Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.6 L+₹3.8 L (32.3%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹16.0 L+₹4.2 L (35.6%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹16.1 L+₹4.3 L (36.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹17.7 L+₹5.9 L (49.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | Ms Kamal Kant Agarwal L8 | shyam construction L1 | VIJAY ENTERPRISES L6 | M/s RCC L3 | SHYAMA CONSTRUCTION L5 | LOKESH ELECTRICAL L4 | M/S MRS BHASKAR L2 | PRABHAT ENGINEERING SOLUTION AND SERVICES L9 | ASHOK INFRATECH L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out old unserviceable earthing pit of any type soil in any depth complete with connected accessories including necessary excavation, dismantling, breaking PCC chamber, removing old earth electrode, strip/wire of any type/size and returning refilling of excavated soil at working site complete all as specified and directed. | 334 | Each Set | 200 ₹66,800 | 10 ₹3,340 Lowest | 100 ₹33,400 | 50 ₹16,700 | 80 ₹26,720 | 50 ₹16,700 | 29 ₹9,686 | 25 ₹8,350 | 200 ₹66,800 |
| 2.00 | M&L for earthing complete with galvanised steel earth plate 600 mm x 600 mm x6.3 mm thick elecrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 15 cm on all sides of electrode as specified and connected to GI wire of dia 4 mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil,
Cont/- | 144 | Each Set | 3,000 ₹4,32,000 | 2,250 ₹3,24,000 Lowest | 4,000 ₹5,76,000 | 2,800 ₹4,03,200 | 3,000 ₹4,32,000 | 3,300 ₹4,75,200 | 2,600 ₹3,74,400 | 5,000 ₹7,20,000 | 4,000 ₹5,76,000 |
| 2.01Cont/-- returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, precast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 20mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. | ||||||||||||
| 3.00 | M&L for earthing complete with galvanised steel earth plate 600 mm x 600 mm x 6.3 mm thick elecrode and 32 mm x 6 mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 150 mm on all sides of electrode as specified and connected to GI strip 32 mm x 6 mm as earth lead by means of bolts, nuts, check nuts and
Cont/- | 135 | Each Set | 3,500 ₹4,72,500 | 2,250 ₹3,03,750 Lowest | 4,500 ₹6,07,500 | 2,800 ₹3,78,000 | 3,300 ₹4,45,500 | 3,000 ₹4,05,000 | 2,700 ₹3,64,500 | 5,000 ₹6,75,000 | 4,500 ₹6,07,500 |
| 3.01Cont/- washers (including welding) of galvanised iron or steel and connected to main switch board / LT panel/ test point/equipment at the other including necessary excavation of earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20 mm bore GI tubing medium grade for watering and 40 mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. | ||||||||||||
| 4.00 | M&L for earthing complete with pure copper earth plate 600 mm x 600 mm x 3.15 mm thick elecrode and 25 mm x 4 mm pure copper strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 15 cm on all sides of electrode as specified and connected to copper strip 25 mm x 4 mm as earth lead by means of tinned copper/ brass bolts, nuts, check nuts and washers (including brazing) and connected to main
Cont/- | 55 | Each Set | 15,000 ₹8,25,000 | 8,000 ₹4,40,000 | 10,500 ₹5,77,500 | 10,000 ₹5,50,000 | 11,000 ₹6,05,000 | 7,000 ₹3,85,000 Lowest | 9,900 ₹5,44,500 | 15,000 ₹8,25,000 | 8,000 ₹4,40,000 |
| 4.01Cont/- switch board / LT panel/ test point/sensitive equipment at the other including necessary excavation of earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20 mm bore GI tubing medium grade for watering and 40 mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. | ||||||||||||
| 5.00 | M&L for dismantling tilted/broken PCC earth pit chamber and making new PCC earth pit chamber of size as per electrical plate No. 3 of SSR-2009 Part-I with PCC (1:2:4) type B1 with pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel including excavation and earth work as required at site complete all as specified and directed. | 80 | Each | 100 ₹8,000 Lowest | 200 ₹16,000 | 300 ₹24,000 | 250 ₹20,000 | 250 ₹20,000 | 1,200 ₹96,000 | 350 ₹28,000 | 400 ₹32,000 | 150 ₹12,000 |
| 6.00 | Supply and fixing GI tubing 40 mm bore (medium grade) in trenches/ floor/ roof/ wall with proper size of clamp, nuts and bolts for earth strip protection/ lightning conductors/ arrestor complete all as specified and directed. | 100 | RM | 300 ₹30,000 | 120 ₹12,000 Lowest | 200 ₹20,000 | 150 ₹15,000 | 350 ₹35,000 | 190 ₹19,000 | 349 ₹34,900 | 300 ₹30,000 | 500 ₹50,000 |
| 7.00 | Supply and fixing GI tubing 20 mm bore (medium grade) in trenches/ floor/ roof/ wall with proper size of clamp, nuts and bolts for earth strip protection/ lightning conductors/ arrestor complete all as specified and directed. | 100 | RM | 200 ₹20,000 | 95 ₹9,500 Lowest | 130 ₹13,000 | 110 ₹11,000 | 180 ₹18,000 | 120 ₹12,000 | 190 ₹19,000 | 135 ₹13,500 | 100 ₹10,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Aug 2025, 6:00 pmClosed
Maj Sarith E
GE (WEST) MATHURA
REPAIR MAINT OF EARTHING LIGHTENING ARRESTER AND ALLIED ITEMS UNDER GE W MATHURA
2025_MES_722652_1
8300/1317/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (WEST) MATHURA
AS PER NIT
10 documents required · 10 mandatory
₹500
GE (WEST) MATHURA
₹50,000
Yes
23 Sept 2025
25 Jul 2025
22 Aug 2025
25 Jul 2025
15 Aug 2025
8 Aug 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .