| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹32.8 L+₹5.3 L (19.2%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹35.9 L+₹8.4 L (30.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹38.7 L+₹11.2 L (40.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
CERTAIN REPAIRS AND MAINT WORKS OF HQ CEBZ HQ CWE AGE SI LINES ASCONE NODE NCC GROUP HQ SERVA DHARM STHAL AND OTHER MINOR UNITS AT SI LINES UNDER GE BHOPAL
2024_MES_665901_1
8307/E8
Open Tender
Civil Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹90,000
Yes
25 Oct 2024
13 Jul 2024
14 Sept 2024
13 Jul 2024
12 Sept 2024
27 Jul 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Material and labour for securing glass of any description in existing Metal/wooden frames glazed with putty/ beads including removing loose or decayed putty/ beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work (New length of frame reputtied shall be measured) complete all as specified and as directed.
Petty repairs to leaking water in bib taps, pillar taps, stop cock, angle valve, PVC connection, float valves, concealed stop cock, GI pipe joints bottle traps, PVC water tank, low level flushing cistern , CPVC/GI pipe fittings including replacing & providing of good quality rubber washer check nuts plunges, taflon tape, M-seal, brass spindles (specific type), GI/ brass/CPVC fittings etc or any other minor accessories / repairs to make the system all time functional, ensure smooth water supply without any wastage and stop water leakage complete all as specified and directed.
Supply and fixing 140mm overall length of cover plate floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring with lower portion fixed with hard rubber, fixed in floor complete all as specified and directed.
Supply and fixing in repair rubber base door strip fixed to bottom edge of door shutter using small nails / self adhesive type to minimize gap & avoid entry of incests inside house width & lenght as required at site complete all as specified and directed.
M&L for 40mm thick PCC, 1:2:4, type B-1 (using 20mm graded crushed stone aggregate), as in floor finishing surfaces of conc topping even and smooth with using extra cement .
Supply only glass dividing strips, 3mm thick, 38 mm wide laid in position conforming to design pattern as approved complete all as specified and directed.
M&L for machine cut, cudappah stone slab 20/25mm thick over cement at screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Material and labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Petty reapirs to half stall vitreous china urinal/sensor type urinal, including changing of sensor of flushing valve with complete kit complete all as specified and directed.
S&F in repair half stall vitreous china urinal white colour of size 710x480x300mm, Ist quality with sensotrinic, sensor flushing valve with complete kit including CP waste with PVC down waste pipe upto floor level (complete set) complete all as per manufacturer's instructions complete all as specified and directed. Make : Jaquar (Cat No. URS-WHT-0704, SNR-51097) or equivalent as approved by GE.
S&F for welding in repairs n. exc 2.5cm in length & n. exc 6mm thickness of metal existing sliding door bolt / tower bolt / handle of any size & material by welding at any location complete all as specified and directed.
S&F for welding in repair of ms hinges, helical door springs, rolling shutter spare parts heavy MS garrage doors etc. thickness of material n. exc. 6mm complete all as specified and as directed.
M&L for preparation of old decorated surfaces of wall including brooming, scraping down smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and one coat of white wash on walls complete all as specified and directed.
All as per item No. 13.00 here-in-before but on ceiling.
M&L complete removal of old decorated surface of wall and applying two coat of oil emulsion distemper white/coloured over and one coat of white cement based putty (whereever is required) all as specified and directed. Note:- Putty shall be measured and paid seperately.
M&L for preparation of old decorated surfaces of wall including brooming, scraping down smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and apply one coat of oil emulsion distemper complete all as specified and directed.
M&L for preparation of old painted surfaces of wood/wood based materials exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
All as per item No.17.00 here-in-before but on steel surfaces.
M&L for preparation of old plastered surface wall and applying finishing walls with acrylic smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall including brooming, scraping down smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and applying one coat of exterior weather proof water base emulsion paint on wall complete all as specified and directed.
M&L for one coat of 2mm thick average wall care putty on walls/ceiling complete all as specified and directed.
Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, finishing walls with textured exterior paint of required shade (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm compete all as specified and directed
Taking down chowkats or frames exc 1.50 sqm but n.exc 4 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down chowkats or frames n exc 1.50 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down shutters of any descripition exc 1 sqm and n exc 2 sqm each and removing to or from store complete all as specified and directed.
Easing of door shutters for easy closing / opening tightening of hinges or changing the position of hinges adjustment of tower bolts, sliding bolts with new screws etc complete all as specified and directed.
Easing of window shutters, kitchen cup board shutters, show case shutter drawers including fixing of screws adjusting handles, knobs tightening piano hinges incl misc small adjustments complete all as specified and directed.
Taking down shutters of any description and refixing in the same opening exceeding 1 Sqm but not exceeding 2 Sqm each complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15 mm bore GI tubing, medium grade, galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs CPVC pipe 15mm dia of grade SDR-11 (class-I) including all CPVC and brass fittings fixed to wall, floor or ceiling or laid in floors etc complete all as specified and directed.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specifiedand and directed.
S&F 20 mm bore GI tubing, medium grade, galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning in, making good to facings in brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar complete all as specified and directed.
M&L for fly ash brick work with straight or curved on plan to any radius in half brick thick walls using modular bricks build in CM 1:4 complete all as specified and directed.
M&L for fly ash brick work in CM 1:6 using modular bricks straight or curved on plan to any radius complete all as specifiedand and directed.
Demolition of concrete in ground floors and pavings (unreinforced) nexc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & mirror polishing complete all as specified and directed.
All as per item No. 41.00 here-in-before but for dados and similar work on skirting 20-25mm thick kota stone complete all as specified and directed.
M&L for cement concrete, 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection, 75mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L 25mm thick cement concrete type B-1, 1:2:4 (20 mm graded stone aggregate) complete all as specified and directed.
M&L screed bed or beding layer of mortar 15mm thick for laying floor finish in CM 1:4 complete all as specified and directed.
M&L rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:3 complete all as specified and directed.
M&L for vitrified light shade tiles 8 to 10 mm thick (square/rectangular) polished, area of each tiles not exceeding ) 0.36 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for vitrified light shade tiles 8 to 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm, as in vertical surfaces such as skirting, risers to steps, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with complete all as specified and directed.
M&L for vitrified light shade tiles 8 to 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 Sqm but exc not exceeding 0.42 Sqm, in floors etc, set and jointed in neat cment slurry and pointed in white or coloured cement to match surface of tile complete all as specified and directed.
M&L for vitrified light shade tiles 8 to 10 mm thick (Square/rectangular) polished, area of each tiles exceeding 0.36 Sqm but exc not exceeding .42 Sqm, as in vertical surfaces such as skirting, risers to steps, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with complete all as specified and directed.
M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exe 0.11 Sqm but not exe 0.18 sqm in floors etc. set and jointed in cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
All as per item No 52.00 here-in-before but on vertical surface
M&L for glazed ceramic tiles in vertical surfaces 350x250x7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
M&L for marble work 18-20 mm thick (Makrana white) (table rubbed and polished/ moulding) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing n white cement (1:2) using marble dust with admixture of pigment to mactch with shade complete all as specified and directed.
M&L granite work 18-20mm thick (of any type colour) (table rubbed and polished/moulding) in steps jambs, pillars, window cills, cooking platforms and like in cement morter (1:4) including pointing n white cemnt (1:2) using marble dust with admixture of pigment to match with shade or granite complete all as specified and directed.
M&L for Endura joint free colour tiles 8 to 10 mm thick (square/rectangular) area of each tiles not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles complete all as specified and directed.
M&L laminated wooden flooring including polishing all as per manufacturers direction, including taking old flooring complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat, channel etc for fixing etc. complete all as specified and directed.
Hacking out old broken glass (any thickness quality or description) from from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S&F 3mm thick plain sheet glass ordinary quality nexc 0.50 Sqm in each pane complete all as specified and directed.
S&F 4.0mm thick plain sheet glass ordinary quality nexc 0.50 Sqm in each pane complete all as specified and directed.
S&F 4.0 mm thick plain sheet glass ordinary quality exc 0.50 Sqm in each pane complete all as specified and directed.
S&F solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturer complete all as specified and directed.
M&L for 2nd class hardwood plain fillets, square, rectangular or triangular in section, wrought, fixed with nails, cross sectional area exceeding 13 sqcm but not exceeding 25 sqcm, complete all as specified and directed.
S&F 40 mm thick factory made flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete and fixed to chowkats complete all as specified and directed.
S&F Solid PVC Door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top & bottom rails, MS frame shall be covered with heat moulded palin colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame wlded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing tin the frame at site complete all as specified and directed.
S&F in repairs factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proofand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note:- Mild Steel hold fast/ lugs or SS dash fasteners shall be paid separately.
S&F for factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.
S&F Butt hinges for 100mm size butt hinges medium weight cold rolled mild steel complete all as specified and directed.
All as per item No. 71.00 here-in-before but for 125 mm long
S&F 150 mm long aluminium handles, cast type, anodised fixed to shutters complete all as specified and directed.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed to frames complete all as specified and directed.
S&F in repairs to Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed to frames complete all as specified and directed.
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed.
S&F 300mm ordinary MS rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L in repairs 25mm stainless steel curtain rod decorative type incl 2 nos curtain, fancy type, bracket & 2 nos of nobs complete all as specified and directed
Dismantling wall and ceiling boards of any description fixed in any position, any thickness including cover fillets complete all as specified and directed.
S&F for GI frame work size of grid 605 mm x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylong sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kuled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
M&L for providing and fixing 12mm gypsum board ceiling fixed with GI angle/channel frame work incl GI wire/ mesh, etc in different levels all complete including joints filled with paster of paris, putty including POP work/Cornices and applying two coat of oil bound distemper complete all as specified and directed.
S&F for galvanised cold rolled steel section framed work size 600x600mm grid size 24x38x0.60mm Tee (bottom precoated) and 24x24x0.50mm thick wall angle galvanised cold rolled steel section incl expansions fasteners as in ceiling complete all as specified and directed.
S&F 6mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed. Note:-Frame work for ceiling shall be measured and paid separately.
S&F inrepair to Solid PVC Wall Lining consisting of 5mm thick but wood grain printed PVC sheet used instead of plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F inrepair to 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
S&F 40mm wide of flap continuous (piano) hinges, brass , bright finish complete all as specified and directed.
S&F in repairs prelaminated partcle board 18/19 mm thick, exterior grade, prelaminated both side with decorative choice lamination fixed with nails to aluminium framed work fixed complete all as specified and directed.
S&F 100 mm brass handle , cast type, polished bright complete all as specified and directed.
Taking down cement plaster on brick or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L 15mm thick rendering intwo (10mm+5mm ) CM 1:4 on fair faces of brick/concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M&L 15mm thick rendering intwo 15mm CM 1:6 on fair faces of brick/concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M&L for 5 mm thick rendering in CM 1:3 on fair face of brick/ concrete surfaces as in ceiling complete all as specified and directed.
S&F in vitreous china squatting pan of Orissa pattern 580x440 mm white with integral foot rests ( excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in vitreous china wash down water closet pan (padestal pattern), white (excluding flushing costern and flush pipe) complete all as specified and directed.
S&F in PVC low level flushing cistern of 10 Litres with all internal fittings incl flush pipe and fixing to supply pipe complete all as specified and directed.
S&F in repairs Vitreous china wash hand basin white flat back of size 550 x 400mm excluding tap but including brackets/CP brass 32mm waste coupling complete all as specified and directed.
S&F 400 mmx 350mm mirror with PVC cabinet of standard make like commander/Prayag including all fittings as accessories complete all as specified and directed.
S&F in Stainless steel sink, 1.00mm thick for kitchen, with plug, washers and wastes/coupling, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm with bowl size 410mmx 330mmx 160mm fixed complete all as specified and directed.
S&F in repairs 15 mm Angle valve stopcock cast copper alloy, screwed down high pressure chromium plated screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs 15 mm bib taps cast copper alloy, screwed down high pressure chromium plated screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15 mm pillar taps cast copper alloy, with capstain head .chromium plated screw down high pressure, with or without lettered HOT or Cold with long shanks and fly-nuts screwed for iron pipes and fixed including necessary small GI fittings complete all as specified and directed.
S&F in repairs 15 mm CP Sink cock with raised "J" shapped swinging spout (wall mounted model) with connectng legs & wall flanges complete all as specified and directed.
S&F in repairs 15 mm CP single lever sink mixer with swingng spout on upper side (wall mounted model) with connectng legs & wall flanges complete all as specified and directed.
Fixing only in repair Mixing valve including three joints to steel pipes or unions and plugging and screwing to walls complete all as specified and directed.
S&F inrepair 15 mm wash basin mixutre, single lever extended basin mixer (height 95mm ) with popup wase system with 450mm long braided hoses , chromium plated, screwed down high pressure, screwed for iron pipe etc and fixed complete all as specfied and directed.
S&F inrepair CP Health faucet suitable for 15mm bore with connecting pieces including all necessary fittings and accessories complete all as specified and directed.
S&F PVC connection 15mm size of 450mm with PTMT nuts supplied and fixed in repairs complete all as specified and directed.
S&F PVC connection 15mm size of 600mm with PTMT nuts supplied and fixed in repairs complete all as specified and directed.
S&F in Plastic water closet seat cover, any colour, closed pattern with flat bottom, and mild steel chromium plated for aluminised hinging device complete all as specified and directed.
S&F in stainless steel single towel rail 600 mm long and 20mm dia complete all as specified and directed.
S&F in repairs CP towel ring round with round flange complete all as specified and directed.
S&F in repair to CP Towel rack 600mm long with lower hangers complete all as specifed and directed. Make :- Jaguar or Equivalent
S&F in repairs CP toilet paper holder with stainless steel flap complete all as specified and directed.
S&F in repairs overhead square shower with rubit cleaning system 150mmx150mm complete all as specified and directed. Make :- JAQUAR( Cat No OHS -354495) or Equivalent
S&F in repairs 15mm single lever wall mixer exposed shower with provision for connection to exposed shower pipe & hand shower with connecting legs & wall flanges complete all as specified and directed. Make. Prayag or Jaquar or equivalent.
S&F in repairs 15mm single lever wall mixer exposed shower with provision for connection to exposed shower pipe with connecting legs & wall flanges complete all as specified and directed. Make. Prayag or Jaquar or equivalent.
S&F 15 mm bib cock two way with flange, cast copper alloy, fancy type, chromium plated screwed down for iron pipe and fixed in repairs complete all as specified and directed.
S&F 15 mm Angle valve two way with flange, cast copper alloy, fancy type, chromium plated screwed down for iron pipe and fixed in repairs complete all as specified and directed.
S&F inreapir soap dish holder of bootom CP and glass holer for soap complete all as specified and directed.
S&F in repairs glass shelf (with bracket) of 22 inch long chromium plated fixing complete all as specified and directed.
S&F in repair corner glass shelf (with bracket) all as specified and directed
S&F wash down water closet with seat cover , waste pipe, cistern with lid & fittings (complete set) and fixing complete all as per manufacturere instructions complete all as specified and directed. Make:- Hindware (Cat No: 92045) or equivalent
Dismantling Asbestos cement (Corrugated, semi corrugated, etc) sheets including ridges in roof covering complete all as specified and directed.
Dismantling timber santiling in fillets rails, posts, rafters, purlins, etc under 40 Sqcm in section unframed work complete all as specified and directed.
M&L preparation of New or previouly untreated surface of steel and iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Pre-painted galvatume aluminium Zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified complete all as specified and directed.
All as per item No 129.00 here-in-before but plain sheeting, in ridges
M&L Fibre glass reinforced translucent corrugated sheeting with two corrugations sid lap fixed with L type or J type or cranked hook bolts complete all as specified and directed.
M&L for 2 mm thick Fibre glass reinforced translucent Plain sheeting with sid lap fixed with L type or J type or cranked hook bolts complete all as specified and directed.
M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering,doors, etc to be prepared for hanging or sliding with and including either hooks and hingsor steel hanging door fittings(including of steel sheeting or other covering.(Fe-410-W(Gde-E250) complete all as specified and directed.
M&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F MS work as in bands, straps, clamps, hold fasts, wall ties, hooks for hanging fans and smilar articles complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store complete all as specified and directed. Not:- Measured overall as fixed along the centre line over fitting and accessories.
S&F 75 mm PVC(SWR) pipes Single socketed in any length with rubber rings joints laid in trenches or in floors complete all as specified and directed.
S&F PVC(SWR) 110mm pipes Single socketed in any length with rubber rings joints laid in trenches or in floors complete all as specified and directed.
S&F 75mm PVC(SWR) bend complete all as specified and directed.
S&F 75mm PVC(SWR) junction single (single 'T') equal or unequal complete all as specified and directed.
S&F 75mm PVC(SWR) vent cowl complete all as specified and directed.
S&F110mm PVC(SWR) vent cowl complete all as specified and directed.
M&L PVC (SWR) floor trap plain with grating incl jointing with solvent cement 75mm bore complete all as specified and direcetd.
S&F PVC(SWR) 110 mm bend complete all as specified and directed.
S&F in repair looking mirror approved quality with wooden back and edge, complete polishing , fixing in repairs complete all as specified and directed.
M&L grinding and polishing kota/marble/terazoo/mosaic flooring complete all as specified and directed.
Dismantling water tanks of Exc 500 litres but n exc 1000 litre capacity and removing to store complete all as specified and directed.
S&F 500 ltrs capacity Rotational moulded 3 layer HDPE water storage tanks (Cylindrical vertical with closed top) Dimen hoisted and fixed in position all as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed
S&F 1000 ltrs capacity Rotational moulded 3 layer HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in IS Code -12701-1996 including 20mm dia tank nipple complete all as specified and directed
S & F 20 mm dia ball valve PTMT, high pressure with polythene float and fly nut complete, screwed for iron pipe with epoxy coated aluminium rod complete all as specified and directed.
S & F in repairs gunmental, globe or gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs 12mm thick toughfen glass in door, partitions etc similar work etc in approved shape and design complete all as specified and directed
S&F in repairs stainless steel plate rack complete assembeled set of (Size: 31 x 36 x 10 inch) fixed with screws complete all as specified and directed.
S&F in repairs stainless steel plate rack complete assembeled set of (Size: 24 x 30 x 10 inch) fixed with screws as specified and directed
S&F in reapirs 18mm plywood grade BWR, type BB fixed with screws to timber frame work complete all as specified and directed
S&F in reapirs 0.9mm thick decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker's instructions complete all as specified and directed
S&F in repair to magnetic catcher for cupboard shutter complete all as specified and directed
S&F 105x60 mm pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate, etc. complete as specified made out of 1.25mm thick ms sheet complete all as specified and directed
S&F 125x60 mm pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate, etc. complete as specified made out of 1.25mm thick ms sheet complete all as specified and directed.
S&F in repair to Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F in repair to Aluminium (Extruded section body ) Door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed complete all as specified and directed.
M&L for Cabinet Hinges Soft Close SS 8 Crank complete all as specified and directed
Taking down existing old roof treatment of any description , any type including removal old Tar felt, screed bed and plastering etc complete all as specified and directed.
M&L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and applying APP modified bituminous water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (total weight of the finished membrane not less than 3.8 kg/ sqm ± 5 % per sqm) confirming to IS 16532: 2017 over a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25⁰C, 0.87-0.89 kg/ litre and viscosity 70-160 cps, laying over the primer coat using Butane Torch and sealing all joints, overlapping etc. as per Annex D of IS 16532: 2017 complete all as specified and as directed.
M&L for ponding test by filling 75 mm deep water over roof treatment by making necessary arrangement to fill the complete Roof slab at least for 72 hrs complete all as specified and directed.
M & L for cement concrete type B0 1:2:4 (12.5mm graded aggregate ) benching/ angle filleting at the junction of parapet and RCC roof complete all as specified and as directed.
M & L for cutting grooves or chase in brick wall, 75 mm wide and 65 mm deep and including filling with cement mortar 1:4 mixed with water proofing as mentioned in Annex D of IS 16532: 2017, IS 16540: 2017 compound complete all as specified and as directed.
Material & labour for rendering 10 mm thick in cement mortar 1:4 over RCC slab mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately.
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid for separately.
M&L for grout of permanent bonding of strutural damage/crack, porosity of concrete to attend leakage/seepage with pressure grouting with 15mm bore GI Pipe Nozzle under the pressure of 5 kg/sqcm using cement based grout, treatment to be made as per instruction complete all as specified and directed.
M&L for tiles cleaning by using appropriate chemical of approved make with using prescribed machine also as necessary to remove stain/ dust etc and maintain beauty of tiles in MD Accn complete all as specified and directed.
Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Refixing of GI tubing medium grade 15 mm dia after cleaning of pipe with all fittings and fixed complete to walls and ceiling or laid on floors at complete all as specified and directed.
Refixing of GI tubing medium grade 20 mm dia after cleaning of pipe with all fittings and fixed complete to walls and ceiling or laid on floors at complete all as specified and directed.
Refixing of GI tubing medium grade 25 mm dia after cleaning of pipe with all fittings and fixed complete to walls and ceiling or laid on floors at complete all as specified and directed.
S&F 25 mm bore GI tubing medium grade, galvanised with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed.
S&Fof 20 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc Make : Prayag
S&F in repair to 25 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F in repair to 20 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F in repair to 15 mm PVC float valve high pressure of PTMT with epoxy coated aluminium rod & hight density plastic ball complete screwed for iron pipe or brass furred and fixed with fittings such as (socket, nipple, union) etc complete all as specified and directed.
S&F in repair to gunmental, globe or gate valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed.
S&F in repair to gunmental, globe or gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed.
S&F in repair to gunmental, globe or gate valves 15 mm dia with iron wheel head, screwed both ends for iron pipe and fixed.
S&F in repair to PVC tank lid (Cover) for tank of 500 Ltr capacity including locking arrangement with pad lock if required of Godrej size 50 mm (steel) comlete all as specified and directed.
S&F in repair to PVC tank lid (Cover) for tank of 1000 Ltr capacity including locking arrangement with pad lock of Godrej size 50 mm (steel) if required comlete all as specified and directed.
M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity not exceeding 500 Ltr of any description and in any position comprising following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using Trebac G5/Inchlor-5/NB-10, Terbac G65/Inoxi-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) First stage is to drain out the water by using exit valve or our own high capacity dewareing systems or any other suitable method approved by Engr-in-Charge. (b) Second stage is cleaning all the algae formation inside the tank by using Terbac G 10/ Inchlor-5/NB-10, a laboratory tested barnded chemical of the company and scrubbing the walls of the tanks. (c) Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSL. (d) Fourth stage first bacteria screening and Sterilization by using Terbac G5/Inchor-5/ NB-10, a Laboratory certified branded halogen compound, test certificate of Terbac G5/Inchor-5/ NB-10, from government laboratory mentioning suitability for sterilization. (e) Fifth stage is cleaning the floors of the water tank by heavy duty industrial vaccum cleaner. (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria. g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TerbacG65/Inoxi-60/NB-69. Note:- (i) Test certificate of Terbac G65/Inoxi-60/NB-69 from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (iii) Contractor will be responsible for rectification of complaints occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/blockage of Outlet lines due to silt and rectification cost will be deemed to be included in quoted rate.
M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity exceeding 500 Ltr but not exceeding 1000 ltrs of any description and in any position comprising following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using Trebac G5/Inchlor-5/NB-10, Terbac G65/Inoxi-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) First stage is to drain out the water by using exit valve or our own high capacity dewareing systems or any other suitable method approved by Engr-in-Charge. (b) Second stage is cleaning all the algae formation inside the tank by using Terbac G 10/ Inchlor-5/NB-10, a laboratory tested barnded chemical of the company and scrubbing the walls of the tanks. (c) Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSL. (d) Fourth stage first bacteria screening and Sterilization by using Terbac G5/Inchor-5/ NB-10, a Laboratory certified branded halogen compound, test certificate of TerbacG5/Inchor-5/ NB-10, from government laboratory mentioning suitability for sterilization. (e) Fifth stage is cleaning the floors of the water tank by heavy duty industrial vaccum cleaner. (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria. g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TerbacG65/Inoxi-60/NB-69. Note:- (i) Test certificate of Terbac G65/Inoxi-60/NB-69 from Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scale and the same shall be reconnected after cleaning the OHT and the quoted rate is deemed to include for this provision. (iii) Contractor will be responsible for rectification of complaints occurred during cleaning of tank i.e. No water in tank/ Over flow due to broken of float valve/blockage of Outlet lines due to silt and rectification cost will be deemed to be included in quoted rate.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconneting and refixing in position capacity exc 250 and n exc 500 ltr. including cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipes etc complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconneting and refixing in position capacity exc 500 and n exc 1000 ltr. including cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipes etc complete all as specified and directed.
Taking down carefully existing point wiring (any type, aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
M&L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FRLS cables 1.5 sqmm as per IS 694:2010, ISI marked, annealed multistranded copper conductor drawn through and including, medium grade, machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting/metal flush box/ cover plate/junctiion boxes/inspection cover etc, ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FRLS cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1:3 including necessary plaster and pointing in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed (Note cost of cutting chase and making good shall be included in the quated rates & wiring to be done as per approved colour code in IE rule complete all as specified and directed.
All as per ser item No 191.00 here-in-before but for one switch socket combination 5/6 amp on independent board
All as per Srl item No 191.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches
All as per Srl item No 191.00 here-in-before but for one switch socket combination 6 pin 5/15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.
All as per Srl item No. 191.00 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire
M&L for casing caping/conduit point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FRLS cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LS cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed (Note cost of cutting chase and making good shall be included in the quated rates & Wiring to be done as per approved colour code in IE rule complete all as specified and directed.
All as per Srl item No 196.00 here in before but for one light point controlled by 5/6 A two 2-way switches
All as per Srl item No 196.00 here in before but for one switch socket combination 5/6 amp on independent board
All as per Srl item No 196.00 here in before but for one three pin socket outlet 5 Amp on same board with other switches
All as per Srl item No. 196.00 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.
All as per Srl item No. 196.00 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire.
S&F in repairs switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and directed.
S&F in repairs switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F in repairs Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F in repair switch piano, one way, single pole, 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 3 pin 5 and 15 Amp, flush type, 240 volt AC complete all as specified and as directed.
S&F in repairs socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed.
S&F in repairs switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC with PVC Back Cover ISI marked complete all as specified and as directed.
S&F in repairs ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed.
S&F in repairs Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed.
Supply and fixing angle holder, PVC/Poly carbonate type with back plate suitable for batten fittings complete all as spcified and directed.
Supply and fixing in replacement of dismantling and removing of 36/40W tube light fitting patty/box/decorative/any type and replacement with LED type tube light fitting, surface mounted lumanaires, decorative ultra slim round /square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps,connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible 3 core copper conductor cable of suitable size complete all as specified and directed. Note :- Contractor will produce manufacturer test certificate & min 2 year warrenty from date of fixing.
S&F in replacement warm white in colour LED tube light complete fitting, surface mounted luminanaires, 18 watt, 240V, decorative ultra slim round/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with bipin holders, LED Lamps, connector block, etc complete with all accessories internally prewired and including connecting up with flexible 3 core copper conductor cable with suitable size complete all as specified and directed. Note :- Contractor will produce manufacturer test certificate & min two year warrenty from date of fixing.
S&F in replacement of white LED tube light fitting two feet 10 watt, slim design, 230 volts, including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Note :- Contractor will produce manufacturer test certificate & min two year warrenty from date of fixing.
S&F in replacement of warm white LED tube light fitting two feet 10 watt, slim design, 230 volts, including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Note :- Contractor will produce manufacturer test certificate & min two year warrenty from date of fixing.
S&F in repairs ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush/socket type complete all as specified and as directed.
S&F PVC insulated unsheathed, ISI marked FRLS copper cable, 1.5 Sqmm AC 230 V complete all as specified and directed.
S&F PVC insulated unsheathed, ISI marked FRLS copper cable, 2.5 Sqmm AC 230 V complete all as specified and directed.
S & F modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S & F modular switch, one way, 16 Amp, one module, 240 volts complete all as specified and directed.
S & F modular Bell Push switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F modular socket outlet 2-in-1, 5pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed.
Supply and fixing modular switch socket combination, multipurpose 6 pin, 16 amp, 3 module complete all as specified and directed.
Supply and fixing modular fan regulator, 5 stepped, high speed complete all as specified and directed.
S & F modular metal flush box of 6 module complete all as specified and directed.
S & F modular metal flush box of 4 module complete all as specified and directed.
S & F modular metal flush box of 3 module complete all as specified and directed.
S & F modular white cover plate with frame of 6 module complete all as specified and directed.
S & F modular white cover plate with frame of 4 module complete all as specified and directed.
S & F modular white cover plate with frame of 3 module complete all as specified and directed.
Taking down unserviceable sub main wiring including service connections, of any size and any description including conduit pipe and making good disturbed surface of walls/ ceiling to match with existing surface after necessary rewiring complete all as specified and directed .
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including MCCB/MCB and wooden boards complete all as specified and directed.
S&F sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 amps rated busbar, 4 way, double door, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP-43 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. NOTE:- MCB shall be measured and paid seperatly.
Supply and fixing factory made epoxy powder coated distribution board TPN, 4 ways (VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated neutral bar, insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed. NOTE:- MCCB shall be measured and paid seperatly.
S&F sheet metal enclosure double door type surface mounted concealed in wall 8 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. NOTE:- MCB shall be measured and paid separately.
S&F sheet metal enclosure double door type, surface mounted concealed in wall 12 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. NOTE:- MCB shall be measured and paid separately.
S&F MCCB 160 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed.
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 6 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 40 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCB SPN suitable for 240 volts, 'B' curve, AC supply 6 to 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed.
S & F in repairs MCB SPN suitable for 240 volts, 'B' curve, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F in repairs MCB TPN suitable for 240 volts, 'B' curve, AC supply 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F in repairs MCB TPN suitable for 240 volts, 'B' curve, AC supply 100 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F in replacement 3 pin plug, AC-230 V, 5 Amp, complete all as specified and directed.
S&F in replacement 3 pin plug top, AC-230 V, 15 Amp complete all as specified and directed.
S&F in replacement sheet metal earth plug & socket, single pole and neutral with and including 1no. single pole MCB 20 Amps 240 volts complete all as specified and directed.
S&F in replacement PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC,
S&F non metallic rigid PVC casing and caping ISI marked of 20mm size complete all as specified and directed.
S&F non metalic PVC conduit ISI marked of size 20mm dia complete all as specified and directed.
S&F in replacement LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt white in colour with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core complete all as specified & directed.
S&F in replacement LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt Warm white in colour with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core complete all as specified & directed.
Supply and fix in repairs coral post top lantern fitting 25 Watt ( for Gate light), energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories and with PVC insulated multistranded copper flexible cable 0.5 sqmm three core all as specified and directed by Engineer in charge.
S&F in replacement building security light fitting made up of pressure die cast alluminium housing with high efficient 30 Watt LED as lighting source and pc over having top opening separate driver compartment with IP-66 Protection and including IK-07 protection suitable galvanized iron pipe ,light grade, brackets 1 mtr length bent to shape to obtain required shape including clamps, nuts/bolts/washers etc connecting with with PVC insulated multistranded copper flexible cable 0.5 sqmm three core copper wire complete all as specified and directed.
S&F in replacement flexible wire three core copper conductor of size 23/0.0076 for ceiling fans ,light fittings etc complete all as specified and directed.
Supply and fix in replacement of LED slim square/circular panel light fitting for surface ceiling light 12 watt, colour warm white including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
Supply & fixing in replacement recess mounting spot LED light round downlighter designed with excellent thermally managed luminaire 12 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible coppder conductor cases of suitable size complete all as specified and directed by Engineer in charge
Supply & fixing flexible LED strip uses high brightness SMD LED as the light source for indoor application only, luminaire 24 watt, 220V AC with high efficiency light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with three core flexible coppder conductor cases of suitable size (Flexion Neo Led Strip 24 W of any colour) complete all as specified and directed by Engineer in charge
M&L in replacement for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe, medium grade, for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S&F in repairs 11 x 13 inches laminated hylem sheet cover, ISI marked of Make" Hylem" including cutting grooves for mounting of fittings like switches, sockets, fan regulators etc; including fixing in location with new galvanised screws and cup washer complete all as specified and directed
All as per item No. 262.00 here-in-before but of size 9 x 11 inches
All as per item No. 262.00 here-in-before but of size 5 x 8 inches
All as per item No. 262.00 here-in-before but of size 5 x 5 inches
Dismantling of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm (collected from MES fan store ) any make / model except old vintage, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES fan store after testing complete all as specified and directed.
All as per item No. 266.00 here-in-before but exhaust fan, 400/450 mm sweep, AC single phase, 230/240 volts
All as per item No. 266.00 here-in-before but exhaust fan, 300/380 mm sweep, AC single phase, 230/240 volts
All as per item No.266.00 here-in-before but exhaust fan, 230/250 mm sweep, AC single phase, 230/240 volts
All as per item No. 266.00 here-in-before but wall / pedestal fan, of any sweep and capacity
S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of clips for down rod with rubber bush (Garari) including set of nut bolts and washer, pin complete all as specified and directed.
S&F in replacement rubber bush (Garari) for mounting at upper side of down rod clip complete all as specified and directed
S&F in replacement gun metal bush self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed
S&F in replacement Fan condenser 2.5 mfd, 230 volts complete all as specified and directed.
S&F in replacement Fan condenser 3.15 mfd, 230 volts complete all as specified and directed.
S&F in replacement Fan condenser 4.0 mfd, 230 volts complete all as specified and directed.
Supply only bearing No 6201'ZZ' for fixing against defective bearing of fan taking down complete all as specified and directed.
All as per item No. 278.00 here-in-before but bearing No 6202'ZZ'
All as per item No. 278.00 here-in-before but bearing No 6203'ZZ'
All as per item No. 278.00 here-in-before but bearing No 6204'ZZ'
Taking down ceiling/wall fan from fan hook and disconnection from ceiling rose, dismantling of fan parts i e. down rod and connector/condenser, nut bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting/reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
Taking down exhaust fan and disconnection from ceiling rose, dismantling of fan parts i e. connector/ condenser, nut bolts, condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting/reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 450 mm /380 mm sweep exhaust fans complete all as specified and directed.
S&F in repairs top and bottom canopy of ceiling fan (any sweep) of make , colour and pattern as per existing model all as specified and directed
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 230 mm /300 mm sweep exhaust fans complete all as specified and directed.
M&L for painting of ceiling fan upto 1200/1400mm sweep with two coats of DUCO paint (ISI grade) white using spray machine. Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES No in all ceiling and Exhaust fan complete all as specified and directed. Note:- Taking down and fixing of fan will be measured under relevent item.
All as per item No. 287.00 here-in-before but for exhaust fan upto 280/300/380/450 mm sweep with smoke grey paint complete all as specified and directed.
Dismantling geyser of 25 ltrs capacity and of any description and M&L for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/scale is removed and approved by the Engineer-in-Charge, brazing for stopping the leakage of copper inner tank/ gas welding for stopping the leakage of inner steel tanks, fixing the serviceable parts in position, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing and painting, fixing & installation of the geyser in position and its testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. NOTE:- (i) De-scaling chemical shall be concentrated HCL of make as approved by GE. (ii) Painting of Geysers shall be on requirement basis and shall be measured and paid for separately under appropriate item of schedule. (iv) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool and additional quantity of glass wool for insulation, if any required, is deemed to be included in the quoted unit rate. (v) Spares parts as required shall be measured and paid seperately.
All as per Item Sl No. 289.00 here-in-before but geyser of capacity 50 Ltrs complete all as specified and directed.
S&F 1.5 KW capacity Heating Element (ISI marked) round type/thread/triangle / Push/ Screw base type with ‘O’ ring including making electrical connection complete all as specified and directed.
S&F 2.0 KW capacity Heating Element (ISI marked) round type/thread/triangle/ Push/ Screw base type with ‘O’ ring including making electrical connection complete all as specified and directed.
S&F electronic Heating Element (ISI marked) fitted with auto cut thermostat 1.5/2.0 KW suitable for 25/50 ltr geyser including making electrical connection complete all as specified and directed.
S&F in replacement Geyser assembly suitable for 25 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement Geyser assembly suitable for 50 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement thermostat suitable for 25/50 Ltr Geyser ISI marked with setting range 30 C to 80 C suitable for 230 volts AC electric supply complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geyser complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement indicating lamp (set of two) 230 volts 50 HZ AC suitable for geyser any type (round, square or rectangular type) any capacity complete all as specified and as directed.
M&L for painting of geyser, 25 ltr capacity with two coats of DUCO paint (ISI grade) white using spray machine, spray painting including cleaning, washing and preparation of old painted surfaces including writing MES No. complete all as specified and directed.
All as per item No. 304.00 here-in-before but of 50 ltr capacity.
S&F in replacement PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in replacemnt PVC connections 15 mm size nylon braided, heavy duty, 450mm long including rubber washers (suitable for hot water) complete all as specified and directed.
S&F in replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 68122.00
MS MOHD RIZWAN KHAN (BID ID -3094089)
M/s H V Infra Projects (BID ID -3086544)
SHIV SHANKAR MISHRA (BID ID -3087919)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .