Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.9 LAccepted-AOC | ₹47.9 L Quoted ₹48.0 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹50.6 LRejected-AOC 17 SAI CITY IIM ROAD SAI CITY LUCKNOW UTTAR PRADESH 226013 | LUCKNOW | UTTAR PRADESH | 226013 | ₹50.6 L | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | M/S Gupta and Sons L2 | AGGARWAL SONS L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means in any type of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in charge | 160 | Cum | 250 ₹40,000 | 225 ₹36,000 |
| 2.00 | Earth work in excavation by mechanical means in any type of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift exceeding 1.5m but not exceeding 3.0m, as directed by Engineer-in charge | 160 | Cum | 250 ₹40,000 | 270 ₹43,200 |
| 3.00 | Earth work in excavation by mechanical means in any type of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift exceeding 3.0m but not exceeding 4.5m, as directed by Engineer-in charge | 40 | Cum | 400 ₹16,000 | 300 ₹12,000 |
| 4.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers of any type of soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge. | 320 | Cum | 150 ₹48,000 | 100 ₹32,000 |
| 5.00 | M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete and sub base all as specified and directed by Engineer - in - Charge | 15 | Cum | 2,800 ₹42,000 | 3,500 ₹52,500 |
| 6.00 | M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed. | 60 | Cum | 7,000 ₹4.2 L | 6,350 ₹3.8 L |
| 7.00 | M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed by Engineer - in - Charge. | 45 | Cum | 7,000 ₹3.1 L | 6,900 ₹3.1 L |
| 8.00 | M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5mtr clear span etc complete all as specified and directed. | 65 | Cum | 7,000 ₹4.5 L | 6,900 ₹4.5 L |
| 9.00 | M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in slabs supported on walls, beams, columns and in shelves, ramp slabs, the like all as specified and directed by Engineer - in - Charge . | 45 | Cum | 6,000 ₹2.7 L | 6,900 ₹3.1 L |
| 10.00 | M & L Reinforced cement concrete M-30 design mix as in chajjas, fins, fascias, louvers, parapets and railing etc and the like all as specified and directed by Engineer - in - Charge. | 15 | Cum | 6,000 ₹90,000 | 6,900 ₹1.0 L |
Tender Value
₹48.1 L
EMD Value
₹96,120
Closing Date
17 Nov 2025, 6:00 pmClosed
Garrison Engineer
GE (U) Chandimandir Pin-134107
CA NO GE(U)/CHM-29/2025-26 PROVN OF FIRE EXIT RAMP FROM ICU AT SECOND FLOOR OF MAIN HOSPITAL BLDG AT COMMAND HOSPITAL (WC) CHANDIMANDIR
2025_MES_730361_2
GE(U)/CHM-29/2025-26
Open Tender
Civil Works
240 days
GE (U) Chandimandir
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (U) Chandimandir
₹96,120
Yes
30 Dec 2025
31 Oct 2025
21 Nov 2025
31 Oct 2025
17 Nov 2025
10 Nov 2025
Amount
Earth work in excavation by mechanical means in any type of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in charge
Earth work in excavation by mechanical means in any type of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift exceeding 1.5m but not exceeding 3.0m, as directed by Engineer-in charge
Earth work in excavation by mechanical means in any type of soil (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift exceeding 3.0m but not exceeding 4.5m, as directed by Engineer-in charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers of any type of soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete and sub base all as specified and directed by Engineer - in - Charge
M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed.
M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed by Engineer - in - Charge.
M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5mtr clear span etc complete all as specified and directed.
M & L Reinforced cement concrete M-30 design mix using 20mm graded stone aggregate as in slabs supported on walls, beams, columns and in shelves, ramp slabs, the like all as specified and directed by Engineer - in - Charge .
M & L Reinforced cement concrete M-30 design mix as in chajjas, fins, fascias, louvers, parapets and railing etc and the like all as specified and directed by Engineer - in - Charge.
M & L pre-cast RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in landing, chajjas, shelves, cover slabs and similar articles of any thickness, size or shape including necessary from work, finishing the concrete surfaces fair and even in cement mortar and setting in cement Mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
M & L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
M & L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete all as specified and directed by Engineer - in - Charge.
Form work to sides and soffits of floor or roof beams, lintels cantilevers, shelves including supports, over hangs and the like for rough finished surfaces complete all as specified and directed by Engineer – in – Charge.
M & L form work to soffits of suspended slabs such as roof slab, ramp slabs, and similar work not exceeding 200mm thick for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge .
Form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed by Engineer – in – Charge.
M & L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
M&L Brick work with sub class 'B' old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .
M & L mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 19 here in before but 5mm and over for as in stirrups, spacers and binders all as specified and directed by Engineer - in - Charge.
M & L rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge .
M & L 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed by Engineer - in - Charge .
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge . Note:- The rates do not include for the supply of integral water proofing compound, which shall be paid for in addition at “supplied only rates separately, as applicable.
Supply only integral water proofing compound.
M & L Sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engineer - in - Charge.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over plastered or unplastered or concrete surfaces including water proof putty and preparation of new surfaces complete all as specified and as directed by Engineer-in-Charge.
M & L three coats of white wash including preparing new plastered or unplastered surfaces of ceiling complete all as specified and directed by Engineer - in - Charge.
S & F PVC pipes (SWR) single socketed with rubber ring joints 110mm dia fixed to wall complete all as specified and directed by Engineer - in - Charge .
S&F PVC (SWR) bends any radius bore of 110 mm with access door all as specified and directed by Engineer - in - Charge
Demolition of Reinforced cement concrete (reinforcement cut as required to facilitate demolition) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge .
All as per Srl item No. 31 here-in-before but one 05 Amp socket outlet point on independent board controlled by modular switch, 6 Amp, single pole, one way, 240V, complete all as specified and directed.
All as per Srl item No. 31 here-in-before but one 05 Amp socket outlet point on same board controlled by modular switch, 6 Amp, single pole, one way, 240V, complete all as specified and directed.
S&F modular switch 1 way 6 Amp, 1 module, one way complete all as specified.
S&F modular socket 6 Amp, 2/3 pin combined, 2 module complete all as specified.
S & F surface mounted (As per site requirement) slim square/round type LED panel with die cast aluminium housing and smooth powder coated finish with antiglare UV stabilized diffuser and separate energy efficient eletronic driver having wattage 15 watt LED panel light having dimensions 120x120mm and making connection accessories complete all as specified and directed by Engineer - in – Charge.
S & F LED Beacon step light CRCA housing, powder coating with PC diffuser inbuilt IP 65 protection for outdoor appllication, wattage 06 watt rated luminaire efficiancy 110 lm/W, suitable for concealed into surface wall/floor, its super bright LED life span not less than 50000 hours, including LED strip/CDL, driver efficiency > 85% and others accessories as per manufactures recommendation including fixing arrangement complete all as specified and directed by Engineer - in – Charge.
S & F MCB distribution board of sheet metal single pole and neutral 8 way, double door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S&F as in repairs MCB Single Pole and Neutral (SPN) 32-40 Amps, 240 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
S&F MCB Single Pole 06-32 Amps, 240 Volt, 'B' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
S & F submain wiring with two single core cables PVC FRLSH insulated unsheathed 4 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC insulated 4 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
M/S Gupta and Sons (BID ID -3474930)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_826040.xls
BOQ • 0.33 MB
Tenderdocuments29.pdf
Tender Documents • 1.58 MB
Download all tender documents and submit your bid