Loading…
Loading…
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
23 Jun 2026, 11:00 am
MYS Augmentation of Mechanised Laundry from 3.5 Ton to 7 Ton / Day capacity.
Y-E-29-2026-27-27
Y-E-29-2026-27-27
Open
180 Days
Unknown (Unspecified Location)
₹0
₹2.0 L
2 Jun 2026
2 Jun 2026
9 Jun 2026
refilling the cable trench to original shape by excavated soil free from unwanted materials. NS 10.00 Metre 598.89 5988.90 AT Par 5988.90
terminations at both ends. This work includes Extension of power supply from the nearest power supply source in the excavated cable trench/in trough/on building walls/sheds/shelters etc. NS 100.00 Metre 130.00 13000.00 AT Par 13000.00
of 1.1 KV grade of above 35 sq. mm and up to 95 sq. mm (clamped with 40x3mm MS flat clamp) size on wall surface as required. NS 50.00 Metre 161.00 8050.00 AT Par 8050.00 Description:- Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable
in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. NS 150.00 Metre 226.00 33900.00 AT Par 33900.00
of 1.1 KV grade of Above 95 sq. mm and up to 185 sq. mm (clamped with 40x3mm MS flat clamp) size on wall surface as required. NS 200.00 Metre 213.00 42600.00 AT Par 42600.00 Description:- Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable
in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. MYSORE DIVISION-ELECTRICAL/SOUTH WESTERN RLY NS 50.00 Metre 226.00 11300.00 AT Par 11300.00
of 1.1 KV grade of above 185 sq. mm and up to 400 sq. mm (clamped with 40x3mm MS flat clamp) size on wall surface as required. NS 3.00 Set 111.00 333.00 AT Par 333.00 09 Description:- Brass compression gland suitable for 70 sq. mm 1.1 KV grade cable. NS 3.00 Set 213.75 641.25 AT Par 641.25 10 Description:- Brass compression gland Suitable for 150 sq. mm 1.1 KV grade cable. NS 3.00 Set 273.75 821.25 AT Par 821.25 11 Description:- Brass compression gland Suitable for 185 sq. mm 1.1 KV grade cable. NS 3.00 Set 551.25 1653.75 AT Par 1653.75 12 Description:- Brass compression gland Suitable for 400 sq. mm 1.1 KV grade cable. NS 30.00 Metre 759.41 22782.30 AT Par 22782.30
including clamping, fixing arrangements and sealing with bituminous compound. NS 100.00 Metre 421.71 42171.00 AT Par 42171.00
for safety of cables. NS 12.00 Set 5436.01 65232.12 AT Par 65232.12 Description:- L.T. Earthing arrangements for hard soil using 50 mm C-Class GI Pipe- 2.7 Mtr length,
paint and stencilling of earth resistance value with date, including supply and laying of 6 SWG G.I. wire and other hardware to connect equipment at site complete. NS 10.00 Numbers 2510.45 25104.50 AT Par 25104.50
similar to Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-
to Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-
NS 6.00 Numbers 9582.00 57492.00 AT Par 57492.00 Description:- Supply, fixing, connection and testing of air circulator wall mounting brackets fan
up at suitable height with foundation bolt and clamp asper requirement having suitable ratings MCB with steel enclosure for ON/OFF. NS 6.00 Numbers 3746.00 22476.00 AT Par 22476.00
Exhaust Fan suitable for fan size 300 mm etc. NS 4.00 Set 6143.00 24572.00 AT Par 24572.00
Circuits etc. Floor/Panel/Tower/Wall mounted, Supply Voltage 240 VAC, 50/60HZ, with DP 32A power contractor and 32A,10 kA DP MCB-01 no with SS enclosure with proper wiring. NS 12.00 Numbers 218.00 2616.00 AT Par 2616.00
LED lighting fixture as per specification SWR/LED LIGHT FITTING(Indoor/outdoor)/001-2016 effective from 18.04.2016 or latest. Including all other required accessories complete. NS 30.00 Numbers 178.24 5347.20 AT Par 5347.20
fixtures Including all other required accessories complete. NS 4.00 Numbers 1853.00 7412.00 AT Par 7412.00
mm x 170 mm with Hinged door with 0.5 AMCB and 32A strip connector. NS 4.00 Each 447.75 1791.00 AT Par 1791.00
surface or in recess, including providing and fixing 5 pin 5/6 A modular socket outlet and 5/6 A separate modular switch, connections etc. as required. NS 6.00 Each 550.07 3300.42 AT Par 3300.42 25 MYSORE DIVISION-ELECTRICAL/SOUTH WESTERN RLY Description:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 15/16 A modular socket outlet and 15/16 A separate modular switch, connections etc. as required. NS 30.00 Metre 144.00 4320.00 AT Par 4320.00 Description:- Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip
(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) NS 30.00 Metre 42.00 1260.00 AT Par 1260.00
along with existing surface/ recessed conduit/ submain wiring/ cable as required. NS 1.00 Set 10127.63 10127.63 AT Par 10127.63 Description:- Design, Supply, fixing and commissioning of 12 Way SPN Double Door Distribution
and outgoing SP MCB 6-32A 10 Ka - 10 No's with required suitable hardware and internal wiring complete. NS 2.00 Set 30553.74 61107.48 AT Par 61107.48 Description:- Design, Supply, fixing and commissioning of 12 Way TPN Double Door Distribution
and outgoing TP MCB 63 A - 2 No., SP MCB 6-32A - 16 No's along with TP+N SPD - 1 No. with required suitable hardware and internal wiring complete. NS 4.00 Numbers 255.00 1020.00 AT Par 1020.00
socket, and modular plate with support frame -1 No each on suitable PVC Box complete. NS 2.00 Numbers 382.00 764.00 AT Par 764.00
earth wire sizes of FRLSH PVC insulated copper conductor, single core cable in surface /concealed medium class PVC conduit/casing capping as required as per CPWD Standard. NS 200.00 Metre 243.12 48624.00 AT Par 48624.00
earth wire sizes of FRLSH PVC insulated copper conductor, single core cable in surface /concealed medium class PVC conduit as required as per CPWD Standard NS 250.00 Metre 199.94 49985.00 AT Par 49985.00
mm earth wire sizes of FRLSH PVC insulated copper conductor, single core cable in surface /concealed medium class PVC conduit as required as per CPWD Standard. NS 40.00 Point 739.69 29587.60 AT Par 29587.60 Description:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable etc. as required as per CPWD Standard. NS 2.00 Numbers 26827.60 53655.20 AT Par 53655.20
working on 415 V 50 Hz AC supply BEE 5-star rating with warranty similar to Make CELVIN Model STKOMT24. NS 2.00 Numbers 6388.00 12776.00 AT Par 12776.00
Toubro (Detailed Description /Specification as per Product # 1 of GeM Contract No. GEMC-
viewing MC along with suitable hardware and accessories complete. NS 2.00 Numbers 1816.00 3632.00 AT Par 3632.00
viewing MC along with suitable hardware and accessories complete. NS 2.00 Numbers 9315.00 18630.00 AT Par 18630.00 40 MYSORE DIVISION-ELECTRICAL/SOUTH WESTERN RLY 40 Description:- Supplying of multifunction digital meter with three-line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP54 degree of protection and completely wired as required with communication Port and Class 0.5 s accuracy with all other required accessories complete. NS 3.00 Numbers 562.00 1686.00 AT Par 1686.00
Class 0.5 accuracy with Tape Wound with all other required accessories complete. NS 1.00 Numbers 96472.00 96472.00 AT Par 96472.00 Description:- Design, fabrication, supply, erection, testing and commissioning of double door wall mounting concealed type power distribution board with locking arrangements, made of 16 SWG MS sheet steel enclosure, phosphate and painted with epoxy polyester-based powder paint, comprising of 3 phase, 4 wire, 415 volts, Cu bus bars of Suitable size & length, cable entry on top with the
Minimum size of DB is 1600x1700x400mm. with following switch gears :- Incoming:-400 Amps FP MCCB with Rotary Handle shunt trip - 1 No. (with adjustable thermal magnetic unit) Outgoing:-(a)
SP MCB -4 Nos, (e) (All C-Series) (f) Suitable capacity 3 phase and Neutral Bus Bar-1 set (g) Multi- functional meter with earth leakage Relay with CBCT 3 ph indicating lamp with back up fuse protection -01 set. (Main distribution panel-2). NS 500.00 Metre 963.00 481500.00 AT Par 481500.00 Description:- Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness size of
with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. NS 6.00 Numbers 1852.00 11112.00 AT Par 11112.00 Description:- Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness size of
with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () II-Service Buildings 351136.72 NS 100.00 Metre 313.52 31352.00 AT Par 31352.00
earth wire sizes of FRLSH PVC insulated copper conductor, single core cable in surface /concealed medium class PVC conduit/casing capping as required as per CPWD Standard. NS 200.00 Metre 243.12 48624.00 AT Par 48624.00
earth wire sizes of FRLSH PVC insulated copper conductor, single core cable in surface /concealed medium class PVC conduit as required as per CPWD Standard NS 250.00 Metre 199.94 49985.00 AT Par 49985.00
mm earth wire sizes of FRLSH PVC insulated copper conductor, single core cable in surface /concealed medium class PVC conduit as required as per CPWD Standard. NS 120.00 Point 739.69 88762.80 AT Par 88762.80 Description:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 3 runs of 1.5
PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable etc. as required as per CPWD Standard. NS 6.00 Each 447.75 2686.50 AT Par 2686.50
surface or in recess, including providing and fixing 5 pin 5/6 A modular socket outlet and 5/6 A separate modular switch, connections etc. as required. NS 4.00 Each 550.07 2200.28 AT Par 2200.28
surface or in recess, including providing and fixing 5 pin 15/16 A modular socket outlet and 15/16 A separate modular switch, connections etc. as required. NS 24.00 Numbers 218.00 5232.00 AT Par 5232.00
LED lighting fixture as per specification SWR/LED LIGHT FITTING(Indoor/outdoor)/001-2016 effective from 18.04.2016 or latest. Including all other required accessories complete. NS 10.00 Numbers 178.24 1782.40 AT Par 1782.40 52 MYSORE DIVISION-ELECTRICAL/SOUTH WESTERN RLY 52 Description:- Supply, fixing, testing and commissioning of 10-watt, 560 mm, 6500 k LED batten fixtures Including all other required accessories complete. NS 10.00 Numbers 171.45 1714.50 AT Par 1714.50 53 Description:- Supply and fixing of 9 W LED bulb along with holder and internal wiring complete. NS 15.00 Numbers 255.00 3825.00 AT Par 3825.00
socket, and modular plate with support frame -1 No each on suitable PVC Box complete. NS 5.00 Numbers 382.00 1910.00 AT Par 1910.00
electronic regulator, fan hooks with all necessary accessories as per specification NS 5.00 Numbers 1751.61 8758.05 AT Par 8758.05 57 Description:- Supply, fixing and commissioning of 200 mm size BLDC Ventilating fan complete. NS 3.00 Numbers 2955.96 8867.88 AT Par 8867.88
35W, minimum air delivery: 70CMM, 3 speed type with remote control and oscillation type suitable to work with 240V, 50Hz single phase AC supply. NS 3.00 Numbers 118.27 354.81 AT Par 354.81
with all required hardware items complete. NS 1.00 Set 10127.63 10127.63 AT Par 10127.63 Description:- Design, Supply, fixing and commissioning of 12 Way SPN Double Door Distribution
and outgoing SP MCB 6-32A 10 Ka - 10 No's with required suitable hardware and internal wiring complete. NS 1.00 Set 30553.74 30553.74 AT Par 30553.74 Description:- Design, Supply, fixing and commissioning of 12 Way TPN Double Door Distribution
and outgoing TP MCB 63 A - 2 No., SP MCB 6-32A - 16 No's along with TP+N SPD - 1 No. with required suitable hardware and internal wiring complete. NS 4.00 Set 3481.00 13924.00 AT Par 13924.00
P+N+E) with 63-amp MCB for welding/charging with GI enclosure. NS 2.00 Set 1635.00 3270.00 AT Par 3270.00
pin 2 pole plug of 20 A capacity of make similar to Legrand 507814 (single phase +neutral +earth) 240V and 20 A DP MCB of Legrand Catalogue No. 408634 including all other connected accessories. NS 2.00 Set 722.00 1444.00 AT Par 1444.00
with suitable size box and hard wares complete. NS 4.00 Numbers 609.00 2436.00 AT Par 2436.00 Description:- Supply of 45-watt 6500k LED street light fixtures, similar to Detailed
dt.11/06/2024) (as per specification SWR/LED LIGHT FITTING (Indoor/outdoor) /001-2016 effective from 18.04.2016 or latest.). NS 4.00 Numbers 223.41 893.64 AT Par 893.64
pipe bracket and hardware complete. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () III-Substation arrangement 8319572.78 NS 2.00 Set 65833.00 131666.00 AT Par 131666.00 Description:- Supply and erection of DP stricture along with double break 400 A GOS and other 68 accessories. MYSORE DIVISION-ELECTRICAL/SOUTH WESTERN RLY NS 1.00 Set 249845.30 249845.30 AT Par 249845.30 Description:- Supply, fixing and commissioning of 11 KV HT Metering cubicle of different CT ratio,
modem and 2 Nos of meters for 3 phase 4 wire metering without load break switch with panel (HT Metering box fabricated out of 3mm MS sheet duly epoxy powder coated) as per EB standard with complete foundation. NS 1.00 Set 549550.00 549550.00 AT Par 549550.00
(1 incomer + 1 breaker+ 1 outgoing) (Schenider Make). 3150000.0 NS 2.00 Numbers 6300000.00 AT Par 6300000.00 0 Description:- Supply, Installation, Testing & Commissioning of BEE 5 Star rated 11KV/433V packaged substation of 500 KVA capacity, equipment comprising Copper wound transformer with suitable rated ACB (motorised) for incoming and 4p microprocessor based incomers and outgoing consisting of 3 way SF6/VCB insulated compact RMU and LT section with MCCB/ACB as incoming and suitable outgoing MCCB feeders with suitable rated copper busbar with SCADA compatibility, with synchronization feature on suitable size foundation ducting arrangement for cabling
metal jelly complete and as per detailed technical specification. Above mentioned switchgears should be motorised type and suitable RTU may be provided for SCADA operation. Bus trunking from Transformer to LT Panel, LT Panel, Automatic power factor correction panel 2 Nos of 400 KVAR, Active Harmonic Filters, TVSS (Transient Voltage suppression system), SPD (Surge protection system), Essential & Non-Essential panel segregation in main panel, Earthing, required interconnections, substation safety equipment's (Fire Extinguisher, Rubber Mats, Rubber Gloves, etc), Spreading of ballast as per Railway Standard and required masonry / foundations, masonry cable ducts, suitable fencing as per standards including LT. NS 1000.00 Metre 287.00 287000.00 AT Par 287000.00
grade of above 185 and up to 400 sq mm size direct in ground including excavation, but excluding sand cushioning, Protective covering. Refilling the trench etc as required as per CPWD Standard NS 10.00 Set 323.25 3232.50 AT Par 3232.50 73 Description:- Brass compression glands for (62 mm) 3 X 240 sq. mm 1.1 KV grade cable. NS 14.00 Set 4691.00 65674.00 AT Par 65674.00 74 Description:- Heat Shrinkable Indoor Type Cable Termination Kit for XLPE 3 C x 240 sq mm cable NS 6.00 Set 5318.00 31908.00 AT Par 31908.00 75 Description:- Heat Shrinkable outdoor Type Cable Termination Kit for XLPE 3 C x 240 sq mm cable NS 6.00 Set 7472.00 44832.00 AT Par 44832.00
and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7-metre-long etc. with charcoal/ coke and salt as required. NS 20.00 Set 5436.01 108720.20 AT Par 108720.20 Description:- L.T. Earthing arrangements for hard soil using 50 mm C-Class GI Pipe- 2.7 Mtr length,
paint and stencilling of earth resistance value with date, including supply and laying of 6 SWG G.I. wire and other hardware to connect equipment at site complete. NS 150.00 Sqm 1032.16 154824.00 AT Par 154824.00
mesh with 10 SWG GI wire and suitable MS angle frame for surrounding the substation area including installation NS 1.00 Set 14415.00 14415.00 AT Par 14415.00
communication capabilities. NS 1.00 Set 340525.00 340525.00 AT Par 340525.00 Description:- Design, Fabrication, Supply, installation, testing and commissioning of complete set of APFC panel of capacity 160 KVAR with 5 KVAR-02 Nos., 10 KVAR-02 Nos., 15 KVAR - 02 Nos, 25 KVAR- 2 Nos, 50 KVAR-1Nos, comprising of housing made of CRCA sheet of 2 mm thick, IP 55,
fully copper conductor, MCCB/MCB protection for all incomers and outgoing etc., suitable to work on three phase 440 Volts, 50Hz AC supply Digital Multi-function meter with RS 485- 1 Nos, RYB indication lamp (LED type) Set, LED indication for MCCB on/OFF condition, including all heat shrinkable sleeves, flexible Cu wires, lugs, sleeves, terminals & PVC troughs with all accessories including mounting arrangements. NS 2.00 Job 6530.39 13060.78 AT Par 13060.78 81 MYSORE DIVISION-ELECTRICAL/SOUTH WESTERN RLY Description:- Liaison work with EB officials in getting Power supply - making Agreement; Commissioning work exclusive of EB Deposit work. NS 4.00 Numbers 180.00 720.00 AT Par 720.00
including stand and other necessary items complete as per the instructions of Railway representative at site. NS 1.00 Job 23600.00 23600.00 AT Par 23600.00 Description:- Design, supply, installation, testing and commissioning of outdoor type static
Capacitor with 3 pole MCB - 1 no,3) 5KVAR Capacitor with 3 pole MCB - 1 no, Installed in outdoor type M S box with necessary wiring and other allied necessary accessories complete.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril-2022.pdf
ATTACHMENT
JPOintenderdocumnets.pdf
ATTACHMENT
Tender Booklet
ATTACHMENT
Advance Correction Slips to GCC
ATTACHMENT
AdvanceCorrectionSlips1-11toGCC-2022.pdf
ATTACHMENT
TB-MYSAugmentationoflaundry._2.pdf
ATTACHMENT
Download all tender documents and submit your bid