Loading…
Loading…
Tender Value
₹2.7 Cr
EMD Value
₹2.9 L
Closing Date
27 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of SGCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing.
Defination of Similar Work :- Any indoor or combined indoor & outdoor work including, Supply, and/or Installation, Testing & commissioning of BPAC/DAC system for passenger carrying lines. OR Signalling work including Supply, Installation testing and commissioning of RRI/PI/EI systems for passenger carrying lines.
8 conditions · 6 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The bid must comply technical conditions of tender.
Provision of BPAC & Double Distant signal in Manmad - Ankai section on Bhusawal division.
BSL-N-SNT-37-2025-26
BSL-N-SNT-37-2025-26
Open
Works - General
9 Months
Jalgaon, Maharashtra
₹0
₹2.9 L
27 Feb 2026
3 Feb 2026
264 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,87,38,541.2 | ||
| — | 2.00 | — | — | ||
| Modification in existing EI system as per latest TAN, it includes :- Design and modification in existing interface and interlocking circuit of EI system, including modification in VDU,CCIP, MT, Data logger, EI, Relay rack complete wiring conforming to RDSO specification, as per technical requirement & tentative approved signalling plan/diagrams. Required hardware will be provided by railways except the wiring, material (i.e. connectors, interconnecting cable/wires,fuses etc.). The work includes supply of modified ST/LT,interface and logic circuit, CCIP/VDU diagram etc. to suit the approved interlocking plan. It also includes modification in data logger/MT, carrying out FAT, SAT jointly with railways and satisfactory commissioning of the modified EI with full complements as per approved IP and central railway practices. All plans and wiring diagrams shall be prepared on AUTOCAD and supplied in both soft copy and hard copies (6 sets). i) Alteration involving modification in upto 10 routes (Inspection by RDSO) | — | — | — | 30,67,968.49 | |
| — | 2.00 | — | — | ||
| Supply of Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C. Rly. Typical part list and Rack arrangement as per Sketch no SK- 727 and Rack plan as approved by Engineer incharge. (Inspection by Consignee) | — | — | — | 63,111.2 | |
| — | 8.00 | — | — | ||
| Supply of Tag Blocks 200 / 160/120 way with polycarbonate cover as per IRS S 77- 2006 (Rev 1 ) RDSO DRG. NO SA 24751, SA 24752 & SA 24753 Requirement of each type shall be specified by Engineer incharge .(Inspection by RDSO) | — | — | — | 10,118.09 | |
| — | 1.00 | — | — | ||
| Supply of Main Cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice on Central Railway. Typical part list and rack arrangement shall be as per sketch No. SK-727 with latest alterations. (Inspection by RITES) | — | — | — | 27,178.14 | |
| — | 2.00 | — | — | ||
| Supply of PVC Indoor Cable 1x60x0.6mm dia colour coding of insulation of inner core shall be in six colour Viz Blue , Red , Grey ,Green, Brown and Black conforming to IRS 76/89(Amdt 3) or latest. (Inspection by RDSO)) | — | — | — | 5,37,548.21 | |
| — | 2.00 | — | — | ||
| Supply of PVC Indoor Cable 1x 40x0.6mm dia. Colour coding of insulation of inner core shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & white. conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by RDSO) | — | — | — | 3,52,644.27 | |
| — | 2.00 | — | — | ||
| Supply of PVC indoor cable 1 x 24 x 1 mm dia. Colour coding of insulation of inner Conductor shall be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by RDSO) | — | — | — | 5,23,177.82 | |
| — | 5.00 | — | — | ||
| Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia. conforming to IRS 76/89 (Amdt 3) or latest.(Inspection by Consignee) | — | — | — | 38,650.94 | |
| — | 2.00 | — | — | ||
| Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee) | — | — | — | 23,408.63 | |
| — | 2.00 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x2.5 sq mm(50 conductor each dia 0.25 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3). (Inspection by RDSO) | — | — | — | 79,692.35 | |
| — | 2.00 | — | — | ||
| Supply of PVC Flexible Copper Cable, Single core, multi strand 1x10 sq mm(80 conductor each dia 0.40 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 1.00 mm nominal conductor resistance 1.91 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3). (Inspection by RDSO) | — | — | — | 2,52,185.82 | |
| — | 3.00 | — | — | ||
| Supply of wire 16/0.2(blue,red,gray,yellow,brown,black,white as per site engineer instruction)finolex/polycab/delton make.IRS:S-76/89(Amd.3),BS:4808 Part-2.Wire to be procured from RDSO approved vendor (Inspection by Consignee) | — | — | — | 17,284.01 | |
| — | 6.00 | — | — | ||
| Supply of Transformer 230V/110V-130V Single Phase 1 KVA as per spec. IRS S-72/88 (Amd.2) with latest amendments. (Inspection by RDSO) | — | — | — | 47,098.38 | |
| — | 5.00 | — | — | ||
| Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 24V DC, 30A as per spec. IRS.S.86/2000 (Amd.1) with latest amendments for Axle counter applications (Amd.4). (Inspection by RDSO) | — | — | — | 2,66,915.86 | |
| — | 6.00 | — | — | ||
| Supply of 63 A rating, 4 pole changeover switch disconnector with dual shaft position & staggered terminals with sheet steel enclosure and extended handle of Siemens/ L&T/ HAVELLS/ LEGRAND make. (Inspection by Consignee) | — | — | — | 40,786.73 | |
| — | 30.00 | — | — | ||
| "Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (Non AC Immunised) Siemens make (No. RSSK 30/0011) (Ref. IRS:S46/74 with Amd. 1 & firms specification.).or functional equivalent without base plates. Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge." (Inspection by RDSO) | — | — | — | 1,91,554.37 | |
| — | 6.00 | — | — | ||
| "Supply of Metal -To-Metal universal LED type ECR Siemens make (type A-RT-RG- A064) or functional equivalent without base plate, should be suitable for working with LED based signal lighting unit. IRS:S:46 & STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amd. 1". (Inspection by RDSO) | — | — | — | 37,131.41 | |
| — | 19.00 | — | — | ||
| Supply of QNA1 AC immunized relay 8F-8B,24VDC along with plug board, retaining clip and connectors conforming to BRS:931A,IRS:S60,IRS:S34 & IRS:S23 . (Inspection by RDSO) | — | — | — | 65,428.7 | |
| — | 18.00 | — | — | ||
| "Supply of Universal LED Lamp proving relay QECX61 relay, 4F-4B,AC conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.-1 (FOR ALL ASPECT ECR FOR AC LED SIGNAL) (Inspection by RDSO)" | — | — | — | 59,920.55 | |
| — | 18.00 | — | — | ||
| Supply of QNA1K relay 1000 ohm,6F/6B 24V DC as per BRS :931A, IRS:S60, IRS:S34 & IRS:S23 and RDSO spec. STS/ E/ Relays/UEA (PI) dtd.30.05.1997 (Inspection by RDSO) | — | — | — | 66,741.18 | |
| — | 20.00 | — | — | ||
| Supply of Domino units with cover plate as per approved panel diagram, each of size 54 x 34mm completely wired up similar to Siemens make. Each domino units should have all the 15 contact terminals wired up.(Inspection by Consignee) | — | — | — | 28,954.14 | |
| — | 50.00 | — | — | ||
| Supply of Panel Indication bulbs (Double LED type ) working voltage 24V- Colour- Red/Yellow/Green.(Inspection by Consignee) | — | — | — | 1,996.97 | |
| — | 3.00 | — | — | ||
| Supply of Automatic media changeover of Modems working on redundant channels for data transmission on OFC/Quad/Microwave Radio.(Inspection by Consignee) | — | — | — | 87,224.97 | |
| — | 6.00 | — | — | ||
| Supply of Modems for UFSBI (For use with secondary media and OFC/Quad.) (Inspection by Consignee)) | — | — | — | 3,48,761.68 | |
| — | 1.00 | — | — | ||
| Supply of Block proving by Digital Axle Counter as per RDSO/SPN/188/ 2004 with latest amendments using UFSBI for Single line BPAC working , RDSO SPN RDSO/S-32016 or latest complete as per RDSO spec. IRS S: 105/2012 ( Ver. 0) or latest . One pair consists of following : Universal Fail safe Block interface as per RDSO Spec. No. RDSO/SPN/147/2005 (latest amendments)- 02 Nos. SM's Panel (RDSO/S/32019 latest amendment) with all accessories complete- 02 Nos. Relay rack with due Locking and sealing arrangement duly wired (As per RDSO/S/32020 -including relays) - 02 Nos. Relays for double line section will be supplied with prewired relay rack.(Inspection by RDSO) | — | — | — | 8,49,660.8 | |
| — | 110.00 | — | — | ||
| "Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" A) "With holder 1.6 A (System, Rapid or Mainad Make)." (Inspection by Consignee) | — | — | — | 7,858.45 | |
| — | 50.00 | — | — | ||
| "Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" B) With holder 0.6 A (System, Rapid or Malnad Make) (Inspection by Consignee) | — | — | — | 3,450.01 | |
| — | 140.00 | — | — | ||
| "Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" C) Without holder 1.6 A (System, Rapid or Malnad Make). (Inspection by Consignee) | — | — | — | 2,880.86 | |
| — | 50.00 | — | — | ||
| "Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" E) Without holder 0.6 A (System, Rapid or Malnad Make).(Inspection by Consignee) | — | — | — | 1,028.88 | |
| — | 80.00 | — | — | ||
| Supply of PPTC Fuse GP 250-185UL-94 Certifcaion (24V/4A)TPR .Make:LITTLEFUSE,FUZETEC,TYCO,BOURN,RAYCHEM etc(Inspection by Consignee) | — | — | — | 612.14 | |
| — | 3.00 | — | — | ||
| Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection by Consignee) | — | — | — | 3,359.04 | |
| — | 5.00 | — | — | ||
| Lacing thread rolls, black, wax coated (100 mtrs) (Inspection by Consignee) | — | — | — | 295.66 | |
| — | 3.00 | — | — | ||
| Design,fabrication and supply of fuse Auto changeover system for 32 Nos of external non detorating Type fuses of G type fuses from 0.6 A Amp to 4A Amp capacities used in signalling circuits.System shall have 8 cards with monitoring arrangement of 4 fuses in one card.As per RDSO spec.RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (NO. OF MODULES=NUMBER) (Inspection by CONSIGNEE) | — | — | — | 71,762.91 | |
| — | 10.00 | — | — | ||
| Supply of Main Signal Post 140 mm outer dia 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection by CONSIGNEE) | — | — | — | 82,537.36 | |
| — | 10.00 | — | — | ||
| Supply of Cast Iron Main signal surface base140 mm as per spec No IRS S-10 and Drg No 2011/M with latest amendments, with CLS ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per R. No SA-23156(Adv),SA 23153(Adv) & SA 23150 (Adv) Alt. 1 respectively with latest Amendment as the case may be for CLS unit & signal back staging as per extant C.Rly practice . (Inspection by CONSIGNEE) | — | — | — | 80,756 | |
| — | 10.00 | — | — | ||
| Supply of Signal No. plates. as per Drg No RST-11393/SK 842 (Inspection by Consignee) | — | — | — | 4,663.39 | |
| — | 3.00 | — | — | ||
| OFF set bracket 5-1/2 " to suit 140 mm dia CLS post with two nos. of "U" Bolts with nuts and washer complete as per RDSO Drg No SA-23080 for Signals & Routes (Inspection by Consignee) | — | — | — | 2,681 | |
| — | 6.00 | — | — | ||
| Supply of A/AG/C/P/G/IB Board as per Drg RST-11444/1(A), RDSO Drg No SA 23460(AG), SA 23461( C) , RST-11445 , SA 23456(P), SA 23477(G) & SA 234476-77(IB) as applicable respectively with latest Amendment. (Inspection by Consignee) | — | — | — | 3,012.84 | |
| — | 6.00 | — | — | ||
| Supply of Stop Board/IB Board as per RST-11791 (STOP BOARD)/ RDSO Drg No.7235/B as per extent C.Rly practice. (Inspection by Consignee) | — | — | — | 17,914.35 | |
| — | 18.00 | — | — | ||
| Supply of Hand Cuff Locks/ Godrej Navtal lock with three common key (Inspection by Consignee) | — | — | — | 4,605.02 | |
| — | 10.00 | — | — | ||
| Supply of 3 aspect signal unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev 2.0 or latest complete to suit LED signals lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside . White pigment finish inside the 4 aspect unit to avoid any extra paint cost. (Inspection by CONSIGNEE) | — | — | — | 2,83,446.66 | |
| — | 24.00 | — | — | ||
| Supply of FIBRE GLASS INSULATING FIRE RETARDENT SHEET of 10 mm THICKNESS AS PER ISO:10192-1982,Dielectric strength -25KV/mm with glass content 25 to 34%, in standard size of 1.10x1.10Mtr.as per spec.No.IS:10192-1982 (Inspection by RITES) | — | — | — | 1,13,704.08 | |
| — | 2200.00 | — | — | ||
| Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt -4 & SA-23756 Alt-3. (Inspection by RDSO) | — | — | — | 1,42,793.37 | |
| — | 86.00 | — | — | ||
| Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses.(Inspection by RDSO) | — | — | — | 12,526.08 | |
| — | 86.00 | — | — | ||
| Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity(Inspection by RDSO) | — | — | — | 5,391.27 | |
| — | 43.00 | — | — | ||
| Supply of Tik-tak, piano type switches,5 A (As per IS specification).(Inspection by Consignee) | — | — | — | 1,284.2 | |
| — | 43.00 | — | — | ||
| Supply of three pole plug and socket 5 Amp(As per IS specification). (Inspection by Consignee) | — | — | — | 8,873.73 | |
| — | 43.00 | — | — | ||
| Supply of Lamp 110V/24W,2 Pin for Loc. (Inspection by Consignee) | — | — | — | 873.69 | |
| — | 31.00 | — | — | ||
| Supply of Apparatus Case with godown locks with deatachable handle on both the doors. i) Single Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES) | — | — | — | 4,43,930 | |
| — | 14.00 | — | — | ||
| Supply of Apparatus Case with godown locks with deatachable handle on both the doors. ii) Half Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES) | — | — | — | 1,60,861.92 | |
| — | 43.00 | — | — | ||
| Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection by Consignee) | — | — | — | 41,438.92 | |
| — | 23.00 | — | — | ||
| Maintenance Free Earth As per RDSO/SPN/197/2008 or latest consisting of :1) Copper bond steel electrode 3 Mtr long 17 mm dia with copper bonding thickness of min.250 micron & UL listed & marked -01 No 2) Earth enhancement compound RDSO Approved in sealed bag of 10Kgs-03 No 3) Copper strip 150x25x6 mm -02 No 4) Copper strip 300x25x6 mm -01 No 5)35 Sqmm Copper Cable to connect earth electrod to MEEB-15 Mtr Approx. (Inspection by RDSO) | — | — | — | 3,65,681.61 | |
| — | 10.00 | — | — | ||
| "Supply of Single Section Digital Axle Counter (SSDAC) with two detection point with reset arrangement and vital relay box as per RDSO/SPN/177/2012 Ver.03 or Latest. Each set consist of following:- a)High frequency TX coil and RX coil (Each set consist of web mounting type TX coils-2 Nos. RX coils-2 Nos along with 10 mtr cable-2 sets) , b)Track side digital axle counter unit-2 nos c) 24V 6F/4B, 1000 ohm ""Q"" type relay Box duly wired -2Nos. d)Clamp with deflector plates and hardware etc-4nos , e)Reset Box 2Nos ii)Mushroom/Location Box suitable for housing Track side equipment (2 Nos) 2) Transportation, Installation testing & commissioning:- Transportation, Installation testing & commissioning of equipment field training (one man day per set) at site or as desired by site Engineer. These includes: - a) Foundation & erection of Track side Equipment i.e. Mushroom/ Location Box (If required). This includes supply of all associated materials., -b) No. Individual Earthing of all detection Point for the OEM recommended earth value certified by OEM site engineer. This includes supply & installation of maintenance free earth materials and exothermic bonding and other connecting cable etc as per Railway practice (As per RDSO Spec. no: RDSO/SPN/197/2008 or latest. Resetting equipment to be connected to the EI Ring earth. c) Installation to be carried out by OEM certified Engineer.3) Tool Kit consisting of:- a) Digital True RMS multi meter of suitable make for above Digital Axle counter system with probe set- 1no b) Train Simulator(High frequency)-1 no c) Extender Card-1no d) Dummy wheel-1no e) Different type of spanners suitable for above Digital Axle counter- 1set f) Torque wrenches suitable for the above-1 no g) Screw driver set suitable for the above- 1Set h) Carrying Bag for Tools-1No. i) 6 nos. Electrostatic Discharge Wrist Band for cards/ modules protection." (Inspection by RDSO) | — | — | — | 39,38,782.45 | |
| — | 5.00 | — | — | ||
| Supply of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2 NO/2NC contact working voltage 24V/60V DC siemens/ABB/L&T or SELEC(642xA programmable electronic timer switch)make (Inspection by CONSIGNEE) | — | — | — | 12,600.77 | |
| — | 885.00 | — | — | ||
| Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings.TATA/ JINDAL/ ZENITH BIRLA Make. (Inspection by RITES) | — | — | — | 8,14,296.6 | |
| — | 847.00 | — | — | ||
| Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO /SPN /204/2011/Ver 1.1 with Amdt 1 or latest. (Inspection by RITES) | — | — | — | 2,43,365.36 | |
| — | 23050.00 | — | — | ||
| Supply of RCC pipe half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection by RITES) | — | — | — | 42,47,389.99 | |
| — | 165.00 | — | — | ||
| Supply of "C" Channel Clamps with nut bolts, washers and all type fixtures for 6 inch dia pipe to be fixed on GIRDERS, on rock cuttings etc., as per DRG No.SK-900. (Inspection by CONSIGNEE) | — | — | — | 3,33,145.04 | |
| — | 1050.00 | — | — | ||
| Supply of Modular Terminal block of 2.5 sqmm 2 IN 2 out type disconnect type terminal along with as per RDSO Specn.No.RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps & more,The terminal should have marking at centre to view description from front.Material to be procured from RDSO approved firm only. (Inspection by RDSO) | — | — | — | 1,09,928.25 | |
| — | 14.00 | — | — | ||
| Supply of DIN channel for the terminals 1 Mtr each (Inspection by Consignee) | — | — | — | 2,712.29 | |
| — | 70.00 | — | — | ||
| Supply of End plates for modular terminal block (Inspection by Consignee) | — | — | — | 1,463.58 | |
| — | 70.00 | — | — | ||
| Supply of End clamp for modular terminal block (Inspection by Consignee) | — | — | — | 1,051.85 | |
| — | 14.00 | — | — | ||
| Supply of marker card as per customer spec(10x10) (Inspection by Consignee) | — | — | — | 1,048.85 | |
| — | 3.00 | — | — | ||
| "Operating tool (operating tool, screw driver & stripper) as per Annexure-VII," (Inspection by Consignee) | — | — | — | 23,224.06 | |
| — | 21.00 | — | — | ||
| Supply of thermo shrink Jointing kit (Reinforced) TSF-2 type generally conforming to R D S O Specification No.RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE Specification No.CR/SPN/TC/57 (A)/2015 dtd 06.01.2015(Table -A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables along with sub-kit(Table-B) for armour continuity. (Inspection by RDSO) | — | — | — | 56,164.96 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_2022__POLICY_27_04_22.pdf
GCC-April2022_merged20.05.2024.pdf
C.RLYDRAWINGANNEXURES-SORST-20211_compressed.pdf
InspectionofSafety-CriticalSignalingItemsbyRDSORSDte26.09.2025.1.pdf
TenderBooklet37-25-26.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .