Contractor will be responsible for cleaning of bushes, grass, sand etc inside and all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip. (g) Cost of register for noting earthing results, location wise shall deemed to be included with the unit rate. Proforma of detail column will be printed as per the direction of Engineer-in-charge. (j) The contractor is responsible for mainting the value of chemical earthing as per station norms as directred by Engr-in-Charge. (k) Grid if any nos of earth pits having one test point shall be considered as one point for measurement.
M&L for supply and pouring of Earth Enhancement Compound after mixing with water tested by NABL accredited lab in compliance to IEC 62561-7 with a resistivity < 0.12 ohm-m. It shall be free from bentonite and other hazardous substances. It shall be a permanent, non-corrosive material and will not leach any chemicals into the ground. It shall retain moisture even in high soil resistivity areas. complete all as specified and as directed. Note: (i) Measurement of Chemical will be done in Powder form. (ii) Test certificate to be submitted to Engineer in Charge before purchasing of material.
Taking down old unserviceable of any type of earthing marker and Supply and fixing of Earthing identifier marker of size 25x25 mm flat iron and 5 mm thick length of flat iron 75 cm long which is 60 cm FI above the Ground level and 15 cm length FI below the Ground level and fixed with PCC 1:2:4 (12.5 mm graded aggregate) in post holes and the TOP of the flat iron arabolic/ semicirculer/ traingular/rectangular shape MS plate 1.6 mm thick of size 30 cm width and 20 cm height to welded/fixing to the flat iron including two coat of synthetic enamel paint over a coat of primer on steel surface cutting for Equipment Earthing/Lighting Earthing/L2 Earthing etc complete all including Earth Plate No/Description of Earthing/Type of Earthing on Plate with white paint including earth plate no and earthing resistance with earthing check date and earthing check due date complete all specified and directed by Engineer in charge.
Taking down existing hanging, broken, and delocation of air termination copper/Aluminium rod of any make and size from roof of existing buildings height upto 15 metres from buildings and refixing the same after repair including brazing,nuts, bolt and insulators complete all as specified and directed. Note : T&P shall be measured and paid seperately.
M&L heavy duty porcelain/poly carbonate insulators of size 32 x 32mm to be fixed on wall/roof/pipe for laying of copper strip as roof/down conductor on building of height between upto 25 metres including nuts & bolts of brass of appropriate size including taking down old unserviceable one. all as specified and as directed by Engr-in-Charge
M&L for down/roof conductor using 16 sqmm single core copper cable both ends thimbled properly with copper Lugs including taking down complete all as specified and directed.
M&L for down/roof conductor using 25 sqmm single core copper cable both ends thimbled properly with copper Lugs including taking down complete all as specified and directed.
M & L for brazing work with copper brazing alloy rod with help of oxygen and LPG cylinder using required copper strip of size 20 mm x 3mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper which are laid as roof/down conductor on any height of building up to 15 mtr building height complete all as specified and directed by Engr-in-Charge.
M & L for brazing work with copper brazing alloy rod with help of oxygen and LPG cylinder using required copper strip of size 25 mm x 3mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper which are laid as roof/down conductor on any height of building up to 15 mtr building height complete all as specified and directed by Engr-in-Charge.
M & L for brazing work with copper brazing alloy rod with help of oxygen and LPG cylinder using required copper strip of size 32 mm x 6 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper which are laid as roof/down conductor on any height of building up to 15 mtr building height complete all as specified and directed by Engr-in-Charge.
M&L for T&P for laying/rectification of earthing strip, termination of rod and brazing of any capacity up to 20 Mtr height of buildings with T&P like ledder or hydra and other required at site complete all as specified and directed Note : (i) T&P like hydra ond other if required at site shall be included in the quated rate. (ii) The bidders are requested to produce Vehicle BA No/ Chasis No & gate pass with date at the time of processing of RAR. (iii) All complaints at the time of using of hydra shall be done in a single day.
M & L for brazing work with GI brazing alloy rod with help of oxygen and LPG cylinder using required galvanised strip of size 20 mm x 3 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper which are laid as roof/down conductor on any height of building up to 15 mtr building height complete all as specified and directed by Engr-in-Charge.
Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc or /getting out cable cover and stacking for reuse/ credit , trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for soft/loose natural soil low resistivity suitable for Earthing along with filling, spreading at site all as specified as and as directed by Engr-in-Charge.
Material and Labour for earth continuity conductor or main Aluminium Earth strip of size 25 x 3mm burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necessary insulators and fastening screws, rawl plugs complete all as specified and directed.
Description written as Item No 48 M&L for Construction of copper bus bar not less than 80 mm x6 mm duly fabricated including drilling of holes with fasten in wall/roof complete all as specified and directed..
PAWAN KUMAR GOVT. CONTRACTORS (BID ID -3494790)
MOHAN LAL AND SONS (BID ID -3489098)
slathia construction works (BID ID -3489432)
ASIA BUILDER (BID ID -3492734)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TENDER60.pdf
Tender Documents • 1.48 MB
BOQ_828170.xls
BOQ • 4.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .