| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC | L1 | Accepted-AOC Preferene given to society over the contractor on the same rates offered by the Contractor. | |
| 2 | L1₹4.2 LRejected-Finance | L1 | Rejected-Finance Preference given to Society as per Govt. Rules. | |
| 3 | L2₹4.4 L+₹18,882 (4.50%)Rejected-Finance INDER NAGER NEW KHNEELLI ROAD NEAR IDTER OFFICE ROHTAK INDER NAGAR NEW KHANELLI ROAD ROHTAK 124001 | ROHTAK | HARYANA | 124001 | L2 | Rejected-Finance Higher rate Bidder | |
| 4 | L3₹4.5 L+₹27,665 (6.59%)Rejected-Finance | L3 | Rejected-Finance Higher rate Bidder |
Tender Value
₹4.5 L
EMD Value
₹8,940
Closing Date
15 Nov 2021, 5:00 pmClosed
Executive Engineer
Rohtak W/S DIvision ROhtak
Constructing toilet and laying interlocking paver blocks at Moi Head at RD 83000 of Bhalaut Sub Branch.
2021_HRY_194554_1
11958-81/5AC dt. 02/11/2021
Open Tender
Civil Works
Item-rate/Agreement basic
90 days
ROHTAK
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹8,940
Yes
2 Dec 2021
2 Nov 2021
16 Nov 2021
2 Nov 2021
15 Nov 2021
2 Nov 2021
Amount
E/Work excavation in foundation and plinth in all kinds of soil upto 3 mtr depth HSR 15.1.2.1
Laying CC 1:3:6 with stone aggregate 20 mm nominal size in F & P as per H.S.R 6.1.4
First class brick masonary laid in Cement sand Mortar 1:4 in F&P as per H.S.R 15.6.3
DPC 80 mm thick (2 layers of 40 mm) of cement concrete 1:2:4 using stone aggregate as per H.S.R 6.8.2
First class brick masonary in CM 1:4 in superstructure as per H.S.R 7.22.1
Laying R.C.C 1:1.5:3 for beams, lintels, slabs etc as per H.S.R 6.15.1
Tile Terracing as per HSR 9.14.1
Cement concrete (1:2:4) Gola 75 mm x 75 mm junction of roof with parapet wall finished smooth HSR 9.17.1
TMT bars Fe-500-D for steel reinforcement I/C bending binding & placing in position complete as per HSR 6.34.6
12mm thick cement plaster 1:4 over walls of toilet room HSR 11.5.3
Centering & shuttering for flat surface of roof HSR 6.30.3
Centering & shuttering for side & soffits of beam HSR 6.30.5
Earthwork in filling under floor with lead upto 60 mtr HSR 15.1.1.1
Cement concrete 40 mm cement concrete 1:8:16 HSR 10.100.2
Providing & Fixing Vitrified tiles 600 mm x 600 mm of approved make in flooring laid in any pattern as specified over base 20 mm thick bed of cement coarse sand mortar 1:3 & jointed with white cement slurry mixed with pigment to match shade to tiles as per HSR 10.67.2
Providing & fixing 1st Quality Ceramic Glazed Wall Tile confirming to IS 15622 (Thickness to be specfied by the manufacturer) of approved make in all colors, shades except burgundy, bottle green, black of any size as approved by EIC in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed with pigment of maching shade complete. Size of Ceremic Glazed tiles 300 mm x 450 mm as per HSR 10.62
Providing top khurra (0.60 mtr x 0.60 mtr) for rain water pipe as per HSR 9.18
Providing and fixing of iron chowkhat consisting of L iron 40mm x 40mm x 5mm for door and ventilator I/C hole pass and hinges etc. complete as per HSR 13.2
Providing and fixing of iron door & window shutters complete as per HSR 13.6.1
Painting two coat of new work ready mixed paint (First quality paint) as per HSR 11.73.1
Lavatory suites providing and fixing in position best indian make (ordinary) white color 630 mm x 450 mm size with one tap as per HSR 22.1.1
Urinal providing and fixing in position best Indian make flat back or angular lipped front urinal 465 mm high consisting of standard size GI flush pipe with CP brass wall clips and unions complete including cutting and making good the walls and floor and painting of fittings etc as required as per HSR 22.47
Water Closet Suites, providing & fixing in position best Indian make, Indian type water closet suite complete in all respects i/c cutting and making good the walls and floors and painting of fittings etc. of size 630 mm white in color as required as per HSR 22.22.1
Water Closet Suites, providing & fixing in position best Indian make, European type water closet suite syphonic type complete in all respects i/c cutting and making good the walls and floors. Single trap syphonic WC suite white in color as required as per HSR 22.23.1
Providing and fixing HDPE Water Storage Tank of Sintex, Diplast, OK Supreme make with building i/c cost of hoisting and placing in position making connections with inlet and outlet pipes providing overflow and scour provisions with suitable plug on scour pipe i/c cost of nipples washers and flanges for connection in tank complete in all respect. 500 Ltr. capacity as per HSR 22.181
Laying and fixing GI Pipe B Class 20 mm dia HSR 22.88.2
Laying and fixing GI Pipe B Class 15 mm dia HSR 22.88.1
Providing and fixing in position 15 mm dia C.P. brass bib cocks as per HSR 22.104.1
Providing and fixing in position 15 mm dia C.P. brass stop cocks HSR 22.107.1
Providing and fixing in position PVC waste pipe (N.S. Item)
Providing and fixing in position best Indian Make bevelled edge 5.5 mm thick mirror mounted on asbestos sheet ground fixed in position by means of 4 Nos. chromium plated brass screws and washers complete in all respect i/c cutting and making good the walls etc. HSR 22.209
Providing and fixing PVC bend ISI mark 100 mm dia as per HSR 9.58.5.2
Wiring in 1.5 sqmm PVC insulated copper conductor cable in 1.6 mm thick conduit pipe. 3-Pin 5-Amp Plug point i/c earthing the 3rd pin etc. (Medium Point) as per HSR 23.3.4.1
Wiring in 1.5 sqmm PVC insulated copper conductor cable in 1.6 mm thick conduit pipe. 3-Pin 5-Amp Plug point i/c earthing the 3rd pin etc. (Short Point) as per HSR 23.3.4.1
Wiring in 1.5 sqmm PVC insulated copper conductor cable in 1.6 mm thick conduit pipe. 3-Pin 15-Amp Plug point with 4 sqmm PVC insulated copper conductor cable i/c earthing the 3rd pin etc. (Medium Point) as per HSR 23.3.5.1
MCB (Miniature Circuit Breaker) and isolator Supply & Erection of MCB of 9 KA breaking capacity 6 Amp to 32 Amp including making necessary connections as per HSR 23.22.5.1
MCB (Miniature Circuit Breaker) and isolator Supply & Erection of Isolators 40 Amp including making necessary connections as per HSR 23.22.5.2
Supply & Erection of pipe for wiring purposes i/c bends, inspection boxes, etc where necessary Heavy gauge welded conduit pipe 20 mm dia 1.6 mm thickness flushed HSR 23.7.6.1
S&E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size. Cable size 1.5 sqmm as per HSR 23.3.6.1
S&E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size. Cable size 4 sqmm as per HSR 23.3.6.3
White washing 3 coats on new plaster surface HSR 11.61.1
Providing & embedding PVC 100 mm dia rain water pipe in cement mortar during masonary work HSR unique code B0241
Applying priming coat with metal primer on new steel or iron work i/c preparation of surface as per HSR 11.68.3
Supply of G.I pipe 15 mm ISI mark HSR 23.23.1.1
Supply of G.I pipe 20 mm ISI mark HSR 23.23.1.2
Hand Pumps (Pulling out pipe and filters) as per HSR 18.52.1
Hand Pumps (Lowering of pipe in the hole upto 40 mm dia) as per HSR 18.52.2
Hand Pumps (Fixing head including clamps and handle) as per HSR 18.52.3
Boring for Hand Pump as per HSR 18.51.1.3
Providing & laying 100 mm thick ISI marked Interlocking Paver Blocks over the bed of 30 mm thick fine sand complete in all respect as per HSR 17.69.1
The Shiv Co-op Multipurpose Society Ltd
The Baba Haridass Co-op Labor and Construction Society Ltd.
JAGSHANTI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .