| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 1 3 37 CP CHAMBERS 2ND FLOOR STREET NO 5 HABSIGUADA HYDERABAD 500 007 | HYDERABAD | HYDERABAD | TELANGANA | 500007 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
30 Jul 2026, 3:00 pmClosed
Director, TMC
Tata Memorial Hospital, Dr. E Borges Marg, Parel, Mumbai - 400012
Autostainer, Qty. 01 no. for Cytopathology Dept., TMH
2026_TMC_918962_1
TMH/TMH/2026-27/CAP/EO/0007
Open Tender
Equipments (Hospital / Lab)
EOI
Tata Memorial Hospital, Dr. E Borges Marg, Parel
As per tender Documents
1 document required · 1 mandatory
₹0
Exempted
31 Jul 2026
24 Jul 2026
31 Jul 2026
24 Jul 2026
30 Jul 2026
24 Jul 2026
24 Jul 2026 - 29 Jul 2026
Model Name:
Year of Introduction:
Year of Probable end of support:
Country of Origin:
Please quote the model which is including the latest state of art equipment and meets the required specifications. The quoted model should be latest introduced with end of support not before 10 years from the date of installation at TMC.
Sysrem should be high throughput robotic arm benchtop automated standalonw slide statiner for multiple staining applications.
Slide rack capacity should be 20 or more .
Specimen slide throughput should be atleast 200 slides/hr or more.
System should have multipe staining protocols.
Should have atleast 18 reagent stations and 4 or more water stations.
User defined program must be available.
Should have agitation progarmmable from 0 to 20 times or continuous.
Should have fume hood with filter to remove hazardous fumes.
The system should have inbuilt heating station with temperature range from 30 to 70 ℃
should have timer for adjusting time for each station.
Alarms system should be available for completion of each program.
Should have warning alarms in case of any error during operation.
Should have programmable up and down movement of robotic arm.
Should display the graphical position of each run.
Should have minimal reagent volume consumption.
Should be supplied with following consumables -
Should perform preventive maintenance (2nos) during warranty,AMC,CMC & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement.
Performance certificates of IQ,OQ,PQ tests to be submitted at the time of installation/commissioning.
Vendor to submit the technical data sheet, brochure etc as a tender document with reference to the quoted make & model. Please mention the reference page no., etc in these documents against each technical specifications in the compliance.
Vendor to submit list of consumables/consumable Spares and spare parts( i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly etc.) if any. Cost of consumables to be added in the financial bid not in the technical bid.
Please submit pre installation requirements [electrical, HVAC, Compressed air along with air pressure mentioned), water requirement (RO/DI/Distilled water with its pressure, flow rate per hour) ; if any of the above is essential]
Vendor to provide UPS with adequate capacity, if required for the quoted equipment. If not required, vendor to mention the same.
Vendor to submit details of footprint size & weight of the quoted model.
Vendor to submit power consumption.
Demo of the quoted model , will be required if so desired by the user, after the opening of the technical bid and prior to opening of financial bid. This is for technical evaluation. All technical specifications mentioned above to be mandatorily shown in the demo unit.
User's/Installation list: A list of installations of the quoted model with the address and contact numbers to be provided.
Predispatch inspection at factory will be required if desired by authorities.
Should be CE/US FDA/BIS/ICMED approved.
Vendor should provide the User manual and service manual copy during the installation of the equipment.
Unpacking and shifting the consignment to the installation site is to be included in the vendor's scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installation site. Unloading site shall be Stores department,Tata Memorial Hospital,Parel. If needed ,bidder has to arrange for the labours at no charge to Tata Memorial Hospital,Parel. (Before submitting the quotation,bidders may visit Tata Memorial Hospital,Parel. to know unloading and installation site.
Training:
Operational training to be provided onsite to all departmental staff and primary level maintenance training to be provided to inhouse Biomedical Engineers.
Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted.
Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email.
Warranty- 2 years
CMC- cost per annum will be considered for all bidders for 8 years after warranty
Warranty and CMC Should include a) 2 preventive maintenance/ year and unlimited breakdown calls along with spares.b) All bought out items quoted along with the main system (local/non-local) and UPS should be covered. c) Yearly calibration/Validation/QA, Testing and measuring equipment used should be traceable to SI units through National/ International standards (as per NABL/NABH norms). d) PM kit if any. e) All upgrades/update, no seperate licence fees will be payable.
Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted.
If 2 years warranty, CMC per annum for 8 years after warranty & buyback if any, wherever applicable are not adhered to, TMC reserves right to reject the offer.
Please mention whether UPS is required for the equipment. If so should be included in the offer.
Only Yes or No should be mentioned in compliance report and additional information in remarks column.
Please provide list of the Consumables/spares/Reagents/Control/Calibrators (if any) in Technical Documents.
Do not mention / upload price and cost in the technical documents otherwise your quotation will be disqualified at technical stage.
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
Autospec.xls
Tender Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].