| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC H NO 787 22 JHANG COLONY ROHTAK 124001 | ROHTAK | HARYANA | 124001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹21.7 L+₹1.1 L (5.56%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance Higher | |
| 3 | L3₹22.4 L+₹1.8 L (8.64%)Rejected-Finance SCF 15 HUDA COMPLEX 184 NEW IDC 124001 | ROHTAK | HARYANA | 124001 | L3 | Rejected-Finance Higher | |
| 4 | L4₹23.6 L+₹3.0 L (14.4%)Rejected-Finance 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | L4 | Rejected-Finance Higher |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
28 Feb 2020, 5:00 pmClosed
Ravi Ladwal, EE
Executive Engineer Elect. Division PWD B and R Hisar
Special Repair to A and B (5 Store Bed) Block Connected Passage at Ramp in the Campus of Civil Hospital at Bhiwani (S/R to Electric Room and Main Cables and Panels Etc.).
2020_HRY_118094_1
PWD/Elect-GGR/Elect-HSR/16887
Open Tender
Construction Works
Works
120 days
Hisar
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, Elect. Division PWD B and R Br
₹43,000
16 May 2020
13 Feb 2020
3 Mar 2020
13 Feb 2020
28 Feb 2020
13 Feb 2020
Amount
Molded case Circuit breakers: Supply and erection of molded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. (HSR 31.12 (C). ii) 100 amp.to 220 amp.415 V,10 KA 3-phase.
iv) 300 amp. to 400 amp. 415 V , 35 KA 3-phase.
v) 500 amp. to 600 amp. 415 V , 35 KA 3-phase.
(Q) Earthing (HSR 31.22) iv) Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
v) Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
x) Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required .
xiv) Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material.
Under Ground Cables:- Supply and erection of underground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (HSR 31.25) xxvii) 70 Sq. mm 3.5 Core Ard. Cable .
xxix) 95 Sq. mm 3.5 Core Ard. Cable .
xxx) 120 Sq. mm 3.5 Core Ard. Cable .
xxxii) 185 Sq. mm 3.5 Core Ard. Cable .
xxxiii) 240 Sq. mm 3.5 Core Ard. Cable.
Supply and erection of underground cable ,loose in existing pipe or trenches complete with necessary connections. ( HSR 31.26) xxviii) 70 Sq. mm 3.5 Core Ard. Cable.
xxix) 95 Sq. mm 3.5 Core Ard. Cable.
xxx) 120 Sq. mm 3.5 Core Ard. Cable.
xxxii) 185 Sq. mm 3.5 Core Ard. Cable.
xxxiii) 240 Sq. mm 3.5 Core Ard. Cable.
Supply and erection of suitable compression type brass cable glands for underground Cable. (HSR 31.28) iv) 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core .
v) 120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core
Supply and erection of aluminum lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. (HSR 31.35) ix (h) 70 sqmm .
ix (i) 95 sqmm .
ix (j)120 sqmm .
ix (l)185 sqmm .
Supply installation testing and commissioning of wall/ free standing floor mounting dust and vermin proof compartmentalized cubical panel made out of 2mm thick CRCA street, required hardware 3 mm thick bakelite sheet provided all along with bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc/ Red oxide primer followed by 2 coat of powder coating in gray or required shade after rising. The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking agreement for equipment / switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars upto cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. the panel will be complete with control wiring (copper) and fuse protection ( only outer area on all sides shall be measured) (HSR 31.63).
Supplying and fixing of copper bus bar duly tinned by means of SMC / BMC type insulatter high tensile nuts and bolts spring washer fixing to same in existing pannel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect. (HSR 31.64).
Supply and fixing of rotary handle for on/off operation of existing MCCBs in the L.T panel including fixing the same in position with all labour and material required to complete the job in all respect. (HSR 31.66). i) Rotary handle upto 125 A MCCB
ii) Rotary handle above 125 A MCCB
Supply and errection of double walled corrugated (DWC) HDPE pipe laid 1 meter below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of the labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (HSR 31.67). ii) HDPE pipe 90/75 mm outer dia / inner dia
Supply and erection of module case circuit breaker single pole/ 4 pole on wall /on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. (HSR 31.69). vii) 4 Pole MCCB 300 amp to 400 amp.
Supply & erection of cable tray made out of 2 mm thick galavanised perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the Job in all respect upto the Entire statisfaction of Engineer-in-Charge of the work. (HSR 31.81). i) 40 x 100 mm
ii) 50 x 150 mm
iii) 50 x 300 mm
Supply & erection of factory manufactureed cable tray cover made of 16g GI Sheet complete with Fastoner Nuts bots and in position including all petty material required to complete the Job in all respect upto the Entire statisfaction of Engineer-in-Charge of the work. (HSR 31.82) i) Size for 40 x 100 mm
ii) Size for 50 x 150 mm
iii) Size for 50 x 300 mm
Non Schedule Items Supply of ABC Stored Pressure type Fire Extinguisher 6kg. Capacity (5 year warranty) bearing ISI Mark for firefighting ABC class of fire extinguisher will be manufactured strictly as per BIS IS:15683:2006 bearing ISI Mark EN3 615 approved powder (Safex/ Minimax/ Ceasefire Make).
Supply of Co2 type Fire Extinguisher 4.5Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark (Safex/ Minimax/ Ceasefire Make).
Supply and erection of Rubber Mat 1mx2mmx 3mm thick suitable for 11/33 KVA as per IS No. 15652C/M/L 3017739 as per approved by Chief Electrical inspector, Govt. of Haryana with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work
Supply / erection/ Testing / commissioning of 800 amp 4 pole 50 KA ACB MDO (Mannual draw out type) with microprocessor based release for over current, short circuit & earth fault in existing LT panel including labour charges complete in all respect upto the entire satisfaction of the Engineer-in Charge of the work.
Supply & erection of ACB of 1600 amp 4 pole 50 KA with microprocess based release for over current, short circuit & earth fault in existing LT panel including labour charges upto the entire satisfaction of the Engineer-in Charge of the work.
M/s JSB Enterprises
Highlight Associates and Contractors
J.B.S.Electrical Co.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .