Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.0 L+₹2.3 L (40.8%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L2 | Rejected-AOC L2 | |
| 3 | L3₹9.2 L+₹3.6 L (63.0%)Rejected-AOC VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
Closing Date
28 Sept 2021, 6:00 pmClosed
AGE I TALBEHAT
LAKE VIEW CAMP MIL STN TALBEHAT 284125
SPL REPAIR OF 08 NOS APFC PANEL OF VARIOUS ZONE AT TALBEHAT MILITARY STATION
2021_MES_472139_1
AGE(I)/TBT/TOK-42/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MILITARY STATION TALBEHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I TALBEHAT
Exempted
18 Nov 2021
1 Sept 2021
30 Sept 2021
6 Sept 2021
28 Sept 2021
11 Sept 2021
Amount
Supply, installation, commissioning and testing in replacement of 30 KVAR Automatic Power Factor Correction (APFC) Panel board is fully automatic in operation and can achieve desired power factor 0.8 to 0.99 under fluctuating load condition, suitable shape and size as approved by the Engineer-In-Charge, outdoor cubical type PCC plinth mounted, outdoor type factory made, dust and vermin proof (Protection class IP-54) made out of 50 mm x 50 mm x 4 mm angle iron frame and 3.15 mm thick, MS CRCA sheet with front hinged opening, rubber lining, locking arrangement, painted externally and internally providing one coat of any corrosive coating and finally epoxy powder coating of flint grey shade (RAL-7032) an all steel surfaces complete with following:- (a) Incoming MCCB 63 Amp 35 KA 4 pole, 415 Volt, 50 Hz-01 No (b) Digital Volt meter 0-500 Volt-01 No (c) Digital Microprocessor controlled relay-01 No, auto switching system with indicating lamp-06 Nos, capacitor(as per load condition) with contactors -06 Nos (d) Complete wiring and PCC work.
Supply, installation, commissioning and testing in replacement of 50 KVAR Automatic Power Factor Correction (APFC) Panel board is fully automatic in operation and can achieve desired power factor 0.8 to 0.99 under fluctuating load condition, suitable shape and size as approved by the Engineer-In-Charge, outdoor cubical type PCC plinth mounted, outdoor type factory made, dust and vermin proof (Protection class IP-54) made out of 50 mm x 50 mm x 4 mm angle iron frame and 3.15 mm thick, MS CRCA sheet with front hinged opening, rubber lining, locking arrangement, painted externally and internally providing one coat of any corrosive coating and finally epoxy powder coating of flint grey shade (RAL-7032) an all steel surfaces complete with following:- (a) Incoming MCCB 100 Amp 35 KA 4 pole, 415 Volt, 50 Hz-01 No (b) Digital Volt meter 0-500 Volt-01 No, Phase indicating lamp-03 Nos (c) Digital Microprocessor controlled relay-01 No, auto switching system with indicating lamp-06 Nos, capacitor(as per load condition) with contactors -06 Nos (d) Complete wiring and PCC work.
Supply, installation, commissioning and testing in replacement of 70 KVAR Automatic Power Factor Correction (APFC) Panel board is fully automatic in operation and can achieve desired power factor 0.8 to 0.99 under fluctuating load condition, suitable shape and size as approved by the Engineer-In-Charge, outdoor cubical type PCC plinth mounted, outdoor type factory made, dust and vermin proof (Protection class IP-54) made out of 50 mm x 50 mm x 4 mm angle iron frame and 3.15 mm thick, MS CRCA sheet with front hinged opening, rubber lining, locking arrangement, painted externally and internally providing one coat of any corrosive coating and finally epoxy powder coating of flint grey shade (RAL-7032) an all steel surfaces complete with following:- (a) Incoming MCCB 160 Amp 35 KA 4 pole, 415 Volt, 50 Hz-01 No (b) Digital Volt meter 0-500 Volt-01 No, Phase indicating lamp-03 Nos (c) Microprocessor controlled relay-01 No, auto switching system with indicating lamp-06 Nos, capacitor(as per load condition) with contactors -06 Nos (d) Complete wiring and PCC work.
M&L in replacement of 25x4 sqmm LT UG cable XLPE insulated heavy duty electric cables with stranded aluminium conductor 1100 volts grade passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of aluminium lugs.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
HARNAM SINGH ANIL SINGH
M/S A.R BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .