| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹31.0 L+₹52,952.86 (1.74%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | l3₹31.6 L+₹1.1 L (3.76%)Rejected-Finance | l3 | Rejected-Finance Other than lowest | |
| 4 | L4₹33.3 L+₹2.8 L (9.33%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹33.4 L+₹2.9 L (9.50%)Rejected-Finance 32 H I G AWAS VIKAS COLONY SECTOR 3 BODLA AGRA UP 282007 | AGRA | AGRA | UP | 282007 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹45.5 L
EMD Value
₹90,960
Closing Date
23 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Ashwin Awadh
Garrison Engineer West 62 Station Road Agra Cantt
SPECIAL REPAIR TO BLDG NO T-5 A OF STN HQ AGRA AND PROVISION OF 01 X TOILET AT STN HQ AGRA UNDER AGE B/R-I OF GE (W) AGRA
2022_MES_564845_1
8012/934/E8
Open Tender
Civil Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹90,960
31 Mar 2023
23 Nov 2022
26 Dec 2022
23 Nov 2022
23 Dec 2022
8 Dec 2022
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc with inserting precast pillers and beams into wall before demolition ete all as specified and directed by Engr in charge. (RCC pillers and beams paid separately )
Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts,columns,Beams , with or without chamfered angles and flat, splayed, rounded or mitred tops , as directed by Engr-in charge. (Rainforcement shall be paid separately)
Mild steel TMT bars 10 mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Mild steel TMT bars 6 mm to 8mm dia cut to length, bent to shape required in stirrups, spacers and binders, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings
Dismantling timber scantling 40 sqcm and over in section Un framed work in any position comlete all as spd and dir.
Dismantling timber scantling in fillets,rails,posts,rafters,purlins, etc under 40 Sq cm in section complete all as spd and dir.
S&F rolled mild steel in roof trusses, (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee,angle,channel or flat sections) including distance pieces, cleats etc conforming to Fe-410-W Gde E-250 quality A complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed self tapping screws as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
Cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregate) as in benching, coping , roof kerbs, mud stop etc and similar work including all necessary form work complete.
M&L non - skid joint free ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed.
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as directed by Engr -in-charge.
ML 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound @ 3% by weight of cement finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
Supply only integral water proofing compound liquid admixture for mortar (Make - Fosroc , Conplast WL) complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and smooth complete all as specified and directed.
M & L for rendering 10mm thick in CM 1:3 on ceiling surface finished even and fair without using extra cement complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of new plastered or un-plastered surfaces, complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed
Brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4
M & L cutting holes into or through brick wall built in cement mortar superfacial area not exc 150 Sqm cm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
M & L cutting holes into or through brick wall built in cement mortar superfacial area exc 150 Sqcm not exc 400 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S&F mild steel joist channel angle or tee sections fixed independently with out connecting plates etcof grade fe-410-0 & fe 310-0 complete all as specified and directed.
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
M&L Varoda green marble stone 16-18 mm thick in steps, pillars, wndow cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
S&F solid PVC frame of size 50x47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube supplying & fixing in opening as specified in clause No. 8B.3 at Sl page No. 145 and shown in drawing on sl page No 160 of SSR 2010 respectively and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement including 3 Nos stainless steel hinges , 100mm long , 2 Nos aluminium handle 150mm long and 2 Nos aluminium tower bolt 200mm long fixed to each shutter complete all as specified in clause No. 8B.2 at Sl page No. 143 to 144 and shown in drawing on sl page No 156 of SSR 2010 respectively and as directed.Make : Rajshree/Sintex
M&L for applying two coats of oil bound distemper on old decorated wall surfaces over 1 mm thick white putty including complete removal of existing treatment complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of 1mm thick Birla putty on new plastered surfaces complete all as specified and directed.
M&L for two coats of weather proof paint over a coat of primer over 1 mm thick wall care putty in different tint and similer works including complete removal of existing treatment and prepration of newly plastered surface complete all as specified and directed.
M&L for coloured glazed ceramic tiles (Digital & designer Pattern) in vertical surface 350 x 250 x 7 mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including 10mm thick rendering in CM 1:3 on brick wall complete all as specified and as directed .
M&L glazed ceramic non skid joint free coloured tiles (1st quality/premium quality) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exc. 0.18 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed. (bed room and other room floor)
Demolation of wall and ceiling boards ( fibre, pulp, insulation etc or insulation boards/ slabs/ blankets any thickness including cover filletts.
S & F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre. size of grid 605 mm x 605mm.
S &F Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long (removing old hangers) complete all as specified
S &F Exposed metal frame ceiling with calcium silicate board 6 mm thick if siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid (Frame work for ceiling shall be measured and paid separately)
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L 100mm thick Cement concrete 1:4:8, type D-2 ( using 40mm graded stone aggregate)as in sub-base/hard standing complete all as specified and directed.
M&L 50mm thick Cement concrete 1:2:4,type B-1 (using 20mm graded stone aggregate) as in floors/hard standing complete all as specifed and directed.
M&L for chequered cement concrete tiles 300mm X. 300mm x 25mm thick, set, jointed and pointed in near cement slurry in floor with grey cement and pigment including 20mm thick screed bed in CM (1:6) complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 Sqm each complete all as specified and directed.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each without taking off shutters from frame .
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief.
S&F 6.3 mm Sheet glass, ordinary quality and glazing with silicon rubber beadig ,clits, etc in square n exc 0.5 sq. m in each pane
S&F 6.3 mm Sheet glass, ordinary quality and glazing with silicon rubber beadig ,clits, etc in square exc 0.5 sq. m in each pane
S&F 12 mm thick Pre laminated exterior grade both side laminated board including Rubber beading , clits , etc for Aluminium partion as directed by Engr-in-charge.
S&F 100 mm Aluminium handles, cast type, anodised.
S&F 100 mm long Double action spring hinges, mild steel with steel wire spring, stove enamelled, black
S&F 100 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21
S&F Aluminium 75mm long anodised, barrel tower bolts of extruded section and fixed.
S&F Aluminium 100 mm long anodised, barrel tower bolts of extruded section and fixed.
M&L removing damaged APP modified water proofing membrane and cleaning the surface by wire brush and water complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any position n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L cement concrete type B-1, 1:2:4 mix ( 20 mm graded agg) in padding, roof kerbs or mud stops, rounded or chamfered on edges and similar work complete all as specified and directed.
Cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregate) as in benching, coping , roof kerbs, mud stop etc and similar work complete.
M & L for water proofing treatment of roof slab all as followes: - (a) M&L for preparation of roof surfaces by brushing, cleaning and Applying a priming coat with bitumen primer @ 0.5 ltr/Sqm (b) Applying a hot blown bitumen grade 85/25 @ 1.2 Kg/sqm (c) Laying APP modified water proofing membrane weighing not less than 3 Kg/Sqm will be laid over applied bitumen. (d) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and sand in confirming to Zone II in dry condition will be dusted over the bitumen @1.00 Kg/Sqm
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed.
M&L brick tiles 40 mm thick laid over 15 mm thick screed bed in CM 1:3 and jointed in CM 1:3 with linced oil @ 5% by weight of cement complete all as specified and directed.
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixing or removal to store.
S&F 15 mm bore steel water tubing medium grade galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
S&F 20mm bore steel water tubing medium grade galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
Dismantling 500 ltr water tanks and removing to store.
S&F 1000 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part
S&F 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S&F 20 mm Self-closing taps, cast copper alloy, chro-mium plated, screwed for iron pipe and fixed
S&F 20mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 300mm.
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe).
S&F Vitreous China, semi-pedestal pattern (Anglo-Indian Type).
S&F 5 litres cast iron automatic flushing cistern, including brackets
S&F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
S&F coloured Toilet paper holder, vitreous China, box type
S&F Wash basins, Vitreous China wliile, flat back of size 580x450( including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe
S&F Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device
S&F Soap dish, vitreous China white, approximate size 160x 160 x 90mm
Excavation in trenches in soft/ loose soil not exceeding 1.5 m wide n.exc 1.5m depth for fdn etc for shaft, wells, cesspits, man holes, pier holes etc. n.exc 10sqm on plan and n.exc 1.5m depth and getting out in soft loose soil.
M&L PCC 1:4:8 type D-2 (using 40mm graded crushed stone agg) as in foundation filling and mass concrete.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/ loose soil..
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point.
M&L for Rainforced cement concrete nominal mix Type B1 1:2:4 using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L Reinforced cement concrete nominal mix Type B1 1:2:4 using 20 mm graded M -25 (design Mix) Beams, cantilevers, bressummers, lintels over 1.5m span
M&L for Rainforced cement concrete nominal mix Type B1 1:2:4 using 20 mm graded aggregate in Columns, pillars, piers, posts and struts
M&L for Rainforced cement concrete nominal mix Type B1 1:2:4 using 20 mm graded aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for Rainforced cement concrete nominal mix Type B1 1:2:4 using 20 mm graded aggregate in Chajjas.
M&L for rendering 5mm thick in CM 1:4 with water proofing compound over RCC slab , RCC chajjas when it is green etc complete ( WPC will be measured and paid separately ) compete all as specified and Directed.
M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough surface complete all as sp and dir.
M & L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finished surfaces complete all as spd and dir
M & L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.fair finished surfaces complete all as spd and dir.
M & L Formwork to sides of pillars, posts, struts, piers, columns and stanchions fair surface Complete all as spd and dir.
Ditto as above but 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders
M&L 15mm thick rendering in cement mortar (1:6) on brick/concrete surfaces of walls other than fair faces complete all as specified.
M&L Rendering 5 mm thick in cement mortar (1:3) on concrete surfaces of ceiling,on fair faces finished even & smooth surfaces without using extra cement complete all as specified
M & L sand filling under floors or in fdn incl watering and consolidation complete all as spd and dir.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L glazed ceramic non skid joint free coloured tiles (1st quality/premium quality) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exc. 0.18 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed. (bed room and other room floor)
S & F Steel windows with side hung shutters including box type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with out glazing bars, dovetailed or welded complete all as specified and directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed.
S & F Mild steel work in framed work such as grills, gratings, guard bars etc, with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified & directed.
S&F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane etc complete all as directed.
S&F 3 mm thick figured glass, frosted head type and glazing with oil putty in square n exc 0.5 sq. m in each pane etc complete all as directed.
S & F Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed
M&L preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed.
M&L Two coats of cement base paint over a coat of alkali resistant priming paint as on wall including preparation of newly plastered or un plastered surface.
M&L Two coats of white wash on ceiling including preparation of newly plastered or un plastered surface.
M&L for Cement concrete type C-2 , 1:3:6 using (40mm graded aggregate) 75 mm thick as in plinth protection
S & F 15mm Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed.
S&F 15mm dia Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed. complete all as specified and directed.
S&F 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. complete all as specified and directed.
S&F 32 mm dia Waste coupling of PTMT (half or full threaded) . complete all as specified and directed.
S&F Grating round 140 mm size of PTMT. (Minimum weight 50gms) complete all as specified and directed.
S & F in 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
PVC (SWR) floor trap, plain with grating including jointing with solvent cementof 75 mm dia complete all as specified & directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified & directed.
PVC (SWR) pipes single socketed, in any length 75 mm dia with rubber ring joints, laid in trenches or in floors complete all as specified & directed.
vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe complete all as specified & directed.
S&F Vitreous China Urinal of size 465x355x265mm, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe)
S&F High density polyethylene (HDPE) pipes of 32 mm dia pipes of pressure rating 6 kgf/sq. cm complete all as specified & directed.
S& F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed.
M&L for 150 mm dia SGSW drain pipes grade ‘A’ laid in trenches and jointed in cm 1:1 complete all as specified and directed.
M&L PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for the 150mm dia of pipe complete all as specified and directed
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, to be terminated in and excluding modular metal GI flush box and its cover plates for fixing modular type switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No-130 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the same board with other switches complete all as specified & directed.
All as per item No-130 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No-130 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the Ind board with other switches complete all as specified & directed.
All as per item No-130 here in before but point wiring for one six pin socket outlet 15 & 5 amps (independent) controlled by one modular switch using PVC FRLS cable of size 2.5 sqmm complete all as specified & directed. NOTE-For item no 130 to 134 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fixing modular metal GI flush box 1/2 module as per site requirement suitable for 20mm dia conduit with and fixed on walls in CM 1:4 and making good the disturbed surfaces of walls as per existing complete all as specified and directed.
All as above item No - 135 but modular metal flush box of 3 module complete all as specified and directed.
All as above item No -135 but modular metal flush box of 4 module complete all as specified and directed.
All as above item No -135 but modular metal flush box of 6 module complete all as specified and directed.
All as above item No -135 but modular metal flush box of 2 x 6 module complete all as specified and directed.
Supply and fix modular white cover plate with frame 1 module for mounting modular switches,sockets and regulators etc complete all as specified and directed. Make: Anchor Cat No. 30726SS or equivalent as approved by GE.
All as per above item no 140 But modular white cover plate with frame 2 module complete all as specified and directed. Make: Anchor Cat No. 30737SS or equivalent as approved by GE.
All as per above item no 140 But modular white cover plate with frame 3 module complete all as specified and directed. Make: Anchor Cat No. 30748SS or equivalent as approved by GE.
All as per above item no 140 But modular white cover plate with frame 4/5 module complete all as specified and directed. Make: Anchor Cat No. 30759SS or equivalent as approved by GE.
All as per above item no 140 But modular white cover plate with frame 6 module complete all as specified and directed. Make: Anchor Cat No. 30760SS or equivalent as approved by GE.
All as per above item no 140 But modular white cover plate with frame 2x 6 module complete all as specified and directed. Make: Anchor Cat No. 35173OW or equivalent as approved by GE.
Supply and fix switch modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.21011 or equivalent as approved by GE.
Supply and fix bell push modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed. Make -Anchor CAT Part No. 21044 or equivalent as approved by GE.
Supply and fix socket outlet, 6 Amps, modular type, 2 module 230 volts complete all as specified and directed. Make: Anchor Cat No. 21102 or equivalent as approved by GE.
Supply and fix switch modular type, single pole, 16 Amps one module,one way 230 volts complete all as specified and directed. Make: Anchor Cat No.21066 or equivalent as approved by GE.
Supply and fix socket outlet, 6/16 Amps, modular type, 2 module 230 volts complete all as specified and directed. Make: Anchor Cat No.21124 or equivalent as approved by GE.
Supply & fix rotory stepped type electronic fan regulator modular type,Single module 120 watt 230 Volts complete all as specified & directed. Make:- Anchor Cat Part No. 20507 or equivalent Cona / Plaza as approved by GE.
Supply & fix commiosnig and testing of complete power cum starter unit compressing of ON/OFF switches socket 3 pin socket outlet with plug top modular type made out of white polycarbonate, fire retardant, UV stabilized power unit internally pre-wired with suitable size copper conductor cable with overload protective device (MCB) complete unit fixed in single polycarbonate housing with inlet & outlet cable port suitable for AC & geyser operated at single phase, 240 volts, 50 Hz AC supply of capacity 20 Amps load bearing capacity complete all as specified and directed. Make :- Havellls Cat Part No. DHDUCDP0253020 or equivalent model of HPL/Anchor/ Schnider/Legrand
S&F for ceiling rose surface bakelite 50 x 25 mm size 3 terminals complete all as specified and directed. Make -Anchor CAT Part No-39072 or equivalent as approved by GE.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed. Make: Anchor Cat No. 39797/ 39800 or equivalent as approved by GE.
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed. Make:- Anchor / Cona / Plaza as approved by GE.
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed. Make :- Havells cat part No-LHLDDEEEML8R015 or equivalent Model of Philips/Bajaj/CG/ Wipro as approved by GE.
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-ENDURALINEARNEOBS20WLED865SPCWH or equivalent Model of Philips/Bajaj/CG as approved by GE.
Supply & fix, surface/ ceiling mounting type 34 watt LED luminaire PLUTO NEO PENAL 2X2 environmental friendly new generation aesthetically ultra modern recess mounting with high brightness SMD LEDs as light source with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- PLR34WLED857S or equivalent model of make ,Philips/Bajaj/ Crompton Greaves as approved by GE.
Supply & fix, outdoor security light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- ENDURAPEARLNEOSL40WLED757PASYTOPC,Phillips cat part no BRP052 LED 036 CW HP SLA FG S1 PSU GR or equivalent as approved by GE.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells cat part No- LHECDEFOIH1W028 or equivalent model of make ,Philips/Bajaj/ Crompton Greaves as approved by GE.
Supply & fix surface mounting type bulkhead 10 watt LED luminaire ENDURA RUGBY NEO IP 65 environmental friendly, altra modern energy saving , decorative oval comprising of high brightness LEDs, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- Cat part No FT10WLED857SSYMBOPC or equivalent model of make Philips/ Bajaj/ Crompton Greaves as approved by GE.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor .
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down distribution boards any size any type including Change over/ MCB TPN/SPN/SP etc and making good the disturbed surfaces.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps complete all as specified & directed. Make :- L&T/Havells/Legrand/Siemens
Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 200 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed . Make:- Legrand CAT No.5077 25 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply and fix MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB. Make : Legrand cat part 4200 15 to 4200 16 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed. Make:- Legrand Cat Part No. 5076 11 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply and fixing in replacement MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed. Make:- Legrand CAT No. 4086 17 or equivalent model of make ABB/ L&T/ Schneider as approved by GE.
Supply & fix in replacement MCB SP, 2 to 4 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for light circuit) Make:- Legrand CAT No. 4085 83 to 4085 85 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply & fix in replacement MCB SP, 40 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4085 96 to 4085 98 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply & fix in replacement MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for equipment & power circuit) Make:- Legrand CAT No. 4085 87 to 4085 95 or equivalent model of make Siemens/ Schneider as approved by GE.
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repare/ servicing & painting with one coat of synthetic enable paint and re hanging/ re-fixing in original position but including replacement of three cor flexible copper conductor cable from ceiling rose to fan connector block of soze 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as directed at site by Engr-in- Charge
Supply & Laying,testing , in replacement cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 50 Sqmm 3½ core compele all as specified and as directed. Make :- Havells, Grandlay, Polycab, Finolex
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable.
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed at site by Engr- in-Charge.
Supply and fixing GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site,. Make :- TATA, Jindal, Prakash Surya
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure, complete all as specified and as directed at site,.
M/s Sharda Costruction Company
milan enterprises
PD GUPTA AND COMPANY
m/s shanti consruction co
scjha&sons
R.S BUILDERS
3Krishna Enterprises
Asha Construction
M/s RKG CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .