Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
13 May 2026, 2:00 pmClosed
Ankit Kumar Nath
REFINERY, Bharat Petroleum Corporation Limited
TENDER TITLE “ MODULAR CONTROL ROOM INTERIOR WORKS AT IRUGUR AND DEVENGONTHI FOR IRUGUR-DEVENGONTHI PIPELINE PROJECT” Tender Ref. No. : 1000454712
25069
1000454712
Open Tender
Works
REFINERY
₹2.5 L
13 May 2026
17 Apr 2026
13 May 2026
17 Apr 2026
13 May 2026
17 Apr 2026
29 Apr 2026 - 29 Apr 2026
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Service Item 70: Unit basic rate in words ________________________________
Tempered Clear Glass Door1500mm X 2400m (Number)
"SITC of 12mm Thick Frameless Tempered Clear Glass Door
Size (±50mm) :- 1500mm X 2400mm
With door spring and locking arrangements and both way handle and patch
Specifications : Tempered glass is formed by heating glass to the softening
point in a horizontal tempering stove, and then quickly cooling it.
1) Safety (tempered): when broken, it spits into tiny harmless pieces
2) Strong intensity: heat-strengthened glass is approximately twice as strong
as annealed glass of the same thickness, and tempered glass is about 4 times
3) Outstanding performance in resisting thermal stress and wind-load
4) Tempered glass cannot be cut, drill hole and other further processed."
Service Item 80: Unit basic rate in words ________________________________
Tempered Clear Glass Door1000mm X 2400m (Number)
"SITC of 12mm Thick Frameless Tempered Clear Glass Door
Size (±50mm) :- 1000mm X 2400mm
With door spring and locking arrangements and both way handle and patch
Specifications : Tempered glass is formed by heating glass to the softening
point in a horizontal tempering stove, and then quickly cooling it.
1) Safety (tempered): when broken, it spits into tiny harmless pieces
2) Strong intensity: heat-strengthened glass is approximately twice as strong
as annealed glass of the same thickness, and tempered glass is about 4 times
3) Outstanding performance in resisting thermal stress and wind-load
4) Tempered glass cannot be cut, drill hole and other further processed."
Service Item 90: Unit basic rate in words ________________________________
Page 16 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Metal Door covered1000mm X 2400mm (Number)
"SITC of Designer Metal Door covered with Preformed Textured RIGID PVC Coated
GI Sheet:- Door Size (±50mm) : 1000mm X 2400mm
With door hinges and locking arrangements and both way handle. Prepare with
rigid thermo fused film metal panels. Specification: 0.6mm thick Metal panel
sheets, internal cavity filled with adequate quantity of honeycomb. Material
of the partition and that of metal door will remain the same. Material of the
partition and that of metal door will remain the same. The door thickness
shall be minimum 45mm and frame thickness shall be minimum 115mm."
Service Item 100: Unit basic rate in words ________________________________
SITC of Designer Metal Ceiling (SQUARE METERS)
""SITC of Designer Metal Ceiling
1) Factory made acoustic modular metal false ceiling of powder coated panels.
Make shall comprise of perforated and non-perforated metal panels made through
CNC laser Cutting, bending & punching. Panel shall be of 0.6mm CRCA sheet of
approved powder coating finish. The designer metal ceiling shall be
greenguard gold tested/certified (from UL/Intertek). Metal modular false
ceiling shall have Noise absorption coefficient (NRC) value 0.60 according to
2) It is well known that metal is resistant to fire as compared to wood &
fabric. However, from fire and safety point of view, to ensure that the used
material is not subjected to any kind of surface treatment which provokes
fire. The proposed ceiling tiles shall be Class A certified as per ASTM e84
(from UL / Intertek) for surface spread of flame and smoke generation. This is
mandatory to ensure that the materials used in the interiors do not provoke
3) To ensure restriction of hazardous substances; so that the final product
does not contaminate the environment and we give a healthy life to our coming
generations it is necessary that the modular metal ceiling system shall be
RoHS certified (from UL / Intertek). "
4) Structure shall be made from heavy duty powder coated CRCA steel sheet
(minimum sheet thickness 0.8 to 1.6mm).
5) The proposed #Acoustic Modular Designer Control Room Interiors with
Designer Metal Ceiling” should be assessed (from an authorized practitioner of
LCA) for environmental impacts associated with all the stages of a product's
life for cradle to gate with end of life.
6) The EPD of the Acoustic Modular Designer Control Room Interiors shall be
verified in accordance with ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
Page 17 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
(from UL/Intertek) for impacts on environment by Acoustic Modular Designer
Control Room Interiors with Designer Metal Ceiling.
Service Item 110: Unit basic rate in words ________________________________
SITC of Baffle ceiling (SQUARE METERS)
"SITC of Baffle ceiling
1) The baffles shall be made up of CRCA Powder Coated sheet. These baffle
planks shall be bent through CNC to have dimensions as 80X50mm or as per the
design approval or as per EIC approval. The designer baffle ceiling shall be
Greenguard Gold Certified from (UL / Intertek).
2) Centre to Centre distance shall be minimum 150mm.
3) To ensure restriction of hazardous substances; so that the final product
does not contaminate the environment and we give a healthy life to our coming
generations it is necessary that the metal ceiling system shall be RoHS
certified (from UL / Intertek).
4) It is well known that metal is resistant to fire as compared to wood &
fabric. However, from fire and safety point of view, to ensure that the used
material is not subjected to any kind of surface treatment which provokes
fire. The proposed ceiling tiles shall be class A certified as per ASTM e84
(from UL / Intertek) for surface spread of flame and smoke generation. This is
mandatory to ensure that the materials used in the interiors do not provoke
5) Specifications (Finish and component details)
5.1) Ceiling Baffle tile: minimum 0.7mm thick CRCA Powder Coated sheet."
"5.2) Carrier made of 0.60 mm CRCA steel sheet, powder coated to matching
baffle colour or black as directed by the Customer. Ceiling to have
arrangement to fix, hang and lock the baffles of required sizes and at
required intervals. the size of punched carrier would be 35x20x35mm bent
channel with holes for suspension and fixing secondary channel.
5.3) The baffles top edge will have a flange of 5mm to fix in the carrier
5.4) Mother C Channel: minimum 0.8mm thick CRCA steel Sheet with Laser cut
5.5) Suspension: The carriers would be placed at every 1200mm (maximum) and
suspended by means of a secondary angle, channel fixed to the carrier at every
900 to 1200 mm and this secondary member in turn would be suspended by 8mm rod
fixed to the slab by means of 8mm diameter, dash fastener.
5.6) Top Clamp: 1mm thick CRCA steel Sheet for holding the threaded rod.
5.7 End Cap: minimum 0.75mm thick CRCA Powder Coated sheet. End cap similar to
main ceiling baffle.
Page 18 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
5.8) Entire structure will be in powder coated CRCA sheet.
5.9) Metal Strip where baffle planks will be hanged shall be sleek & sturdy.
5.10) Color: As per approval."
Service Item 120: Unit basic rate in words ________________________________
Acoustic Metal False Ceiling with planks (SQUARE METERS)
"SITC of Designer Acoustic Metal False Ceiling with planks
1) Factory made acoustic modular metal false ceiling of powder coated panels.
Make shall comprise of perforated and non-perforated metal panels made through
CNC laser Cutting, bending & punching. Panel shall be of 0.6mm CRCA sheet of
approved powder coating finish. Panels shall be designed to achieve shape and
design as per the design consultant with the combination of acrylic panels
with lights, designed to enhance visual feel, with provision for easy
installation and maintenance, integrated lighting and scope for integration of
building services like HVAC and fire detection/ fighting system. The designer
metal ceiling shall be greenguard gold tested/certified (from UL/Intertek).
Metal modular false ceiling shall have Noise absorption coefficient (NRC)
value 0.60 according to IS:8225-1987, ISO: 354-1985 and ASTM 423-90.
2) It is well known that metal is resistant to fire as compared to wood &
fabric. However, from fire and safety point of view, to ensure that the used
material is not subjected to any kind of surface treatment which provokes
fire. The proposed ceiling tiles shall be Class A certified as per ASTM e84
(from UL / Intertek) for surface spread of flame and smoke generation. This is
mandatory to ensure that the materials used in the interiors do not provoke
3) To ensure restriction of hazardous substances; so that the final product
does not contaminate the environment and we give a healthy life to our coming
generations it is necessary that the modular metal ceiling system shall be
RoHS certified (from UL / Intertek). "
"4) To avoid dark spots/areas in the control room it is necessary that
continuous linear lights are used across the width/length of the control room.
UL audit certified design feature of integrated channel in ceiling for quick
installation & replaceability of continuous linear light: The ceiling system
having integrated inbuilt channel for installation of cove lights and shall
permit quick and easy replacement of cove light without using any tools.
Replacement to be carried out within 120 Seconds per meter.
5) Seismic safety of user & control room equipment is a prime concern area.
The metal ceiling shall sustain the seismic vibrations as per design spectrum
IS 1893 for zone 4 vibrations or better. The test shall be carried out by
authorized government agency.
6) The proposed #Acoustic Modular Designer Control Room Interiors with
Page 19 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Designer Metal Ceiling” should be assessed (from an authorized practitioner of
LCA) for environmental impacts associated with all the stages of a product's
life for cradle to gate with end of life.
7) The EPD of the Acoustic Modular Designer Control Room Interiors shall be
verified in accordance with ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
(from UL/Intertek) for impacts on environment by Acoustic Modular Designer
Control Room Interiors with Designer Metal Ceiling.
8) Structure shall be made from heavy duty powder coated CRCA steel sheet
(minimum sheet thickness 0.8 to 1.6mm)."
Service Item 130: Unit basic rate in words ________________________________
SITC of Gypsum Ceiling (SQUARE METERS)
"SITC of Gypsum Ceiling
The false ceiling shall consist of approximately 12 mm thick gypsum boards,
supported by a structure formed of GI perimeter channels. The boards shall be
affixed to the wall using wood screws and metal expansion raw plugs. The
gypsum boards are manufactured from an aerated gypsum core with
water-repellent additives, firmly bonded to strong paper liners. The surface
of the gypsum boards shall be finished with plastic emulsion paint of an
approved make and shade. The gypsum boards shall comply to below standards:
1.1) Surface Spread of Flame (BS-476 -Part-7): The boards shall be classified
as Class 1, ensuring a high level of fire resistance.
1.2) Water Absorption Class (EN-520): The boards shall meet the requirements
of Class H1, indicating efficient resistance to water absorption."
Service Item 140: Unit basic rate in words ________________________________
SITC of Round LED Ceiling Light (Static (Number)
"SITC of Round LED Ceiling Light (Static)
High performance LED downlighter with high system efficacy for good quality
and uniform lighting. Conforms to general lighting norms for office and other
indoor applications.
1) Colour Temperature (K)- 3000 K / 4000 K / 5700K (as per site conditions)
2) LED Efficacy (lm/W) # 100 to
Page 20 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
4) Power Consumption 6W to 24W
5) LED’s life >25,000 hours @ L70"
Service Item 150: Unit basic rate in words ________________________________
MASTER LED tube integrates in Baffle Cei (Number)
"SITC of MASTER LED tube integrates in Baffle Ceiling
It integrates a LED light source into a traditional fluorescent form factor.
Its unique design creates a perfectly uniform visual appearance which cannot
be distinguished from traditional fluorescent. For those that are looking for
value for money within limited budget and re-lamping efforts for better light
effect and lifetime.
1) Lumen Output - 2000 #
2) Colour Temperature (K)- 3000 K / 4000K / 6500K (as per site conditions)
3) LED’s life >25,000 hrs @ L70
5) Input Voltage Range (V) 150 -
6) LED Efficacy (lm/W) >150
7) Power Consumption (W) 20W to 32W"
Service Item 160: Unit basic rate in words ________________________________
SITC of Cove light (RUNNING METER)
"SITC of Cove light
It will be a continuous rail of LED light, high brightness, neutral, or warm
white with wall washing applications. Its slim profile and simple daisy-chain
system allows high design flexibility to form long.
1) Light source: LED
2) Lumen output: 500 lm/m
3) Light color: 6500K
4) Power consumption: 3W/m to 5W/m
5) Operating Voltage Range (V) 100 #
6) Operating Frequency (Hz) 50 ± 3%
7) Colour: White
8) Lifetime: 15000 burning hrs. (At L70)"
Page 21 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Service Item 170: Unit basic rate in words ________________________________
Wires,Switche&Conduits for Ceiling Light (SQUARE METERS)
"SITC of Wires, Switches & Conduits for Ceiling Lights
Wires for ceiling lights inter looping and switches will be provided,
consisting of PVC insulated copper conductor stranded flexible FRLS wires of
1100 volts grade of insulation in metallic conduits. Minimum size of copper
conductor shall be 1.5 sq. mm for lighting and 2.5 sqmm for power. color of
wires shall be Red/Yellow/Blue (or as per Local Standards) for the all single
phases, Black for neutral and Green for earthing."
Service Item 180: Unit basic rate in words ________________________________
Desginer Acoustic False Flooring 150mm (SQUARE METERS)
"SITC of Desginer Acoustic False Flooring 150mm
1.Mandatory - Top Surface Shall be Acoustic Laminate flooring. The designer
false flooring shall be Greenguard Gold certified from (UL / Intertek). Valid
certificate/test report to be submitted along with the technical bid.
2. Considering 150mm Height above the RCC floor
3. The flooring should be manufactured of fiber reinforced Calcium Sulphate
panels having edges finished with PVC edge band and top surface should be
finished with durable & environment friendly acoustic laminate pasted with
special glue. Tile Size should be 600mm X 600mm.
4. The Panel should
4.1. Have density of 1500KgM3.
4.2. Core material thickness should be minimum 30mm.
5. The acoustic laminate should be made up of twin-layer linoleum built up
from 2mm Laminate.
6. This false floor panel should rest on Edge support rigid grid system having
Galvanized Iron base plate dimensions as 100mm X 100mm. The stringer should be
fixed on pedestal having height adjustment of ±25mm."
Service Item 190: Unit basic rate in words ________________________________
Page 22 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Desginer Acoustic False Flooring 150mm (SQUARE METERS)
"SITC of Desginer Acoustic False Flooring 150mm
1.Mandatory - Top Surface Shall be Acoustic Laminate flooring. The designer
false flooring shall be Greenguard Gold certified from (UL / Intertek). Valid
certificate/test report to be submitted along with the technical bid.
2. Considering 150mm Height above the RCC floor
3. The flooring should be manufactured of fiber reinforced Calcium Sulphate
panels having edges finished with PVC edge band and top surface should be
finished with durable & environment friendly acoustic laminate pasted with
special glue. Tile Size should be 600mm X 600mm.
4. The Panel should
4.1. Have density of 1500KgM3.
4.2. Core material thickness should be minimum 30mm.
5. The acoustic laminate should be made up of twin-layer linoleum built up
from 2mm Laminate.
6. This false floor panel should rest on Edge support rigid grid system having
Galvanized Iron base plate dimensions as 100mm X 100mm. The stringer should be
fixed on pedestal having height adjustment of ±25mm."
Service Item 200: Unit basic rate in words ________________________________
SITC of Plastic Emulsion Paint (SQUARE METERS)
"SITC of Plastic Emulsion Paint
Painting to new walls with 3 coats of plastic emulsion paint of approved brand
and shade after thoroughly brushing the surface to remove all dirt and remains
of loose powdered materials including cost and conveyance of all materials to
work site and all operational, incidental, labour charges etc. complete for
finished item of work over one coat of primer total 3 coats."
Service Item 210: Unit basic rate in words ________________________________
SITC of Wall Putty (SQUARE METERS)
"SITC of Wall Putty
Material for 1mm thick Putty on all exposed portions of beams, columns and
walls as directed by the consultants including mixing, scraping, and levelling
Page 23 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
the surface, cleaning and complete in all respects to receive the paints &
Service Item 220: Unit basic rate in words ________________________________
SITC of Venetian Blinds (Mannual) (SQUARE METERS)
"SITC of Venetian Blinds (Mannual)
Vertical Louvre Fabric Blinds System with extruded aluminium headrail finished
in silver anodised. Operation of louvers by cord for traverse and chain for
Service Item 230: Unit basic rate in words ________________________________
State GST % : ________ % Central GST % : ________ % Integrated GST % : ________ %
Union Ter. GST % : ________ % GST Comp. Cess % : ________ %
HSN Code / SAC Code : ______________
Billing State : ______________
Grand Total (inclusive of all taxes, duties/charges etc)
Page 24 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
TERMS & CONDITIONS
Important Notice
Sr.No Description
001 Quotation received after due date will not be entertained
002 Your quotation must specify exact amount or percentage discount,
GST, Charges, Transport, Packing & forwarding,
etc. as applicable.
003 In case you are unable to quote, kindly send the quotation with a
regret for our records. Non-receipt of a regret will adversely
affect your vendor rating.
004 No quotation will be accepted without your rubber stamp and
005 Your quotation must be strictly in enclosed envelope
indicating Collective RFQ No., RFQ No. and due date.
006 For all future correspondences please mention the vendor code
Collective RFQ Number & RFQ Number.
LIST OF ENCLOSURES
Page 25 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
-------Tear off Portion to be pasted on the envelope containing offer------------
Collective RFQ No. :
Our Reference: Due Date : 28.04.2026
RFQ No. : 6001929441 Due Time : 14:00:00
Subject: MODULAR CONTROL ROOM INTERIOR WORKS FOR IDPL
Purchase Group : L21-IDPL PIPELINE PRJ
Page 26 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
To, REQUEST FOR QUOTATION
M/s. BPCL ESTIMATE Collective RFQ Number/ Purchase Group
MUMBAI . India - 400038. 1000454712 / L21-IDPL PIPELINE PRJ
Ph:,Fax:. Contact person/Telephone
Vendor Code:300648 ANKIT KUMAR NATH/-
Email:[email protected]
RFQ No/Date: 6001929441 / 15.04.2026 Quotation Due Date/Time:28.04.2026/14:00:00
Subject: MODULAR CONTROL ROOM INTERIOR WORKS FOR IDPL
Please quote your lowest prices for the supply of materials/services as per
details given below. The quotation shall show separately and clearly (without
any corrections) the basic price, discount (%), packing & forwarding (%), GST,
freight(%), other charges, etc against each item separately, as applicable.
Foreign vendors shall always quote their FOB prices against each item.
Rates/charges quoted in the quotation shall be final and no additional
charges/corrections will be accepted after the receipt of quotation unless the
same is necessitated by BPCL in writing.
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
00010 Control Room Interior works_irugur 31.07.2026
Material / Services reqd at :
M/s. CCKPL COIMBATORE
BHARAT PETROLEUM CORP. LTD.
COIMBATORE P.O.
IRUGUR COIMBATORE -
The item 00010 covers the following services:
SITC of Composite modular metal paneling (SQUARE METERS)
"SITC of Composite modular metal paneling system with PET & Modular Rigid PVC
coated GI sheet tiles
1) Factory made removable type Modular Metal Panelling system. The front sheet
shall be constructed from preformed textured hot-dip galvanized metal with a
rigid polyvinyl-chloride (PVC) film on one side and a rust-resistant coating
on the other side along with PET tiles. The metal sheet thickness shall be no
less than 0.6mm. The overall system thickness shall range between 80-90mm.The
metal panelling / partition shall be Greenguard Gold Certified from (UL /
2) The proposed #Acoustic Modular Designer Control Room Interiors with Modular
Metal Paneling should be assessed (from an authorized practitioner of LCA) for
environmental impacts associated with all the stages of a product's life for
cradle to grave with end of life.
3) The EPD of the Acoustic Modular Designer Control Room Interiors shall be
verified in accordance with ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
(from UL/Intertek) for impacts on environment by Acoustic Modular Designer
Page 1 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Control Room Interiors with Modular Metal Panelling.
4) The structural framework shall include vertical tubular galvanized iron
(GI) pipes securely installed between top and bottom GI frames.
5) The proposed non perforated wall panelling tiles shall be Class A certified
as per ASTM e84 (from UL/Intertek) for surface spread of flame and smoke
generation. This is mandatory to ensure that the materials used in the
interiors do not provoke fire."
"6) Tiles Perforation # To achieve acoustics without deteriorating the
aesthetical appeal of the Control room it is necessary that the wall panelling
shall have micro-perforations (less than 1.6mm diameter each) atleast 25% of
the panelling area with a density of 5000 holes per square feet. UL audit
certified design feature on modular wall panelling tile having clean
perforations and providing smooth finish on front fascia of tiles. The tile
shall have 5000 holes per square feet on front side of the tile.
7) The modular metal panelling shall comply to the lead-free directive to
ensure restriction of hazardous substances so that the final product does not
contaminate the environment. The final product i.e., modular metal panelling
does not contain hazardous substances and we give a healthy life to our coming
generations it is necessary that the modular metal panelling system shall be
RoHS certified (from UL / Intertek).
8) Seismic safety of user & Control room equipment is a prime concern area.
The metal panelling shall sustain the seismic vibrations as per design
spectrum IS 1893 for zone 4 or better vibrations. The test shall be carried
out by authorized government agency.
9) The wall panelling shall be robust & strong enough to sustain the routine
loads/minor impacts of typical Control room environment. The wall
panelling/partition structure shall have UL audit certified feature of Load
bearing capacity of 300 Kgs to hold any display unit on clamp having minimum
length of 750mm."
Service Item 10: Unit basic rate in words ________________________________
SITC of Composite modular metal partiti (SQUARE METERS)
"SITC of Composite modular metal partition system with PET & Modular Rigid
PVC coated GI sheet tiles
1) Factory made removable type Modular Metal Partition system. The front sheet
shall be constructed from preformed textured hot-dip galvanized metal with a
rigid polyvinyl-chloride (PVC) film on one side and a rust-resistant coating
on the other side along with PET partition tiles. The metal sheet thickness
shall be no less than 0.6mm. The overall system thickness shall range between
80-90mm.The metal panelling / partition shall be Greenguard Gold Certified
from (UL / Intertek).
Page 2 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
2) The proposed #Acoustic Modular Designer Control Room Interiors with Modular
Metal Partition should be assessed (from an authorized practitioner of LCA)
for environmental impacts associated with all the stages of a product's life
for cradle to grave with end of life.
3) The EPD of the Acoustic Modular Designer Control Room Interiors shall be
verified in accordance with ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
(from UL/Intertek) for impacts on environment by Acoustic Modular Designer
Control Room Interiors with Modular Metal Panelling.
4) The structural framework shall include vertical tubular galvanized iron
(GI) pipes securely installed between top and bottom GI frames.
5) The proposed non perforated wall partition tiles shall be Class A certified
as per ASTM e84 (from UL/Intertek) for surface spread of flame and smoke
generation. This is mandatory to ensure that the materials used in the
interiors do not provoke fire.
"6) Tiles Perforation # To achieve acoustics without deteriorating the
aesthetical appeal of the Control room it is necessary that the wall partition
shall have micro-perforations (less than 1.6mm diameter each) atleast 25% of
the partition area with a density of 5000 holes per square feet. UL audit
certified design feature on modular wall partition tile having clean
perforations and providing smooth finish on front fascia of tiles. The tile
shall have 5000 holes per square feet on front side of the tile.
7) The modular metal partition shall comply to the lead-free directive to
ensure restriction of hazardous substances so that the final product does not
contaminate the environment. The final product i.e., modular metal panelling
does not contain hazardous substances and we give a healthy life to our coming
generations it is necessary that the modular metal partition system shall be
RoHS certified (from UL / Intertek).
8) Seismic safety of user & Control room equipment is a prime concern area.
The metal partition shall sustain the seismic vibrations as per design
spectrum IS 1893 for zone 4 or better vibrations. The test shall be carried
out by authorized government agency.
9) The wall partition shall be robust & strong enough to sustain the routine
loads/minor impacts of typical Control room environment. The wall
panelling/partition structure shall have UL audit certified feature of Load
bearing capacity of 300 Kgs to hold any display unit on clamp having minimum
length of 750mm."
Service Item 20: Unit basic rate in words ________________________________
SITC of Straight Glass Partition Materia (SQUARE METERS)
"SITC of Straight Glass Partition Material (12mm thick toughened glass)
Page 3 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
(Maximum Height 3m)
1) Full height glass partitions walls shall be made of 12mm toughened glass
with frame-less structure. Proper structure shall be made to ensure the fixing
of glass from RCC slab above false ceiling and holding channels on flooring.
2) Straight and vertical structural members shall not be visible. Glass shall
be fitted on extrusion with tool less technology.
3) NOTE: - The nature of installation shall be replaceable, expandable and
flexible to cater the future expansion/technical up-gradation." "Supply and
Installation of Straight Glass Partition Material: - (12 mm thick toughened
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification." "Supply and Installation of
Straight Glass Partition Material: - (12 mm thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification." "Supply and Installation of
Straight Glass Partition Material: - (12 mm thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification." "Supply and Installation of
Straight Glass Partition Material: - (12 mm thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification."
Service Item 30: Unit basic rate in words ________________________________
SIT_Frameless Tempered Clear Glass door (Number)
"SITC of 12mm Thick Frameless Tempered Clear Glass Door
Size (±50mm) :- 1500mm X 2400mm
With door spring and locking arrangements and both way handle and patch
Specifications : Tempered glass is formed by heating glass to the softening
Page 4 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
point in a horizontal tempering stove, and then quickly cooling it.
1) Safety (tempered): when broken, it spits into tiny harmless pieces
2) Strong intensity: heat-strengthened glass is approximately twice as strong
as annealed glass of the same thickness, and tempered glass is about 4 times
3) Outstanding performance in resisting thermal stress and wind-load
4) Tempered glass cannot be cut, drill hole and other further processed."
Service Item 40: Unit basic rate in words ________________________________
Metal Door covered2000mm X 2400mm (Number)
"SITC of Designer Metal Door covered with Preformed Textured RIGID PVC Coated
GI Sheet:- Door Size (±50mm) : 2000mm X 2400mm
With door hinges and locking arrangements and both way handle. Prepare with
rigid thermo fused film metal panels. Specification: 0.6mm thick Metal panel
sheets, internal cavity filled with adequate quantity of honeycomb. Material
of the partition and that of metal door will remain the same. Material of the
partition and that of metal door will remain the same. The door thickness
shall be minimum 45mm and frame thickness shall be minimum 115mm."
Service Item 50: Unit basic rate in words ________________________________
Metal Door covered1000mm X 2400mm (Number)
"SITC of Designer Metal Door covered with Preformed Textured RIGID PVC Coated
GI Sheet:- Door Size (±50mm) : 1000mm X 2400mm
With door hinges and locking arrangements and both way handle. Prepare with
rigid thermo fused film metal panels. Specification: 0.6mm thick Metal panel
sheets, internal cavity filled with adequate quantity of honeycomb. Material
of the partition and that of metal door will remain the same. Material of the
partition and that of metal door will remain the same. The door thickness
shall be minimum 45mm and frame thickness shall be minimum 115mm."
Service Item 60: Unit basic rate in words ________________________________
Page 5 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Acoustic Metal False Ceiling with planks (SQUARE METERS)
"SITC of Designer Acoustic Metal False Ceiling with planks
1) Factory made acoustic modular metal false ceiling of powder coated panels.
Make shall comprise of perforated and non-perforated metal panels made through
CNC laser Cutting, bending & punching. Panel shall be of 0.6mm CRCA sheet of
approved powder coating finish. Panels shall be designed to achieve shape and
design as per the design consultant with the combination of acrylic panels
with lights, designed to enhance visual feel, with provision for easy
installation and maintenance, integrated lighting and scope for integration of
building services like HVAC and fire detection/ fighting system. The designer
metal ceiling shall be greenguard gold tested/certified (from UL/Intertek).
Metal modular false ceiling shall have Noise absorption coefficient (NRC)
value 0.60 according to IS:8225-1987, ISO: 354-1985 and ASTM 423-90.
2) It is well known that metal is resistant to fire as compared to wood &
fabric. However, from fire and safety point of view, to ensure that the used
material is not subjected to any kind of surface treatment which provokes
fire. The proposed ceiling tiles shall be Class A certified as per ASTM e84
(from UL / Intertek) for surface spread of flame and smoke generation. This is
mandatory to ensure that the materials used in the interiors do not provoke
3) To ensure restriction of hazardous substances; so that the final product
does not contaminate the environment and we give a healthy life to our coming
generations it is necessary that the modular metal ceiling system shall be
RoHS certified (from UL / Intertek). "
"4) To avoid dark spots/areas in the control room it is necessary that
continuous linear lights are used across the width/length of the control room.
UL audit certified design feature of integrated channel in ceiling for quick
installation & replaceability of continuous linear light: The ceiling system
having integrated inbuilt channel for installation of cove lights and shall
permit quick and easy replacement of cove light without using any tools.
Replacement to be carried out within 120 Seconds per meter.
5) Seismic safety of user & control room equipment is a prime concern area.
The metal ceiling shall sustain the seismic vibrations as per design spectrum
IS 1893 for zone 4 vibrations or better. The test shall be carried out by
authorized government agency.
6) The proposed #Acoustic Modular Designer Control Room Interiors with
Designer Metal Ceiling” should be assessed (from an authorized practitioner of
LCA) for environmental impacts associated with all the stages of a product's
life for cradle to gate with end of life.
7) The EPD of the Acoustic Modular Designer Control Room Interiors shall be
verified in accordance with ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
(from UL/Intertek) for impacts on environment by Acoustic Modular Designer
Control Room Interiors with Designer Metal Ceiling.
8) Structure shall be made from heavy duty powder coated CRCA steel sheet
(minimum sheet thickness 0.8 to 1.6mm)."
Page 6 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Service Item 70: Unit basic rate in words ________________________________
SITC of Designer Metal Ceiling (SQUARE METERS)
"SITC of Designer Metal Ceiling
1) Factory made acoustic modular metal false ceiling of powder coated panels.
Make shall comprise of perforated and non-perforated metal panels made through
CNC laser Cutting, bending & punching. Panel shall be of 0.6mm CRCA sheet of
approved powder coating finish. The designer metal ceiling shall be
greenguard gold tested/certified (from UL/Intertek). Metal modular false
ceiling shall have Noise absorption coefficient (NRC) value 0.60 according to
2) It is well known that metal is resistant to fire as compared to wood &
fabric. However, from fire and safety point of view, to ensure that the used
material is not subjected to any kind of surface treatment which provokes
fire. The proposed ceiling tiles shall be Class A certified as per ASTM e84
(from UL / Intertek) for surface spread of flame and smoke generation. This is
mandatory to ensure that the materials used in the interiors do not provoke
3) To ensure restriction of hazardous substances; so that the final product
does not contaminate the environment and we give a healthy life to our coming
generations it is necessary that the modular metal ceiling system shall be
RoHS certified (from UL / Intertek). "
"4) Structure shall be made from heavy duty powder coated CRCA steel sheet
(minimum sheet thickness 0.8 to 1.6mm).
5) The proposed #Acoustic Modular Designer Control Room Interiors with
Designer Metal Ceiling” should be assessed (from an authorized practitioner of
LCA) for environmental impacts associated with all the stages of a product's
life for cradle to gate with end of life.
6) The EPD of the Acoustic Modular Designer Control Room Interiors shall be
verified in accordance with ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
(from UL/Intertek) for impacts on environment by Acoustic Modular Designer
Control Room Interiors with Designer Metal Ceiling.
Service Item 80: Unit basic rate in words ________________________________
SITC of Gypsum Ceiling (SQUARE METERS)
Page 7 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
"SITC of Gypsum Ceiling
The false ceiling shall consist of approximately 12 mm thick gypsum boards,
supported by a structure formed of GI perimeter channels. The boards shall be
affixed to the wall using wood screws and metal expansion raw plugs. The
gypsum boards are manufactured from an aerated gypsum core with
water-repellent additives, firmly bonded to strong paper liners. The surface
of the gypsum boards shall be finished with plastic emulsion paint of an
approved make and shade. The gypsum boards shall comply to below standards:
1.1) Surface Spread of Flame (BS-476 -Part-7): The boards shall be classified
as Class 1, ensuring a high level of fire resistance.
1.2) Water Absorption Class (EN-520): The boards shall meet the requirements
of Class H1, indicating efficient resistance to water absorption."
Service Item 90: Unit basic rate in words ________________________________
SITC of Round LED Ceiling Light (Static (Number)
Service Item 100: Unit basic rate in words ________________________________
SITC of Cove light (RUNNING METER)
"SITC of Cove light
It will be a continuous rail of LED light, high brightness, neutral, or warm
white with wall washing applications. Its slim profile and simple daisy-chain
system allows high design flexibility to form long.
1) Light source: LED
2) Lumen output: 500 lm/m
3) Light color: 6500K
4) Power consumption: 3W/m to 5W/m
5) Operating Voltage Range (V) 100 #
6) Operating Frequency (Hz) 50 ± 3%
7) Colour: White
8) Lifetime: 15000 burning hrs. (At L70)"
Service Item 110: Unit basic rate in words ________________________________
Page 8 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Wires,Switche&Conduits for Ceiling Light (SQUARE METERS)
Service Item 120: Unit basic rate in words ________________________________
Desginer Acoustic False Flooring 150mm (SQUARE METERS)
Service Item 130: Unit basic rate in words ________________________________
SITC of Plastic Emulsion Paint (SQUARE METERS)
"SITC of Plastic Emulsion Paint
Painting to new walls with 3 coats of plastic emulsion paint of approved brand
and shade after thoroughly brushing the surface to remove all dirt and remains
of loose powdered materials including cost and conveyance of all materials to
work site and all operational, incidental, labour charges etc. complete for
finished item of work over one coat of primer total 3 coats."
Service Item 140: Unit basic rate in words ________________________________
SITC of Wall Putty (SQUARE METERS)
"SITC of Wall Putty
Material for 1mm thick Putty on all exposed portions of beams, columns and
walls as directed by the consultants including mixing, scraping, and levelling
the surface, cleaning and complete in all respects to receive the paints &
Service Item 150: Unit basic rate in words ________________________________
Page 9 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
SITC of Venetian Blinds (Mannual) (SQUARE METERS)
"SITC of Venetian Blinds (Mannual)
Vertical Louvre Fabric Blinds System with extruded aluminium headrail finished
in silver anodised. Operation of louvers by cord for traverse and chain for
Service Item 160: Unit basic rate in words ________________________________
State GST % : ________ % Central GST % : ________ % Integrated GST % : ________ %
Union Ter. GST % : ________ % GST Comp. Cess % : ________ %
HSN Code / SAC Code : ______________
Billing State : ______________
00020 Control Room InteriorI works_Devangonthi 31.07.2026
Material / Services reqd at :
M/s. IDPL Devangonthi PPL Plant
BHARAT PETROLEUM CORP. LTD.
Devangonthi Installation,
Near Railway Station,Devangonthi
Devangonthi BANGALORE-RUR -
The item 00020 covers the following services:
SITC of Composite modular metal paneling (SQUARE METERS)
"SITC of Composite modular metal paneling system with PET & Modular Rigid PVC
coated GI sheet tiles
1) Factory made removable type Modular Metal Panelling system. The front sheet
shall be constructed from preformed textured hot-dip galvanized metal with a
rigid polyvinyl-chloride (PVC) film on one side and a rust-resistant coating
on the other side along with PET tiles. The metal sheet thickness shall be no
less than 0.6mm. The overall system thickness shall range between 80-90mm.The
metal panelling / partition shall be Greenguard Gold Certified from (UL /
Page 10 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
2) The proposed #Acoustic Modular Designer Control Room Interiors with Modular
Metal Paneling should be assessed (from an authorized practitioner of LCA) for
environmental impacts associated with all the stages of a product's life for
cradle to grave with end of life.
3) The EPD of the Acoustic Modular Designer Control Room Interiors shall be
verified in accordance with ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
(from UL/Intertek) for impacts on environment by Acoustic Modular Designer
Control Room Interiors with Modular Metal Panelling.
4) The structural framework shall include vertical tubular galvanized iron
(GI) pipes securely installed between top and bottom GI frames.
5) The proposed non perforated wall panelling tiles shall be Class A certified
as per ASTM e84 (from UL/Intertek) for surface spread of flame and smoke
generation. This is mandatory to ensure that the materials used in the
interiors do not provoke fire."
"6) Tiles Perforation # To achieve acoustics without deteriorating the
aesthetical appeal of the Control room it is necessary that the wall panelling
shall have micro-perforations (less than 1.6mm diameter each) atleast 25% of
the panelling area with a density of 5000 holes per square feet. UL audit
certified design feature on modular wall panelling tile having clean
perforations and providing smooth finish on front fascia of tiles. The tile
shall have 5000 holes per square feet on front side of the tile.
7) The modular metal panelling shall comply to the lead-free directive to
ensure restriction of hazardous substances so that the final product does not
contaminate the environment. The final product i.e., modular metal panelling
does not contain hazardous substances and we give a healthy life to our coming
generations it is necessary that the modular metal panelling system shall be
RoHS certified (from UL / Intertek).
8) Seismic safety of user & Control room equipment is a prime concern area.
The metal panelling shall sustain the seismic vibrations as per design
spectrum IS 1893 for zone 4 or better vibrations. The test shall be carried
out by authorized government agency.
9) The wall panelling shall be robust & strong enough to sustain the routine
loads/minor impacts of typical Control room environment. The wall
panelling/partition structure shall have UL audit certified feature of Load
bearing capacity of 300 Kgs to hold any display unit on clamp having minimum
length of 750mm."
Service Item 10: Unit basic rate in words ________________________________
SITC of Composite modular metal partiti (SQUARE METERS)
"SITC of Composite modular metal partition system with PET & Modular Rigid
PVC coated GI sheet tiles
Page 11 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
1) Factory made removable type Modular Metal Partition system. The front sheet
shall be constructed from preformed textured hot-dip galvanized metal with a
rigid polyvinyl-chloride (PVC) film on one side and a rust-resistant coating
on the other side along with PET partition tiles. The metal sheet thickness
shall be no less than 0.6mm. The overall system thickness shall range between
80-90mm.The metal panelling / partition shall be Greenguard Gold Certified
from (UL / Intertek).
2) The proposed #Acoustic Modular Designer Control Room Interiors with Modular
Metal Partition should be assessed (from an authorized practitioner of LCA)
for environmental impacts associated with all the stages of a product's life
for cradle to grave with end of life.
3) The EPD of the Acoustic Modular Designer Control Room Interiors shall be
verified in accordance with ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
(from UL/Intertek) for impacts on environment by Acoustic Modular Designer
Control Room Interiors with Modular Metal Panelling.
4) The structural framework shall include vertical tubular galvanized iron
(GI) pipes securely installed between top and bottom GI frames.
5) The proposed non perforated wall partition tiles shall be Class A certified
as per ASTM e84 (from UL/Intertek) for surface spread of flame and smoke
generation. This is mandatory to ensure that the materials used in the
interiors do not provoke fire.
"6) Tiles Perforation # To achieve acoustics without deteriorating the
aesthetical appeal of the Control room it is necessary that the wall partition
shall have micro-perforations (less than 1.6mm diameter each) atleast 25% of
the partition area with a density of 5000 holes per square feet. UL audit
certified design feature on modular wall partition tile having clean
perforations and providing smooth finish on front fascia of tiles. The tile
shall have 5000 holes per square feet on front side of the tile.
7) The modular metal partition shall comply to the lead-free directive to
ensure restriction of hazardous substances so that the final product does not
contaminate the environment. The final product i.e., modular metal panelling
does not contain hazardous substances and we give a healthy life to our coming
generations it is necessary that the modular metal partition system shall be
RoHS certified (from UL / Intertek).
8) Seismic safety of user & Control room equipment is a prime concern area.
The metal partition shall sustain the seismic vibrations as per design
spectrum IS 1893 for zone 4 or better vibrations. The test shall be carried
out by authorized government agency.
9) The wall partition shall be robust & strong enough to sustain the routine
loads/minor impacts of typical Control room environment. The wall
panelling/partition structure shall have UL audit certified feature of Load
bearing capacity of 300 Kgs to hold any display unit on clamp having minimum
length of 750mm."
Page 12 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
Service Item 20: Unit basic rate in words ________________________________
SITC of Gypsum Ceiling (SQUARE METERS)
"SITC of Gypsum Panelling
Gypsum paneling/partition material with paint for top finish. The gypsum board
panels shall be fixed with screws on single side (for paneling) & both sides
(for partition) of G.I frame.
The structure is made up of GI stud and GI Channel. The GI channel’s thickness
shall be minimum 0.5mm and 120 (GSM) Galvanizing.
Service Item 30: Unit basic rate in words ________________________________
SITC of Gypsum Partition (SQUARE METERS)
"SITC of Gypsum Partition
Gypsum partition material with paint for top finish. The gypsum board panels
shall be fixed with screws on both sides (for partition) of G.I frame. The
structure is made up of GI stud and GI Channel. The GI channel’s thickness
shall be minimum 0.5mm and 120 (GSM) Galvanizing.
Service Item 40: Unit basic rate in words ________________________________
SITC of Straight Glass Partition Materia (SQUARE METERS)
"SITC of Straight Glass Partition Material (12mm thick toughened glass)
(Maximum Height 3m)
1) Full height glass partitions walls shall be made of 12mm toughened glass
with frame-less structure. Proper structure shall be made to ensure the fixing
of glass from RCC slab above false ceiling and holding channels on flooring.
2) Straight and vertical structural members shall not be visible. Glass shall
be fitted on extrusion with tool less technology.
3) NOTE: - The nature of installation shall be replaceable, expandable and
Page 13 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
flexible to cater the future expansion/technical up-gradation." "Supply and
Installation of Straight Glass Partition Material: - (12 mm thick toughened
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification." "Supply and Installation of
Straight Glass Partition Material: - (12 mm thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification." "Supply and Installation of
Straight Glass Partition Material: - (12 mm thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification." "Supply and Installation of
Straight Glass Partition Material: - (12 mm thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification."
Service Item 50: Unit basic rate in words ________________________________
SITC of Modular Glass Partition (SQUARE METERS)
"SITC of Modular Glass Partition
1) The minimum 5mm thick toughened glass tiles/panels shall be installed in
the modular paneling/partition system above 300mm high acoustical metal
tiles/panels. The modular glass partition system shall be Greenguard Gold
certified from UL/ Intertek. The necessary certificate/test report shall be
valid on the bid date.
2) These panels/tiles shall be properly integrated within the overall
panelling/partition system and shall remain aligned with adjoining
panels/tiles made of other materials, ensuring that all joints are uniform.
" "Supply and Installation of Straight Glass Partition Material: - (12 mm
thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
Page 14 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
RFQ Number :6001929441 Date : 15.04.2026
To:M/s. BPCL ESTIMATE MUMBAI - 400038 India (300648)
Item Material Qty Unit Unit Basic Rate
Description Delivery date (in Figures)
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification." "Supply and Installation of
Straight Glass Partition Material: - (12 mm thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification." "Supply and Installation of
Straight Glass Partition Material: - (12 mm thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification." "Supply and Installation of
Straight Glass Partition Material: - (12 mm thick toughened glass)
made of clear toughened glass, structural support system for top and bottom
including holding system from RCC slab above false ceiling, including runner
hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom
into SS ""U"" channel in floor. silicon sealant to filled gap. For details
please refer the technical specification."
Service Item 60: Unit basic rate in words ________________________________
Tempered Clear Glass Door2000mm X 2400m (Number)
"SITC of 12mm Thick Frameless Tempered Clear Glass Door
Size (±50mm) :- 2000mm X 2400mm
With door spring and locking arrangements and both way handle and patch
Specifications : Tempered glass is formed by heating glass to the softening
point in a horizontal tempering stove, and then quickly cooling it.
1) Safety (tempered): when broken, it spits into tiny harmless pieces
2) Strong intensity: heat-strengthened glass is approximately twice as strong
as annealed glass of the same thickness, and tempered glass is about 4 times
3) Outstanding performance in resisting thermal stress and wind-load
4) Tempered glass cannot be cut, drill hole and other further processed."
Page 15 of 26 Vendor Sign & Stamp For Bharat Petroleum Corporation Ltd.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
25069.pdf
pdf • 4.30 MB
BUDGETDOC_25069.pdf
pdf • 0.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .