Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC Being lowest. | |
| 2 | L2₹41.3 L+₹4.3 L (11.7%)Rejected-AOC NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-AOC Being other than lowest. | |
| 3 | L3₹4.2 Cr+₹3.8 Cr (1035.0%)Rejected-AOC | L3 | Rejected-AOC Being other than lowest. | |
| 4 | L4₹44.6 L+₹7.6 L (20.5%)Rejected-AOC 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L4 | Rejected-AOC Being other than lowest. | |
| 5 | Rejected-Technical MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND PIN 744301 | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | - | Rejected-Technical Not enlist in requisite cat c(i). |
| Sl No | Description | Qty | Unit | Tropical Refrigeration L1 | M/s Karbhagam Sales Agency L3 | surendra infrastructure pvt ltd L4 | RK TRADERS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old ACs Package type of any capacity from site and transporting to AGE E/M store yard for depositing.
Note: (i) Rate including disconnecting all electrical cbles, makng shutdown and all kind of peventive measures deemed to be incuded in quoted rate.
(ii) Suitable veh for conveyance of taken down assets from the site upto AGE E/M salvage store shall deemed to be included in quoted rate.
(iii) Skilled manpower for dismountig and taking down shall be deployed by the contractor at site. | 3 | Each | 6,000 ₹18,000 Lowest | 7,800 ₹23,400 | 9,200 ₹27,600 | 7,200 ₹21,600 |
| 2.00 | Supply, installation, testing and commissioning of Split type Air Conditioner of Capacity 1.5 TR, 5 Star rating, Inverter type,Indoor unit with copper coiling coil and outdoor unit with copper tube condenser coil complete with cordless remote control, filled with the latest environment friendly refrigerant R-32 fitted with highly energy efficient rotary compressor of copper wound, including PVC FRLS grade multistranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, Copper connection pipes with insulation, GI brackets/stand for outdoor unit, clamps, nuts, bolts, washers, drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with PCC, white cement and painting work to match with the existing surface of wall complete all as specified and directed.
Make- Bluestar Model No-IC518DNU or equivalent in Voltas/ LG/ Daiken/ Hitachi.
Notes: -
(a) Installation work to be carried out by (OEM or Authorised dealer).
(b) Copper connection pipes with insulation exceeding 3 Mtrs and PVC drain pipes shall be measured and paid separately.
(c) Compressor Warranty 5 years. | 11 | Each | 79,000 ₹8,69,000 Lowest | 86,500 ₹9,51,500 | 92,500 ₹10,17,500 | 83,500 ₹9,18,500 |
| 3.00 | Supply, installation, testing and commissioning of window type Air Conditioner of Capacity 2.0 TR min BEE, 3 Star rating,non Inverter type which uses the latest environmental friendly refrigerant R-32/R-410A fitted with highly energy efficient rotary compressor,making necessary arrangements like cutting grills, for fixing on window and making good the disturbed surfaces, covering the exposed part of window with veneerplywood where ever required complete including Taking down old ACs window/Split type of any capacity from site and transporting to AGE E/M store yard for depositing, complete all specified and directed.
Make- Bluestar / Voltas/ LG/ Daiken/ Hitachi.
Note: (i) Rate including disconnecting all electrical cbles, makng shutdown and all kind of peventive measures deemed to be incuded in quoted rate.
(ii) Suitable veh for conveyance of taken down assets from the site upto AGE E/M salvage store shall deemed to be included in quoted rate.
(iii) Skilled manpower for dismountig and taking down shall be deployed by the contractor at site. | 3 | Each | 90,000 ₹2,70,000 Lowest | 98,200 ₹2,94,600 | 1,08,000 ₹3,24,000 | 95,600 ₹2,86,800 |
| 4.00 | Supply, installation,commisioning & testing package type air conditioner of capacity 5.5TR, BEE 3 Star, three phase, voltage range(360-415) Volts AC supply with hermetically sealed scroll compressors,refrigerant type R-22/R-32/R-410A/R-404 including initial charging of refrigerant , consisting intelligent microprocessor controller with LCD display, propeller fan type condensor with air cooled fin and tube heat exchanger, non-woven polyester media enclosed by HDPE mesh air filter, centrifugal forward curved, double inlet, double width type blower, low noise and corrossion resistant body, including powder coated angle angle iron stand for outdoor unit complete all as specified and directed. | 3 | Each | 4,00,000 ₹12,00,000 Lowest | 4,52,000 ₹13,56,000 | 5,12,000 ₹15,36,000 | 4,62,500 ₹13,87,500 |
| 5.00 | Supply,testing and commissioning water cooler electrically driven, stainless steel body, IEE raiting 3.5 min single phase with inbuilt purifier HIMA 7 NHC , dispencing capacity 125 Ltrs/hr and storage tank capacity 40 Ltrs normal, 40 Ltrs Cold, single phase 230 V AC power supply with all connecting accessories complete all as specified and as directed.
Make: Best water cooler HIMA 7NHC ABS of Crossfields or equivalent in Voltas/Blue star/Godrej/Usha | 9 | Each | 1,25,000 ₹11,25,000 Lowest | 1,36,500 ₹12,28,500 | 1,36,200 ₹12,25,800 | 1,35,000 ₹12,15,000 |
| 6.00 | Material and labour for Sub main wiring using two runs of single core PVC insulated cable (FRLS) 4 sqmm copper conductor multi stranded and one run of 4 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size rigid non-metallic PVC conduit including taking down old aluminium/Copper Sub main wirng, complete all as specified and directed.
Note- 3 run of 4 sq mm PVC copper wire and One run of PVC conduit shall be measured and paid as one unit. | 24 | Running Metre | 700 ₹16,800 Lowest | 850 ₹20,400 | 956 ₹22,944 | 850 ₹20,400 |
| 7.00 | Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with and including one MCB single pole 20 Amps complete all as specified and directed. | 14 | Each | 1,550 ₹21,700 Lowest | 1,650 ₹23,100 | 1,850 ₹25,900 | 1,750 ₹24,500 |
| 8.00 | Supply and fixing 20 mm bore Low density polyethylene (LDPE) drain pipe of pressure rating 6 kgf/sqcm for Split AC complete all as specified and directed. | 15 | Running Metre | 600 ₹9,000 Lowest | 853 ₹12,795 | 865 ₹12,975 | 825 ₹12,375 |
| 9.00 | Supply, assemble and erection of ducting, made of GI sheets of 1mm (18 gauge) thickness as in Air Condition Ducting including fabrication for required size, patch work, fixing on walls, roofs and ceiling or in existing iron frame work including all accessories such as Corner, cleat, Carriage bolt, Gasket lap joint, welding, reverting and appropriate sealent on longitudnal joints etc complete in repairs all as specified and as directed by Engr-in-Charge. | 42.5 | Square meter | 2,100 ₹89,250 Lowest | 2,890 ₹1,22,825 | 2,850 ₹1,21,125 | 2,650 ₹1,12,625 |
| 10.00 | Material and Labour for thermal insulation of ducts with 13mm nitrile rubber with aluminium foil face complete all as specified and directed by Engr-in-Charge all as specified and directed | 42.5 | Square meter | 2,200 ₹93,500 Lowest | 4,200 ₹1,78,500 | 3,650 ₹1,55,125 | 3,450 ₹1,46,625 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Dec 2025, 6:00 pmClosed
GE (I) 866 EWS CARNICOBAR
GE(I)866 EWS CARNICOBAR PIN-913866 C/O 99APO
SPECIAL REPAIR REPLACEMENT OF BER SUMMER APPLIANCES WITH CONNECTED WORKS FOR FY 2021 22 AT AIR FORCE STATION CARNICOBAR
2025_MES_740559_1
8778/E8
Open Tender
Civil Works
Item Rate
365 days
GE (I) 866 EWS CARNICOBAR AIR FORCE STATION
AS per tender documents
9 documents required · 9 mandatory
₹500
GE (I) 866 EWS
₹80,000
Yes
5 Feb 2026
19 Nov 2025
17 Dec 2025
19 Nov 2025
10 Dec 2025
3 Dec 2025
Taking down old ACs Package type of any capacity from site and transporting to AGE E/M store yard for depositing. Note: (i) Rate including disconnecting all electrical cbles, makng shutdown and all kind of peventive measures deemed to be incuded in quoted rate. (ii) Suitable veh for conveyance of taken down assets from the site upto AGE E/M salvage store shall deemed to be included in quoted rate. (iii) Skilled manpower for dismountig and taking down shall be deployed by the contractor at site.
Supply, installation, testing and commissioning of Split type Air Conditioner of Capacity 1.5 TR, 5 Star rating, Inverter type,Indoor unit with copper coiling coil and outdoor unit with copper tube condenser coil complete with cordless remote control, filled with the latest environment friendly refrigerant R-32 fitted with highly energy efficient rotary compressor of copper wound, including PVC FRLS grade multistranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, Copper connection pipes with insulation, GI brackets/stand for outdoor unit, clamps, nuts, bolts, washers, drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with PCC, white cement and painting work to match with the existing surface of wall complete all as specified and directed. Make- Bluestar Model No-IC518DNU or equivalent in Voltas/ LG/ Daiken/ Hitachi. Notes: - (a) Installation work to be carried out by (OEM or Authorised dealer). (b) Copper connection pipes with insulation exceeding 3 Mtrs and PVC drain pipes shall be measured and paid separately. (c) Compressor Warranty 5 years.
Supply, installation, testing and commissioning of window type Air Conditioner of Capacity 2.0 TR min BEE, 3 Star rating,non Inverter type which uses the latest environmental friendly refrigerant R-32/R-410A fitted with highly energy efficient rotary compressor,making necessary arrangements like cutting grills, for fixing on window and making good the disturbed surfaces, covering the exposed part of window with veneerplywood where ever required complete including Taking down old ACs window/Split type of any capacity from site and transporting to AGE E/M store yard for depositing, complete all specified and directed. Make- Bluestar / Voltas/ LG/ Daiken/ Hitachi. Note: (i) Rate including disconnecting all electrical cbles, makng shutdown and all kind of peventive measures deemed to be incuded in quoted rate. (ii) Suitable veh for conveyance of taken down assets from the site upto AGE E/M salvage store shall deemed to be included in quoted rate. (iii) Skilled manpower for dismountig and taking down shall be deployed by the contractor at site.
Supply, installation,commisioning & testing package type air conditioner of capacity 5.5TR, BEE 3 Star, three phase, voltage range(360-415) Volts AC supply with hermetically sealed scroll compressors,refrigerant type R-22/R-32/R-410A/R-404 including initial charging of refrigerant , consisting intelligent microprocessor controller with LCD display, propeller fan type condensor with air cooled fin and tube heat exchanger, non-woven polyester media enclosed by HDPE mesh air filter, centrifugal forward curved, double inlet, double width type blower, low noise and corrossion resistant body, including powder coated angle angle iron stand for outdoor unit complete all as specified and directed.
Supply,testing and commissioning water cooler electrically driven, stainless steel body, IEE raiting 3.5 min single phase with inbuilt purifier HIMA 7 NHC , dispencing capacity 125 Ltrs/hr and storage tank capacity 40 Ltrs normal, 40 Ltrs Cold, single phase 230 V AC power supply with all connecting accessories complete all as specified and as directed. Make: Best water cooler HIMA 7NHC ABS of Crossfields or equivalent in Voltas/Blue star/Godrej/Usha
Material and labour for Sub main wiring using two runs of single core PVC insulated cable (FRLS) 4 sqmm copper conductor multi stranded and one run of 4 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size rigid non-metallic PVC conduit including taking down old aluminium/Copper Sub main wirng, complete all as specified and directed. Note- 3 run of 4 sq mm PVC copper wire and One run of PVC conduit shall be measured and paid as one unit.
Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with and including one MCB single pole 20 Amps complete all as specified and directed.
Supply and fixing 20 mm bore Low density polyethylene (LDPE) drain pipe of pressure rating 6 kgf/sqcm for Split AC complete all as specified and directed.
Supply, assemble and erection of ducting, made of GI sheets of 1mm (18 gauge) thickness as in Air Condition Ducting including fabrication for required size, patch work, fixing on walls, roofs and ceiling or in existing iron frame work including all accessories such as Corner, cleat, Carriage bolt, Gasket lap joint, welding, reverting and appropriate sealent on longitudnal joints etc complete in repairs all as specified and as directed by Engr-in-Charge.
Material and Labour for thermal insulation of ducts with 13mm nitrile rubber with aluminium foil face complete all as specified and directed by Engr-in-Charge all as specified and directed
Schedule of Credit (Minus) Rs.12865.00 NOTE: Bidder shall insert credit amount of Rs. 12865.00 as rate in Green field under Col-13.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender8778.pdf
Tender Documents • 1.02 MB
BOQ_829256.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .