Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-Finance | ₹2.7 Cr | L1 | Accepted-Finance Lowest |
| 2 | L2₹3.0 Cr+₹32.9 L (12.2%)Rejected-Finance | ₹3.0 Cr+₹32.9 L (12.2%) | L2 | Rejected-Finance Second lowest |
| 3 | L3₹3.1 Cr+₹45.3 L (16.9%)Rejected-Finance | ₹3.1 Cr+₹45.3 L (16.9%) | L3 | Rejected-Finance Highest |
Tender Value
₹2.8 Cr
Closing Date
7 Jul 2021, 6:00 pmClosed
ACE III RHB
Additional Chief Engineer III Rajasthan Housing Board Jyoti Nagar Jaipur
Construction of water supply scheme for City Level Park Mansarovar Jaipur
2021_RHBCE_227678_5
ACE_III_02_2021_22
Open Tender
Civil Works
Percentage
180 days
Jaipur
As per NIT
3 documents required · 3 mandatory
₹3,540
As per NIT
Exempted
4 Jan 2024
17 Jun 2021
9 Jul 2021
17 Jun 2021
7 Jul 2021
17 Jun 2021
Amount
Provision for garden hydrant as per approved drawing and specification direction of Engineer-in-charge.
Providing & Fixing C.I. Ball Valve of following dia (IS:Make) of approved make, superior quality including all fittings, jointing material, labour, complete as per Technical Specifications and as per direction of Engineer - in charge. 75 mm dia
Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade & PN-6 for potable water as per IS 4984 (amended upto date) in trenches complete with all accessories like Bend, Tee, Reducer, Stub end, End cap etc including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately
75 mm dia
110 mm dia
125mm dia
160 mm dia
Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932 (Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 100 mm dia Class PN 1.0
Providing and fixing of reinforced Ferro-Cement drain covers designed for 'A' class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate, Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc. Standard Size 1500x600mm (125mm thick) for span 701 to 1200mm
Construction of RCC Clear Water Reservoirs of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab and food grade epoxy paint to inner face of the container and slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar, ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints on all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.
Notes
The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete.
Below mentioned rates are for raft foundations with soil bearing capacity (SBC) of 10 MT/sqm and applicable for SBC more than or equal to 10MT/sqm and less than 18MT/sqm. These rates shall be increased or decreased for variation in SBC as below:
For foundation on SBC 7 MT/sqm applicable for SBC more than or equal to 7 MT/sqm and less than 10 MT/sqm, add 5%
For foundation on SBC more than 5 MT/sqm and up to 7 MT/sqm, add 7.5%.
For foundation on SBC more than 18MT/sqm rates decreased by 5 %
Following rates are for seismic zone II. For zone III, these rates shall be increased by 4% and for zone IV, these rates shall be increased by 9%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones.
Rates for RCC Rectangular Flat Slab CWR, SBC 10T/sqm, seismic zone II .
up to100 KL capacity
Water Tank-1 (75 KL - 2 Nos)
Water Tank-2 (75 KL - 2 Nos)
up to150 KL capacity
Water Tank-3 (115 KL - 2 Nos)
Water Tank-4 (115 KL - 2 Nos)
Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect. Pum House-1 (10.0 m x 8.0 m x 3.3 m) Pum House-2 (10.0 m x 8.0 m x 3.3 m) Pum House-3 (4.5 m x 9.8 m x 3.3 m) Pum House-4 (4.5 m x 9.8 m x 3.3 m)
Provision for O&M of TWs, Rising Main, Reclaimed (STP treated) water supply pipelines, raw water supply pipelines, fresh water supply pipelines. Maintanance Team for M&R of Pipe line network DI / HDPE Pipe including 7 Nos. tube well for repair and maintenance complete job
Bidder Name
Amount
M/s anil kumar gupta(GSTN-08ABOPG2014M1ZM)
sharvan singh construction co(GSTN-08AFEPB1571J1ZN)
M/S Jagdish Prasad Agarwal(GSTN-NA)
M/S Jagdish Prasad Agarwal
M/s anil kumar gupta
M/S Jagdish Prasad Agarwal
M/s anil kumar gupta
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .