| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.8 LAccepted-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹56.0 L+₹5.1 L (10.1%)Rejected-Finance | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹58 L+₹7.2 L (14.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1. | |
| 4 | L4₹58.7 L+₹7.9 L (15.5%)Rejected-Finance | L4 | Rejected-Finance Other than L1. | |
| 5 | L5₹58.9 L+₹8.0 L (15.8%)Rejected-Finance | L5 | Rejected-Finance Other than L1. |
Tender Value
₹79.4 L
EMD Value
₹1.4 L
Closing Date
11 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engr
HQ 134 Wks Engrs PIN-914134 c/o 56 APO
PROVN OF 1000 KVA HT AVR AT SHARIFABAD MIL STN UNDER AGE (I) CIF (K)
2022_MES_569276_1
134 WE-79(T)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Srinagar
9 documents required · 9 mandatory
₹1,000
AGE (I) CIF (K)
₹1.4 L
Yes
16 Mar 2023
15 Dec 2022
13 Jan 2023
15 Dec 2022
11 Jan 2023
5 Jan 2023
15 Dec 2022 - 29 Dec 2022
Amount
Supply, installation, testing and commissioning of HT Automatic voltage regulator 1000 KVA with input voltage 7 KV to 12 KV and output voltage 11 KV with 1% variation 3 phase, 50 Hz, AC supply oil cooled copper wound complete including all incoming and outgoing cable connection, complete all as specified and as directed. Note: Work to be executed as per manual and specifications of complany. The unit consits of the following :- (a) Step down transformer double wound, star/Delta connected. (b) On load stepless rolling contact type regular, auto wound delta connected. (c) Booster transformer double wound open. (d) Authomatic control gear consists of :- (i) One electric relay. (ii) One reversing geared motor unit (iii) Two limit switches in order to avoid over running highest and lowest position, chain drive, coupling devices and all electrical connection.
Transformer parts item (a) & (c) above shall be housed in a sheet steel tank fitted with radiators and mounted on unidirectional rollers and shall have the following fittings : (i) Lifting lugs. (ii) Earthing terminals. (iii) Rating plate. (iv) Filter value top & bottom. (v) Oil fitting hole. (vi) Thermometer packet. (vii) Silicagel dehydrating breather. (viii) Oil level gauge. (ix) Conservator. (x) Dial type oil temperature indicator with alarm and contacts. (xi) Explosion vent. (xii) Bochholz relay with alarm and trip contacts. (xiii) Air release plug.
MOTOR CONTROL : Raise/Lower switches shall be provided to restrict the travel at extreme positions. With this arrangement it wound also be possible to provide remove control of the regulating unit. The reversible geared motor wound of STEP-SYN type. AUTOMATIC CONTROL : For automatic corrections of fluctuating supply voltage we shall provide electronic relay which will sense the outtput voltage and provide signal to the driving motor for necessary corrections.Maximum termeratures rise (i) of oil by thermometer :50 Deg C (ii) of winding by resistance :55 Deg C (iii) of hot spot termperature indictor : 65 Deg C (iv) Limit of hot spot temperature indictor : 65 Deg C (iv) Limit of hot spot temperature : 110 Deg C. Note :- Above rates are including 230 V Aux supply by 0.5 KVA UPS. Unit (ii) & (v) under ser item No 1.10 here-in-before shall be housed in a separate tank and shall have the followings fittings :- (i) Uni-directional plain roller :04 Nos. (ii) Lifting lugs : 04 Nos. (iii) Earthing terminals : 02 Nos. (iv) Rating plate : 01 No. (v) Drain valve cum bottom filter valve with plug : 01 No. (vi) Oil filling hole : 01 No. (vii) Thermometer pocket : As per requirement. (viii) Plain oil level gauge : 01 No. (ix) Dehydrating silica Gel breather. (x) Inspection cover : As per requirement. (xi) Radiatores : As per requiremet.
Unit (iv) under item ser No 1.10 here-in-before shall be reversing Q air cooled panel :- (i) 630 AMP contractors : 04 Nos. (ii) Flip flop circuit : 01 No. (iii) Control card : 01 No. (iv) Push button switch : As per requirement.
Supply and installation, testing and commissioning of HT 11 KV 3 PHASE, 50 Hz totally enclosed metal clad switchgear complete with vacuum circuit breaker having rupturing capacity 350 MVA of rating upto 360 AMP, 11 KV indoor type, 350 MVA, 630 A, VCB horizonal drawout horizontal isolation floor mounting motorized panel with 230 V motor mechanism and 24 V DC shunt/close coil with CT, PT and IDMT relay and other fittings and accessories, Complete all as specified and as directed. 1. As incommer with CT/PT. 2. As outgoing with CT/PT. The following items are as under :- (a) Auxiliary relay model No-AVA 23. (b) B window annunciator model No -SI-801 (c) Master trip relay model No -AVAJH-13 (d) Trip circuit supervision relay model No JRV911 (e) Bus bar copper (f) Multifunction meter model No EM600 conzerv make (g) Audia alarm (Hooter/Buzzer) with alarm accept/reset relay (h) Batttery power pack with battery in built charger for 24 Volt circuit. FOR INCOMER PANEL:- (a) 11 KV 350 MVA horizontal drawout type vaccum circuit breaker compriding of (i) Vaccum interupt (ii) Motor/manal spring charging mechanizm-230 Volt AC (iii) Closing & tripping coil suitable for 24 Volt DC (iv) 4 ND + 4 NC auxiliary switch (v) Mechanicla on/off indication (vi) Mechanical spring charge/discharge indication (vii) Breaker position indicator (viii)Mechanical operating counter (ix) Authomatic safety shutters (x) Secondary plug in contacts. (xi) Anti pumping relay.
Supply, laying, jointing and testing XLPE insulated screened, PVC beded, galvanised steel strip or wire armoured electri powder cable heavy duty HT with aluminium conductor of size 240 Sqmm 3.0 Core in trenches on pole through pipes, fixed to walls etc, complete all as specified and as directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm, complete all as specified and as directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable 240 Sqmm, complete all as specified and as directed.
Supply, laying, testing and commissioning of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade (Earthed) cross sectional area 120 Sqmm, 3 core complete all as specified and as directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and as directed.
Earthing complete with GI earth plate 60cmx60cmx6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of earth plate not less then 1.5 metre below normal ground level, conneceted to galvanized iron earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3, connected to earthing test point all as specified or indicated including earth work in any type of soil, charcoal salt, 20mm bore GI light grade watering pipe, wire mesh, funnel, PCC pit in 1:2:4 type B1 and 40mm thick cover of RCC (1:2:4) type B-0 reinforced with XPM of weight not less than 4 Kg/Sqm and with 6mm dia MS bar handle made to shape, 40 mm bore GI protection pipe light grade upto 7.5 mtr length, complete all as specified, directed.
Supply and installation outdoor type gang operated Air break switch unit tripal pole, mechanically operated mounted on 12 Nos insulator and steel frame with operating mechanism suitable for working from ground level with GI pipe medium grade 25mm dia for current rating upto 200 Amps and droup out fuse assembly fixed on insulator suitable for HT 11 KV out door type 200 Amp (including suitable DO fuse), complete all as specified and as directed.
S&F Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11 KV, complete all as specified and as directed.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 mtr in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 Sq m on plan and not exc 1.5 m in depth and getting out in hard/dense soil, complete all as specified and as directed.
Returning, filling in excavation earth work including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exc. 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed.
M&L for dry river sand, laid in trenches for cable protection, as 8cm thick below the cable and 15cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured & paid.
M&L for sub class 'B' brick covering protection to the eletric cable, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of brick, complete all as specified and directed.
S&F 80mm bore GI tubing, light grade, laid in trenches, road crossing for cable protection or fixed to walls with clamps, complete all as specified and directed.
All as per Ser item No 16.00 here-in-before, but 100mm bore pipe.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .