Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L1 | Accepted-AOC RATES WERE REASONABLE | |
| 2 | L2₹19.4 L+₹66,944 (3.57%)Rejected-Finance NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹19.8 L+₹1.0 L (5.40%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Approved due to not having eligible category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Approved due to not having eligible category |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
21 Jun 2021, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
REPAIR/ MAINT OF HT INSTALLATIONS, HT VCBs, HT CABLES AND DISTRIBUTION TRANSFORMERS UNDER AGE(I) DARJEELING
2021_MES_445810_1
CWE/136-WE/09 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
DARJEELING
Class E, Category b(ii)
8 documents required · 8 mandatory
₹500
AGE (I) DARJEELING
₹38,000
Yes
26 Jul 2021
25 May 2021
22 Jun 2021
25 May 2021
21 Jun 2021
8 Jun 2021
25 May 2021 - 2 Jun 2021
Amount
Excavation in trenches exceeding 1.5 metre wide and exceeding 1.5 metre deep for laying cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated material from site to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre from the starting point complete all as specified.
M&L for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand complete all as specified and as directed
Supply and laying un-reinforced precast concrete cable cover, class HVP, type-1 flat size (300x180x40) mm for cable protection including taking out old damaged cover complete all as specified and as directed.
Laying only GI pipe 80mm dia medium grade / light grade for cable protection laid in trenches/structures/walls including necessary MC clamps, bolts, nuts, fastners etc including taking out the rusted pipes from the trenches complete all as specified and as directed. Note: GI pipe will be issue under Sch 'B'.
Dismantling of old ACSR conductor from the disturbed span including line spacer and unserviceable material and depositing to MES store yard for further use all as specified and as directed.
Dismantling of old earth wire or copper conductor, service feeder or distributor span etc and removing unserviceable material from site of work complete all as specified and as directed.
Dismantling of old unserviceable/defective (Pin type, Shackle type etc) insulators of any size/type and removing materials from site of work complete all as specified and as directed.
Dismantling and taking down mild steel cross arms, MS channels, angles, clamps from pole structure and depositing to MES store yard for further use all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 11000 volts grade with stranded aluminium conductor conforming to IS: 7098 (Part-II) of size 95 sqmm 3 core complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 11000 volts grade with stranded aluminium conductor conforming to IS: 7098 (Part-II) of size 70 sqmm 3 core complete all as specified and as directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing materials and accessories suitable for 3 Core HT XLPE armoured aluminium conductor cable for size 50/70/95 Sqmm after cutting out the faulty joint complete all as specified and as directed.
M&L for insulator Pin type, grey polymer insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified.
M & L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed.
M & L plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation of poles, stays assembly, mass concrete etc. including necessary formwork complete all as specified and as directed.
Supply, install, testing and commissioning switch air break, mechanically gang operated, mounted on 12 nos insulators and steel frame with operating mechanism worked from ground level with drop out fuse (set of three) for current rating up to 400A for working pressure 11000 volts including taking out old one complete all as specified and as directed.
Servicing / calibration / trouble shooting / repairing / adjustment of over current relay, earth fault relay, Spring, spring charge mechanism, close coil, trip coil, including connected accessories cleaning of all contacts with CTC, of the 11KV HT VCB panel of 630A, 50 Hz by qualified technical personnel to make functional in all respects including identifying the defective parts complete all as specified and as directed.
Supply only following spares in repairs suitable for 11KV HT VCB of maximum short circuit current rating 25/26.3 KA 630A/400A after taking down the old spares complete all as specified and as directed.- (Note : Srl No. 19.00 is here by continued as Srl No. 19.01 to 19.13)
a) LED indicating lamps R/Y/B
b) LED indicating lamps amber
c) LED indicating lamps white
d) Trip circuit push button with NO contracts.
e) Limit switch
f) Tripping shaft assembly
g) Closing shaft assembly
h) Space heater
j) Thermostat
k) HRC control fuse 2A, 4A, 6A 10A
l) Fuse Holder with base
m) Breaker control Switch
n) Single phase power pack with capacitor backup, 110V DC
M & L for disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green two-in-series assembly for tension with tension clamps for conductors, working pressure 11000 volts all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 32 x 6 mm as earthing lead (up to 7.5 m in length from earth plate ) by means of bolts and nuts check nuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion.
Disconnecting and removing transformer from mounting platform after disconnecting HT/LT side cable connections and transporting of unserviceable transformer for rewinding from MES sub station to contractors/civil workshop and vice versa by arrangement of necessary crane for taking down loading / unloading and refixing at site all as specified and as directed of following capacity :- (Note : Srl No. 22.00 is here by continued as Srl No. 22.01 to 22.02)
(a) 50 KVA to 100 KVA
(b) 150 KVA to 200 KVA
Rewinding of transformer of under mentioned capacities by super enamelled copper wire as per existing gauge of primary coil with `E’ class insulation, varnishing and heating the coil properly, fixing on core and making connection to achieve rated voltage and current all as specified and directed. (Note : Srl No. 23.00 is here by continued as Srl No. 23.01 to 23.02)
Rewinding of transformer of under mentioned capacities by super enamelled copper wire as per existing gauge of secondary coil with `E’ class insulation, varnishing and heating the coil properly, fixing on core and making connection to achieve rated voltage and current all as specified and directed by Engr-in-Charge:- (Note : Srl No. 24.00 is here by continued as Srl No. 24.01 to 24.02)
Supply only brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer all as specified and directed of following capacity :- (Note : Srl No. 25.00 is here by continued as Srl No. 25.01 to 25.03)
(a) 63 KVA to 100 KVA
(b) 150 KVA to 250 KVA
(c) 300 KVA to 400 KVA
Supply only brass spindle for terminal on LT side threaded complete with nut, washers etc of suitable dia for transformer all as specified and directed of following capacity :- (Note : Srl No. 26.00 is here by continued as Srl No. 26.01 to 26.03)
(a) 50 KVA to 100KVA
(b) 150 KVA to 250 KVA
(c) 300 KVA to 400 KVA
Supply only ceramic bushing on LT side of transformer all as specified and directed of following capacity:- (Note : Srl No. 27.00 is here by continued as Srl No. 27.01 to 27.03) Make : Mysore potteries/BHEL/ Bikaner ceramic's.
Supply only ceramic bushing on HT side of transformer all as specified and directed of following capacity:- (Note : Srl No. 28.00 is here by continued as Srl No. 28.01 to 28.03) Make : Mysore potteries/BHEL/ Bikaner ceramic's.
Dehydration/filtration of transformer oil by means of centrifugal filtration plant to achieve the specified dielectric strength of 35 to 40 KV at 2 mm gap in existing possession of transformer of any capacity and transformer oil for topping up at various sub-station all as specified and directed.
M&L for aggregate for loose filling, with broken stone or boulders of gauge 40 to 80mm graded including stacking of materials in regular heaps/ stacks for measurement complete all as specified and as directed
Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Note 3:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
Janata Enterprises
GEETA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .