Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹47.1 L+₹6.0 L (14.5%)Rejected-AOC | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | L3₹47.8 L+₹6.7 L (16.2%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L3 | Rejected-AOC NOT BEING LOWEST | |
| 4 | L4₹55.4 L+₹14.2 L (34.5%)Rejected-AOC | L4 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹48.2 L
EMD Value
₹96,500
Closing Date
8 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
REPAIR, MAINTENANCE AND REPLACEMENT OF DEFECTIVE ITEMS OF LT DISTRIBUTION SYSTEM STPS, AND MISC ITEMS AT 2 WING AND TECH AND OTM AREA UNDER GE (AF) LOHEGAON AT AF STN PUNE
2023_MES_582005_2
8662/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF LOHEGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹96,500
Yes
5 Jul 2023
11 Mar 2023
10 Apr 2023
11 Mar 2023
8 Apr 2023
27 Mar 2023
Amount
SCHEDULE 'A'
Taking down Old unserviceable LT UG cable of service from connection or distribution system of any size and removing from site complete all as specified and directed by Engr-in-Charge. Excavation and earth work will be measured seperately)
Material and labour for painting to existing steel tubular poles 7/9/11 mtr long including cross arms,looping box,GI pipe bracket,clamps etc. with one coat of aluminium paint including preparation of surfaces and feeder name and pole number with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as specified and directed by Engr-in-Charge.
Material and labour for painting to feeder pillar box/LT Panel & duct cover etc including angle iron frame with two coats of grey synthetic enamel paint including welding of door with proper size new hinges of suitable size and locking arrangements where required complete all as specified and directed by Engr-in-Charge.
Cutting trimming of hanging/extended branches of trees upto a distance 3 meter from the over head HT/LT line and making the line clear upto the entire length of the feeder including removal and disposing of the cut tree/branches 50 meter away from the site complete all as specified and directed. Note :- Quoted rates shall deemed to be included use of T&P. One span comprises of distance between one pole to another including all trees in its vicinity including switch off/on, electric cable connection or disconnection. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department.
M & L for services for cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine ccomplete all as specified and directed by Engr-in-Charge.
Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below all as specified and directed. Make : MS Seal / Reychem / Denson 35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
150 sqmm 3.5 core
185 sqmm 3.5 core
300 sqmm 3.5 core
Supply and fix GI Pipe Light grade sizes 80 mm dia with all connected accessories sizes complete all as specified and directed by Engr-in-Charge.
Supply and fix GI Pipe Light grade sizes 50 mm with all connected accessories complete all as specified and directed by Engr-in-Charge.
Supply and fix GI Pipe Light grade sizes 40 mm with all connected accessories of complete all as specified and directed by Engr-in-Charge.
Supplying and erecting (in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with blach bituminous paint for embedded portion of polecomplete all as specified and directed by Engr-in-Charge.
M& L for danger notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letter figures and conventional skull and tongue in signal red colour and fixed with MS clamps bolts nuts of approved size LT, 20x15cm complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation etc complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate etc complete all as specified and directed by Engr-in-Charge.
Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified for following size:- 25 sqmm 4 core
35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
300 sqmm 3.5 core
Taking out carefully unserviceable cable up to 70 Sqmm from wall and relaying same in same or other indicated location, including saddles, clamps, spacers, clamps screws etc complete after testing all as directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc.complete all as specified and directed by Engr-in-Charge. Soft/loose soil
Hard/dense soil
Soft/disintegrated rock
All as per item No. 16 above but for depth exc 1.5 mtrs but n.exc 3 Mtr and getting out in soft/disintegrated rock complete all as specified and directed by Engr-in-Charge.
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for Soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for Hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for Soft/disintegrated rock complete all as specified and directed by Engr-in-Charge.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level in soils complete all as specified and directed by Engr-in-Charge.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level in rocks.complete all as specified and directed by Engr-in-Charge.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable .complete all as specified and directed by Engr-in-Charge. [Note : Measuremenet will be done after punning]
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick, the size of brick shall be 225mm X 112mmX75mm.complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCCB FP 400 Amps 36 KA including connections and testing for proper functioning.and including removal of old Unserviable MCCB's complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCCB FP 315 Amps 36 KA including connections and testing for proper functioning and including removal of old Unserviable MCCB's .complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCCB FP 250 Amps 25 KA including connections and testing for proper functioning and including removal of old Unserviable MCCB's.complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCCB FP 200 Amps 25 KA including connections and testing for proper functioning.and including removal of old Unserviable MCCB'scomplete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCCB FP 160 Amps 25 KA including connections and testing for proper functioning.complete and including removal of old Unserviable MCCB's all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCCB TP 200 Amps 25 KA including connections and testing for proper functioning and including removal of old Unserviable MCCB's complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair t of MCCB TP 160 Amps 25 KA including connections and testing for proper functioning and including removal of old Unserviable MCCB's complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCCB TP 100 Amps 25 KA including connections and testing for proper functioning and including removal of old Unserviable MCCB'scomplete complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCCB TP 63 Amps 25 KA including connections and testing for proper functioning and including removal of old Unserviable MCCB's complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of digital Volt meter (0-500) including connections and testing for proper functioning and including removal of old Unserviable materialcomplete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of digital ammeter including connections and testing for proper functioning and including removal of old Unserviable material complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of Indicating Lamp R. Y. B (LED) Type including connections and testing for proper functioningand including removal of old Unserviable material complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of CTs of required rating including connections and testing for proper functioning complete all as specified and directed by Engr-in-Charge.
Supply install, test and commissioning of indoor type LT Panel Powder coated, free standing type compartmentalized in construction, front & back openable with locking arrangment, the panel shall be manufactured from makes specified in CA made out of 2 mm thick CRCA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Copper bus bars. The TPN copper bus bars shall be of rating 1.5 times of the incomer MCCB/CHangeover, and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB of rating 125 Amps. The Out Going MCCB 125 Amps & above Shall be provided with copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 50 mm X 50mm X 6mm & detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back openable lockable /openable by key from both sides. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, & Reconnecting the cables to new panels, replacing of cable glands, lungs and including PCC foundation, excevation, foundation bolts Note of srl item 41 - The Layout diagram of panel shall be submitted for contractor & got appoved from GE before fabrication. Make of MCCB/Change Over Shall be Havells/Legrand/L&T THe panel shall have the following acessories (i) Change over switch Four Pole of cap 800 Amp-01 No (ii) MCCB 800 Amps Four Pole 50 kA, 415 Amps - 01 No (To be provided at Out Going end of Change over) (iii) Outgoing MCCB TP 415 Volt 100 Amps 16 kA - 08 Nos (iv) Outgoing MCCB TP 415 Volt 500 Amps 25 kA - 01 Nos (v) LED Type RYB Phase Indicator -01 Set (vi) Digital VAFPF Meter -01 Nos (vii) Coper BUs Bar
Supply install, test and commissioning of out door type LT Panel Powder coated, free standing type compartmentalized in construction, double door front & back openable with locking arrangment, canopy on top, the panel shall be manufactured from from makes specified in CA made out of 3 mm thick CRCA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Copper bus bars. The TPN copper bus bars shall be of rating 1.5 times of the incomer MCCB/CHangeover, and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB of rating 125 Amps. The Out Going MCCB 125 AMps & above Shall be provided with copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 50 mm X 50mm X 6mm & detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back openable lockable /openable by key from both sides. Note of srl item 42-The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5 Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, & Reconnecting the cables to new panels, replacing of cable glands, lungs and including PCC foundation, excevation, foundation bolts Note - The Layout diagram of panel shall be submitted for contractor & got appoved from GE before fabrication. Make of MCCB/Change Over Shall be Havells/Legrand/L&T (i) Incoming MCCB FP 415 Volt 400 Amps 36 kA - 01 Nos (ii) Outgoing MCCB TP 415 Volt 315 Amps 16 kA - 1 Nos (iii) Out Going MCCP TP 415 Volts 200 AMps - 4 Nos (iii) Outgoing MCCB TP 415 Volt 100 Amps 16 kA - 04 Nos (iv) LED Type RYB Phase Indicator -01 Set (v) Digital VAFPF Meter -01 Nos
Supply install, test and commissioning of Out door type LT Panel Powder coated, free standing type compartmentalized in construction, double door front & back openable with locking arrangment, the panel shall be manufactured make given in CA made out of 3 mm thick CR CA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Copper bus bars. The TPN copper bus bars shall be of rating 1.5 times of the incomer MCCB/CHangeover, and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB of rating 125 Amps. The Out Going MCCB 125 AMps & above Shall be provided with copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 50 mm X 50mm X 6mm & detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back openable lockable /openable by key from both sides. Note of srl item 43 The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, & Reconnecting the cables to new panels, replacing of cable glands, lungs and including PCC foundation, excevation, foundation bolts Note - The Layout diagram of panel shall be submitted for contractor & got appoved from GE before fabrication. Make of MCCB/Change Over Shall be Havells/Legrand/L&T (a) Incoming MCCB FP 415 Volt 400 Amps 36 kA - 01 Nos (b) Out Going MCCB FP 415 Volt 200 Amps 16 kA - 02 Nos MCCB FP 415 Volt 100 Amps 16 kA - 03 Nos LED Type RYB Phase Indicator -01 Set (c) Digital VAFPF Meter -01 Nos (d) Copper Bus Bar
Supply install, test and commissioning of Out door type LT Panel Powder coated, free standing type compartmentalized in construction, double door front & back openable with locking arrangment, the panel shall be manufactured from make specified in CA made out of 3 mm thick CRCA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Copper bus bars. The TPN copper bus bars shall be of rating 1.5 times of the incomer MCCB/CHangeover, and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB of rating 125 Amps. The Out Going MCCB 125 AMps & above Shall be provided with copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 50 mm X 50mm X 6mm & detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back openable lockable /openable by key from both sides. Note of srl item 44 .The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, & Reconnecting the cables to new panels, replacing of cable glands, lungs and including PCC foundation, excevation, foundation bolts Note - The Layout diagram of panel shall be submitted for contractor & got appoved from GE before fabrication. Make of MCCB/Change Over Shall be Havells/Legrand/L&T The Panel shall have following acessories (a) Incoming MCCB FP 415 Volt 250 Amps 36 kA - 01 Nos (b) Outgoing MCCB FP 415 Volt 100 Amps 16 kA - 03 Nos (c) LED Type RYB Phase Indicator -01 Set (d) Copper Bus Bar (e) Digital VAFPF Meter -01 Nos
Supply install, test and commissioning of Out door type LT Panel Powder coated, free standing type compartmentalized in construction, double door front & back openable with locking arrangment, the panel shall be manufactured from make specified in CA made out of 3 mm thick CR CA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Copper bus bars. The TPN copper bus bars shall be of rating 1.5 times of the incomer MCCB/CHangeover, and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB of rating 125 Amps. The Out Going MCCB 125 AMps & above Shall be provided with copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 50 mm X 50mm X 6mm & detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back openable lockable /openable by key from both sides. Note of srl item 45 . The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, & Reconnecting the cables to new panels, replacing of cable glands, lungs and including PCC foundation, excevation, foundation bolts. Note - The Layout diagram of panel shall be submitted for contractor & got appoved from GE before fabrication. Make of MCCB/Change Over Shall be Havells/Legrand/L&T (a) Incoming MCCB FP 415 Volt 400 Amps 36 kA - 01 Nos (b) Out Going MCCB FP 415 Volt 200 Amps 16 kA - 02 Nos MCCB FP 415 Volt 100 Amps 16 kA - 03 Nos LED Type RYB Phase Indicator -01 Set (c) Digital VAFPF Meter -01 Nos (d) Copper Bus Bar
Supply install, test and commissioning of In door type LT Panel Powder coated, free standing type compartmentalized in construction, double door front & back openable with locking arrangment, the panel shall be manufactured from from makes specified in CA made out of 2 mm thick CRCA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Copper bus bars. The TPN copper bus bars shall be of rating 1.5 times of the incomer MCCB/CHangeover, and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB of rating 125 Amps. The Out Going MCCB 125 AMps & above Shall be provided with copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 50 mm X 50mm X 6mm & detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back openable lockable /openable by key from both sides. Note of srl item 46 The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, & Reconnecting the cables to new panels, replacing of cable glands, lungs and including PCC foundation, excevation, foundation bolts Note - The Layout diagram of panel shall be submitted for contractor & got appoved from GE before fabrication. Make of MCCB/Change Over Shall be Havells/Legrand/L&T The Panel shall have following acessories (a) Incoming MCCB FP 415 Volt 400 Amps 36 kA - 01 Nos (c) Outgoing MCCB FP 415 Volt 200 Amps 16 kA - 02 Nos (d) Outgoing MCCB FP 415 Volt 100 Amps 16 kA - 04 Nos (e) LED Type RYB Phase Indicator -01 Set (f) Copper Bus Bar (g) Digital VAFPF Meter -01 Nos
M & L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified.
S & F GI earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed by Engr-in-Charge.
M & L for opening of MCB DB /MCCB DB front door & replacing of burnt wires & tesing comple after carrying out repairs . Note :- (i) The representative of the contrcator (Supervisor - 1 No, Electrician Skilled - 1 No, Helper - 1 No shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contrcat period (ii) MCCB & MCB required to be replaced shall be paid under respective item of this schedule as Supply & fixing. (iii) Minor spares such as connectors, wires, lugs are deemed to be inclusive of the quoted rate.
Supply And Fix in repairs MCCB DB TPN 6 Way double door IP 43 Protection prewired suitable for Triple Pole 125 A incomer MCCB with the following acessories, a) MCCB TP 125 A 25 KA 415 Volt - 1 Nos b) Bus bar, Din rail , Neutral link Make - Indoasaian/Legrand/ABB/Schnider
Supply & Fixing of MCB DB Double Door SPN 12 way 240 volts. complete all as specified and directed by Engr-in-Charge. Make - Legrand/ABB/Schnider
Supply & Fixing of MCB SP, 240 volt, 6 to 32 Amps, 10 KA, C Curve, complete all as specified and directed by Engr-in-Charge Make - Indo Asian/Legrand/ABB/Schnider
Supply & Fixing of MCB SPN, 240 volt, 6 to 40 Amps, 10 KA, C Curve, complete all as specified and directed by Engr-in-Charge Make - Indo Asian/Legrand/ABB/Schnider
Supply & Fixing of MCB TPN, 240 volt, 63 Amps, 10 KA, C Curve, complete all as specified and directed by Engr-in-Charge Make - Indo Asian/Legrand/ABB/Schnider
Supply & Fixing of MCB TP, 240 volt, 63 Amps, 10 KA, C Curve,complete all as specified and directed by Engr-in-Charge Make - Indo Asian/Legrand/ABB/Schnider
Monthly maintenance / servicing of Sewage Treatment Plant as per regulation and Sewage Pumping House at various lacations as mentioned below :- Note : i. Unit rate quoted by tenderer is inclusive of checking of system monthly by skill mechanic (must have experience in respective field) with helper and necessary servicing & repair greecing,oilng of plant equipment ,filter back wash. the register will be maintained to that effect. ii. In addition to above, specific emergency complaints from time to time shall be attended after receiving the same. iii. In addition to above supervisor will provide instructions to operator for smooth operatoion and proper treatment of STP. a) N.P. Area STP (capacity-1600 KLD)
MAP Pocket 1 Sewage Pump House
Viman Nagar STP (Capacity-600 KLD)
Latiff Hall Sewage Pump House
Chandan Nagar STP (MAP Pocket 3) (capacity- 190 KLD)
Akash Nagar STP (MAP Pocket 4) (Capacity -165 KLD)
Material and labour for Cleaning of sewage well of STP Plant of following Capacity 1600KLD,600KLD,190KLD,165KLD described below :- (i) Dewatering with submersible / sludge pump to empty the sump/tank upto base level. (ii) Removing sludge from sump wall and bottom with the help of special sludge pump and remaining dirt which may have hidden in rough slots of the bottom mannualy with brush.(iii) After cleaning the sump apply bleaching powder for disinsfection of sump (iv) write cleaned on date and next clean in bluePVC sheet with white letter afte cleaning. As directed by Engineer in charge a) Receving Sump
Equalization Tank (Reactor Tanks )
Tube Settler
CCT, FFT, TWT
UG sump 1.5 lakh gln (treated water Sump)
UG sump 1.0 lakh gln (treated water Sump)
M & L for Repairs to Air Blower including replacement of the following worn out spare parts and testing complete all as directed by Engineer-in-charge.(as Per existing Make) A) Gear Assembly as per existing make and capacity
Slight Glass Assembly as per existing make and capacity
Bearing Set (each Set =4 Nos) as per existing make and capacity
Oil Seal & Oil Ring as per existing make and capacity
V Belt as per existing make and capacity
Oil for Blower as per existing make and capacity
M & L for Repairs of DMF( Dual Media Filter) Media replacing the worn out spare parts and overhauling the same incl testing complete all as directed by Engineer-in-charge.(as Per existing Make) (a) Filtering Sand (as per existing size)
M & L for Repairs of ACF (activated Carbon Filter) Media replacing the worn out spare parts and overhauling the same incl testing complete all as directed by Engineer-in-charge.(as Per existing Make) (a) Activated Carbon
Taking up or Down unserviceable Heavy duty flexible Kanaflex pipe and replace with new along with MS clamps and nut bolts with all fiiting complete all as specified and directed by Engr-in-Charge 50 mm dia
80 mm dia
100 mm dia
150 mm dia
Taking down of following unserviciable old GI tubing any grade and fittings connections ( including dewatering of trench) and removal from site complete all as specified and directed by Engr-in-Charge 25 mm dia bore
50 mm dia bore
80mm dia bore
100mm dia bore
150mm dia bore
Supply & lay and jointing tubing medium grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc fixed to walls ceiling or laid on floor / roof etc all as specified of following sizes :- 25 mm dia bore
50 mm dia bore
80mm dia bore
100mm dia bore
150mm dia bore
M&L for replacement of butterfly valve dia including taking out existing Unsv butter fly valve and making good to the disturbed surface matching to existing specification 80 mm dia
100 mm dia
150 mm dia
Material and labour for reparing/maintenance of existing electrical panel boards of pump sets by replaing worn out spares as cable glands/ lugs pin type, U type,burn wire and connectors etc, cleaning of panel board, tightening of cable connection to avoid sparking, insulating bus bars bracket portion of conductor and to ensuring proper function of the panel board all as directed by Eng-in-Charge.
S & F Indicator Lamp LED Type complete all as specified and directed by Engr-in-Charge
S & F of voltmeter of 0 to 500 Volts suitable for existing panel board and taking out of old unserviceable volt meter complete all as directed by Engr-in-Charge.
S & F ammeter 0 to 30 Amps suitable to panel board and and taking out of old unserviceable ammeter complete all as specified and directed by Engr-in-Charge.
S & F MCCB upto 160 Amp,35ka to panel board andtaking out of old unserviceable MCCB complete all as specified and directed by Engr-in-Charge.
S & F MCCB upto 100 Amp,35ka to panel board andtaking out of old unserviceable MCCB complete all as specified and directed by Engr-in-Charge.
S & F MCCB upto 63 Amp,to panel board andtaking out of old unserviceable MCCB complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCB TPN 63 Amp, 4 pole with rupturing capacity 10 KA C curve complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCB 32 Amp, 4 pole with rupturing capacity10 KA C curve.complete all as specified and directed by Engr-in-Charge.
S & F in replacement of 3 pole power contactor heavy duty with contineous current rating of upto 25 Amp AC 3, 415 Volt.complete all as specified and directed by Engr-in-Charge.
S & F in replacement of 3 pole power contactor heavy duty with contineous current rating of upto 32 Amp AC 3, 415 Voltcomplete all as specified and directed by Engr-in-Charge.
S & F in replacement of 3 pole power contactor heavy duty with contineous current rating of upto 70 Amp AC 3, 415 Volt.complete all as specified and directed by Engr-in-Charge.
S & F in replacement of thermal over load relay 20 to 32 Amp,415 Volt.complete all as specified and directed by Engr-in-Charge.
S & F in replacement of thermal over load relay 10 to 16 Amp, /415 Volt.complete all as specified and directed by Engr-in-Charge.
S & F in replacement of thermal over load relay 2.5 to 4 Amp, / 415 Volt.complete all as specified and directed by Engr-in-Charge.
S & F 3 phase, DOL Starter ,to panel board suitable to 5 hp motor and taking out of old unserviceable DOL Starter complete all as specified and directed by Engr-in-Charge.
S & F star delta Starter ,to panel board suitable to 12.5 hp motor and taking out of old unserviceable delta Starter complete all as specified and directed by Engr-in-Charge.
Supply and replacing single phase preventor suitable for submersible mud pump sets complete all as specified and directed by Engr-in-Charge. (Make : as per existing)
M & L for taking down induction motor 3 phase, 415 Volt capacity 2/3 HP, incoming disconnection electric connections, dismantling slots and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing, replacing worn out bearing as per existing size, painting with super enameled paint as per colour coat assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing complete all as specified and directed by Engr-in-Charge.
M & L for taking down induction motor 3 phase, 415 Volt capacity upto 5 HP, incoming disconnection electric connections, dismantling slots and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing, replacing worn out bearing as per existing size, painting with super enameled paint as per colour coat assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing all as directed.
M & L for taking down induction motor 3 phase, 415 Volt capacity 7.5 HP to 12.5 HP, incoming disconnection electric connections, dismantling slots and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing, replacing worn out bearing as per existing size, painting with super enameled paint as per colour coat assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing all as directed.
M & L for taking down induction motor 3 phase, 415 Volt capacity 15 HP to 35 HP, incoming disconnection electric connections, dismantling slots and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing, replacing worn out bearing as per existing size, painting with super enameled paint as per colour coat assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing all as directed.
M & L for taking up and Repairs to open well type submersible mud /non clog motor of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weight of suoer enameled copper conductor incl renewal of thrust plate, reassembling, testing and commissioning complete all as directed by Engr-in-Charge.
M & L for taking up and Repairs to open well type submersible mud/non clog motor of electric driven of any type make and capacity upto 12.5 HP incl rewinding of the motor with same gauge and weight of super enameled copper conductor incl renewal of thrust plate, reassembling, testing and commissioning complete all as directed by Engr-in-Charge.
Supply and fix of spares for pumps of up to capacity up to 5 hp, Including all the spares i.e impeller,shaft replacement and macining work of shaft,balancing of rotor, oil seal ,bearing,replacing of lubcricant oil etc
Supply and fixing of spares for pumps of up to capacity 12.5 hp, Including all the spares i.e impeller,shaft replacement and macining work of shaft,balancing of rotor, oil seal ,bearing,replacing of lubcricant oil etc
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil for cleaning surface area and cutting shurbes/grass & bushes and remove the material at various installation at site. all as directed by Engr-in-charge.
M & L for Surfaces painting of I STP plant of various capacity (1600 KLD,600KLD,165KLD,190KLD) and equipments including preparing of all surface,two coat of surface enamel paint over one coat of red oxide of any description over 10cm in width or girth,colour coding as discribe by Engineer in charge
M & L for Surfaces painting of I STP plant of various capacity (1600 KLD,600KLD,165KLD,190KLD) and equipments including preparing of all surface any description by scrapping old paint and white wash of various tanks over width or girth,colour coding as discribe by Engineer in charge
M& L for name board in PVC sheet 2mm thick blue colour with computerized printing in white letter for STP plants and sheet of size 36"x12" complete all as specified and directed by Engr-in-Charge Notes :- content to be printed will be gevin by Engineer in charge during execution.
M& L for spraying of glyphosate 41% SL Glykol Herbicide to remove vegatation from E/M Installations complete all as specified and directed by Engr-in-Charge
Supply specified acclimated BIO CULTURE of microbial culture of enzymatically breaking down of a broad range of organic compound,phosphate and ammonical nitrogen in sewage and waste water, used in reduction of BOD ,COD,Ammonical nitrogen and phosphorus and eliminating of foam,odour in waste water for used in Aeration tank of STP (MBBR/MBR/SBR/ASP),purity 99.99% powder form having shelf life of 24 months complete all as specified and directed by Engr-in-Charge
Supply and fix in replacement of submercible rubber PVC 2.5 Sqmm, 8 core copper cable HR 120 deg C, 1100 volts conforming IS 694:1990 complete all as specified and directed by Engr-in-Charge . Make: HAVELLS/RR Kabel/Polycab.
Supply only Calcium Hypo Chlorite 65% chlorine content (Calcium based granular) complete all as specified and directed by Engr-in-Charge
K K ENGINEERING SERVICES
sapana enterprises
somnath engineering corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .