Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.7 LAccepted-AOC VPO KHARKHARI TEHSIL LOHARU DISTRICT BHIWANI HR | BHIWANI | HARYANA | 127021 | 1 | Accepted-AOC FOUND LOWEST RATE | |
| 2 | 2₹3.7 L+₹6,967.53 (1.90%)Rejected-AOC | 2 | Rejected-AOC TECHNICAL AND FINANCIAL ELIGIBLE | |
| 3 | 3₹3.8 L+₹15,368.28 (4.20%)Rejected-AOC | 3 | Rejected-AOC TECHNICAL AND FINANCIAL ELIGIBLE | |
| 4 | 4₹4.5 L+₹83,319.49 (22.8%)Rejected-AOC | 4 | Rejected-AOC TECHNICAL AND FINANCIAL ELIGIBLE |
Tender Value
₹4.0 L
EMD Value
₹7,910
Closing Date
8 Oct 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
REGISTRAR
Registrar Office, CBLU, Bhiwani
renovation of Main Gate in existing Campus
2020_HRY_143396_3
CBLU/ENGG/20/6060
Open Tender
Civil Works - Buildings
Works
60 days
Registrar Office, CBLU
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Finance Officer
₹7,910
8 Dec 2020
16 Sept 2020
9 Oct 2020
16 Sept 2020
8 Oct 2020
16 Sept 2020
90 days
Amount
Renovation of gate
Providing and fixing of ACP (Aluminium Composite panel) 3 mm thick of make Alutech panels, VIVA, EURO BOND on walls with aluminium base frame (25 mm x 50 mm) and (20 mm x 35 mm) including cost of carriage, screws, fastener etc. completed fixed in position as approved by Engineer-in-charge (NS)
Dismantling brick work (HSR 8.5 b)
Scraping old plaster (HSR 8.32c)
Cement concrete 1:4:8 with stone aggregate 20 mm nominal size in foundation and plinth (HSR 10.38)
Cement concrete 1:1.5 :3 with stone aggregate 20 mm nominal size in foundation and plinth (HSR 10.42)
Precast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in Kerbs and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete at the ground level or in first storey (HSR 10.77)
Precast cement concrete 1:2:4 with stone aggregate 20 mm nominal size in tiles & Channels and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including form work, placing and fixing in position, complete at the ground level or in first storey (HSR 10.78)
Providing and laying 80 mm thick interlocking paver block of all shapes and colour in design mix cement M 35 over bed of 30 mm thick fine sand complete in all respect (HSR 10.159)
Precast chequered tiles (coloured) of 20 mm thickness in ordinary grey cement without ships laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings (HSR 14.45)
10 mm thick cement plaster 1:3 HSR (15.2)
12 mm thick cement sand plaster (HSR 15.5)
Providing and fixing of Flood LED Light 60 W of make Havells, Syska, Philips with wiring 4 mm thick including cost of fastener, nut bolt etc. complete fixed in position with necessary wire/cable for the nearest available connection as approved by Engineer-in-charge complete in all respect. (NS)
Providing and fixing of Letters of PVC Sheet 18 mm thickness inside, atleast height of letter is 15 inch including cutting cost of labour, adhesive etc. complete fixed in position as approved by Engineer-in-charge complete in all respect. (NS)
Providing and fixing 6 W round LED panel concealed light make Havells, Syska, Philips including the cost of labour and necessary fixing arrangement with 2.5 mm copper wire fixed in position as approved by Engineer-in-charge complete in all respect (NS)
Providing and fixing 30 W LED Street lights of make Havells, Syska, Crompton, Philips including the cost of labour, pipe stand, 4 mm wire, screws etc. complete fixed in position as approved by Engineer-in-charge complete in all respect (NS)
Applying priming coat with metal primer on new steel or iron work including preparation of surface (1st quality) (HSR 16.09)
Painting two coats on iron sheets with roofing red ready mixed paint on new work to give an even shade (HSR16.19)
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (1st quality) (HSR 16.25)
Providing two coats of exterior acrylic emulsion paint (HSR 16.79 b)
Wrought iron and mild steel (using angles, flats, square bars, tee and channels) ladders grills, grating frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc. including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
PANKAJ
BHUPENDER CONTRACTOR
UPENDER CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .