Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.1 LAccepted-AOC COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹67.5 L+₹14.4 L (27.0%)Rejected-AOC 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹84.7 L+₹31.5 L (59.2%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹86.0 L+₹32.8 L (61.7%)Rejected-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹93.6 L+₹40.4 L (76.0%)Rejected-AOC NO 23 SECOND MAIN ROAD RAJAMMAL NAGAR MADAMBAKKAM CHENNAI 600 126 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600126 | L5 | Rejected-AOC Not Lowest |
Tender Value
₹98 L
EMD Value
₹1.7 L
Closing Date
4 Jan 2021, 6:00 pmClosed
CHIEF ENGINEER HYDERABAD
CHIEF ENGINEER HYDERABAD PICKET SECUNDERABAD 500003
REPLACEMENT OF PASSANGER LIFT AT APOLLO DRDO HOSPITAL AGAINST BER LIFTS AT KANCHANBAGH HYDERABAD
2020_MES_388948_1
CERD/SEC/TOKEN/05 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D KANCHANBAGH HYDERABAD
AS PER TENDERDOCUMNTS C CLASS CAT c(ii)
8 documents required · 8 mandatory
₹1,000
GE I R AND D KANCHANBAGH HYDERABAD
₹1.7 L
Yes
24 Feb 2021
22 Oct 2020
8 Jan 2021
22 Oct 2020
4 Jan 2021
11 Nov 2020
22 Oct 2020 - 31 Oct 2020
Amount
Dismantling existing electrically operated passenger lift basement of capacity 1360kgs with Basement and G+4 floors(Total 06 floors) installed at various locations complete including control panel motors and gear boxes ,power control , trolly wiring, limit switches, levelling devices, ropes, sheaves, counter weights, with guards, buffers joists, beams, and call indicators car as a whole including all guide rails landing doors etc including any other accessories at Apollo, DRDO complex with and including shifting of old lifts to the MES store yard of AGE E/M-I Kanchanbagh, complete all as specified and directed.
Supply, install, test and commissioning of electrically operated passenger lift of carrying carry 1360kg (20 Passengers) with a speed of approximately 1.0 metre/second to serve basement to fourth floors (total of 06 floors) with AC variable voltage and variable frequency (V3F) drive system on the micro processor controlled with power driven automatic sliding door (COPD) suitable to the size of car having stainless steel panels in hairline finish No. 04, SS sliding door, PVC flooring in cabin, SS Hair line finish No. 04 ceiling, door operation automatic, entrance protection, 3D full height infra red curtain door detector system, indicators (landing / car) with DOT Matrix type direction and position indicators with stainless steel face plates (for car - full length COP shall be provided), press and speak three way intercom with speaker, SS Hand Rails in mirror finish, hall lantern (up / down) and Gong indicator arrangement, pit ladder and balustrade, over load warning signal, battery operated alarm bell and emergency light, announcement system with music, stop switch, auto cut-off car fan switch, door open and close button, Auto rescue device (ARD), do's and dont's information and minor building work, scaffolding and necessary steel items for the erection of the elevator complete all as per standard design of manufacturer with the following accessories complete all as specified and directed include the following accessories (Data sheet is enclosed as per Annexure 'I' at SL Page Nos 135&136 of tender documents ):-.
Sl. No.2.00 Contd... (a) Fire man switch (b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. (c) Battery operated emergency light (LED Ceiling fitting), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. (d) Six sleek circular LED light fitting in false ceiling. (e) One sleek circular PVC heavy duty fan in false ceiling. Make for (c) ,(d) and (e) : Phillips/Bajaj/Havells/Crompton Greaves (f) Aluminium chequered plate (3mm thick) as in flooring ,joint in chequered plate should not more than one and top covering with PVC flooring complete. g) Non stop button/independent operation. (h) Over load warning indicator both audio and visual type with tripping system having relays etc (Overload Protection/tripping system) (j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and upto a maximum time of 30 seconds. (k) Car size shall be in confirmity with IS-14655-1(2000) and body to be stainless steel of 16 guage SS mirror finish with stainless steel hand rail 38 mm hairline finish.
Sl. No.2.00 Contd… (l) Set of three in number limit swtiches at the bottom and top most poition of lift hoist ways as specified in IS (m) Hand rail 38 mm hairline finish (n) Opening with mirror of 5 mm thick with suitable size as approved by Engineer -in-charge in all the doors (Car/Landing doors) (p) Specification plate with complete details. (q) Continous earthing for machine and equipments. (r) Steel wire rope of adequate size as per relevant IS and as per manufacturer's specifications. (s) Other standard fixtures and fittings like guide rails, sleeves, counter weights with guards, buffers, gear unit brakes, control panel, locks, governor, car operational panel, power control and trailing cables complete (t) Full length display indicator panel. (u) Main drives and control shall be of latest, high effective and low power consumption. (v) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (w) Stainless steel front openable landing door with small opening for vision of size 200mm X 800mm with toughned glass not less than 8 mm thick. (x) Intercom to be connected with nearest security post.
Sl. No.2.00 Contd... NOTE:- (i) The contractor shall examine existing lift, lift well, machine room at site, before quoting the rates. Approximate size of Lift well, Pit depth and machine room are all as mentioned here-in-after. (ii) The quoted rate shall be deemed to included the cost of minor building works including making good to the disturbed surfaces to match with the existing and Scaffolding as required in lift shaft / lift well (iii) In addition to above, all systems, controls and devices as per standards, codes, acts of lift's safety norms shall be deemed to be included in quoted rate. The cost effect of testing and obtaining statutory certificate from lift inspector before commissioning by department shall be deemed to be included in the rate quoted. (iv) The lift installed shall be taken over by the department only after producing the clearance of authorized lift inspector of Telangana State / Hyderabad or officer detailed by the Accepting officer in case of no lift inspector is appointed by Telangana State /Hyderabad by bidder. The bidder has to consider this element while quoting the rates and no extra claim if any shall be entertained at a later stage. (v) Contractor shall note that the defects liability period for lift shall be two years from the certified date of completion as certified by GE(I). During the said defects liability period, the lift shall be kept functioned serviceable all the time and all consumable items shall also be provided free of cost by the contractor for satisfactory running of the lift. (vi) Car and slide doors shall be made of SS 304 grade.
Supply, laying, testing and commissioning in trenches/ ducts, fixed on walls/panels of LTUG cable, 25 Sqmm, 3.5 core, 1100 volts grade, XLPE insulated, PVC sheathed, armoured with aluminium conductor cable ISI marked, IS 7098(Part I) including lugs of required sizes complete all as specified and directed.
Supply, laying, testing and commissioning in trenches/ ducts, fixed on walls/panels of LTUG cable, 16 Sqmm, 4.0 core, 1100 volts grade, XLPE insulated, PVC sheathed, armoured with aluminium conductor cable ISI marked, IS 7098(Part I) including lugs of requied sizes complete all as specified and directed.
Supply and fix MCCB four pole 63 Amps, 415V, 50Hz with thermal magnetic release and 'Ics=100% I cu=16KA ,adjustable overload min 70% to 100% complete all as specified and directed. (For Existing Panel Board)
Factory fabricated, supply, installation, testing and commissioning of LT panel board, 3 phase, 4 wire, 415 Volts, indoor type conforming to IS/IEC-61439-1&2 with internal arc containment,IP 43 protection, epoxy painted after 7 tank surface treatment floor mounted (minimum height after foundation above the floor 20cm and width as equal or more than panel width and tight with nut and bolts with PCC), totally enclosed, cubical type, dust and vermin proof fabricated out of 2.15 mm thick CRCA sheet and suitable size section of MS angle iron frame and front openable construction, enclosure class IP - 45, powder coated including making opening for mounting meters, top/bottom removable gland plates as required hinged, double door with suitable locking system, pre-wired with suitable size of single core PVC insulated FRLS stranded copper conductor cable, 2.5 sqmm, 1100 volts graded as connecting leads and alluminium strip of 200Amp rating for connections from bus bar to MPCB, Alluminium bus bar for 3 phase and four wire system of 200 Amp rating and all connections and including PCC foundations with PCC 1:3:6 type C-1 (using 20mm graded aggregate) of above mentioned size finished even and smooth to exposed surfaces including necessary earth work suitable for comprising of the following accessories complete all as directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 25mm x 4mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 1500mm and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No. 3 of SSR Part - I (2009) connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth strip and GI protection pipe beyond 7.5metre, if required, shall be measured and paid separately under respective items of this Schedule.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc., as required, 25mm x 4mm galvanised iron strip, complete all as specified and directed.
40mm bore of pipe GI tubing light grade, galvanised with all fittings including short lengths, laid above ground level as a protection pipe to GI earth strip, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc complete all as specified and directed.
Omega Elevators
ELEVATORS MAINTENANCE ENGINEER WORKS
M/s Dhapola Elevator and Engineering
PREMIER ENGINEERING SYSTEMS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .