| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC 90 1 287 1 ADARSHA PARA PURBA BIDHYHARPUR SHYAMNAGAR 24 PGS N PIN 743127 | SHYAMNAGAR | NORTH 24 PARGANAS | WEST BENGAL | 743127 | L1 | Accepted-AOC Quoted rate stands Lowest (L1) | |
| 2 | L2₹2.0 L+₹213.50 (0.11%)Rejected-Finance | L2 | Rejected-Finance Rejected due to high
rate | |
| 3 | L3₹2.0 L+₹2,439.79 (1.22%)Rejected-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | L3 | Rejected-Finance Rejected due to high
rate | |
| 4 | L4₹2.0 L+₹4,096.39 (2.05%)Rejected-Finance 1008 LASKARHAT FLAT 2A 2ND FLOOR KOLKATA 700107 | KOLKATA | KOLKATA | WEST BENGAL | 700107 | L4 | Rejected-Finance Rejected due to high
rate |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
11 Aug 2025, 12:00 pmClosed
Executive Engineer Electrical DIV I HD
New Secretariat Building B Block Room No1 Ground Floor 1 KS Roy Road Kolkata 700001
Renovation and Repairing work of compound lighting system at Regent Estate Govt. Housing RHE Govt. Housing under South Kolkata Electrical Section - II, H.Dte.
2025_HSD_885429_1
WBHD/EE/ED-1/eNIT-100/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Regent Estate Govt Housing
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
29 Oct 2025
31 Jul 2025
13 Aug 2025
31 Jul 2025
11 Aug 2025
31 Jul 2025
Amount
Supplying and fixing 2 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. along with Supplying and fixing 240V 32A DP MCB (Make: Legrand/Schneider/Siemens/ABB/L&T) of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole One coat of red lead/Zinc chromate priming. 1st coat of synthetic enamel paint over the primer. 2nd coat of synthetic enamel paint over the 1st coat.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
Supply and Delivery of 45 Watt (Efficacy not less than 120 LPW with IP 66 protection, 10 KV SPD included) street light fitting in place of the existing fitting including taking down the defunt street light. (Make: Crompton CRP-409-45-57-SL_GL-NSG or its equivalent of Philips/Wipro/Jaquar) with NABL accredited lab with valid test certificate, Driver Rating should be more thsn Fitting Rating.
Fixing only outdoor light Fitting by providing labour of different rated LED street light fitting as per the direction EIC.
Supply of 2 core 6 sqmm of 1.1 KV grade alluminium XLPE, PVC/ armoured LT cable ( Make : Havells/ Polycab/ Gloster/ Finolex/RR )
Laying of 2 core 6 sqmm cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish at an average depth of 75 mm in floor/pavement/wall etc.
Laying of one No. 2 core 6 sqmm cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of 2 core 6 sqmm cable.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :2 core 6 sqmm cable.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm).
Supplying and Laying 19mm heavy gauge Polythene Pipe. ( Loop Box to Fitting)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 32 mm dia
Hiring charges for mobile folding ladder at different sites for the above compound light work including transporation charges and providing 2 nos of unskilled labour for proper handing of the ladder and carring it
Add. G.S.T.@ 18% (on Total from item no 1 to 17) to be calculated by bidder
Add. LWC.@ 1% to be calculated (on total from item no 1 to 17 + GST@18%) by bidder
ANNAPURNA ELECTRICALS (BID ID -6813342)
MONDAL ENTERPRISE (BID ID -6797226)
M/S. GOPAL ELECTRICALS (BID ID -6807486)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .