Executive Engineer (Elect.)
BSNL, Electrical Division, Ghaziabad
Pdg EI and Fans and ITC and Repairing of DG sets at BTS P-5 in Noida BA.
2024_BSNL_812767_1
34/EEE/BSNL/ED/GZB/2024-25
Open Tender
Miscellaneous Works
Item Rate
60 days
P-5 Noida
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
Account Officer Cash, B.S.N.L, Ghaziabad
₹2,413
27 Jul 2024
20 Jun 2024
16 Jul 2024
20 Jun 2024
15 Jul 2024
20 Jun 2024
Shifting of L.T. Panel ( Size-1.7m x 1.1m x 0.3m ) from TE Sect 58 to P-5 BTS i/c loading - unloading with specialize man power e etc. complete as required.
ITC of LT Panel , connection , testing etc
S/F Digital ameter (Make- SELEC -MA 302 or similar superior make)
ITC of main Switch, connection , testing etc
I.T.C of 15 KVA E/A set with canopy complete with control panel, exhaust pipe, fuel tank, battery, control cables etc.on the existing foundation i/c connection of power cable, exhaust pipe & earthing strip etc. as required.
Servicing of existing 15 KVA E/A set i/c replacement of consumables such as lube oil, lube oil filter, diesel filters etc. complete as required.
Providing N-bolt and locks in doors etc
Cleaning of diesel tank from inner side etc
Cleaning of DG set and Canopy inner side, removing all dust and dirt etc
Painting of outer side of canopyi/c removing dust, red oxide and painting with good quality of paint etc
S/F AVR Unit in DG set ,connection ,testing etc
S/F Battery charger (Transfrmer type) etc
S/F Fuel pipe in DG set etc
S/F Sheet in panel in DG set etc
S/F Hour meter in DG set , connection etc
Providing Cu lead 16sqmm for Battery, connection etc
S/F Battery terminal/ lugs for battery etc
S/F Fan Belt in DG set , etc
S/F Starting switch in DG set , connection etc
S/F Hose pipe in DG set , etc
S/F Clamp for hose pipe etc
S/F Push button , connection etc
Repairing of Self starter12v ,dismentalling & to & fro journey to workshop, i/c replacement of faulty parts, connection, testing etc-
Repairing of DC Altenator ,dismentalling & to & fro journey to workshop, i/c replacement of faulty parts, connection, testing etc
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed in medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.a) Group A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (A) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(B) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
(C) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supply & Fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c providing and fixing 6 pin 15/16 Amps socket outlet and 15/16 Amps piano type switch connection, painting etc. as required.
Supplying and fixing of DP sheet steel enclosure in recess or surface with 25/32 Amp, 240 Volt, C curve DP MCB i/c connection etc as reqd. -- For AC
S/F of following electrical accessories ,connection etc as required. (A) Switch 5A Piano type--
(B) Socket 3 pin 5A Piano type -
SITC of 400 mm Sweep oscillating type cabin fan suitable for operation on 230 volts 50 Hz. A.C. supply complete with accessories etc (M/s Bajaj/Surya/Khaitan or Similar superior make)
SITC of Exhaust Fan 300mm sweep, 1350 rpm, 230V A.C. supply complete with accessories etc (M/s Havells- Ventil Air DSP /Bajaj/ Surya,/Khaitan or Similar superior make))
SITC of 20 Watt 1200 mm LED tubelight omplete with all accessories etc. as required. (M/s Phillips / Havells/ Bajaj/ Crompton or SS make)
S/F Pendent/ Batten Holder etc
S/F LED Bulb 20 w etc
S/F Cu wire 2 core 1.5 sqmm etc
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of DG set etc including form work etc as required ( (2.25 mtr x1.20mtrx 0.3 mtr =0.81 cu mtr- Sect 24)
Earthing with GI Pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/ coke and salt as reqd For DG Neutral -02 nos, Body earth -02 nos, For Neutral Power supply co -01 no Total- 05 nos
Pdg.& fixing following wire/ cable/ strip on surface or in recess for loop earthing alongwith the existing surface/recessed conduit / submain wiring / cable etc.as required. (A) 4 sqmm FRLS PVC insulated Cu conductor single core cable ( for neutral earthing )
(B) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
(c ) Pdg.& fixing 6 SWG GI wire on surface or in recess for loop earthing along with the existing surface/recessed / cable etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm on wall/ surface/ in loop as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 4X16 sqmm/3.5 x 25 Sq.mm /35 sqmm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .