Garrison Engineer Central Bangalore
Military Engineer Services Garrison Engineer Central Agram Post Bangalore PIN- 560007
REPAIR / MAINT TO WIRING AT VARIOUS LOCATIONS INCLUDING AT NANJANGU DUNDER GE CENTRAL AND REPAIR/MAINT OF CEILING FAN, EXHAUST FAN, HOT WATER SYSTEM, COOLING APPLIANCES WITH OTHER CONNECED WORKS UNDER GE (CENTRAL) BANGALORE
2022_MES_531363_3
8235E
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Central Bangalore
Please Refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Central Bangalore
₹72,000
Yes
10 Nov 2022
5 Sept 2022
28 Sept 2022
5 Sept 2022
26 Sept 2022
13 Sept 2022
5 Sept 2022 - 10 Sept 2022
Amount
Taking down copper/ aluminium point wiring(light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete.
Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade (Red Colour Cable for Phase and Black Colour Cable for Neutral), cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic conduit (Medium grade) on surface conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :- One light point controlled by one 5 Amps switch one way
All same as item No 2 above but for one fan point controlled by one 5 Amps switch one way.
All same as item No 2 above but for one bell point controlled by one switch.
All same as item No 2 above but for one 3 pin socket point 5 Amp on independent board.
All same as item No 2 above but for one 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 2 above but with 4 sqmm ( Nominal area ) cable with 4 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Point Wiring with 1.5 Sqmm (Nominal Area) PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping with Accessories (size of Casing and Capping as required at Site) including 1.50 Sqmm PVC ins-ulated Stranded Copper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly or as directed and MS terminal box with 3mm thick masonite laminated sheet top cover fixed on Wall for one light and fan point controlled by one switch complete all as specified and as directed are as follows :- One light point controlled by one 5 Amps switch one way
All same as item No 8 above but for one fan point controlled by one 5 Amps switch one way.
All same as item No 8 above but for one 3 pin socket point 5 Amp on independent board.
All same as item No 8 above but for one 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 8 above but with 4 sqmm (Nominal area) cable with 4 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Supply and fix Switch piano, flush button single pole, 5 Amps one way. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix bell push, flush button single pole, 5 Amps one way. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix in repair Switch piano, flush button single pole, 5 Amps one way. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix in repair Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose Make : Anchor/Cabtree/Legrand/Standard
Supply and fix in repair Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose Make : Anchor/Cabtree/Legrand/Standard
Supply and fix in repair modular switch 1 way 6/10A,1 module. Make : Legrand/Standard/Cabtree
Supply and fix in repairs modular switch 1 way 16A,1 module Make : Legrand/Standard/Cabtree
Supply and fix in repairs socket, 6A-2/3 pin combined 2 modules Make : Legrand/Standard/Cabtree
Supply and fix in repairs socket, 6A/16A-2/3 pin combined 2 modules Make : Legrand/Standard/Cabtree
Supply and fix in repairs moduler fan Requlator, 120 W-2 modules. Make : Legrand/Standard/Cabtree
Supply and fix in repair Door bell electronic, music type, 230 volt AC. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix in repair Fan capacitor 2.5/3.15 mfd suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix in repair Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Cabtree/Legrand/Standard
Taking down old un-serviceable light fittings of any type from wall all as directed by Engr in Charge
S&F in replacement LED tube light fitting of 10 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton Greaves/ Bajaj/ Philips/ Wipro
S&F in replacement LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton Greaves/Bajaj/ Philips/ Wipro
Supply and fix in repair 30 watt LED Light 2' x 2' LED luminare with polymer diffuser complete with accessories suitable for armstrong/Grid ceiling with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : Havells/Crompton Greaves/Bajaj/ Philips/ Wipro
S&F in replacement LED tube light fitting of 18 watts slim surface mounted 175mmX 175mm approximate size, with premium diffuser to ensure glare free & even light distribution complete with prewired and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton Greaves/Bajaj/ Philips/ Wipro
S&F in repair new generation energy saving environmental friendly long life, with high power LED building street light/security light 1x 15 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 protection and impact resistant of IK7 prewired with all accessories and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make Havells Cat No. ENDURAPEARLSL15WLED757SASYTOPCMP or equivelent of Bajaj/phillips/CG/Wipro
S&F in replacement security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and directed.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board, IP-54 protection, 4 way, vertical type ( VTPN), double door, TPN, suitable for MCCB's upto 250A as I/C , triple pole and neutral with 200 Amps rated neutral copper bus bar for housing MCCB/MCB and fixed and tested on completion complete all as specified.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board TPN, 415 volts, 4 way horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 4 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
Supply and fix in replacement MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
Supply and fix in replacement MCB single pole & neutral 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
Supply and fix in replacement MCB single pole & neutral 40/63 Amps 240 volts, C series,10 kA rupturing capacity
Supply and fix in replacement MCB Tripple pole & neutral 32 to 63 Amps 240 volts, C series, 10 kA rupturing capacity providing in DB complete all as specified.
Supply and fix in replacement Isolator TPN 100A, 415volts
Supply and fix in replacement Sub main wiring with 2 runs of 2.5 sqmm, single core, PVC insulated & unsheathed cable (FRLS) conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in new non metallic PVC grey conduit (medium grade) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. NOTE:- Two run of wiring cable, one run of earth wire and one run of PVC conduit shall be measured as one unit RM
Supply and fix in replacement Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable FRLS) conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in new non metallic PVC grey conduit (medium grade) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. NOTE:- Two run of wiring cable, one run of earth wire and one run of PVC conduit shall be measured as one unit RM
Supply and fix in replacement Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable (FRLS) conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in new non metallic PVC grey conduit (medium grade) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. NOTE:- Two run of wiring cable, one run of earth wire and one run of PVC conduit shall be measured as one unit RM. NOTE:- Two run of wiring cable, one run of earth wire and one run of PVC conduit shall be measured as one unit RM
S & F in repair ballast electronic type for 4x14 Watt FTL complete all as directed. Make Wipro/Havells/Bajaj/Crompton/C&S
S & F in repair Supply only ballast electronic type for 1x28 Watt FTL/CFL complete all as directed. Make Wipro/Havells/Bajaj/Crompton/C&S
S & F in repair Supply only ballast electronic type for 1x36 Watt FTL/CFL complete all as directed. Make Wipro/Havells/Bajaj/Crompton/C&S
S & F in repair florecsent tube rod 1x14 Watt, 65000K, high efficiency /high out put complete all as directed. Make Wipro/Havells/Bajaj/Crompton/C&S
S & F in repair florecsent tube rod 1x28 Watt, 6000K, high efficiency /high out put complete all as directed. Make Wipro/Havells/Bajaj/Crompton/C&S
S & F in repair florecsent tube rod 1x36 Watt, 6000K, high efficiency /high out put complete all as directed. Make Wipro/Havells/Bajaj/Crompton/C&S
Taking down ceiling/exhaust fan, dismantling blades and painting of ceiling/exhaust fan complete at site with synthetic enamel paint by using spraying machine, one or more coat after cleaning all dust etc incl connecting up. Provn of twin core cable of suitable size from ceiling rose to connector, connecting of earth wire incl replacement of fan capacitor 2.5/3.15 MFD,canopy, bearing/bush, rubber bushes minor nuts bolts screws washers greassing in fan bearing & refix at site same complete all as directed
Rewinding of Exhaust fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
Rewinding of ceiling fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
Supply and Fixing exhaust fan, 300mm sweep metal body, AC single phase 230/240 Volt including bird free louver shutter cut to fit with hole for exhaust fan including providing holes grouting bolts and 3 core flexible copper conductor cable of size 24/0.20 sqmm connecting up from ceiling rose to exhaust fan terminal complete all as directed. Make of fan shall be Usha/almonard/Crompton/Khaitan / Bajaj
Supply & Fixing star rated energy saving ceiling fan 1200mm sweep (white) with all accessories and hanging the ceiling fan from fan hook with 3 core flexible copper wire 24/0.20 sqmm from ceiling rose, etc all as directed. Make : Model ES-50 of Havells or equivalent in Usha/Orient.
S & F ceiling fan hook made out of MS flat 50 X 6 mm thick suitable for hanging of ceiling fan including nuts, bolts, rubber reel and washer with 12 mm dia round bar hook, painting complete all as specified and directed after taking down old one
M&L, Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 4mm dia by means of of nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified.
Removing broken hylum/laminated sheet from switch board, dismantling all switches /sockets /regulators, etc and stacking serviceable items at site for reuse, Replacing new 3mm thick masonite laminated sheet top cover, of suitable size as per site requirement with making holes for switch/sockets mounting and duly fixed all serviceable items, making necessary electrical connections in existing MS box fixing with steel screws all as directed at site by Engineer-in-charge. Note : New switches, sockets, regulators, etc against replacement will be measured and paid separately under relevant items.
Supply and fix in repair Lamp holder, insulated body, with back plate for angular/batten fittings. Make- Anchor/Cona/Kinjal.
Supply and fix in repair cable with copper conductor 1.5 Sqmm single core multistranded.
Supply and fix in repair cable with copper conductor 2.5 Sqmm single core multistranded.
Taking down carefully ceiling fan of any sweep and size and transporting to work shop,dismantling blades, opening for inspection, making joint list of defects and worn out parts to be replaced jointly by Engr-in-Charge and contractor. Reassembling after repair and replacement of spares and transporting back to sotre yard including hanging fixing and connecting up and testing etc complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement ball bearing of existing number suitable for ceiling fan 1200mm/1400mm sweep of different makes including necessary greasing all as directed by Engr-in-Charge. Make- NBC/SKF/Norma.
Supply & fix in replacement gun metal bush of existing size suitable for 1200/1400mm.
Supply & Fix in replacement U clamp with rubber reel insulator with nuts bolts of size 10mm dia 75mm long including necessary washer and split pin.
Supply & Fix in replacement flexible cord copper conductor of size 23/0.0076 twisted twin core for connection to fan from ceiling rose, including making connections complete all as specified and directed.
M&L for overhauling of ceiling fan of any make and sweep including dismantling, cleaning internally and externally and oiling, greasing, checking of electric connection.Replacement of worn out check nuts, split pins, nut,bolts,washers, sockets etc including re-assembling and testing complete all as specified and directed.
Supply & fix in replacement ball bearing of existing exhaust fan suitable for 450 to 200 mm sweep including necessary greasing all as directed. Make : SKF/NBC/Norma
Supply & fix in replacement mounting legs with rubber suitable for any type of exhaust fan.
Taking down of storage water heater (Geyser) of any size 50/35/25 ltrs capacity from existing position by disconnecting from water supply pipe line and electric connection mains to carryout necessary repairs or to deposit to E/M store yard as directed including refixing on same position after repair and making electric/water connections complete all as specified and directed by Engineer-in-Charge.
M&L for opening of storage water heater any size/make and taking out inner tank from the geyser body brazing inner tank with suitable welding rod, testing of inner tank for leakage under water pressure after brazing, reassembling geyser including repair/replacement of worn out rubber gasket nuts,bolts and testing complete and refixing in original position as specified and directed by Engr-in-Charge.
S&F in replacement 2 KW, 230 volts AC of Heating element for geyser (Round head, or Triangular head type as per types requirement at site) including rubber gasket/washer (ISI marked) complete as specified and as directed. Make: All Models of Bajaj l / Havells /Racold / venus / shakthi Note : As per at site requirement.
S&F in replacement 1.5 KW, 230 volts AC of Heating element for geyser (Round head, or Triangular head type as per types requirement at site) including rubber gasket/washer (ISI marked) complete as specified and as directed. Make: All Models of Bajaj l / Havells /Racold / venus / shakthi Note : As per at site requirement.
S&F geyser packing rubber for fixing inlet and outlet complete all as specified and directed.
S&F in replacement of stud bolt with nuts and washers set of three of geyser any type and capacity complete all as specified and directed.
S&F in replacement of Thermostat chromium plated brass ends 9 / 11 inch in lenth desinged to control the temperature of storage water heater(Geyser) single phase 230 V all as specified .
S&F in replacment of indicator lamp red/green round/rectangular shape suitable for any type & any size of geysers complete all as speified and directed.
S&F in replacement of CP connection with brass union nuts and bolts complete all as specified and directed.
S&F in replacement of 16 mm dia, 450 mm long PVC connection pipe for HOT & COLD water supply with chromium plated brass screwed nuts at bolt ends with washers for making water connections for storage water heater(Geyser) to GI tubing complete as directed .
Supply & replacement of existing unserviceable bottom cover of the geyser in two halves.
Supply & replacement of GI hexagonal nipple 150mm long, 15mm dia.
Supply & fix in replacement Plug top 3 pin 15 Amps ISI marked. Make- Anchor/CONA/Kinjal/Plaza
Supply and fix in replacement hanger bolt 100mm long and 12mm dia for mounting of geyser
S&F in replacement of sheet metal enslosure single pole and neutral with a two pin & earth plug and socket complete with 1 single pole MCB 20 Amps 'C' series 10 KA breaking capacity complete all as specified and directed. Make- Legrand/Standard/Havells.
S&F in replacement of metal clad plug top protected type 20 Amps 230 volts complete all as specified and directed. Make-Legrand/Havells/Bajaj/Standard
Supply and fix in replacement holding clamp of any type suitable for ceiling fan capacitor
Removing unserviceable cooling appliances from the position, transportating from the site to the contractor work shop for replacement of compressor, cooling coil & painting and repair work and refixing the same after repair at the same location all as per direction of Engr-in-Charge for Window type AC upto 2.0 Ton capacity
All as per item No 92 above but for split type AC upto 2.0 Ton capacity.
All as per item No 92 above but for water cooler upto 150 ltrs capacity.
All as per item No 92 above but for refrigerator upto 400 ltrs capacity.
All as per item No 92 above but for deep Freezer upto 400 ltrs capacity.
Disconnecting of suction and discharge refrigerant line to the unserviceable compressor, and replace with the new one compressor of the same make and capacity, connect the refrigerant lines, system fusing, vacummising of the entire system arrest all leakages incl M&L for charging/filling of required quantity of refrigerant gas for Window/Split type AC upto 2 ton capacity, adjusting all connected parts, testing and commissioning complete all as directed.
All as per item No 97 above but for water cooler 150 ltrs capacity
All as per item No 97 above but for water cooler 60/120 Ltrs capacity
All as per item No 97 above but for water cooler 40/80 Ltrs capacity
All as per item No 97 above but for refrigerator 310/320 Ltrs capacity
All as per item No 97 above but for refrigerator 200/280 Ltrs capacity
All as per item No 97 above but for refrigerator 180/185 Ltrs capacity
All as per item No 97 above but for deep Freezer 205/320 Ltrs capacity
Removing and replacement by providing new blower motor/fan motor of the same make and capacity, suitable for Window type AC upto 1.5 Ton capacity including re-connecting and testing complete all as per specified and directed
All as per item No 105 above but for split type AC upto 2 ton capacity
All as per item No 105 above but for water cooler upto 120/150 Ltrs capacity
All as per item No 105 above but for water cooler upto 40/80 Ltrs capacity
Servicing and maintenance of window type AC/Split AC including compressed air wash, rearranging of wires, studs or evaporator washing to condenser cooling coil/evoporator cooling coil. Air filter, front grill and make the system functional
Removing the UNSV running capacitor of 40 MFD, supply and fix of running capacitor 40 MFD suitable for 1.5 ton AC make : BHEL or equivalent.
All as per item No 111 here-in-before, but starting capacitor of 60/80 MFD for water cooler
All as per item No 111 here-in-before, but starting capacitor of 80/100 MFD for 1.5 TR/2.0 TR AC.
Replacement of unserviceable thermostat from window type AC/Split type AC upto 2.0 Ton capacity
Replacement of unserviceable thermostat from water cooler upto 150 Ltrs capacity
Replacement of unserviceable thermostat from refrigerator upto 310/320 Ltrs capacity
Dismantling of unserviceable condenser coil of Window type AC upto 1.5 Ton capacity, replace by using new condenser cooling coil for cooling appliances including system fusing vacumising and supply and filling of gas and charging testing and commissioning as directed
All as per item No 117 above but for refrigerator upto 310/320 Ltrs capacity
All as per item No 117 above but for deep freezer upto 205/320 Ltrs capacity
Taking down unserviceable fan blade from the condenser cooling motor replace new fan blade of same size and type suitable for Water cooler any type
Taking down unserviceable fan blade from the condenser cooling motor replace new fan blade of same size and type suitable for Window type AC any type
Taking down unserviceable relay box any type and capacity from refrigerator and supply and fix new relay of same make & type
Servicing/maintenance (at site) of the refrigerator checking complete wires, reconnect cleaning with compressed air to cooling coils, condenser water wash to the internal cabin of refrigerator all as directed by Engineer-in-Charge
All same as per item No 123 here-in-above but for water coolers any size any type .
All same as per item No 123 here-in-above but for Deep Freezer any size any type.
Replacement of push tap steel chromium plated of same make & type
Replacement of unserviceable float valve of any make, 15mm dia
Removing and replacement of unserviceable supply cable to the cooling appliances PVC insulated 3 core cable 1.5 sqm multi stranded copper conductor
Material and labour for body repair of Water cooler 150 Ltrs capacity by fabrication including preparation by scraping and rubbing the old painted surfaces, applying two coats of synthetic enamel over a coat of primer all as specified and directed.
Material and labour for body repair of Water cooler 40/80 Ltrs capacity by fabrication including preparation by scraping and rubbing the old painted surfaces, applying two coats of synthetic enamel over a coat of primer all as specified and directed.
Material and labour for body repair of Deep freezer upto 320/400 Ltrs capacity by fabrication including preparation by scraping and rubbing the old painted surfaces, applying two coats of synthetic enamel over a coat of primer all as specified and directed.
Taking down and replacement of unserviceable thermostat suitable for any type and capacity refrigerator/deep freezers.
Removing and repalcement of unserviceable freezer complete incl supply and filling of gas and charging etc complete all as specified and directed
Removing and replacement of over load protection by using new one for any type of refrigerator/window AC/Split type AC/Deep Freezer
Supply and fill refrigerent gas R-134 in cylinder for domestic cooling appliance.
Removing the UNSV voltage stabilizer from position, open the outer covers, removing the burnt out winding from the transformer and rewinding with super quality insulated copper winding wire of suitable size and insulating properly incl replacement of boost buck relays, assembling the stabilizer complete and fixing back in original location and testing and commissioning for 1 KVA capacity voltage stabilizer
Removing the UNSV voltage stabilizer from position, open the outer covers, removing the burnt out winding from the transformer and rewinding with super quality insulated copper winding wire of suitable size and insulating properly incl replacement of boost buck relays, assembling the stabilizer complete and fixing back in original location and testing and commissioning for 2 KVA capacity voltage stabilizer
Removing the UNSV voltage stabilizer from position, open the outer covers, removing the burnt out winding from the transformer and rewinding with super quality insulated copper winding wire of suitable size and insulating properly incl replacement of boost buck relays, assembling the stabilizer complete and fixing back in original location and testing and commissioning for 3 KVA capacity voltage stabilizer
Taking out the UNSV sensor/remote unit completely and supply and fix sensor arrangement/remote unit to suit 1.5 Ton Split type AC of makes carrier/Blue star/voltas.
Taking out the UNSV sensor/remote unit completely and supply and fix sensor arrangement/remote unit to suit 2.0 Ton Split type AC of makes carrier/Blue star/voltas.
Removing the damaged/unserviceable refrigerator magnetic gasket of door and replacing with new door gasket of same type and size incl making good the surfaces for proper sealing of the door for 165/286 ltrs capacity refrigerator.
Removing the damaged/unserviceable refrigerator magnetic gasket of door and replacing with new door gasket of same type and size incl making good the surfaces for proper sealing of the door for 286/310 ltrs capacity refrigerator.
M/S - KRUPA ELECTRICALS
B5BUILDING SOLUTIONS
ANAND REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .