| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC VILLAGE KOJINDA POST OFFICE MANDHANA TEHSIL NARNAUL DISTRICT MOHINDERGARH HARYANA 123001 | NARNAUL | MOHINDERGARH | HARYANA | 123001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.3 L+₹1.7 L (8.42%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹35,846
Closing Date
28 Jan 2021, 5:00 pmClosed
R. Nagender Singh
XEN (E) Rewari
Construction of SCST wing in Govt. ITI at Mohindergarh in Distt. Mohindergarh _Pdg. Power wiring only
2021_HRY_156043_1
PWD/Rewari/jan21
Open Tender
Electrical Works
Works
90 days
XEN (E) Rewari
Refer DNIT
2 documents required · 2 mandatory
₹1,000
₹35,846
13 Aug 2021
15 Jan 2021
29 Jan 2021
15 Jan 2021
28 Jan 2021
15 Jan 2021
Amount
Moulded case Circuit breakers.Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 15 amp. to 60 amp. 415 V,10 KA 3-phase.
100 amp. to 220 amp.415 V,10 KA 3-phase.
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm.
M.S.Sheet . Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Miniature Circuit Breaker and Isolator. Miniature circuit breakers of 9 KA breaking capacity. TP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
TPN MCB of 9 KA breaking capacity 6 amp. to 32 amp.
Earthing .Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required .
Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. stapples of same size.
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections . 25 Sq. mm 3.5 Core Ard. Cable .
35 Sq. mm 3.5 Core Ard Cable .
50 Sq. mm 3.5 Core Ard Cable .
95 Sq. mm 3.5 Core Ard Cable .
16 Sq. mm 4 Core Ard Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. 10 Sqmm to 16 Sqmm Cable 2 to 4 Core .
25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of work. 4 way SP&N (Horizontal)
Supply and erection of MS stand made of 50mmx50mmx6mm angle iron frame and 150cm long, 30cm wide with MS sheet covering size 30cmx30cm 3.15mm thick fixed on the top of board & legs duly embedded in 1:2:4 cement concrete block 30cm below ground level including the cost of cement sand, welding, painting & fabrication charges etc. up to the entire satisfaction of Engineer - in - charge of the work.
Supply, erection, testing and commissioning of wall / free standing floor mounting dust and vermin proof compartmentalized cubical Panel made out of 2.0 mm thick CRCA sheet, required hardware, 3mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel, dully painted by 2 coat of zinc / Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/ Neoprene ruBus Barer gasket of not less than 3 mm thickness, separate detachable gland plate MS base channel, hinged door with inter locking arrangement for equipment / switch gear, Transparent acrylic sheet shall be provided in front of bus bar compartment ot prevent direct access to bus bars. Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection. (only outer area on all sides shall be measured).
Supply and erection of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required size and shape and insulation with colour coading heat shrinkable PVC sleeves complete in all respect up to entire satisfaction of Engineer-in-charge of work.
Supply and erection of moulded case circuit breaker single pole/ 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection required to complete the job the job in all respect up to the entire satisfaction of the Engineer -in - Charge of the work. 4 pole MCCB 6 to 63 amp.
4 pole MCCB 100 amp.
4 pole MCCB 200 amp.
4 pole MCCB 500 amp.
Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 amp. To 100 amp. Suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel/ including making necessary connections with petty material required to complete the job. 100 amp. 4 pole ON load changeover switch
Supply, installation, testing and commissioning of Load bank with digital meter module cost of digital Amp./Volt meter with sector switch wiring etc. suitable for operation of 240/415 volts A.C supply with both side cable allay inter connection and fixing the same in existing MS pedestal complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-charge of work.Load Bank 8 way 250 Amp.
Supply & erection of cable tray made out of 2 mm thick galvanized perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer - in - Charge of the work. 40 x 100 mm
Supply & erection of factory manufactured cable tray cover made of the G.I. sheet complete with fastener nuts bolts and in position including the petty material required to complete the job in all respect up to the entire satisfaction of Engineer - in - Charge of the work. Suitable for 40 x 100 mm
Suitable for 50 x 150 mm
Supply and erection of double door sheet, steel superline/ Powerline/ Loadline TPN vertical distribution boards suitable for TP/FP vertical MCCBs 25 KA MCCB up to 250 amp as incomer (but without cost of MCCB) fitted with bus bar, neutral link & Blanking plates complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of work. 8 Way (V)
KKM Engineering Solutions Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .