Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAdmitted-Finance | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S ISHAN ELECTRICAL and MECH. ENGG. WORKS L1 |
|---|---|---|---|---|
| 1.00 | SITC of 2.0 TR window air conditioner to be installed at various section of Pathology Department of GMC, Jammu with all accessories (along with outdoor stand and drain pipe) having below give specifications:
Air Conditioning Technology: Inverter
Min. Star Rating: 3
Max. Cooling Capacity >= 21000 BTU/hr
Air Flow Volume(High) >= 465 CFM
Ambient upper temperature range >= 52 degree Celsius
Refrigerant: Ecofriendly
Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges.
Make: O-General/Bluestar/Hitachi/Diakin/carrier. | 8 | nos. | 57,500 ₹4,60,000 Lowest |
| 2.00 | SITC of 2.0 TR Split air conditioner (Hot and Cold) to be installed at HOD room of Pathology Department of GMC, Jammu with all accessories (along with outdoor stand and drain pipe) having below give specifications:
Air Conditioning Technology: Inverter
Min. Star Rating: 3
Max. Cooling Capacity >= 21838 BTU/hr
Air Flow Volume(High) >= 703 CFM
Ambient upper temperature range >= 52 degree Celsius
Refrigerant: Ecofriendly
Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges.
Make: O-General/Bluestar/Hitachi/Diakin/carrier. | 1 | nos. | 74,000 ₹74,000 Lowest |
| 3.00 | SITC of 2.0 TR Split air conditioner to be installed at various section of Pathology Department of GMC, Jammu with all accessories (along with outdoor stand and drain pipe) having below give specifications:
Air Conditioning Technology: Inverter
Min. Star Rating: 3
Max. Cooling Capacity >= 21495 BTU/hr
Air Flow Volume(High) >= 554 CFM
Ambient upper temperature range >= 52 degree Celsius
Refrigerant: Ecofriendly
Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges.
Make: O-General/Bluestar/Hitachi/Diakin/carrier. | 16 | nos. | 63,000 ₹10,08,000 Lowest |
| 4.00 | Supply, Installation, Testing and Commissioning of 5KVA copper wound automatic wall mounted voltage stabilizer input Voltage 130-280 V & of superior quality ISI mark for ACs.
Make: Microtek/Aulten/Servokon/Electricfield | 25 | nos. | 11,500 ₹2,87,500 Lowest |
| 5.00 | Providing and fitting of SPN of 32 Amp of standard make i.e. Havells, L&T/ABB with Gang box (complete with fittings) for, 1.5TR Capacity ACs to be installed. | 25 | nos. | 500 ₹12,500 Lowest |
| 6.00 | Providing and fitting of extra copper pipe with insulation. | 500 | ft | 200 ₹1,00,000 Lowest |
| 7.00 | Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of interconnecting stabilizers, digital timer panel and electrical panel . Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. | 1 | job | 80,000 ₹80,000 Lowest |
| 8.00 | Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning units (Outer & Inner) to the Stabilizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. | 1 | job | 40,000 ₹40,000 Lowest |
| 9.00 | Providing and Installation of Heavy Duty Main Electrical Panel (Powder Coated)-250A which includes MCCB 250A-4 Pole, 50 Ka breaking circuit capacity of standard make i.e. Havells, L&T of size 3’×3’6”×15” along with spread links and 04 nos .buss bar of capacity 250A each along with holes for thimbling of the cable with nut bolt arrangement as per site requirement for Connection of incoming cable connecting using aluminium armoured cable of standard make. | 1 | job | 50,000 ₹50,000 Lowest |
| 10.00 | Providing and Installation of MCCB 250A-4 Pole 50 Ka breaking circuit capacity with cover of standard make with i.e. Havells, L&T enclosed in a weatherproof box for outdoor use for Connection of incoming connecting cables from the electric sub-station and also connect it to Servo stabilizer/Main electrical panel using aluminium armoured cable of standard make. | 1 | job | 40,000 ₹40,000 Lowest |
Tender Value
₹29.0 L
EMD Value
₹58,000
Closing Date
21 Nov 2025, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
UPGRADATION ALONG WITH ALLIED WORKS AT PATHOLOGY DEPARTMENT OF GOVT. MEDICAL COLLEGE, JAMMU BY WAY OF SITC OF AIR CONDITIONERS.
2025_PWDJK_293949_1
MHDJ/e-NIT 247 of 2025-26
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
30 days
GMCH JAMMU
as per e nit
2 documents required · 2 mandatory
₹1,000
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹58,000
10 Dec 2025
1 Nov 2025
22 Nov 2025
1 Nov 2025
21 Nov 2025
5 Nov 2025
1 Nov 2025 - 11 Nov 2025
Amount
SITC of 2.0 TR window air conditioner to be installed at various section of Pathology Department of GMC, Jammu with all accessories (along with outdoor stand and drain pipe) having below give specifications: Air Conditioning Technology: Inverter Min. Star Rating: 3 Max. Cooling Capacity >= 21000 BTU/hr Air Flow Volume(High) >= 465 CFM Ambient upper temperature range >= 52 degree Celsius Refrigerant: Ecofriendly Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges. Make: O-General/Bluestar/Hitachi/Diakin/carrier.
SITC of 2.0 TR Split air conditioner (Hot and Cold) to be installed at HOD room of Pathology Department of GMC, Jammu with all accessories (along with outdoor stand and drain pipe) having below give specifications: Air Conditioning Technology: Inverter Min. Star Rating: 3 Max. Cooling Capacity >= 21838 BTU/hr Air Flow Volume(High) >= 703 CFM Ambient upper temperature range >= 52 degree Celsius Refrigerant: Ecofriendly Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges. Make: O-General/Bluestar/Hitachi/Diakin/carrier.
SITC of 2.0 TR Split air conditioner to be installed at various section of Pathology Department of GMC, Jammu with all accessories (along with outdoor stand and drain pipe) having below give specifications: Air Conditioning Technology: Inverter Min. Star Rating: 3 Max. Cooling Capacity >= 21495 BTU/hr Air Flow Volume(High) >= 554 CFM Ambient upper temperature range >= 52 degree Celsius Refrigerant: Ecofriendly Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges. Make: O-General/Bluestar/Hitachi/Diakin/carrier.
Supply, Installation, Testing and Commissioning of 5KVA copper wound automatic wall mounted voltage stabilizer input Voltage 130-280 V & of superior quality ISI mark for ACs. Make: Microtek/Aulten/Servokon/Electricfield
Providing and fitting of SPN of 32 Amp of standard make i.e. Havells, L&T/ABB with Gang box (complete with fittings) for, 1.5TR Capacity ACs to be installed.
Providing and fitting of extra copper pipe with insulation.
Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of interconnecting stabilizers, digital timer panel and electrical panel . Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning units (Outer & Inner) to the Stabilizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and Installation of Heavy Duty Main Electrical Panel (Powder Coated)-250A which includes MCCB 250A-4 Pole, 50 Ka breaking circuit capacity of standard make i.e. Havells, L&T of size 3’×3’6”×15” along with spread links and 04 nos .buss bar of capacity 250A each along with holes for thimbling of the cable with nut bolt arrangement as per site requirement for Connection of incoming cable connecting using aluminium armoured cable of standard make.
Providing and Installation of MCCB 250A-4 Pole 50 Ka breaking circuit capacity with cover of standard make with i.e. Havells, L&T enclosed in a weatherproof box for outdoor use for Connection of incoming connecting cables from the electric sub-station and also connect it to Servo stabilizer/Main electrical panel using aluminium armoured cable of standard make.
Providing and laying of 150 mm2 3.5 Core Aluminium armoured cable of standard make i.e. Havells, Polycab from sub-station to main electrical Panel to be installed at Pathology Department.
Providing and fitting of Double door 8 way TPN DB with capacity >= 63A MCCB (incomer) 36 ka BCC along with 04 nos. bus bars of each capacity >= 63A for further distribution of loads. All work carried out as per directions of Engineer in charge.
Wiring for circuit/sub-main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surgace/recessed PVC conduit as required. 4×16 sq. mm + 2×6 sq. mm earth wire
Providing and laying of chemical earthing for the main electric panel of Pathology Department, GMC Jammu by way of excavating of the pit of size 1.0 x 1.0 x 3.0 mtrs deep adjacent to the Pathology Department of GMC Jammu with the help of manual labour and shifting of debris outside municipality limit. Providing and fixing of GI earthing electrode 01 No. 03 mtrs long of 60mm dia in the excavated pit after properly filling of the pit with 2 bags (25kg each) of backfill chemical compound and then filling of the remaining portion of the pit with soil. Providing and fixing of GI strip of size 40 x 6mm wide from electrode to the distribution board panel. The Job also includes cost of material, charges of installation, transportation charges of material to the site, tools and tackles charges, all unforeseen items/jobs required for the completion of job and all kinds of taxes thereof.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
BOQ_950824.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .