Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC RONGMEN BLOCK IV NEAR UMROI MILITARY STATION P O BARAPANI SHILLONG 793103 | SHILLONG | RI BHOI | MEGHALAYA | 793103 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹36.2 L+₹70,501.18 (1.99%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 3 | L3₹36.2 L+₹77,803.98 (2.19%)Rejected-Finance C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L3 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 4 | L4₹37.5 L+₹2.1 L (5.84%)Rejected-Finance LAMA VILLA DYMMIEW SHILLONG 793002 | EAST KHASI HILLS | MEGHALAYA | 793002 | L4 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 5 | L5₹38.7 L+₹3.2 L (9.15%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Jun 2025, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG PIN 793002
REPAIR/MAINT OF LT OVER HEAD LINES AND LT UG CABLES AND LT PANEL AND MCCB AND RELAYS AND ALLIED WORKS HAPPY VALLEY AND SE FALLS AREA UNDER GE SHILLONG
2025_MES_708501_1
GE/SHL/TOKEN-16 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE SHILLONG
₹80,000
Yes
16 Jul 2025
16 May 2025
14 Jun 2025
16 May 2025
13 Jun 2025
30 May 2025
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in hard/dense soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.
Supply and fixing/laying 40mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable complete all as specified and as directed.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. Note :- Only punned down sand shall be measured.
M&L for burnt clay class B bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core Iincluding laying in trench or fixed on wall through clamps complete all as specified and as directed by Engr-in-Charge.
All as item No 9 but of size 16Sqmm 2 core
All as item No 9 but of size 16Sqmm 4 core
All as item No 9 but of size 35Sqmm 3.5 core
All as item No 9 but of size 50Sqmm 3.5 core
All as item No 9 but of size 70Sqmm 3.5 core
All as item No 9 but of size 95Sqmm 3.5 core
All as item No 9 but of size 185 Sqmm 3.5 core
Dismantling/taking out carefully of old LT cable including bricks of any size type or core and kept aside for reuse / rerouting / jointing / replacement etc complete
Laying only serviceable bricks for protection of cable obtained during excavation from item No. 16 here-in-before.
S & F flexible wire of size 6 Sqmm 2 core copper conductor fixed with clamps complete all as specified and directed by Engr-in-charge.
S & F flexible wire of size 10 Sqmm 2 core copper conductor fixed with clamps complete all as specified and directed by Engr-in-charge.
M&L Painting of outdoor/indoor Feeder Pillar Boxes of MS Sheet with spray gun after scrapping old surfaces any size complete all as specified and directed.
M&L for Mild steel work as in doors of LT feeder pillar boxes grade Fe 410 or Fe 310 including joint/hinges with panel including spray painting to including taking down old unserviceable one complete.
M & L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 6 to 16 Sqmm 4 core including testing after jointing complete all as specified & directed.
All as item No 23 but 25 to 50 Sqmm 4 Core
All as item No 23 but 70 to 120 Sqmm 4 Core
Isolate, disconnect, dismantle the burnt out lugs of size 06sqmm to 16 sqmm from main switches/MCCB/ACB/Breakers and Supply and fix new lugs with crimping tool as per existing one including fixing, insulation, termination to main switches/MCCB/ACB/Breakers for the following sizes of cables complete al as directed.
Isolate, disconnect, dismantle the burnt out lugs of size 25sqmm to 50 sqmm from main switches/MCCB/ACB/Breakers and Supply and fix new lugs with crimping tool as per existing one including fixing, insulation, termination to main switches/MCCB/ACB/Breakers for the following sizes of cables complete al as directed.
Isolate, disconnect, dismantle the burnt out lugs of size 70sqmm to 95 sqmm from main switches/MCCB/ACB/Breakers and Supply and fix new lugs with crimping tool as per existing one including fixing, insulation, termination to main switches/MCCB/ACB/Breakers for the following sizes of cables complete al as directed.
Isolate, disconnect, dismantle the burnt out lugs of size 120sqmm to 240 sqmm from main switches/MCCB/ACB/Breakers and Supply and fix new lugs with crimping tool as per existing one including fixing, insulation, termination to main switches/MCCB/ACB/Breakers for the following sizes of cables complete al as directed.
Isolate, disconnect, dismantle the burnt out lugs of size 300sqmm to 400 sqmm from main switches/MCCB/ACB/Breakers and Supply and fix new lugs with crimping tool as per existing one including fixing, insulation, termination to main switches/MCCB/ACB/Breakers for the following sizes of cables complete al as directed.
S & F in repair MCCB 4 pole , 415 V adjustable type 630 Amp, with breaking capacity 50 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one all as specified and directed.
S & F in repair MCCB 4 pole , 415 V adjustable type 400 Amp, with breaking capacity 36 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S & F in repair MCCB 4 pole , 415 V adjustable type 320 Amp, with breaking capacity 36 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S & F in repair MCCB 4 pole , 415 V adjustable type 250 Amp, with breaking capacity 36 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S & F in repair MCCB 4 pole , 415 V adjustable type 200 Amp, with breaking capacity 36 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S & F in repair MCCB 4 pole , 415 V adjustable type 160 Amp, with breaking capacity 36 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S & F in repair MCCB 4 pole , 415 V Fixed type 100 Amp, with breaking capacity 16 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S & F in repair MCCB 4 pole , 415 V Fixed type 63 Amp, with breaking capacity 16 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
Supply and Fix in repair Digital Voltmeter including connection with metering system and taking down old unserviceable one complete all as specified and directed.
Supply and Fix in repair Digital Ammeter including connection with metering system and taking down old unserviceable one complete all as specified and directed.
Dismantling existing steel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc all as specified and directed.
M & L for Steel tubular swaged poles complete with cast iron/MS base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-22 , 8.5 meter long complete all as specified & directed. Note: PCC anti climbing device, cross arms insulator, ACSR conductor and earth work measure and paid separately)
M & L for cross arms , bracing, supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms and completeall as specified and directed.
M & L for fixing of aluminium busbar chamber 200A TPN with 4 outgoing ways ingress protection IP 42 mounted of channels 30cm above the ground fixed on 15cm thick PCC plateform including nut bolts etc and fixing of LT cable/wires by end terminals with proper taping of cable head including taking down unserviceable one complete all as specified and as directed.
M & L for fixing of aluminium busbar chamber 315A TPN with 4 outgoing ways ingress protection IP 42 mounted of channels 30cm above the ground fixed on 15cm thick PCC plateform including nut bolts etc and fixing of LT cable/wires by end terminals with proper taping of cable head including taking down unserviceable one complete all as specified and as directed.
Dismantling service pole from roof sheet including nut bolts washers etc complete all as specified and directed.
Dismantling existing earthing stip of any size and description and refixing the same with replacement of insulator complete all as specified and directed. (Note: Insulators used will be measured and paid under appropriate items)
Supply only insulator appropriate for strips relaying under item No. 42.
S & Fix Earth continuity conductor of size 25 mm x 4 mm GI strip fixed to wall on batten or recess with porcelein insulators or chases or buried in ground or drawn in conduit/pipe or fixed to poles with porcelein insulators or any other indicated situation for earthing etc complete all as specified and directed.
Material and labour in repair for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate and bentonite powder , using GI strip of size 25x4mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I and testing on completion complete all as specified and directed.
M/s Nishi Kumar Das (BID ID -3315888)
S K Construction (BID ID -3312688)
M/S DIL SINGH BISWA AND CO (BID ID -3322321)
M/S. Ranjit Kumar (BID ID -3315250)
M/s A L Traders (BID ID -3321443)
M/S U.K ENTERPRISE (BID ID -3322501)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .