Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC 100 RABINDRA SARANI NIMTA KOLKATA 700049 | KOLKATA | KOLKATA | WEST BENGAL | 700049 | ₹15.5 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹15.9 LRejected-Finance 143 C DR RAJENDRA ROAD KOLKATA 700020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | ₹15.9 L | L2 | Rejected-Finance quoting higher rate |
| 3 | L3₹16.3 LRejected-Finance 24 C GOABAGAN LANE KOLKATA 700006 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700006 | ₹16.3 L | L3 | Rejected-Finance quoting higher rate |
| 4 | L4₹17.0 LRejected-Finance | ₹17.0 L | L4 | Rejected-Finance quoting higher rate |
| 5 | L5₹19.1 LRejected-Finance 114 4 3 HAZRA ROAD KOLKATA 700026 | KOLKATA | WEST BENGAL | 700026 | ₹19.1 L | L5 | Rejected-Finance quoting higher rate |
Tender Value
₹18.2 L
EMD Value
₹36,473
Closing Date
10 Dec 2025, 1:00 pmClosed
The Executive Engineer PWD,ECD
New office Complex Building(5th Floor) Bhabani Bhawan Alipore, Kolkata 700027
Electrical Installation Work at the office spaces proposed to be located Ground floor of fourstoried Building Barrack adjacent to the left side of the staircase at Alipore Police Lines, Bhabani Bhawan, Alipore, Kolkata27 in respect of establishing
2025_WBPWD_921997_2
WBPWD/EE-ECD/e-NIT-37/2025-26
Open Tender
ELECTRICAL WORKS ORG
21 days
Alipore
please refer tender documents
5 documents required · 5 mandatory
₹36,473
O/O The Executive Engineer PWD ECD
25 May 2026
14 Nov 2025
12 Dec 2025
14 Nov 2025
10 Dec 2025
22 Nov 2025
14 Nov 2025 - 21 Nov 2025
21 Nov 2025
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. [Make:- L&T/ Havells as approved by EIC]
Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachment
4 Way (Make - L&T/Legrand/Siemens as approved by E.I.C.) [12/ D- 9 ]
e. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
4 Way Upto 160A Make - L&T/Legrand/Siemens as approved by E.I.C. [15/ D- 11 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
6 Way Make - Legrand,/Siemens/L&T as approved by E.I.C. [14/ D- 10 ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+14 Way [Legrand/ Siemens/ L&T as approved by E.I.C.] [ 13 / D- 9 & D-10 ]
40 Amps DP isolator [ 6 / D- 5 ]
63 Amps FP isolator [ 6 / D- 5 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections per GS [ (Make: Legrand/L&T/Seimens as approved by E.I.C ]
6-32 Amps SP MCB [ 7 / D- 6]
63 Amps TP MCB [ 7 / D- 6]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. [Make: Legrand/L&T/ Seimens as approved by E.I.C]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. [Make: Legrand/L&T/ Seimens as approved by E.I.C ]
4 Way Vertical [ 16 / D-12]
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA as approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed]
a) Average run 10 mtr [E-25/5(e)]
Distribution wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA as approved by E.I.C) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish
a) On Board [E-20/3(i)]
b) Average run 4.5 mtr [E-20/3(iv)]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
25 mm size [ 7(b)/ E- 16 ]
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
19 mm dia 3 mm thick polythene pipe without earth continuity wire [ 6a/ E- 3 ]
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
25 mm dia 3 mm thick polythene pipe without earth continuity wire [ 7a/ E- 3 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(brand approved by E.I.C) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
i) 3 x 22/0.3 (1.5 sqmm) [ E-9/1(b)]
ii)2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ E-9/1(s)]
iii)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ E-9/1(v)]
iv)2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [ E-9/1(y)]
v)4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [ E-9/1(g)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc.,including supplying sockets, tapes.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 4 sq mm [9(ii) / F-5]
d) 6 sq mm [9(iii) / F-5]
e) 10 sq mm [9(iv) / F-5]
f) 16 sq mm [9(v) / F-5]
g) 25 Sqmm
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 9(b) / E-18 ]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. [E-17/1]
6 module [1(b)/E-17]
Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required. [E-17/3(a)]
Supply & Fixing 240 V 16 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(b)]
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(a)]
Supply & Fixing 240 V, 6/16 A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(b)]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
175 mm x 100 mm x 65 mm [E-4/11(c)]
200 mm x 150 mm x 65 mm [E-4/11(d)]
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws
175 mm x 100 mm x 65 mm [E-5/13(c)]
200 mm x 150 mm x 65 mm [E-5/13(d)]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand Myrius/Arterior or equivalent Model of Crabtree/Roma approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a)/E-17]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Legrand Myrius/Arterior or equivalent Model of Crabtree/Roma approved by EIC) & necy. Connections [5(b)/E-17]
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20PVC insulated flexible copper wire 0.5 mt. length as per GS [ 29/C-4 ]
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2(b)]
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting [F-1/2(c)]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [F-1/2(d)]
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. [F-1/2(e)]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in loor/pavement/wall etc. [5(i)/F-3]
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. [5(ii)/F-3]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
a) By ISI-Medium GI pipe [G-1/2(a)]
Excavation of soil for installation of Earth Electrode and filling & ramming for Morrum Soil. [1(b)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12mm dia holes on the GI pipe. [ 3(a)/G-2]
Extra
for treatment of soil by using salt & charcoal or coke for plate electrode. [3(b)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
Solid GI wire.No. 4 SWG [5(a)-(i)/G-2]
Supplying and fixing compression type gland and finishing the ends of following XLPE / PVC armoured AL. cable (2/4 / 3.5)Core as per GS. [F-4 & F-5]
4 core 25 sqmm. [F-4/7(c)]& [F-5/8(b)(xv)]
4 core 50 sqmm. [F-4/7(c)]& [F-5/8(b)(xvi)]
4 core 70 sqmm. [F-4/7(c)]& [F-5/8(b)(xvii)]
4 core 95 sqmm. [F-4/7(c)]& [F-5/8(b)(xviii)]
4 core 25 sqmm
4 core 50 sqmm
4 core 70 sqmm
Single core 25 Sqmm
Supplying and fixing 32mm Dia Steel Wire Reinforced PVC Flexible pipe on wall, ceiling with saddles and other accessories as required and mending good damages to building works
Supply and installation of Sub-Main Distribution Board (SMDB) for power distribution consisting of following components : (a) 4-Way SMDB (Make : L&T, Type TN250D O/G 100A 4 Ways, cat no-DA20D1044CZZ0 or equivalent model/cat of Legrand) -- 1 no. (b)Incoming Device -160A 3-Pole MCCB (Make : L&T, Type DN1-250C 3 Pole MCCB - 160A ,cat no -CM90638OOMO or equivalent model/cat of Legrand) -- 1 no. (c) Outgoing Device - 100 A 3-Pole MCCB (Make : L&T, Type DN0- 100C 3 pole MCCB 100A , cat no -CM91612OOKOOG or equivalent model/cat of Legrand) -- 03 nos. (d) Outgoing Device - 63 A 3-Pole MCCB (Make : L&T, Type DN0- 100C 3 pole MCCB 63A , cat no -CM91612OOHOOG or equivalent model/cat of Legrand) -- 1 no.
(e) Bottom Cabling box for SMDB ( Make -: L&T type TN250D, Cat no.-CM90437OOOO or equivalent model/cat of Legrand) -- 1 no. (f) Meter Extension box for SMDB ( Make -: L&T type TN250D, Cat no.-CM90439OOPO or equivalent model/cat of Legrand) -- 1 no. (g) Side Cabling box for SMDB ( Make -: L&T type TN250D, Cat no.-CM91085ODOO or equivalent model/cat of Legrand) -- 2 nos. (h) Corner box for SMDB ( Make -: L&T type TN250D, Cat no.-CM91089OOOO or equivalent model/cat of Legrand) -- 4 nos. (i) 160/5 Amp ratio C.T (Kappa) -- 3 nos. (j) Spreader Link for Incomer MCCB ( Make:- L&T type DN250 3 pole, Cat No:- ST98053OOOO or equivalent model/cat of Legrand) [Set of 6]--- 1set (k) LCD Multifunction Digital Panel Meter [L&T cat no.-WL440511OOOO or equivalent cat of Legrand] -- 1 set (l) 1 phase LED Ammeter [L&T cat no.-WL111010OOOO or equivalent cat of Legrand] -3 set (m) 230V R.Y.B. LED indicator lamp -(SIEMENS/L&T/Legrand) ---- 3 nos. (n) 6-32 Amp SP MCB (SIEMENS/L&T BB10060C/Legrand)---- 3 nos. (n) Fixing the SMDB on wall with suitable angle iron frame grouted on wall & necessary interconnection with 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire 3 x 22/0.3 (1.5 sqmm) as per direction of EIC.
Supply and installation of L.T. industrial distribution panel board, having rigid and self supporting structure fabricated with M.S. angle iron frame (complete frame with 50 x 50 x 6 mm angle ).The panel to have arrangement for both floor & wall mounting. An Auto Cad Drawing of the panel has to approved by EIC before making of panel.
Incoming Switch :
(a) 415V 250 Amps TPN SFU units with DIN type fuses (Make:- L&T : Cat No.- SK90489 or equivalent cat of SIEMENS/ABB) in SS Encloser incl. cable gland box at top or bottom.---- 1 No.
Bus Bar :
415V, 315 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [size of flat:-4x40 mm x 5 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set.
The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) heat shrinkable insulation for colour identifications.
Outgoing Switches :
(a) 415V 160 Amps TPN SFU units with DIN type fuses (Make:- L&T : Cat No.- SK90487 or equivalent cat of SIEMENS/Legrand) in SS Encloser incl. cable gland box at top or bottom..----3 Nos.
(b) 415V 125 Amps TPN SFU units with DIN type fuses (Make:- L&T : Cat No.- SK90486 or equivalent cat of SIEMENS/Legrand) in SS Encloser incl. cable gland box at top or bottom..----1 Nos.
(c) 415V 63 Amps TPN SFU units with DIN type fuses (Make:- L&T : Cat No.- SK90484 or equivalent cat of SIEMENS/Legrand) in SS Encloser incl. cable gland box at top or bottom..- - 1 Nos.
Interconnection :-
Metering Panel a) Multipurpose Meter Digital Type Load Monitor ( Make L&T, Cat No. - WL440511OOOO or equivalent of SIEMENS/Legrand) - 1 No. b) S & F LED indicator lamp - (SIEMENS/L&T/Legrand) - 3 nos c) 200/5 Amp ratio C.T (Kappa) --- 3 nos. d) 6 Amp SPMCB(Make-SIEMENS/LT BB10060C/Legrand)---3 nos.
Earthing :-
All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.
The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :-
The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C.
All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC.
A separate continuous aluminum earth busbar of size 50mm x 6mm shall run across the full length of the panel board . All electrical equipment are to be properly earthed with suitable size G.I. wire.
S & F Timer Control unit for 1 Ph AC Machines with 12-way SPN DB Box(Mk.- L&T/Crabtree/ Legrand/Siemens/ABB) consisting of following
12 way SPN DB or Timer DB- I no
40A DP MCB Isolator-1 no
Digital 24 hrs.Time switch- I no
32A 2-pole power contactor-1no
Centre off 2-way toggle switch-1 no
32A Barrier type Terminal -1 no
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make: Legrand/L&T/ Seimens as approved by E.I.C ]
LED indicating lamp-1 no
Supply & Fixing 240V, 32A (2P+E) Industrial Sockets with enclosure with IP 44 Protection ( Make:- Legrand, Cat No- 0566 09 or eqv Model of L&T/Siemens as per Choice of EIC)
Supply of 4/3.5/2Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make:- Gloster/Havells/Polycab/RR Kabel]
Supply & Fixing 240V, 32A (2P+E) Industrial straight Plugs with IP 44, IK-09 Protection ( Make:- Legrand, Cat No- 0527 42 or eqv Model of L&T/Siemens as per Choice of EIC)
Supply and delivery of 35/36 W Indoor type 2'x2' Fullglow recessed mounting LED light fitting complete with all accessories (Make-Philips, RC380B LED42S-6500 G6 L60W60 PSUOD S1/ Wipro CRCO1ORO3OHP57G3 as approved by E.I.C)
Fixing only Ceiling light fitting on wall /ceiling by screws etc. [ 13/C-2 ]
Supply & delivery of metal body & blade wall bracket fan 18inch (1420 RPM) (make -EPC Heary Duty / Crompton 450mm ACVORTEXl8WM as approved by E.I.C).
Supply & fixing automatic single phase AC starter of 21 Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of L&T/Legrand as per dierction of E.I.C) to be fixed on 4Module GI box with all fixing accessories complete as to G.S.
Suppl
y & providing on hire basis 1 no. 415V 3-phase 125 KVA silent green DG Set in good condition of reputed make placed on suitable vehicle along with skilled operator including necessary installation accessories, connection with existing Electrical panel by providing of 1.1KV grade of 3-Run 4/3.5 core Aluminium Armoured cabel or armoured Copper cable of suitable size & length (as per direction of E.I.C) with 4nos. proper earthing arrangement for neutral & body incl. peoper socketing, cable gland etc. with suitable interconnection and provide sufficient & suitable manpower to operate the DG set etc as per requirement and dismantling the same incl. connection & resetting to original condition after the completion of the event as per instruction of EIC.
Cost of running Diesel cum Fuel consumption of the above-said DG sets.
Disconnection & dismantling existing old Electrical installation, Switch-board, wiring, Cables, Electrical fitting/fixtures etc with owns tools & takles incl. mending good damages and clearing/removing from the site as directed by EIC.
S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered/ welded with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1), including thimble joints of 7/16 SWG wire and (25 x 6) mm GI strip with SS nuts, bolts & washers. (P-J-2/Item-14 + NS)
Supply & fixing of 25 mm x 6 mm thick GI (Hot Dip) flat / strips for Horizontal & Vertical run on wall / floor with GI shaddles as required including drilling holes, bolts, nuts, washers, etc./ and mending good the damages to building works . (Page : G-3/Item-5d).
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: (P:J-1/Item-4) i) Length upto 0.5 Mtr
ii) Length above 0.5 Mtr
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. (P : J-1/Item-7)
Supply & Fixing of Testing Joints by 25 mm x 6 mm thick GI (Hot Dip) strip 125 mm long on wall after making suitable arrangement to establish a clearance of 50mm from wall for making junction connection with vertical conductor and conductor from earth electrode complete with S & F GI bolts, nuts, check-nuts, spring washers etc. as required. (J-2/Item-13)
Earthing with 65 mm dia GI pipe (TATA-Medium) 3.0 Mts. long with welded 2 nos. half circle bracket made of GI strip (65 x 8) mm. with two holes on extended portion of the each strip of length min. 250 mm , and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (G-1/Item-2d)
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. (For morum soil) (Page : G-1/Item-1b) .
Supply, Laying & Fixing of 50mm x 6mm galvanized (Hot Dip) steel strip in underground trench for interconnection between the Earth Points by joining (As per item no 11). (K-3/Item -134 + G-1/Item-1a.)
Jointing for Horijontal & vertical run of GI strip through welded joint of (25 x 6) mm or (50 x 6) mm GI Strip to Lap joints/ 'T' joints, etc. and painting the joints with 2 (two) coats of bituminous paint.
Shifting of existing 2 Nos 40KVA UPS System along with allied batteries, cables, MS Structure etc with proper care from existing server room to the proposed server room with required quantity of expert Labour as directed by EIC.
Reinstallation, testing, Commissioning of the existing 4 loop fire detection Panel (Make:- Honeywell) and making necessary connection as required including necessary Microprocessor based programing to out the system in proper operation with proper checking & functioning of existing Loops of the said panels as per direction of EIC.
Supply, Installation, Testing and Commissioning of Smoke detector with base, LPCB approved under EN 54 7:2000 (ammendment) all necessary accessories suitable for/matching with existing Fire Alarm panel with as required. (Make:- AGNI Model No:- QS 388-2L or similar product of Honeywell/Autronica/Siemens as approved by EIC)
Supply & Laying of 2 core 1.5 Sqmm FRLS shielded round copper cable (for loop) (Make:- Finolex/KEI/Polycab/RR Kabel/Mescab) through 19mm dia PVC FR type rigid conduit pipe incl. S & Laying 19mm PVC rigid Pipe. (Make:- Precesion) with necessary fixing arrangements on the surface of the wall.
Supply, Installation, Testing and Commissioning of LED type Response Indicator (VDS/UL/FM/ULC approved) having 2 nos red coloured LED Lamps including connections etc. suitable for/matching with existing Fire Alarm Panel. (Approved Make:- Honeywell/Cerberus/ Pro/ Edward/ Apollo/ Morley/ System Sensor/ Johnson Controls/ Agni/ Suraksha).
Supply, installation, testing & commissioning of (VDS/LPCB approved under EN listed/standards or UL/FM approved under NFPA listed/standards) Intelligent addressable manual call point with in-built short-circuit fault isolator as per NEPA style 7 wiring complete with all accessories as per IS-2189 of latest ammendment (Make: Honeywell / Siemens/Notofire/Jhonson Control/Edward/Secutron as approved by E.I.C)
Supply, Installation, Testing & Commissioning of (VDS/LPCB approved under EN listed/standards or UL/FM approved under NFPA listed/standards) Intelligent addressable loop powered sounder/Hooter (sound output of minimum 90db) cum strobe (having light intensity from 15 cd to110 cd) complete with all accessories as per IS-2189 of latest ammendment (Make: Honeywell / Siemens/Notofire/Jhonson Control/Edward/Secutron as approved by E.I.C)
TERMS & CONDITIONS
a.The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
b. TESTS:1.The system shall be tested and commissioned by a qualified competent,trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done.
c. Auto CAD Drawing of whole FDA system & submission of 5 set hard copy of drawing and soft copy (in Auto-CAD format) is to be submitted.
d. The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
f. If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.23 MB
Tendernotice_2.pdf
PDF • 0.51 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_2262888.xls
BOQ • 0.48 MB
enit37.pdf
Tender Documents • 1.21 MB
Download all tender documents and submit your bid