Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.1 L+₹1.3 L (6.66%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹21.8 L+₹2.0 L (10.1%)Rejected-AOC 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹21.9 L+₹2.2 L (10.9%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹22.5 L+₹2.8 L (13.9%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹23.4 L
EMD Value
₹46,800
Closing Date
31 Mar 2020, 6:00 pmClosed
GARRISON ENGINEER M
GARRISON ENGINEER M NAVAL AIR STATION ARAKKONAM - 631006
SPECIAL REPAIRS FOR REPLACEMENT OF BER LT PANEL AND PROVN OF VIEW CUTTERS AT VULNERABLE LOCATIONS ALONG THE PERIMETER WALL AT INS RAJALI ARAKKONAM
2020_MES_326568_2
8880 OF 2019-2020
Open Tender
Miscellaneous Works
Item Rate
120 days
GE M NAS ARAKKONAM
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE M NAS ARAKKONAM
₹46,800
Yes
29 May 2020
18 Mar 2020
2 Apr 2020
18 Mar 2020
31 Mar 2020
19 Mar 2020
Amount
Dismantling fencing wire mesh, any type complete all as specified and as directed by Engr-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engr-in-charge.
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC 1:2:4 type B-1 (Using 20mm graded stone aggregates) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded for chamfered angles and throating complete all as specified and as directed by Engr-in-charge.
Supply and fix for mild steel framed work such as grills, swan neck, flat iron for frame, gratings etc., with ends of bars shouldered and/ or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed by Engr-in-charge.
Excavating in post holes (or similar holes) each not exc 0.5 cum in hard /dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50m complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC 1:4:8 type D-2 (Using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed by Engr-in-charge.
Material and labour for cement concrete 1:3:6 type C-2 (Using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed by Engr-in-charge.
Supply and fix for structural steel works as in tubular roof trusses, purlins, vertical posts, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular pipe, channel or flat sections) including distance pieces, cleats, MS plate, riveting including bending and welding, conforming to Fe-410W Gde E-250 quality-A complete all as specified and as directed by Engr-in-charge.
Supply and fix for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc., (each line wire to be measured) complete all as specified and as directed by Engr-in-charge.
Supply and fix for galvanised steel concertina coil of 600mm spirals dia, dia of wire 2.5mm (using coil not less than 8 Kg and stretched to 5 to 6m) complete all as specified and as directed by Engr-in-charge.
Material and labour for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-charge.
Material and labour for two coats of synthetic enamel painting over a coat of red oxide primer to new steel surface of any description not otherwise described over 10cm with or girth including preperation complete all as specified and as directed by Engr-in-charge.
Cutting the bushes, weed, trees and stems of trees including cutting down trees up to 30cm girth and disposal of rubbish material to a distance not exc 50m from site and clear for access the compound/ grill fencing, wall (1m both side of compound) for compound grill /fencing repair etc., complete all as specified and as directed by Engr-in-charge.
Demolition of brickwork or stone /boulder masonry, build in cement mortar including all quoins, arches, pillars etc., but excluding ashlars facings, dressed stonework complete all as specified and as directed by Engr-in-charge.
Material and labour for walling random rubble, regular courses well bonded and solidly hearted, built in CM 1:4 complete all as specified and as directed by Engr-in-charge.
All as per item No.16 here-in-before but except stone.
Material and labour for raking out joints /pointing to square rubble masonary uncoursed or brought up to course work built in cement mortar complete all as specified and as directed by Engr-in-charge.
Material and labour for keyed pointing to square rubble masonry brought upto courses in CM 1:4 complete all as specified and as directed by Engr-in-charge.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean redius built in CM 1:4 complete all as specified and as directed by Engr-in-charge.
Material and labour for 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
All as per item No.21 here-in-before but on other than fair faces complete all as specified and as directed by Engr-in-charge.
Material and labour for preparing new wall surfaces including brooming down (or) steel wire brushing washing and rubbing down with water and applying two coats of cement base paint over one coat of white wash complete all as specified and as directed by Engr-in-charge.
Disconnecting electric connection from the existing 3 Phase LT Panel board with ACB from the existing position including taking up complete LT Panel board with copper bus bar 3 phase and neutral including necessary tools/ plants etc., from the existing locations carefully without any damages to walls/ floor/ building complete including disconnection of earthing lead etc., and making good the disturbed portions of the building/ walls/ ducts/ floor/ other surfaces etc., to match with the existing specification of surfaces and handed over to MES store complete all as specified and as directed by Engr-in-charge.
Fabricate, supply, install, testing and commissioning of self supporting totally enclosed floor mounted on base channel of size 75x75mm and thickness not less than 5mm Indoor type LT panel fabricated from CPRI certified panel builder factory fabricated made out of not less than 2mm thick CRCA sheet, dust and vermin proof, with hinged smoothly openable front and rear door, with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip 32x6mm for connecting provosion - 02 Nos, including ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, necessary tapping using aluminium strip from bus bar for MCCBs etc., complete panel board suitable for 3 phase 4 wire, 415 volts, 50 hz, panel size shall be (including base channel height) not less than size 5m length x 2m height x 1.5m width including comprising of the following items and connecting all outgoing feeder cables using new suitable size lugs of any type by taking down cables from existing panel complete all as specified and as directed by Engr-in-charge. Location: ATH sub station 'G'.
Incoming:- (i) ACB rating 800 Amps,415 Volts, 4P, 50KA ( ICU=ICS=ICW -100%)(1sec) Manual drawout Type ACB with micriporocessor based trip unit with overload,short circuit,instantaneous earth fault protection, with CT's, complete - 01No. Make: Legrand/ Siemens/ Schneider/ABB Outgoing:- (i) MCCB 315 Amps 4P, 50 Hz, 415 Volts, adjustable type with rupturing capacity 35 KA ( ICU=ICS=ICW =100%) - 02 Nos (ii) MCCB 100 Amps 4P, 50 Hz, 415 Volts, adjustable type with rupturing capacity 25 KA ( ICU=ICS=ICW =100%) - 08 Nos (iii) MCCB 200 Amps 4P, 50 Hz, 415 Volts, adjustable type with rupturing capacity 35 KA ( ICU=ICS=ICW =100%) - 03 Nos (iv) MCCB 160 Amps 4P, 50 Hz, 415 Volts, adjustable type with rupturing capacity 25 KA ( ICU=ICS=ICW =100%) - 02 Nos (v) MCB TPN 63 Amps C curve - 08 Nos (vi) MCB TPN 32 Amps C curve - 01 Nos
Demolition and dismantling of concrete of any description from panel plinth /ducts floors etc., not exc 15cms thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge.
Demolition and dismantling of concrete of any description from panel plinth/ ducts floors etc., exc 15cms thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC for foundation for panel plinth/ duct repaired surfaces 1:4:8 type D-2 (Using 40mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC for panel plinth/ duct repairs near panel/ supporting of chequered plate on ducts corners etc., where ever necessary 1:3:6 type C-1 (Using 20mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
Material and labour for replacement of synthetic insulating mat of size 2000x1000x12mm complete all as specified and as directed by Engr-in-charge.
Supply, laying XLPE cable 300 sqmm 3.5 core insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor for replacement of unserviceable cable including connecting up with proper size aluminium lugs, glands wherever necessary in LT panels/ bus bar chamber panel/ joints etc., all as per site requirement including testing on completion complete all as specified and as directed by Engr-in-charge.
Supply and lay pipe galvanised iron tubing light grade of 100mm dia in trenches/ under road or floor/ on wall/ near pole/ panel etc., all as per site requirement complete all as specified and as directed by Engr-in-charge.
Material and labour for earthing complete with copper earth plate electrode of size 600x600x3mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and including copper earth strip 20x3mm protected by GI pipe light grade 40mm bore upto 7.5m and connecting to LT switch gear/ panel etc., as per site requirement including necessary earth work in any type of soil, PCC 1:3:6 type C-1 earth chamber, 40mm thick RCC cover with 8mm dia MS bars 10cm c/c on both ways as reinforcement, 20mm bore water pipe medium grade GI tubing including GI funnel, wire mesh, alternate layers of charcoal and salt crystal and top two inches layers with back filling compound complete all as shown in electrical plate No.03 of MES Schedule 'A' Part-I (2009) and connected to earthing test points complete all as specified and as directed by Engr-in-charge. Note: (i) Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc., (ii) Copper earth strip 20x3mm, GI tubing light grade 40mm dia upto 7.5m deemed to be included the rate quoted by the contractor. (iii) Beyond 7.5m the earth strip 20x3mm and GI pipe light grade 40mm dia shall be measured and paid under relevant item of the schedule. (iv) Quoted rate includes testing after completion from test point and the desired earth resistance shall be not more than 1 ohm. If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
Material and labour for for GI pipe 40mm light grade galvanised, with all fitting laid in trenches/ wall/ floor complete all as specified and as directed by Engr-in-charge. Make: Jindal/Prakash/surya/Tata
Material and labour for fixing copper earth strip 20x3mm with all connecting accessories on wall battern or burried in ground/ floor or drawn in pipe or fixed to poles /wall or any other required at site for earthing etc., complete all as specified and as directed by Engr-in-charge.
Sree Balaji Enterprises
Raju Builders
P JAGANNADHA RAJU
SHRI S SANTHAKUMAR
VARADHI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .