Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.8 L+₹2.3 L (20.0%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹14.3 L+₹2.7 L (23.8%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹14.9 L+₹3.4 L (29.5%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹15.4 L+₹3.8 L (33.2%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
13 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHISIANA
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (AF) BHISIANA, PIN-151201
Repair/Replacement/Maint of U/S Security Light alongwith connected Items at 34 Wing AF Stn Bhisiana
2020_MES_343746_1
GE/BHI-15/2020-21
Open Tender
Miscellaneous Works
Item Rate
330 days
GE (AF) BHISIANA
Please Refer Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) BHISIANA
₹60,000
Yes
9 Jul 2020
9 May 2020
15 Jun 2020
9 May 2020
13 Jun 2020
16 May 2020
60 days
Amount
Repair/maint/Replacement of street light/security lights of any type flood lights,post top lanterns or any other external light in its position fixed on pole/high mast/building structure or by taking down to round,if required,testing all the components /parts wiring etc. identifying and replacing the defective components wise choke (ballast) electronic driver,igniter,capactor, lamp,lamp holder,connector,connection wire/cables,MCB etc.including refixing the fixing to its original position (if) taken down including repair/maint of street light control timer, junction box and fixing new street light (item 2, 3, 4, 5 & 6) all as directed by Engr-in-charge for the period of 11 months from the date of commencemnt of the work. Note : The rate against the above mentioned items is deemed for cost of labour and allied expenses only.
Cost of spare choke (ballast) electronic driver, igniter,capacitor, lamp,lamp holder connector replaces against above maintenance item will be measured and paid seperately under respective item of of schedule.
The contractor's representative will report to concerened JE E/M at 0900 hrs daily to collect the list of defective street light fitting one will submit the completion report on the same day before 1730 hrs to JE E/M.
The contractor has to rectify the defects/reports and make the street light servicable with in 24 hours from time the list of defective street lights is handed over to him/her rep by the concerened JE E/M.In case the street light is not made functional for whatsever reason with in the specified time line,an amount of Rs. 50per such defective street light per day will recovered from the amount due to him through RAR /Final Bill.The contractor shall be carry out repair/maint will simentanously both domestic & tech area by engaging seperate team of electrician/technician in order to ensure properly & timely rectification of defects.
The contractor shall maintain sufficient stock of spares/materials required for repair/maint of street light with the concerened JE E/M. Note : Vehicle and T&Pwill be arrange by the contractor.
The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipments and clothing to his men and department shall not be responsible for any mishappening/accident/injuryto his men.
Supply only 90 W LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources.LED luminous efficiency should be > 90Lm/w.It should have active power factor correctio (APFC) electronic gear (electronic driver).Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission.It shall have epoxy powder coated grey finish phosphochromate treatment,IP-66 protection class I operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz.fitting should be suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5sqmm with OH line or PVC junction box complete all as directed at site.
Supply only 60 W LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources.LED luminous efficiency should be > 60Lm/w.It should have active power factor correctio (APFC) electronic gear (electronic driver).Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission.It shall have epoxy powder coated grey finish phosphochromate treatment,IP-66 protection class I operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz.fitting should be suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5sqmm with OH line or PVC junction box complete all as specified and directed by Engr-in-charge
Supply and fix 45 W LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources.LED luminous efficiency should be > 45Lm/w.It should have active power factor correctio (APFC) electronic gear (electronic driver).Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission.It shall have epoxy powder coated grey finish phosphochromate treatment,IP-66 protection class I operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz.fitting should be suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5sqmm with OH line or PVC junction box complete all as specified and directed by Engr-in-charge
Supply only 200 watt LED Flood light luminaire of epoxy powder cated CRCA MS housing with epoxy powder coated aluminium heat sink with system wattage .with 120 degree view angle,>200 lumen/watt,luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as directed at site.
Supply only 150 watt LED Flood light luminaire of epoxy powder cated CRCA MS housing with epoxy powder coated aluminium heat sink with system wattage .with 120 degree view angle,>200 lumen/watt,luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as directed at site.
Supply only LED active power factor correction (APFC) electronic gear (electronic driver) suitable for 90 watt LED light fitting complete all as directed by Engr-in-Charge.
Supply only LED active power factor correction (APFC) electronic gear (electronic driver) suitable for 60 watt LED light fitting complete all as directed by Engr-in-Charge.
Supply only LED active power factor correction (APFC) electronic gear (electronic driver) suitable for 45 watt LED light fitting complete all as directed by Engr-in-Charge.
Supply only street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc
Supply only street light GI pipe bracket 25mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed at site
Supply and fixing digital street light timer prewired switch for automatic switching of street light.THE TIMER SWITCH alongwith power contactor of capacity 65Amps 3 pole /230 volts,nuts bolts for fixing of timer with incoming & outgoing connections complete all as specified and directed by Engr-in-Charge.
S&F MCBs 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked complete all as specified :
MCB SPN 5 to 40 Amps C series .
MCB SP 5 to 40 Amps C series
Supply and fixing copper conductor flexible cable with PVC insulator multi-stranded 3 core 1.5 sqmm. Complete all as specified at site
Supply , laying , jointing and testing XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sq mm 4 Core with aluminum thimble of same size including taking down complete all as directed.
Supply , laying , jointing and testing XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core with aluminum thimble of same size including taking down complete all as directed.
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on plan and getting out in soft/loose soil.
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm as directed.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point
M&L for providing Fazilka river sand as in sand cushioning to under ground cable including punning down of sand in layers as specified and as directed (Note : Punned thickness shall be measured and paid)
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified
Material and labour for preparation of old steel surfaces and applying alternatively in yellow and black one coat of synthetic enamel black paint to steel tabular, pole upto 1 mtr height from ground level and remaining with two coats aluminium paint to LT pole including numbering of pole with black paint complete as specified
Supply and fix PVC Sintex Box (200mm x 250mm) having 04 Nos of aluminium bus bar mounted on insulator with the help of nut,bolts, clamps including single pole MCB of 6 amps, 2.5 sqmm copper conductors cable 3 core for connection of incoming and outgoing cables complete all as specified and directed by Engineer-in charge
GUPTA AND ENGINEERS
Aman Enterprises
Rasvinderpalandco
swarn singh and co.
M/s RAMESH KUMAR VERMA CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .