| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC 3 224 RUI KI MANDI SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.7 L+₹1.2 L (2.88%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹42.8 L+₹2.3 L (5.70%)Rejected-Finance 6 2 B 1 SHASTRI NAGAR KHANDARI AGRA UTTAR PRADESH 282002 | AGRA | UTTAR PRADESH | 282002 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹45.7 L+₹5.2 L (12.7%)Rejected-Finance 00 BEHIND CHARCH NAYAGOWAN LAKHERA BEHIND RAMA MANI DAIRY KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹46.2 L+₹5.7 L (14.1%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
17 Feb 2024, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
REPAIR/MAINT OF INTERNAL WIRING /DBs/EARTHING, LIGHTENING CONDUCTORS, MCBS, LED FITTING, MAIN CONNECTED ITEMS AT KB, MP, BP, SHERON LINE, ODF AREA, 6 PARA, 5 PARA, 411 ENGR REGT, 801 TA, 23 PARA, 50(I) PARA BDE, NCC BN, OTM ACCN OF GE (E) AGRA
2024_MES_636646_1
9632/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹1 L
Yes
23 Mar 2024
10 Jan 2024
24 Feb 2024
10 Jan 2024
17 Feb 2024
24 Jan 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for Point wiring complete with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, MS sunken boxes duly painted with one coat of red oxide and one coat of black paint not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost for the following:- (a) One light/Fan/Exhaust Fan point controlled by one switch.
All as per item No 2.00 here in before but for one 3 Pin 5 Amp Socket outlet point on an independent board.
All as per item No 2.00 here in before but one 3 Pin 5 Amp Socket outlet point on Same board with other switches.
All as per item No 2.00 here in before but One Bell/Buzzer point controlled by one push button.
All as per item No 2.00 here in before but One light point controlled by two 2 way switches.
All as per item No 2.00 here in before but with cable size FRLSH cable 4 Sq mm for one AC socket out let/ 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm all as specified and directed.
Supply and fixing switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fixing Switch piano flush button single pole one way 15 amps 240 Volts with polycarbonate body complete all as specified and directed.
Supply and fixing bell push single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fixing Switch piano flush button single pole two way 6 amps 240 Volts with polycarbonate body complete all as specified and directed.
Supply and fixing socket 5 amps 3 pin flush type, 240 volts. with polycarbonate body complete all as specified and directed.
Supply and fixing socket outlet, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
Supply and fixing call bell, Ding dong type, 230 volts AC single pole complete all as specified and directed.
S & F ceiling rose , 3 phase/PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
S & F stepped type electronic fan regulator socket type ISI marked on the existing phenolic laminated sheet etc. as required, complete all as specified and directed.
S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <18W (4 feet 18W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
Supply and fixing in repair LED luminaire 595 mm x 595 mm, 36 watt, 220 V AC, 6500 K surface/ recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting complete all as specified and directed.
Supply and fixing in replacement LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 25 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting and writing the date of fixing on security light with permt marker complete all as specified and directed. Note:-The period of defects liability shall be 02 Years from the date of installation of security light.
Supplying, fixing in replacement & testing Bulk head , luminaire made of die cast aluminium housing 10 watt LED, internally prewired with and including premium quality diffuser for glarefree light and easy to install snap fit installer complete with all accessories, and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.50 Sqmm and fixing arrangements for fixing the light fitting complete all as specified and directed.
M&L in repair for Submain wiring with two single core FRLSH 4 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified and directed. Note:- Two single core FRLSH 4 sqmm copper conductor, one run PVC conduit and one run of FRLSH 4 sqmm earth wire shall be considered & measured as one unit.
M & L in repair Submain wiring with two single core FRLSH 6 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connec-tion to earth dolly complete all as specified and directed. Note:- Two single core FRLSH 6 sqmm copper conductor, one run PVC conduit and one run of FRLSH 6 sqmm earth wire shall be considered & measured as one unit.
M & L in repair Submain wiring with two single core FRLSH 10 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall or ceiling for sub main connection including FRLSH 10 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connec-tion to earth dolly complete all as specified and directed. Note:- Two single core FRLSH 10 sqmm copper conductor, one run PVC conduit and one run of FRLSH 10 sqmm earth wire shall be considered & measured as one unit.
Supply and fixing in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, complete all as specified and directed.
Supply and fixing in repair three phase and neutral enclosure with a 3 pin and earth plug and socket complete with one MCB TPN of capacity 40-63 Amp, complete all as specified and directed.
Supply & fixing in repair of sheet metal enclosure Vertical TPN DB 4 Way double door concealed in wall as per IEC 61439-3, Suitable for Flush Mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 earthbar and Cable ties for Cable manage-ment, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for easy of installation, Prefitted masking sheet, Reversible Door for IP 54 DB's, suitable for 160 Amp MCCB as incomer and SP/TP MCB's as outgoing including cutting chasing of wall and making good the disturbed surface complete all as specified and directed.
Supply and fixing in repair MCB DB triple pole with neutral sheet metal enclosure double door type, concealed in wall, 415 Volts AC, with appropriate size bus bar of suitable size plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCBs and with enclosure blank plates for unused way suitable for 4 way ISI marked including cutting chasing of wall and making good the disturbed surface complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type concealed in wall, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 4 way ISI marked, including cutting chasing of wall and making good the disturbed surface complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, concealed in wall, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 8 way ISI marked, including cutting chasing of wall and making good the disturbed surface complete all as specified and directed.
Supply and fixing MCB TPN 40-63 Amp rating 415V, 10KA 'C' curve and current carrying ca-pacity in the MCB DB complete with connection complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection complete all as specified and directed.
Supply and fixing MCB SPN 40-63 Amp rating 240V, 10KA 'C' curve and current carrying ca-pacity in the MCB DB complete with connection complete all as specified and directed.
Supply and fixing MCCB 4 pole, 160 Amps, 50 Hz, Icu=16 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 80% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , con-nected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanised iron strip 25x4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chas-es or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated sit-uation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
Supply and fix in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix air terminal single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed.
M & L for test point terminal block made of gun metal or phosphoras bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long n.exc height head screw complete all s specified and directed
S & F aluminium strip 25x3.15 mm with saddles and fixing screw etc for roof and down conductors and above ground complete all as specified and directed.
M & L for Pre-cast cement concrete block masonary with solid blocks exc 30 cm in width and setting in mortor complete type B-1, 1:2:4 (20 mm graded aggregated) for fixing GI pipe for air termination rods) complete all as specified and directed.
Supply and fixing GI Tubes, 'Medium grade' 40mm dia complete to walls and ceilings complete all as specified and directed.
S&F porcelain insulator of required size not exceeding 10cm long with two Nos hole each on both end for fixing properly with nuts and bolts on wall of building for separated to lightening conductor or earthing strip from building all as required at site complete all as specified and directed. Note:- The distance between two insulators fixed on wall not more than 1 Mtr length complete all as specified and directed.
S & F in repair CIU for single phase prepaid elect meter complete all as specified and directed.
S & F in repair STTD for single phase prepaid elect meter complete all as specified and directed.
S&F in repair 4 Pair Telephone Cable 0.5 sqmm copper of diameter and is insulated with a special grade polyethylene compound on the latest state-of-the-art extruders. The cores are twisted together with a uniform lay from meter to CIU units, complete all as specified and directed.
S & F Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
S&F in Repair 6W ultra slim recess-mounting round LED downlighter designed with excellent thermally managed aluminium pressure die-cast housing with heat dissipating fins for larger surface area finished in epoxy powder-coated white to deliver high efficacy light output and uniformity, utilising edge-lit technology complete all as specified and directed.
S&F in Repair 6W ultra slim surface-mounting square LED downlighter designed with excellent thermally managed aluminium pressure die-cast housing with heat dissipating fins for larger surface area finished in epoxy powder-coated white to deliver high efficacy light output and uniformity, utilising edge-lit technology complete all as specified and directed.
S&F LED 8 watts bollard garden light fitting with robust IP 65 rating design and efficient light distribution including light fitting fixing and making PCC block foundation of size 300x300x300mm and connecting the fittinngs on PCC foundation block complete all as specified and directed.
Supply and fixing in replacement Geyser of 25 Ltrs capacity, 5 star rating AC single phase, 230 volts, Copper inner tank including connection with three core multistranded copper conductor of size 2.5 sqmm including necessary fixing arrangement i.e anchor nut, bolt, washer,CP pipe connection, grouting and making good to disturbed surface and cleaning of the area, complete all as specified and as directed.
M&L for re-winding of ceiling fan 1200mm/1400mm sweep which of copper winding with proper grade/gauge super enameled copper winding wire so as to achieve original specifications ie current rating and RPM (RPM test of ceiling fan with suitable tachometer will be done by contractor and shown to deptt, tachometer will be provided by contractor at their own expense) and all insulating materials supply and including replacement of ball bearing, bush & spray painting of ceiling fan including blades and reassembling etc complete all as specified and directed. Note : (i) The fans should be re-winded either of existing copper/aluminium wounded. Schedule of credit deducted as per the burnt out winding (Copper/aluminium). (ii) PVC copper flexible wire 0.75 Sqmm three core, nut bolts, washers, screws, capacitor clamp, warnising included in the quoted rate. (iii) Other connected item required like capacitors will be measured and paid separately under respective items.
Supply & fixing in replacement of defective capacitor of size 2.5 mfd ISI marked for any type of each fans suitable for 250V/230V including making connection complete all as specified and as directed.
M/S SHARADA ASOCIATE
M/S R.S. CONTRACTOR & SUPPLIER
3Krishna Enterprises
N.K. ENTERPRISES
Balaji Associates
Attar Singh and Sons
M/S VIDIT ENTERPRISES
VARDMAN ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .