| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹7.7 L+₹2.0 L (35.3%)Rejected-Finance GF AKRITI TOWER 19 B VIDHAN SABHA MARG LUCKNOW PIN 226001 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹15.8 L+₹10.0 L (175.2%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
16 Jun 2020, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
COMPREHENSIVE MAINTENANCE OF FIRE FIGHTING SYSTEM AT M 53 OF 4 BRD TTCLRE HANGER AND BEARING HOSPITAL IN TECH AREA AT AFS CHAKERI KANPUR
2020_MES_338182_2
8356/E8
Open Tender
Civil Works
Item Rate
334 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹18,000
14 Jul 2020
27 May 2020
20 Jun 2020
27 May 2020
16 Jun 2020
2 Jun 2020
Amount
Comprehensive monthly maintenance of auto fire alarm system installed in Bearing Hospital in Tech Area at AF Stn Chakeri complete all as specified and directed. . The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational of all the equipment of fire detection system should be maintained. (iii) The contractor will submit daily inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. Note:- 1. The detail of fire detection & fire fighting system are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (200 device/loop card) - 01 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 73 Nos. (c) UL Listed intelligent heat detector - 02 Nos. (d) Manual call point - 08 Nos. (e) Control module for hooter - 14 Nos. (f) zone Monitor module - 14 Nos. (g) Fault isolator - 08 Nos. (h) Wall mounted hooter - 14 Nos. (j) Response indicator - 12 Nos. (k) IR Flame detector - 14 Nos. (l) UPS 500 VA - 01 No. 2. Testing of the entirefire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
Comprehensive monthly maintenance of auto fire alarm detection and fire fighting system installed in M-53 OF 4BRD in Tech Area at AF Stn Chakeri complete all as specified and directed. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational of all the equipment of fire detection system should be maintained. (iii) The contractor will submit daily inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. Note:- 1. The detail of firedetection & fire fighting system are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (200 device/loop card) - 01 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 4 Nos. (c) UL Listed intelligent heat detector - 02 Nos. (d) Auto dialer - 01 Nos. (e) External siren - 01 Nos. (f) Nitrogen gas cyclinder - 05 Nos. (g) Carbon di oxide cyclinder - 15 Nos. (h) Manual call point - 08 Nos. (i) Control module for hooter - 4 Nos. (j) zone Monitor module - 4 Nos. (k) Fault isolator - 08 Nos. (l) Response indicator - 12 Nos. (m) IR Flame detector - 02 Nos. (n) UR Gas detector - 04 Nos. (o) Smoke detector - 02 Nos (p) UPS 500 VA - 01 No. 2. Detection system shall be tested monthly along fire fighting system. 3. Fire fighting system and complete system efficiency along with release of Carbon di oxide and Nitrogen shall be tested at least once in three month. 4. Weighing of Carbon di oxide and Nitrogen per month shall be done.
Comprehensive monthly maintenance of auto fire alarm system installed in TTCLRE Hanger in Tech areaat AF Stn Chakeri complete all as specified and directed. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational of all the equipment of fire detection system should be maintained. (iii) The contractor will submit daily inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire detection & fire fighting system are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (200 device/loop card) - 01 No. (b) UL Listed intelligent addressable multi-sensor detector with heat & smoke combination-492 Nos. (c) UL Listed intelligent heat detector -04 Nos (d) Manual call point - 82 Nos. (e) Audio visual indication of smoke or fire-20 Nos. (f) zone Monitor module (g) Fault isolator - 30 Nos (h) Wall mounted hooter (j) Response indicator -100 Nos (k) IR Flame detector (l) UPS 500 VA 2. Testing of the entirefire detection and alarm system shall be carried out and report shall be submit regardinding functioning of the system complete all as specified and directed by Engr-in-charge.
Supply & Fix in repair intelligent Analogue addressable multicriteria type heat with smoke detector with base complete all as specified and directed. Make : MOORLEY/APOLLO/Siemens/Honeywell.
Supply & Fix in repair intelligent Analogue addressable type manual call point with box resettable type complete all as specified and directed. Make :MOORLEY/APOLLO / Siemens/Honeywell.
Supply & Fix in repair Electronic hooter cum strove to provide audio visual indication of smoke or fire with public address system compatibility complete all as specified and directed. Make : MOORLEY/APOLLO/Siemens /Honeywell.
Supply & Fix in repair remote response indicator complete all as specified and directed. Make : MOORLEY/APOLLO/Siemens /Honeywell.
Supply & Fix in repair Fault isolator to prevent short circuit/open circuit complete all as specified and directed. Make : MOORLEY/APOLLO/Siemens /Honeywell.
Supply & Fix in repair PVC insulated, sheathed electric cable FRLS 1100V grade two core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in non metallic rigid PVC concealed conduit complete all as specified and directed.
Supply & Fix in repair PVC insulated FRLS type . sheathed armoured copper conductor cable of size 1.5 Sqmm 2 core complete all as specified and directed.
Supply & fix in repair sluice valves class PN-1.6 , IS-14846 ISI marked with CML No with flanged ends, with stainless steel spindle duly drilled including nut bolts and rubber packing complete as reqd at site of sizes 150 mm complete all as specified and directed.
Supply and fix Cotton synthetic fiber circular woven jacket rubberized fiber reinforced rubber line (RRL) hose 63 mm dia 30 m long ( bursting pressure 35.7 Kg/ Cm Sq) with gun matel female coupling confirming to IS 636 and 903 complete all as specified and directed. Make - New Age/ Omex.
Supply & fix in repair for Nozzle 63 mm dia short bench pipe confirming to IS :2871:1983 made of cast copper alloy complete all as specified and directed. Make - New Age/ Omex.
Supply, fix and commissioning of single outlet type fire hydrant confirming to IS 5290, consisting of 63 mm dia landing valve fitted with instaneous spring locked type Gun matel female coupling duly painted red complete all as specified and directed. Make - New Age/ Omex.
Toping up/Refill and testing Dry chemical powder fire extinguisher ABC ,5 kg capacity ISI marked IS: 15683 with operating temp (+5)oC to (+55) 0C for class 4 A type of fire filled wity MAP ABC Powder complete all as specified and directed. Make: Ceasefire /Omex/Minimax
Toping up/Refill and testing CO2 type fire extinguisher 4.5 kg capacity with squeeze grip valve operating temp (-30)o to (55) 0C for class 13 B type ISI marked confirming to IS 15683 with PVC bend horn complete all as specified and directed. Make: Cease Fire /Omex/Minimax
Supply and install Mechenical Foam (AFFF) type fire extinguisher 9 ltr capacity with ISI marked confirming to IS 15683 etc complete all as specified and directed. Make: Cease Fire /Omex/Minimax
M & L for repair of loop microprocessor based fully analog addressable type fire alarm repeater panel complying with BSEN 54 single loop panel of capacity upto 200 detector and module (per each loop) including replacement of faulty part complete all as specified and directed. Make: Honeywell/APOLLO/Siemens/Moorley
M & L for repair of Intransically safe Conventional photoelectric smoke Detector UL/FM/LPC approved with junction box and base complete to be fixed inside test rig with suitable fixing arrangement complete all as specified and directed. Make:Apollo model Orbis cat part No ORB-OP-52027-APO/ Systen senser cat part No JTY-GD-2151 EIS or equivalent make in Hochiki / BOSCH.
M & L for repair of Intransically safe Conventional heat detector class AIR, UL / FM / LPC approved with base complete all as specified and directed. Make: Apollo Model Orbis cat part No ORB-HT-51145-APO / Systen senser cat part No JTWB-BCD-5151EIS or equivalent make in Hochiki / BOSCH
Supply and fix in repair External Siren 2 KM range with control panel complete all as specified and directed. Make: Kheraj / KPT / National / System senser
Supply and fix in repair Nitrogen gas cylinder 4 Kg Pilot with nitrogen gas ISI marked complete all as specified and directed. Make: EKC / RAMA / CCOE.
Supply & fix in repair of pneumatic actuator made of brass on CO2 cylinder ISI marked IS 3224, complete all as specified and directed . Make: Rotex / Newage / KEW
Supply & fix in repair of electric solenoid operated actuator made of gunmetal all as per IS 8935 for operating the value of nitrogen cylinder complete all as specified and directed. Make: Rotex / Newage / KEW
Supply & fix in repair of wire braded high pressure discharge hose 3/8" WP 3024 PSI /210 BAR on CO2 cylinder complete all as specified and directed. Make: DOZZ / Rownak / New Age / Markwell / Super Hose.
Supply and filling CO2 gas in fire extinguisher of different capacity including Transportation for refilling from site to workshop on to & fro basis complete all as specified and directed.
M & L for fabrication of mild steel flats iron clamp,angle iron , nut bolt and washer etc for supporting to CO2 gas pipe line including painting with one coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Supply & fix in repair of intrinsically safe and weather proof manual call point with push button fired bride box sealed with glass including necessary electrical connection complete all as specified and directed. Make: Agani / NSD / Agani Alarm / System sensor
Supply & fix in repair of low intensity hooter for warning of fire connected with central contol panel installed in each zone inside the rooms complete all as specified and directed. Make: Agani / NSD / Agani Alarm / System sensor
Supply and fix in repair Gun metal NRV 25 mm dia and fixing of NRV with MS pipe including cutting and welding work complete all as specified and directed.
Supply and fix of horn type stainless steel nozzle inner dia 15 mm , outer dia 20 mm and 65 mm long incuding fittings complete all as specified and directed.
Supply & fix in repair of lead acid battery of 12 Volt, 150 AH complete all as specified and directed. Make: EXIDE (Chloride) / OKAYA / AMRON
Supply & fix in repair/ replacement of lead acid battery of 12 Volt, 7 AH complete all as specified and directed. Make: EXIDE (Chloride) / OKAYA / AMRON
Supply and fix in repair Single stage regulator(Two GAUGE) NITROGEN Regulator complete with necessary connecting brass parts complete all as specified and directed. Make: ESAB india limited model INI 42B
Supply & fix in repair of CO2 discharge indicator including fitting & accessories complete all as specified and directed. Make: Agani / NSD / Agani Alarm
Supply & fix in repair of CO2 release unit for manually operated with push button fired bride MS box duly painted sealed with glass including necessary electrical connection complete all as specified and directed. Make: Agani / NSD / Agani Alarm / System sensor
S &F in repair of 63 mm dia RRL hose pipe 15 Mtr long with male & female SS couplings bend riveted to hose pipe ISI marked & confirming to relevent IS complete all as specified and directed. Make: GTech /Newage or eqvivalent
M&L in repair for MS ERW pipe heavy duty 65 mm dia connected with existing pipe with welding work complete all as specified and directed. Make: Zindal / Tata / Prakash surya
M&L in repair for MS ERW pipe heavy duty 40 mm dia connected with existing pipe with welding work complete all as specified and directed. Make: Zindal / Tata / Prakash surya
M&L in repair for MS ERW pipe heavy duty 25 mm dia both connected with existing pipe ewith welding work complete all as specified and directed. Make: Zindal / Tata / Prakash surya
M&L for power supply high current power supply that provides fire finder-XLS system with primary regulated 24 VDC, it should be rated at 12 A and built in charger & should be capable of charging up to 100ah battries, should have microprocessor controlled transfer circuit, PSC-12 of Siemens complete all as specified and directed.
M&L for Programming Unit for programming and testing of Detector and devices of fire finders-XLS and wiring loops for ground faults and shorts circuits,communication of installed devices and addresses of all devices of Siemens complete all as specified and directed.
Supply and fix in repair of PCB loop cord suitable for self addressable fire finder system complete all as specified and directed. Make: Siemens/Honeywell
Prime Technology
shanti enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .