Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹26.4 L+₹2.9 L (12.6%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest bid | |
| 3 | L3₹27.2 L+₹3.8 L (16.0%)Rejected-Finance JAIN SADAN MAHAL ROAD SHIVPURI DISTT SHIVPURI MP | SHIVPURI | SHIVPURI | MADHYA PRADESH | L3 | Rejected-Finance Being other than lowest bid | |
| 4 | L4₹27.2 L+₹3.8 L (16.4%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest bid | |
| 5 | L5₹27.6 L+₹4.2 L (18.0%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest bid |
Tender Value
₹31.9 L
EMD Value
₹63,860
Closing Date
16 Dec 2024, 6:00 pmClosed
GE (North) Udhampur
GE (North) Udhampur PIN - 901 220 C/O 56 APO
PROVN OF AREA DRAINAGE AND ADDN / ALTN TO EXISTING DRAIN IN MD / OTM ACCN AND ADDN / ALTN IN CONF HALL AT HQ 71 SUB AREA UNDER GE (NORTH) UDHAMPUR
2024_MES_684333_1
GE/U(N)-65/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE North Udhampur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE North Udhampur
₹63,860
Yes
28 Jan 2025
18 Nov 2024
24 Dec 2024
19 Nov 2024
16 Dec 2024
3 Dec 2024
Amount
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type soil, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and depth exc 1.5 mtr but not exceeding 3.0 for foundation, shaft, wells, cesspits, manholes etc. and getting out in any type of soil, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and directed.
M&L for brick work with using sub class 'B' bricks, old size, straight or curved on plan exc 6 mtr mean radius, built in CM 1.4, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in seismic and other similar bands, string courses, lacing courses, parapets and railings upto 60cm in height, copings, pedastal and the like including weathering, slightly rounded or chamfered angles, throating and including necessary formwork, complete all as specified and directed.
M&L for 15mm (10+5 layers) thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces or RR masonry with using water proofing compound, finished the surface even and smooth without using extra cement, complete all as specified and directed. Note :- Cost of WPC shall be deemed to include in the quoted rates.
Taking down cement plaster on brick walls, stone masonry/ walls, concrete surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in surface channels and drains etc, complete all as specified and directed.
M&L for extra for forming fair finished drain of channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in cover slabs for manholes, culvert on drain and similar articles with plain faces with and including necessary formwork, set in cement mortar 1:4, complete all as specified and directed.
S&F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, side hung gates, gates (ornamental and intricate design) etc. including all necessary fittings, with ends of bars, shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, staging for water tanks and similar work, conforming to Fe-290, Gde-E-165, complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description, exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
Supply & Laying 450mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars, complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in bed to RCC drain pipes of 450mm bore including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed.
Dismantling wall and ceiling boards, fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets of any thickness including cover fillets or MS/ aluminium grid/ frame, complete all as specified and directed.
S&F false ceiling non asbestos fibre cement board of 4mm thick, panel size 600x600mm, designed (as approved by GE), conforing to IS:12862 to IS:14862 type 'B' in true horizontal level, suspended on interlocking metal grind dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main 'T' runner with suitably spaced joints to get required length, and 15x32mm made of 0.30mm sheet and cross at 600mm c/c to form grid including required cutting/ making, opening for services like diffusers, grills, light fittings, fixures, smoke detectors etc. Main 'T' runners to be suspended from ceiling using GI soffit cleats fixed existing rafter, purlin etc. with galvanised butterfly clips, spacd at 1200mm c/c along a min 'T', bottom exposed width of 15mm all T-sections shall be centra black prepainted with polyester paint and having a load bearing capacity of 12 Kg/Sqm and fixed all exesting electric wiring and fixture, complete all as specified and directed. Note :- The work shall be executed at any height as per site requirement and rates for the same shall be deemed to include in the quoted rates.
S&F in repair/ replacement wooden flooring, panel size 1215mm x 195mm and thickness 8.3mm, direct pressure laminated according to EN-13329 for glueless installation heavy domestic and light commercial use, EN-13329 level of use 22 including under layer of 2mm thick EP and polythene layer, complete all as specified and manufacturer's instructions and directed by Engineer-in-Charge.
S&F antique type curtain rods with double bracket system and onion type end backets, complete all as specified and directed. Note :- Design and pattern shall be approved by GE before incorporating in the work.
M&L for 18-20mm thick pre-polished (mirror type) granite stone work (protruding chamfered/ rounded edges in threads table rubbed and polished) as in steps, jambs, pillars, window cills, cooking plateforms and the like, bedded and jointed with grey cement slurry and pointing in white cement (1:2) with using marble dust and admixture of pigment to match with shade of granite, fixed/ laid over and including 15mm thick screed bed/ plaster in CM 1:4, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames), area not exceeding 1.50 Sqm each including cutting holes for taking out hold fasts or dismantling brick work or cut holes for taking out hold fasts and making good disturbed surface to match with existing surface, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames), area exc 1.50 Sqm but not exc 4.0 Sqm each including cutting holes for taking out hold fasts or dismantling brick work or cut holes for taking out hold fasts and making good disturbed surface to match with existing surface, complete all as specified and directed.
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprane gasket as required (fittings shall be paid seprately) with extruded built up standard tubular section/ appropriate 'Z' section and other section of approved make, conforming to IS:733 and IS:1285, fixing with dash fastner of required dia and size including necessary filling up the gaps at junctions i.e. top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanical wherever required including cleat angle, aluminium snack beeding for glazing/ paneling, CP brass/stainless steel screws, necessary fitting roller, handle, locking system etc, complete as per architectural drawing and as directed by Engineer-in-Charge.
S&F glazing with 5mm thick frosted/ tinted sheet glass, exc 0.50 Sqm in each panel, fixed to aluminium section of door, window and fixed frame with suitable EPDM rubber packing and power coated aluminium beading to frame, complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, sliding / openable windows, ventilators with one or more rebates including joining cleats for fixing etc, complete all as specified and direced.
S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with a minimum anodic coating of grade AC 15) of approved design/ pattern with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screws @ 200mm centre to centre and including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete as per site requirement and directed by Engineer-in-Charge.
S&F wall panelling of plastic vinyl composite panel of size 3050mm x 254mm x 8mm thick with wooden/ plane surface, waterproof, termite proof, chemical resistant of light weight, fixed with wooden screw with rawl wall plug, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) as in ground floor and paving area of any type and any thickness, complete all as specified and directed.
Dismantling floor, hearth or wall tiles including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for 40mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in leveling course, sub base or floors, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 10mm thick coloured vitrified ceramic tiles, light shade (square or rectangular), polished, size of each tile 600x600mm, laid as in floors over and including 15mm thick screed bed or bedding layer CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed.
M&L for 10mm thick coloured vitrified ceramic tiles, light shade (square or rectangular), polished, size of each tile 600x600mm, fixed as in skirtings over and including 10mm thick rendering CM 1:3, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed.
M&L for 10mm thick coloured vitrified ceramic tiles, double charged, rectangular of size 1200x600mm, polished, laid/ fixed as in floor, skirtings over and including 10mm thick screed bed or plaster in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed.
S&F tinted tougned and tempered glass panels including unframed assemblies (such as frameess doors), comprising of 15mm thick glass pressed by controlled thermal of chemical treatment to increase it's strength compared with normal glass, conforming to IS2553 Part-1, to be fitted as per manufacturer's instructions and directed by Engineer-in-Charge. Notes :- (a) No cutting and grinding of glass shall be allowed at site of work and the contractor shall procure actual size required at site in consultation with Engineer-in-Charge prior to placing the order for the same. (b) Rates are inclusive to all necessary fittings such as suitable, heavy duty, hydraulic floor spring, locking arrangement with cover plates top and bottom hinges with cover plates, stainless steel 300mm fancy type handle 02 Nos on each shutter and fixtures as stainless steel as required at site. (c) The work shall be got executed by the specialist agency as approval of GE. (d) Existing door opening shall be finished identical to existing one like finishes including holes cut and any other damage to jambs and lintel. (e) The glass shall have all kinds of pattern, design sticker as approved by GE/EIC.
S&F mortice lock with two lever MS body (vertical type), 100mm lenth of latch with 3 sets of key, fixed in door shutter with proper in position, complete all as specified and directed.
Taking down carefully existing copper / aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling roses, regulators, bell, fan regulators etc. by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good disturbed surface of walls, floors to match with existing surfaces, complete all as specified and directed.
Taking down fluorescent tube light, single/ double of any wattage and size, for repair or replacement of burnt/ worn out accessories or carrying to MES store for reuse or taking in credit, complete all as specified and directed.
Taking down old serviceable/ unserviceable MCB DB of any type & size after disconnecting (serviceable DBs / MCBs shall be reuse), complete all as specified and directed.
M&L for point wiring using approved color coading as per IS code (Red, Black and Green for single phase circuit) with multistranded copper condutor 1.5 Sqmm nominal cross section area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn through in and including medium grade PVC concealed conduit ISI marked of dia not less than 20mm dia and conduit accessories, concealed in wall/ roof/ floor etc. with terminated to new pressed flush metal box and readily available cover with outer plates and inner plates etc., suitable for mounting modular type switches, sockets, fan regulators etc. and PVC insulated multistranded copper condutor 1.5 Sqmm nominal cross section area 1.5 Sqmm, single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly, complete all as specified and directed for the followings :-
All as per serial item No. 40.00 here-in-above but for one light point controlled by one way switch.
All as per serial item No. 40.00 here-in-above but for one ceiling fan point, controlled by one way switch.
All as per serial item No. 40.00 here-in-above but for one exhaust fan point, controlled by one way switch.
All as per serial item No. 40.00 here-in-above but for one wall fan point, controlled by one way switch.
All as per serial item No. 40.00 here-in-above but for one modular socket outlet 3 pin, 5 Amps on same board with other switches.
All as per serial item No. 40.00 here-in-above but for one modular socket outlet 3 pin, 5 Amps on independent board.
M&L for point wiring using approved color coading as per IS code (Red, Black and Green for single phase circuit) with multistranded copper condutor 2.5 Sqmm nominal cross section area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn through in and including medium grade PVC concealed conduit ISI marked of dia not less than 20mm dia and conduit accessories, concealed in wall/ roof/ floor etc. with terminated to new pressed flush metal box and readily available cover with outer plates and inner plates etc., suitable for mounting modular sockets 2 in 1 5/16 Amps or power socket and PVC insulated multistranded copper condutor 2.5 Sqmm nominal cross section area 1.5 Sqmm, single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly, complete all as specified and directed.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 16-20 Amps, 240 Volts, complete all as specified and directed.
S&F in replacement modular switch, one module, one way, 5/6 Amps, single pole, complete all as specified and directed.
S&F in replacement modular socket outlet 5 Pin, 6 Amps, 2 module, 240 Volts, complete all as specified and directed.
S&F in replacement modular socket outlet 2/3 Pin, 6 & 16 Amps, 2-in-1, multipurpose, complete all as specified and directed.
S&F in replacement modular switch, one module, one way, 16 Amps, single pole, complete all as specified and directed.
S&F in replacement modular electronic fan regulator, step type, two module, 120 watt, 230 Volts, complete all as specified and directed.
S&F in replacement ceiling rose, surface bakelite type of size 65x50mm with three terminals, complete all as specified and directed.
S&F in replacement of ceiling mounting LED warm/ white light fitting, Vector Series, create beautiful pattern on ceiling, seamless integration with ceiling, easy maintenance, high system efficacy alonwith 3 CCT options and convert your ceiling into a beautiful piece of art, suitable for armstrong / grid / ceiling, complete all as specified and directed.
S&F in replacement 10 Watt pressure die cast aluminium bulk head light, weather proof, confirming IP-66, highly resistant to dust and water, suitable for outdoor installation, energy efficient, provides smooth light distribution and long-lasting, complete all as specified and directed.
M&L for repair/ replacement for submain wiring with copper conductor cable 4 runs of multi-stranded 10 Sqmm FRLS PVC, ISI marked with insulated unsheathed, drawn in and including PVC concealed conduit 25mm dia, medium grade ISI marked with all necessary conduit fittings, cutting chasing and 2x10 Sqmm copper conductor cable FRLS PVC insulated unsheathed multi-stranded using as continues earth wire connected to common earth and earth dolly, complete all as specified and directed.
M&L for repair/ replacement for submain wiring with copper conductor cable 2 runs of multi-stranded 6 Sqmm FRLS PVC, ISI marked with insulated unsheathed, drawn in and including PVC concealed conduit 25mm dia, medium grade ISI marked with all necessary conduit fittings, cutting chasing and 1x6 Sqmm copper conductor cable FRLS PVC insulated unsheathed multi-stranded using as continues earth wire connected to common earth and earth dolly, complete all as specified and directed.
S&F in replacement factory made MCB metalic distribution board 12 Way, double door, 230 Volts, concealed flush to wall for mounting MCBs, conforming to IS:13032, fabricated out of CRCA sheet fitted with DIN channel, neutral link and approriate rated bus bar, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature, between powder painting process to ensure smooth finish and protection against corrsion atmosphere. The DB shall be double door type with hinged door with locking arrangement. The DB shall be of same make as MCBs andl also be provided with lable marking indicating the incoming and outgoing circuits on all ways and shall be of IP-43 protection, complete all as specified and directed.
S&F in replacement MCB 63 Amp, SPN, 'C' series, 240 Volts, 50 Hz, 10 KA and other domestic loads including all terminals, fittings etc, complete all as specified and directed.
S&F in replacement MCB, SP,40 Amps, 'C' series, 240 Volts, 50 Hz, 10 KA, complete all as specified and directed.
S&F in replacement MCB, SP, 6-32 Amps, 'C' series, 240 Volts, 50 Hz, 10 KA, complete all as specified and directed.
S&F residual current circuit breaker (RCCB) / earth leakage circuit breaker (ELCB), AC type, double pole, 63 Amps, 30 mA, complete all as specified and directed.
M&L for earthing in repair/ replacement complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level), connected to earth lead of GI wire of 4mm dia by means of bolts, nuts and washers and including earthing pit charcoal, common salt, 20mm bore GI medium grade watering pipe, 15mm bore light grade GI protection pipe upto 5 mtr length, wire mesh and funnel, PCC pit in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate), angle iron (of suitable size) frame and RCC cover and all necessary earth work in any type of soil, complete all as shown in electrical plate No. 3 of MES SSR -2009 (Part-1) and testing on completion.
S&F rigid non metallic PVC conduit exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipehooks etc, complete all as specified and directed.
M/S GURU DEV BUILDERS (BID ID -3184864)
anil construction co. (BID ID -3183942)
M/S SUSHEEL KUMAR Govt. CONTRACTOR (BID ID -3183797)
sohtra and co (BID ID -3182070)
takashdeep traders (BID ID -3190694)
MADAN LAL SHARMA AND SONS (BID ID -3184444)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .