Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹10.0 L+₹26,865.09 (2.77%)Rejected-Finance G 2 BIDHAN NAGAR P O MIDNAPUR P S KOTWALI DIST PASCHIM MEDINIPUR PIN 721101 | MIDNAPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹10.5 L+₹76,130.09 (7.85%)Rejected-Finance | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹10.8 L+₹1.1 L (11.1%)Rejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L4 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹19,960
Closing Date
13 Aug 2024, 1:00 pmClosed
Office of the Executive Engineer Purba Medinipur
Office of the Executive Engineer Purba Medinipur Electrical Division P.W.D.
EI work including SITC of DG set, AC Machine and online UPS of Proposed 10 Beded Dialysis Unit at Tamralipta Govt. Medical college and Hospital, Purba Medinipur
2024_WBPWD_724939_1
WBPWD/EE/PMED/NIQ-30/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
tamluk
Please refer Tender documents.
3 documents required · 3 mandatory
₹19,960
Tamluk
20 Aug 2024
30 Jul 2024
16 Aug 2024
30 Jul 2024
13 Aug 2024
6 Aug 2024
5 Aug 2024
Amount
Supplying and fixing 415V, 125A TPN SFU with sheet steel enclosure on flat iron iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type 125A HRC fuse.(Make - L&T/Seimens)
Supplying and fixing 415V, 63A TPN SFU with sheet steel enclosure on flat iron iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type 63A HRC fuse.(Make - L&T/Seimens)[ for RO Plant](
S & F 415V, 200A, 1m long sheet metal (16 SWG) Copper(4x20x5mm) Busbar chambers on flat iron frame on wall, incl. earthing attachment and painting as required as per GS.And Supplying and fixing 440V, 3Phase Voltmeter ( L&T make cat. 132010OOOO)- 1no., 3phase Ammeter(L&T make cat. 131010OOOO) -1no., CT (Kappa make class-I) - 3nos. and LED Indicating Lamp(Red,Yellow and Blue) -3nos. on top cover of busbar including interconnection. [
Supplying and fixing 415V, 125A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc (Make - L&T/HPL)
Supplying and fixing 415 V, 16-32A per way, 8 Way Vertical TPN MCBDB with provision for FP MCCB as incommer and TP MCB as outgoing in suitable enclosure with metal door comprising of the following :- a) 125 A, 35KA, 4 pole MCCB -- 1 No. b) 63A TP 10ka, 'C'- curve MCB --8Nos. c) Cable end box-- 2 nos. (Make-Siemens/ Legrand/ Schneider)D-6/7, D-8/10,D-11/15,D-12/16
Supplying and fixing 415 V, 25-32A per way, 6way TPN MCBDB with SS enclosure double-door with IP-42/43 protection with 63A Four Pole Isolators as incomer and 18 non SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 63A FP Isolator, 18 no. (16-32A) SPMCB. (Make-Siemens/ Legrand/ Schneider)
Supplying and fixing 250 V, 6-10A per way, (2+8)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 40A DP Isolator, 8 no. (6-16A) SPMCB). (Make-Siemens/Legrand/ Schneider )
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles with 1x14 swg continuity wire
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
Supplying and fixing 20 mm size PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS-H' PVC insulated & unsheathed copper wire (Havells/Finolex/RR kable/ Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS-H' PVC insulated & unsheathed copper wire (KEI/Havells/Finolex/RR kable) for ECC, to light/fan/call bell points with Modular type switch (Legrand Myrius/Equivalent Crebtree or L&T/ Brand approved by EIC) fixed on Modular GI switch board complete with 3nos. suitable size “Ph & N” & "E" copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] (Avg. Run 8Mtr.)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS-H' - - do- - do - -, to 6A 3 pin Modular type plug socket & switch (Legrand Myrius/Equivalent Crebtree or L&T/ Brand approved by EIC) On Board
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS-H' - - do- - do - -, to 6A 3 pin Modular type plug socket & switch (Legrand Myrius/Equivalent Crebtree or L&T/ Brand approved by EIC) Avg. run 4.5 mtr
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Legrand Myrius/Equivalent Crebtree or L&T/ Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board complete with 3nos. suitable size “Ph & N” & "E" copper bar with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Legrand Myrius/Equivalent Crebtree or L&T/ Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Wiring in 1.1KV gr. Single core standed FRLS-H PVC insulated & unsheathed copper wire (Havells/Finolex/RR kable) in 19mm bore polythene pipe embedded in wall incl. manding good damages etc.
a) 3 x 22/0.3 (1.5 sqmm)
a) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
b)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
c) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
d) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9(V)]
Supply & fixing 230V, 36W 2'x2' LED recessed luminaries on false ceiling and necessary connection.crompton cat -LCTLRNE-36-FO-CDL/Philips/wipro)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
S & D of single LED Tube light fitting [Make - Crompton cat no. IGP161 LTT8-16] complete with 1x20 Watt Master LED tube lamps Crompton cat no. LTT8-20 or Equivalent of Wipro/Havells/Magic suspended below the ceiling with S&F 2x20mm dia EI conduit up to 25 cm long with 'L' type MS clamp and making connection as to
S & F 9W LED (Philipsor eqivalant Crompton/Magik) on existing Holder point
S & F 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board [G.S. Page D13 Item - 20(a)]
S & F following .9" dia heavy duty industrial type exhaust fan(EPC) with Al louver shutter heavy gauge to be fixed on wall with necessary cutting of wall etc. and mending good the damages. (EPC)
Supply & Fixing 240 V, 25 A, Modular type starter (Legrand Myrius/Equivalent Crebtree or L&T/ Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand Myrius/Equivalent Crebtree or L&T/ Brand approved by EIC) ), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
175 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
Supply and Fixing 440V,( 63A 3P+N+E-FP ) Industrial Pulg socket incl. S/F 63A FP Isolator (Legrand cat. 5078 64 ) embedded in wall and connection complete. (For UPS IN-OUT)
Supply and fixng 440V , AC Time Controler comprising with one no. Digital Time Switch (Legrand), 2 nos. 63A FP Power contractor (L&T Cat MNX70), 2 nos. Toggle Switch as per rating, 1 no. 63A FP MCB (legrand), 3 nos. LED indicating lamp and necessary P-N connectors in suitable size ss box incl. s/f ss box with locking arrengemnt on wall and necy. conncetion.
S & D of 1.1 KV. Gr. armored XLPE/A Al. LT cable of following rating for connection [Make:RR/Polycab/Havells/KEI] [NS]
4 core X70 sq.mm.
4 core x 50 Sqmm
Laying of 4 core70 sqmm cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of 4 core 70 sqmm cable in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Supplying & fixing medium gauge GI Pipe ( ISI-Medium)Protection with necessary fittings and jointing metarials of 80 mm dia & Laying only Cable 4 core 70 sqmm cable through it (Tata/Jindal)[
Laying of 4 core 50 sqmm Al armoured cable on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting [F-1/2.c]
Supply & Laying of 4 core 25 sqmm AL armoured cableon wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting [PWD/G.S. Page F 1 Item - 2(b) + Cable Price](Cable make - Havells/RR Kable/Polycab)
S & F compression type gland complete with brass gland, brass ring & rubber ring and Finishing the cable ends as to GS of XLPE/PVC armoured cables as below : [ PWD/G.S. Page F 4(Item - 7) & Page F 5
4 Core 70 Sqmm
4 core 50 sqmm
4 core 25 sqmm
Supply & Fixing of 200x50x1.25mm (18SWG) perforated GI cable tray With 25x25x3mm angle iron support with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level (By TATA-Medium GI pipe)[PWD/G.S.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Excavation of soil for installation of Earth Electrode and filling & ramming.(For Soft soil) [
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [
S & F 40mm medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Supply & fixing 18"(450mm) full metal body oscillating wall bracket fan (Make- Orient Tornado Wall-II/Crompton/EPC)
M/S JOGMAYA ENTERPRISE
G B ELECTRICAL
RASH ELECTRICAL WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .