| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹1,760
Closing Date
7 Dec 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2020_PWDJK_110361_2
e-NIT No.EDJ/116 of 2020-21 Dated 01-12-2020
Open Tender
Electrical Works
Item Rate
25 days
Govt College Women Udhampur
please refer to NIT
3 documents required · 3 mandatory
₹600
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹1,760
Yes
9 Dec 2020
1 Dec 2020
8 Dec 2020
2 Dec 2020
7 Dec 2020
2 Dec 2020
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed conduit as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 Sq.mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing following sizes/ Modules, GI box along with modular base and cover platefor modular switches in recess etc. as required.
6 Module
8 Module
12 Module
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
Supplying and fixing of Electrical items.
Round Sheet
Fan Sheet
Fan Box
Deep Box
Angel/Batten Holder.
LED Bulb 15 watt
SPN 63 Amp
Aluminium cable 25 sq. mm twin core
10/12 watt LED 2 feet long tube light fitting/fixture batten type
Supplying and fixing of 20/22 watt LED 4 feet tube light fitting/fixture Aluminium housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F 70.95 THD < 16%
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply.
Ceiling fan 1200 mm sweep along-with rod up-to 1'-6" long as required.
Exhaust fan 300 mm sweep metalic
JAGDISH KUMAR
DEV RAJ MAGOTRA
M/S S.K GUPTA & CO.
Ganesh Sharma
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .