Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.5 LAccepted-AOC | ₹8.5 L | 1 | Accepted-AOC L1 |
| 2 | 2₹8.9 LRejected-Finance | ₹8.9 L | 2 | Rejected-Finance L2 |
| 3 | 3₹9.6 LRejected-Finance | ₹9.6 L | 3 | Rejected-Finance L3 |
| 4 | 4₹9.9 LRejected-Finance R 40 VIKAS MARG SAKAR PUR DELHI 92 | ₹9.9 L | 4 | Rejected-Finance L4 |
Tender Value
₹10.8 L
EMD Value
₹21,573
Closing Date
16 Feb 2026, 2:00 pmClosed
EXECUTIVE ENGINEER ELECTRIC NGZ
OFFICE OF THE EXECUTIVE ENGINEER ELECTRIC NGZ
Provision of Semi High Mast Poles along with allied accessories at Surya Upasna Park, in Ward No. 117, Dabri under Najafgarh Zone.EEE/NGZ/MCD/2025-26/39-01
2026_MCD_266294_1
EEE/NGZ/MCD/2025-2026/39
Open Tender
Electrical Works
Percentage
90 days
NAJAFGARH ZONE
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹21,573
16 May 2026
9 Feb 2026
16 Feb 2026
9 Feb 2026
16 Feb 2026
9 Feb 2026
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia includingaccessories, and providing masonry enclosure with cover platehaving locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing following rating four pole ,415 V ,Isolator in the existing MCB DB complete with connections ,testing and commissioning etc. as required. 63 A
P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 300x200x105mm (NS) and outer dimension of 333X233X150 mm high dome complete with suitable arrangement for fixing of 4 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd.
Supply and fabrication of pole protection system made up of 8 SWG Steel wire mash of size 25mmx75mmx rectangular with 50mmx 50mmx6mm MS angle iron for supporting the mash i/c MV danger plate and grounding the protect on system in suitable quality of CC etc
Fabrication, Supplying, Installatlon, testing, Commissloning of 12 metres seml high mast System with Its accessorles, Mast shaft shall be in one section, hot dip galvanized 4mm thick(Single dip) Inside & out sldes &sultable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For seml High Mast head frame,2 point suspension system ,5 X 2.5 sqmm Copper conductor with steel wire rope 5mm dia. (7/19 construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically and its control gears boxes and lighting finial the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPЕ pipe for cable entry & exit as required for the semi high mast considering the safe soilbearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4 Nos S.P MCB,1 no. Double pole 16Amp. MCB etc as reqd. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole. Galvanization as per relevant IS.
Providing and fixing name board made if MS Sheet 90x60cm 1mm thick with frame of MS angle 50x50x6mm two diaonal braces at the back of the sheet of MS flat 40x6mm total height of the board above ground level 2.40m lengthof legs below ground 0.30m embedded in CC block 1:2:4 (1cement: 2coarse sand: 4 graded stone aggregate 20mm nominal size ) 30x30x45cm including excavation and removal of surplus earth with in 50m lead applying priming coatof approved steel primer painting with synthetic enamel paint of approved quality and lettering wiyh enamelpaint of approved colour ( one Side) as per drawing/ direction of Engineer -in-Charge
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.lKV grade conforming to IS- 7098 of following size:- (a) 2x10sq.mm
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1 KV grade conforming to IS- 7098 /1988 of following size:- 4x25sq.mm
Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 100 Watt
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
DRAFTNIT3901.pdf
Tender Documents • 11.67 MB
GCC.pdf
Other Document • 1.97 MB
BOQ_309396.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].