| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.4 CrAccepted-AOC MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹84.4 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹89.9 CrRejected-Finance PLOT NO 65 SECTOR 18 OPP HIPA SARHAUL GURUGRAM 122 001 | ₹89.9 Cr | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹92.8 CrRejected-Finance | ₹92.8 Cr | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹93.4 CrRejected-Finance | ₹93.4 Cr | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹93.6 CrRejected-Finance PLOT NO 16 OPP METRO PILLAR NO 190 PASCHIM VIHAR EXTENSION ROHTAK ROAD DELHI 110 063 | ₹93.6 Cr | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹86.6 Cr
EMD Value
₹15 L
Closing Date
3 May 2022, 6:00 pmClosed
CE CG GOA
CE CG GOA 403806
PROVISION OF MARRIED ACCOMODATION AND ALLIED FACILITIES AT AMADALI KARWAR UNDER GE I CG GOA
2022_MES_514392_1
82060/E8
Open Tender
Civil Works
780 days
KARWAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) (CG) GOA
₹15 L
Yes
23 Jun 2022
19 Mar 2022
5 May 2022
19 Mar 2022
3 May 2022
18 Apr 2022
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( EARTH WORK/EXCAVATION/AREA DEVELOPEMENT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/CULVERT/HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (COMPOUND WALL AND GATE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DRAIN LINE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (LIGHTENING PROTECTION/EARTHINGS) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (TV & TELEPHONE LINE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (AVIATION OBSTRUCTION LIGHT & DG SET) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XV (HOT WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XVI (TREATED WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XVII (LIFT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XVIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
PILE FOUNDATION: Boring of cast in situ pile of 750 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Boring of cast in situ pile of 700 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Boring of cast in situ pile of 600 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Boring of cast in situ pile of 500 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Boring of cast in situ pile of 450 mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place out side MD land all as specified and directed.
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 with using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length/any sections complete all as specified and as shown on drg as in bored pile (Note:- RCC shall be measured and paid from cut off level and rates quoted shall be inclusive of cutting & knocking of RCC lattaince concrete from cut off level)
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 with using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg (Note:- Reinforcement will be measured and paid for seperately under relavent items of this schedule)
Providing TMT bars (CRS/HCR/CRM) in reinforcement 10 mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D).
Providing TMT bars (CRS/HCR/CRM) in reinforcement 10mm dia and over conforming to IS-1786 as Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D).
Providing TMT bars (CRS/HCR/CRM) in reinforcement 10 mm dia and over for pile caps/ grade beams all as shown on drgs including cut to length, bend to required shape, cranking/ hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs (Fe-500D).
Providing TMT bars (CRS/HCR/CRM) in reinforcement 5 mm dia and over up to and including 10mm dia conforming to IS-1786 as stirrups for pile caps/ grade beams cut to length, bent to shape required, and binding with mild steel wire (annealed) not less than 0.9mm dia or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs (Fe-500D).
M&L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed.
Formwork to sides of pile caps/ grade beams rough finished surface of concrete flat all as specified and as directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M deep or area not exceeding 10 sqm on plan and getting out in hard dense soil for pile caps all as specified and as directed.
Excavation in trenches not exceeding 1.5M wide and exceeding 1.5M deep and n, exc 3.0 m deep and getting out in hard dense soil for pile caps all as specified and as directed.
Excavating over areas, n exc 1.5 m deep and getting out hard dense soil for pile caps all as specified and as directed.
Excavating over areas, exc 1.5 m deep and getting out hard dense soil for pile caps all as specified and as directed..
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed.
Removing excavated soil material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed.
M&L for carrying out Initial Load test (vertical load test) cast in situ piles of 750 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out Initial Load test (vertical load test) cast in situ piles of 700 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out Initial Load test (vertical load test) cast in situ piles of 500 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out Initial Load test (vertical load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out lateral load test cast in situ piles of 750 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out lateral load test cast in situ piles of 700 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out lateral load test cast in situ piles of 600 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out lateral load test cast in situ piles of 500 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying lateral load test out cast in situ piles of 450 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out pull out testing of cast in situ piles of 750 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out pull out testing of cast in situ piles of 700 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out pull out testing of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out pull out testing of cast in situ piles of 500 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out pull out testing of out cast in situ piles of 450 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out Routine Load test (Vertical, Lateral & Pull out) all as per IS 2911 (Part 4) 2013 for 750 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
M&L for carrying out Routine Load test (Vertical, Lateral & Pull out) all as per IS 2911 (Part 4) 2013 for 700 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
M&L for carrying out Routine Load test (Vertical, Lateral & Pull out) all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out Routine Load test (Vertical, Lateral & Pull out) all as per IS 2911 (Part 4) 2013 for 500 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out Routine Load test (Vertical, Lateral & Pull out) all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out non destructive integrity test all as per IS14893-2001 for 750 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
M&L for carrying out non destructive integrity test all as per IS14893 -2001 for 700 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
M&L for carrying out non destructive integrity test all as per IS14893 -2001 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out non destructive integrity test all as per IS14893-2001 for 500 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out non destructive integrity test all as per IS14893-2001 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
INTERNAL ELECTRIFICATION:- S & F modular type bell ding dong of 2 module size, conforming to IS: 8884- 1978 complete all as specified and directed. Make: Legrand Arteor Cat-Part No. 5734 43 or equivalent model of ABB (snieo) / L&T (Entice) / Wipro
S & F modular type 1 module TV socket complete all as specified and directed. Make: Legrand Arteor Cat-Part No. 5734 25 or equivalent model of Precision
S & F modular type 1 module RJ 11 telephone socket with shutter complete all as specified and directed. Make: Legrand Arteor Cart-Part No. 5734 26 or equivalent model of ABB 211 / Anchor Panasonic (roma)
S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
S & F 10 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
S & F wall mounted LED fitting with 10W LED lamp having luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.
S & F 30 W LED street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 100 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket 1.5 m long with including necessary electrical connection to the fixture with 3 core flexible copper conductor cable of appropriate size and light grade GI pipe 20mm dia, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed. Make: BAJAJ Cat-Part No. BAJAJ 169829 BCLST 20W LED I or equivalent model of Havells, Philips or Wipro
S & F BEE one star rated energy efficient BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. Make: Crompton Cat-Part No. ENTRUST50 or Havells Cat- Part No. ES-50 or equivalent model of Usha or BAJAJ
S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent model of Usha, Havells or BAJAJ
S & F decorative wall mounting fitting with plastic body suitable for 09 Watt LED lamp etc complete with all accessories and including provision of two core flexible copper wire of size 23/0-.0076 and connecting up from ceiling rose to light fitting complete all as specified and directed Make:- Havells Cat Part No LHFOFUE1TZ1W0123 or eqivalent in Philips, Bajaj
S & F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. TRANS AIR 12" or equivalent model of Usha, Havells or BAJAJ
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type BUILDING PANEL of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of thermoplastic polycarbonate, cubicle type, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by Engineer-in-charge. The Building Feeder Panel shall comprise of the following:(For Type II QTR G+6 2 Blocks)
[A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 250 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i] 40 A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz DP MCB. - 24 Nos (For 23 QTR+1 spare ) [ii] Space for energy meter- 24Nos
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type BUILDING PANEL of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of thermoplastic polycarbonate, cubicle type, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by Engineer-in-charge. The Building Feeder Panel shall comprise of the following:( For TYPE III QTRS 4 NOS G+2 and TYPE II 8 QTR 2 Block G+2 )
[A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 100 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 63 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING:- [i] 40 A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz DP MCB. -5Nos(for 4 QTR+1spare ) [iii] Space for energy meter Single phase 6-32A- 5Nos
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type BUILDING PANEL of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of thermoplastic polycarbonate, cubicle type, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by Engineer-in- charge. The Building Feeder Panel shall comprise of the following:( For TYPE IV SPL 7 NOS 1 Block )
[A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING:- [i] 200 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [OUTGOING:- [i] 63 A, 230 V, Ics = 100% Icu = 16 kA, 50 Hz TPN MCB. -7Nos(for 7 QTR+1spare ) [II] 32 A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz TPN MCB. -7Nos(for 7 Servants QTR+1spare) [III] Space for 3 phase energy meter 10-63A-07Nos [IV) Space for 1 phase energy meter 6-32A-07Nos
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type BUILDING PANEL of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of thermoplastic polycarbonate, cubicle type, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by Engineer-in-charge. The Building Feeder Panel shall comprise of the following:TYPE V 4 NOS G+2 1 Block
[A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING:- [i] 125 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING:- [i] 63 A, 230 V, Ics = 100% Icu = 16 kA, 50 Hz TPN MCB. -5Nos(for 5QTR+1spare ) [II] 32 A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz TPN MCB. -7Nos(for 5 Servants QTR+1spare ) [III] Space for 3 phase energy meter 10-63A-05 Nos [IV) Space for 1 phase energy meter 6-32A-05 Nos
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type BUILDING PANEL of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of thermoplastic polycarbonate, cubicle type, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by Engineer-in-charge. The Building Feeder Panel shall comprise of the following:( For TYPE III QTRS 27 NOS G+7 1 Block 1)
[A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 200 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING:- [i] 40 A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz SP MCB. -28Nos(for 27 QTR+1spare ) [ii] Space for 1 phase energy meter- 28Nos
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of thermoplastic polycarbonate, cubicle type, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by Engineer-in-charge. (for Lift, Fire Pump and Coommon area Lighting from DG set)
[A] INCOMING(i) 63 Amps FP MCCB 01 No [B] OUTGOING:- (i)32 Amps TPN MCCB 03 Nos (ii) 3-phase energy meter (10 - 60 )Amp- 03 Nos (iii) 1-phase energy meter (10 - 60 )Amp- 03 Nos (iv) 20 A, DP MCB, C- curve -2Nos (v) Astronomical Timer + DP contactor 01 Nos NOTE:- Energy meter shall have Cl1.0 accuracy ,Tamper Proof, high durability, sleek LCD display energy meters having current range 10-60 A, capable of measuring kWh parameters complete all as specified and directed. Space for 1- Phase energy meter (10-60 Amp) Space for 3- Phase energy meter (10-60 Amp)
S & F Rigid non-metallic PVC conduit , 20mm dia, exclusive of boxes( junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locks, nuts, saddles, pipes, hooks etc complete all as specified and directed..
Supply, install and commissioning of 1-phase 2-wire 240V class 1.0 smart meter complying to IS-16444 Part I at the rating of 5-30A suitable for prepaid/postpaid mode all as specified and directed. Make:- L&T, EL measure, Panasonic/Anchor
Supply, install and commissioning of 3-phase 4-wire 3x240V class 1.0 smart meter complying to IS-16444 Part I at the rating of 10-60A suitable for prepaid/postpaid mode all as specified and directed. Make:- L&T, EL measure, Panasonic/Anchor
Supply, install and commissioning of DCUs/Gateways and and the arrangement of sim cards or internet to enable reliable medium for two-way communication between smart meter & HES all as specified and directed. Make:- L&T, EL measure, Panasonic/Anchor
Supply and configuration of cloud based with applications as specified in particular specifications, support for 2 years of defect liability period, training to Admin/operational team and End users.
Supply, installation and commissioning of 5 star rated 25 L electric geyser having temperature sensitive LED indicators, shock safe plug, PUF insulation, incoloy glass coated heating element, anode rod, adjustable knob, multi-functional safety valve with IP 4X protection all complete as specified and directed.Make: Havells Cat-Part No. GHWAPTTIV025 or equivalent model of Bajaj/Racold
S&F angular stop cock 15mm dia quarter turn complete all as specified and directed. Make:- Jaquar Model No CQT-23059 or equivalent
S&F two way bib tap/angle cock 15mm dia complete all as specified and directed. Make:- Jaquar Model No CQT-23041 or equivalent
S&F health faucet with flexible pipe (ABS body) with 01 meter long PVC tube and wall hook complete all as specified and directed. Make:- Jaquar Model No ALD-CHR -573 or equivalent
S&F bib cock 15mm dia complete all as specified and directed. Make:- Jaquar Model No CQT-23037 or equivalent
S&F central hole basin mixer without pop up waste system with 450 mm long braided hoses (15mm cartridge size) complete all as specified and directed. Make:- Jaquar Model No SOL-6167B or equivalent
M&L Electrically and hydraulically operated automatic tyre buster with a separate electro-hydraulic drive unit consist of an under ground casing and heavy duty steel spikes determined to destroy tyres,suspension and axis of a vehicle in case of unauthorised intrusion etc complete all as specified and directed. Specifications:- Length-6 Metre, Width- 700mm, Spike dimension- 250mmx25mm, Blocking angle- 45 Degrees to 90 Degrees, Operating time- amx 6 sec, Thickness of strip-(top plate of tyre killer)-12mm, Motor revolution-1440 RPM, Power consumption- 1.5KW, Max current consumption-15A, Material of construction-Galvanised mild steel with corrosion free under all weather condition, Load capacity- 50T, Operational capacity- Push Button(Optional wireless remote)
Supply,laying and testing cable XLPE insulated,screened,PVC bedded,galvanised steel strip or wire armoured,electric power cables(heavy duty) 1100 Volts grade with strandard aluminium conductor of size 10Sqmm 4 Core complete all as specified and directed.
S&F Concertina coil 610mm dia bade out of 2.6mm spring steel wire of UTS 145 to 150 N/Sqm ,zinc coating 250 to 300 Gms/Sqm dia of coil unstreched shall be 610mm having min of coil having (2min) dipped with and including white colour each coil having 50 turns (circles) and including handle and spike at both ends of coil erected in position on top mild steel angle by fixing with MS rod for securing including necessary welding/clipping to MS sections etc complete all as specified and directed.
ROAD:- S&F Twoway road studs of plastic body reflective panel Amber/Red/White of size 100x100x25 mm fixed with screw or installed using epoxy adhesive and necessary earth work and PCC required complete all as specified and directed.d. Make: Dark eye/Tata BP
S&F Bi-directional sparking road studs working on high efficiency crystalline silicon solar cells, enclosed in aluminium die cast matt finished enclosure of size 125x125x90mm self operated dusk to dawn with 1.2 V battery having ultra bright LEDs and high intensity reflective grade polymer sticker complete installed complete all as specified and directed. (Make: Sparkle solar studs manufactured by M/s Tata BP solar/dark Eye)
M&L for provision and applying 2.5mm thick 10cm wide road marking strips (reflective) of specified shade or colour using hot thermoplastic material by fully automatic thermoplastic paint applicator machine fitted with profile shoe heater driven by experienced operator on road surface incl tools&plants ,cleaning the road surface of all dirt,scales,oil,grease,foreign materials etc complete all as specified and directed
S&F Convex mirror with high quality acrylic polycarbonate mirror of 80cm dia with telescopic rod with sufficient height including fixing in concrete complete all as specified and as directed
M& L Stainless steel Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high all as specified complete all as specified and directed.
BASKET BALL POLE M&L for providing and supplying 01 pair 8" dia MS round pole with 3.2m extension having 10' standard height above ground level, rim height 10' rim diameter 18' with 25mm thick Malaysian acrylic boards of size 1.80 x 1.05M normal rings and net complete including neccessary civil works ie, excavation, concrete filling, painting etc as required all as specified and directed by Engr in charge.
HOT EATER SUPPLY:- S&F Ball valves CPVC with handle, fancy type of size 20mm complete all as specified and as directed.
S&F Ball valves CPVC with handle, fancy type of size 25mm complete all as specified and as directed.
S&F Ball valves CPVC with handle, fancy type of size 50mm complete all as specified and as directed.
S&F Ball valves CPVC with handle, fancy type of size 65mm complete all as specified and as directed.
SEWAGE TREATMENT PLANT:- Designing (hydralically, structarally & aesthetically), providing, constructing, hydraulic testing, commissioning & giving satisfactory trials of STP capacity not less than 150 KLD consisting of inlet chamber(RCC), fine bar screen chamber(manual) RCC with steel screen, oil and grese removal (RCC) ,Greet saparator, equilization tank (2 tank of 50 % capacity each), air grid for equilization tanks, Feed Pumps(2 Nos), Moving Bed Bio Reactors (MBBR) with plastic media (of a[ppropriate dencity, size and Qty to keep very hihh MLSS>15000 mg/lit), Air blowers of MBBR, tube setller assembly, Sludge drying Bed of appropriate size, chlorine dosing system, Chlorine contact tank, Foundation for all E/M equipments, associated piping work with required valves, gates, drains, Path ways, Electrical Conterol Panel with inter connecting cable, spare parts for 2 years of opration, etc. Complete as turnkey job with all involving Civil, Electrical, Digital & Mechanical Work as per detail Specification for Civil,Electrical & Mechanical components with all duties and taxes complete including teritary treatement it also includes Filter Feed Tank of RCC,filter feed pump,DMF,ACF, treated water tank in RCC. treated sewage can be used for irrigation, Horticulture complete all as specified and as directed. NOTE:- (a) Design and layout scheme of STP to be vetted from IIT/NIT/Govt Engg College & approved from HQ CE (CG) Goa. (b) Design of STP shall confirm to latest NGT guidelines.
EXTERNAL ELECTRIC SUPPLY:- Supply and installation of RMU HT 33 KV 3 phase 50Hz totally enclossed metal clad SF 6 switch gear panel withcover load and earth fault proctection , ammeter ,volt meter 630 Amps Load break switch with earth switch with following capacity breaker (a) Repturing capacity 350MVA and 630A - 1 No (I/C) (b) Repturing capacity 250MVA and 630A - 2 No (01 OG to RA & 01 OG to OTM)
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 33000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed.
Supply and fix cable jointing kit for 33 KV grade cable for indoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sq mm complete all as specified and as directed.
Supply and installation of copper wound transformer step up/ step down, Outdoor type complete with standard fittings, HT 33 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 and its latest amendments, of capacity 500 KVA complete all as specified and as directed.
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 1000 Amps capacity, intdoor cubical type floor mounted factory made double door dust and vermin proof fabricated out of thermoplastic polycarbonate enclosure cubicle type fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (Main LT panel)
[A] INCOMING:- (a) Multifunction panel meter with CTs (b) ACB with microprocessor based release, 4 pole, 800 AMPS, 50 Hz, 415 Volt, 50 KA - 1 No (Incoming) (B) OUTGOINGS:- (a) MCCB, 4 pole, 400 Amps, 50 Hz, 415 Volts, 35 KA -01 No (For FP 1(Sailors)) (b) MCCB, 4 pole, 250 Amps, 50 Hz, 415 Volts, 35 KA -01 No (For Main DG Panel & 01 spare) (c) MCCB, 4 pole, 200 Amps, 50 Hz, 415 Volts, 35 KA -01 No (For APFC Panel) (d) MCCB, 4 pole, 200 Amps, 50 Hz, 415 Volts, 25 KA -01 No (For FP 2 (Offr)) (e) MCB SP 10 Amps 230 Volts 50 Hz (Sub stn Bldg)
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 1000 Amps capacity,Out door cubical type floor mounted factory made double door dust and vermin proof fabricated out of thermoplastic polycarbonate enclosure cubicle type fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (FP 01(Sailors)
[A] INCOMING:- (a) Multifunction panel meter with CTs (b) MCCB with microprocessor based release, 4 pole, 400 AMPS, 50 Hz, 415 Volt, 35 KA - 1 No (Incoming) (B) OUTGOINGS:- (a) MCCB, 4 pole, 160 Amps, 50 Hz, 415 Volts, 35 KA -01 No (b) MCCB, 4 pole, 125 Amps, 50 Hz, 415 Volts, 35 KA -02 Nos (c) MCCB, 4 pole, 63 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos (d) MCCB, 4 pole, 32 Amps, 50 Hz, 415 Volts, 25 KA -01 No
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 1000 Amps capacity,Out door cubical type floor mounted factory made double door dust and vermin proof fabricated out of thermoplastic polycarbonate enclosure cubicle type fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (FP 02(Offrs)
[A] INCOMING:- (a) Multifunction panel meter with CTs (b) MCCB with microprocessor based release, 4 pole, 160 AMPS, 50 Hz, 415 Volt, 25 KA - 1 No (Incoming) (B) OUTGOINGS:- (a) MCCB, 4 pole, 100 Amps, 50 Hz, 415 Volts, 25 KA -01 No (b) MCCB, 4 pole, 63 Amps, 50 Hz, 415 Volts, 25 KA -01 No (c) MCCB, 4 pole, 40 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 1000 Amps capacity,Out door cubical type floor mounted factory made double door dust and vermin proof fabricated out of thermoplastic polycarbonate enclosure cubicle type fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (Main DG Panel)
[A] INCOMING:- (a) Multifunction panel meter with CTs (b) MCCB with microprocessor based release, 4 pole, 320 AMPS, 50 Hz, 415 Volt, 35 KA - 1 No (Incoming) (B) OUTGOINGS:- (a) MCCB, 4 pole, 125 Amps, 50 Hz, 415 Volts, 25 KA -01 No (b) MCCB, 4 pole, 100 Amps, 50 Hz, 415 Volts, 25 KA -03 Nos (c) MCCB, 4 pole, 63 Amps, 50 Hz, 415 Volts, 25 KA -01 No (d) MCCB, 4 pole, 40 Amps, 50 Hz, 415 Volts, 25 KA -01 No
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 1000 Amps capacity,Out door cubical type floor mounted factory made double door dust and vermin proof fabricated out of thermoplastic polycarbonate enclosure cubicle type fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (DG Panel Sailors Md Accn)
[A] INCOMING:- (a) Multifunction panel meter with CTs (b) MCCB with microprocessor based release, 4 pole, 100 AMPS, 50 Hz, 415 Volt, 25 KA - 1 No (Incoming) (B) OUTGOINGS:- (a) MCCB, 4 pole, 32 Amps, 50 Hz, 415 Volts, 16 KA -05 Nos (b) Contactor 3 Pole 9 Amps (AC3 rating) type MX 9 of L& T cat Part No CS94015-1 No (c) Digital Time switch for 24 Hrs setting 1 phase, 15 Amps of L&T cat Part No AUTS01ANA00 - 01 No (d) Panel mounted Digital energy meter
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 1000 Amps capacity,Out door cubical type floor mounted factory made double door dust and vermin proof fabricated out of thermoplastic polycarbonate enclosure cubicle type fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (DG Panel Offrs Md Accn)
[A] INCOMING:- (a) Multifunction panel meter with CTs (b) MCCB with microprocessor based release, 4 pole, 63 AMPS, 50 Hz, 415 Volt, 25 KA - 1 No (Incoming) (B) OUTGOINGS:- (a) MCCB, 4 pole, 32 Amps, 50 Hz, 415 Volts, 16 KA -03 Nos (b) Contactor 3 Pole 9 Amps (AC3 rating)-1 No (c) Digital Time switch for 24 Hrs setting 1 phase, 15 Amps of L&T - 01 No (d) Panel mounted Digital energy meter
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 1000 Amps capacity,Out door cubical type floor mounted factory made double door dust and vermin proof fabricated out of thermoplastic polycarbonate enclosure cubicle type fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (DG Panel STP)
[A] INCOMING:- (a) Multifunction panel meter with CTs (b) MCCB with microprocessor based release, 4 pole, 100 Amps, 50 Hz, 415 Volt, 25 KA - 1 No (Incoming) (B) OUTGOINGS:- (a) MCCB, 4 pole, 63 Amps, 50 Hz, 415 Volts, 16 KA -02 Nos (b) MCCB, 4 pole, 32 Amps, 50 Hz, 415 Volts, 16 KA -02 Nos (c) Panel mounted Digital energy meter (d) MCB DP 40 A -01 No.
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 1000 Amps capacity,Out door cubical type floor mounted factory made double door dust and vermin proof fabricated out of thermoplastic polycarbonate enclosure cubicle type fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (DG Panel P/H)
[A] INCOMING:- (a) Multifunction panel meter with CTs (b) MCCB with microprocessor based release, 4 pole, 125 Amps, 50 Hz, 415 Volt, 25 KA - 1 No (Incoming) (B) OUTGOINGS:- (a) MCCB, 4 pole, 63 Amps, 50 Hz, 415 Volts, 16 KA -03 Nos (b) Star delta stater for up to 30Hp motar -02 Nos (c) Panel mounted Digital energy meter -03 Nos (d) MCB DP 40 A -01 No.
M&L for 16 meter high galvanized mast with 8 Nos, 200W 230V AC, LED flood light outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant, symmetrically fitted along with their control gear and having two point suspension system with steel wire rope of 6 mm dia and double drum winch with luminare mounting arm, aviation obstruction light, lightning arrester spike, power tools including RCC foundation as per manufacturer's instructions complete with following and as specified in particular specification: -(a) High mast fabricated from steel plates conforming to BS-EN 10025, cut and folded to from a polygonal section. Masts are in three sections for 15 Mtr heights having only longitudinal weld conforming to BS 5135/AWS. The mast is provided with a fully penetrated flange which is free from any laminations or incursions. The welded connection of the base flange is fully developed to the strength of the entire section. The base flange is provided with supplementary gussets between bolt holes to ensure elimination of helical stress concentration. For environmental protection of the mast, the entire fabricated mast is Hot Dip Galvanized (Single Dip)internally and externally, having uniform coating thickness of 85 / 65 microns for bottom / top sections respectively. (b) An adequate door opening shall be provided at the base of the mast. The opening is such that it permits clear access to equipments like winch, cable, wire rope, plug & socket etc. and also facilitates easy removal of the winch for servicing. The door opening is complete with a close fitting vandal resistant allen key locking with provision for external lock. The door opening is carefully designed and reinforced with adequate steel section so that the mast section at the base is unaffected, and undue buckling of the cut portion is prevented under heavy wind condition.
(c) Mast structure is designed to sustain an assumed maximum reaction arising from wind speed as per IS 875 (Part 3) 1987 (three seconds) which is measured at a height of 10 mtrs above ground level. (d) The high mast is provided with accessories which include a raising and lowering system (R & L), trailing cable, power tool, feeder pillar for automatic switching operation of luminaires, lighting finial and aviation obstruction warning light. (e) The R & L system will comprise of a double drum winch, SS wire ropes, head frame and lantern carriage. The winch is self lubricating and self sustaining type. It does not require any brake or clutch and has a lifting capacity of SWL 750 Kgs. (f) The wire ropes are of stainless steel grade AISI316 with minimum 6mm diameter and 7/19 construction. Its central cores is also SS and have a minimum breaking strength of 2350Kgs. The power tool is integral type suitable for handling the total head load. It has a mechanical torque limiter to ensure safety and also a manual handle is provided. (g) Feeder piller for MH fitting & cost aluminium control gear box (IP 55) shall be as per manufacture instruction. Qouted rate deemed to be inclusive of Foundation of the high mast structure as per manufacture design.
S&F solar integrated with normal electric supply stand alone LED street light fitting on galvanized aluminium alloy pole of 6M height with integrated vertical PV, 400W mono crystalline panel, Lithium Ferro Phosphate battery, charge controller and colour tempreture 6000-6500K and 6000 lumen luminaries complete all as specified and directed.
Supply and lay cable cover HV type 1 flat of size 300mm x 180mm x 40mm for cable protection all as specified and directed.
EXTERNAL/TREATED WATER SUPPLY:- Supply, install, testing and commissioning of centrifugal mono block pump set, 18 KW/25 Hp, head 48-50m, discxharge 800-1500 Lpm with SS impeller, SS shaft and mechanical seal including neccessary fixing arrangement, foundation etc all as specified and directed by Engr in charge.
Supply and lay pipe DI , Single Socketed including specials, Class K-7 , 150 mm (6") dia complete all as specified and as directed.
Supply and lay pipe DI , Single Socketed including specials, Class K-7 , 100 mm (4") dia complete all as specified and directed
Supply and lay HDPE pipe PN 20 (SDR 7.4) including fittings 80 mm (3”) dia complete all as specified and as directed
Supply and lay HDPE pipe PN 20 (SDR 7.4), including fittings 50 mm (2”) dia complete all as specified and as directed
Supply and lay HDPE pipe PN 20 (SDR 7.4), including fittings 40 mm (1.5”) dia complete all as specified and as directed.
Supply and lay HDPE pipe PN 20 (SDR 7.4), including fittings 25 mm (1”) dia complete all as specified and as directed.
Supply and fix Valves, Sluice, flanged of class PN 1.0, 150 mm (6”)dia complete all as specified and as directed.
Supply and fix Valves, Sluice, flanged of class PN 1.0, 100 mm (4”)dia complete all as specified and as directed.
Supply and fix Valves, Sluice, flanged of class PN 1.0, 80 mm (3”)dia complete all as specified and as directed.
Supply and fix Foot Valve conforming to IS 4038, 80 mm dia complete all as specified and as directed.
Supply and fix Strainer Y type conforming to IS, size 80mm dia complete all as specified and as directed..
Supply and fix Valve, reflux, with by-pass Arrangement, 80 mm (3”) dia complete all as specified and as directed.
M&L for Valve chamber 900X900X900 mm size internally built with brick work in CM 1:6 plastering complete with CM 1:4 including necessary earth work, PCC 1:4:8, 100 mm thick as in foundation concrete including provision of cast iron hinged cover with using 2mm thick steel with "FH" empossed and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fix beaching dozer bucket type of capacity 105 litre complete all as specified and as directed.
Supply, install, testing and commissioning of centrifugal mono block pump set, 7.5 Hp, head 15-24m, discxharge 450-850 Lpm with SS impeller, SS shaft and mechanical seal including neccessary fixing arrangement, foundation etc all as specified and directed by Engr in charge.
Supply and fix TV socket with metal box and top plate complete all as specified and as directed.
Supply and fix Telephone socket with metal box and top plate complete all as specified and as directed.
Supply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure 302 nod LED of Bajaj cat No BGAV 302 LED , 240 V, with timer switch and one No 10 A, MCB, SPN 230 V fixed enclousre complete all as specified and as directed..
Supply and fix electronic timer switch suitable foe 240 Volts 50Hz supply complete all as specified and as directed.
FIRE FIGHTING:- Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuilt turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved by EN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH complete all as specified and as directed.
Supply and fix branch pipe with nozzle of 20 mm dia fore hose reel conforming to IS 8090 complete all as specified and as directed.
S&F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours complete all as specified and as directed. (Cat No LSSR5W Make CG or equivalent to Bajaj/havells.
Supply and install LT control panel floor mounting outdoor type fabricated from thermoplastic polycarbonate enclosure cubicle type, and vermin proof complete with separate compartments for main and standby supplies including Aluminium bus bar of capacity 100A, and with following accessories complete all as specified and as directed:- (a) MCB TPN 32 Amps "D" curve 10 KA - 1 No (b) DOL starter - 01 No (c) Contactor suitable for 7.5 HP motor - 01 No (d) Multifunction meter - 01 No (e) Phase indicating lamps R, Y, B - 1 Set (LED type) (f) Provn for pressure switch -01 No
S&F fire extinguisher dry chemical powder (ABC) type (IS:15683) of capacity 4kg complete with installation brackets complete all as specified and as directed.
S&F fire extinguisher CO2 (light weight squeeze grip type) (IS:15683) of capacity 4.5kg complete with installation brackets complete all as specified and as directed.
Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine complying latest CPCB/NGT norms driven generator set, fully wired alternator AC to give an out put of 200 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz + 1% supply, 1500RPM, directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following:- (A) Diesel Engine:- Water cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:- Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control, engine control panel, lub oil pump, water pump. fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. (Make:- Cummins/KOEL/Greaves/Mahindra) (a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c) Corrosion inhibitor coolant (d) Paper element filters:- (i) Fuel (ii) Lube oil (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware. necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap.
(o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) Interconnecting copper cabling of adequate capacity batteries control. (r) Fuel pipe class STIC 1"/1.5" 12" dia - 01 lot (s) Self starter 12 volt DC (t) Electric operated electronic governor (u) Fuel injection pump. (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) battery voltage (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed (v) Engine hours (vi) Frequency (vii) Voltage (w) Safety control (Trip and indication) (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and altemator as per manufacturer's design alonwith AVM pads. (aa) Battery-1 No. 12 volts DC, 180AH, maintenance free battery with leads & terminals (Make- Excide/Amron) (ab) Fuel tank: 08 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed (B) Alternator- Suitable rated at 200 KVA factor, 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless excitation, screen protected, drip proof, insulation class H IP -23, self ventilated and conforming BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before (Make : KOEL/Crompton Greaves/Stamford) (C) Acoustic Enclosure:- M & L for acoustic enclosure for the above 200 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specifications :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body: 1.6mm thick CRCA (iii) Door: 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/Bajaj Crompton.
(D) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP- 52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:- (i) AMF control circuit with 4 pole MCCB 250 Amps with ultimate breaking capacity Icu-35 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity lcs=icu at 415 volts of 16 KA, thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications Incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc. Digital load manager: Three phase 4 wire indicating V.I.PF, KVA, KW, F of Enercon make withserial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase-one No. (ili) Indication lamp R, Y. B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate incoming and outgoing cables. (v) Circuit diagram plate. E) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by anufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:- The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
Design procure, installation, testing and commissioning of Grid connected Job roof top Solar power plant without battery as per MNRE guidelines,capacity not less than 5 kWp including lightning proctection, over voltage protection earthing.remot monitering etc. with following items- a) Solar Photo voltaic panel with Mono - PERC Chrysteliine half cut cells with module efficiency not less than 20% (b) Grid - tie inverter. (c) Module mounting Gl structure for SPV Module d) AC/DC distribution boxes, inter connecting cables. (d) AC/DC distribution boxes, inter connecting cables. (e) Bi-directional 3 phase DLMS type integrated meter.Minimum techinal requirements/standards for SPV Systems/Plants to be deployed as per Ministry of New and Renewable energy are manadatorily to be complied with The plan layout & schematic diagram shall be got vetted from any one of the following agencies (Approved agencies) (i) National institute of Solar energy (ii) Sardar Swarn singh National Institute of renewable energy (iii) Solar energy corporation of India (iv) The Indian renewable energy development agency. The vetting agency shall also be approve the make proposed by the contractor in his plan layout & schematic diagram.
Supply install test and commissioning of Organic waste converter, fully Job automatic, with electric motor, turfler, twin shaft shredder, gear boax, gear coupling, waste feeding hopper, stainless steel outer body having size 3.35M x1.19M x1.64M and power load 14.5W, capacity 260 kg per day including all civil and electric works all as specified and directed.
Varindera Constructions Limited
DES RAJ AND SONS BUILDERS PVT LTD
Jatan Constructions Private Limited
VRC Constructions India Pvt Ltd
Som Projects Pvt Ltd
RDS PROJECT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.