| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.9 CrAccepted-AOC RGTPP KHEDAR HISAR HARYANA | HISAR | HARYANA | 125001 | ₹3.9 Cr | 1 | Accepted-AOC DUE TO LOWER SIDE |
| 2 | 2₹4.3 Cr+₹38.0 L (9.76%)Rejected-AOC | ₹4.3 Cr+₹38.0 L (9.76%) | 2 | Rejected-AOC DUE TO HIGHER SIDE |
| 3 | 3₹4.3 Cr+₹39.7 L (10.2%)Rejected-AOC 2 HOUSE NO 214 FRIENDS COLONY RAJIV NAGAR MANDI DABWALI 125104 | MANDI DABWALI | SIRSA | HARYANA | 125104 | ₹4.3 Cr+₹39.7 L (10.2%) | 3 | Rejected-AOC DUE TO HIGHER SIDE |
| 4 | 4₹4.3 Cr+₹43.3 L (11.1%)Rejected-AOC 308 MANDI ROAD BARWALA 125121 | HISAR | HARYANA | 125121 | ₹4.3 Cr+₹43.3 L (11.1%) | 4 | Rejected-AOC DUE TO HIGHER SIDE |
| 5 | 5₹4.6 Cr+₹73.2 L (18.8%)Rejected-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹4.6 Cr+₹73.2 L (18.8%) | 5 | Rejected-AOC DUE TO HIGHER SIDE |
Tender Value
₹4.1 Cr
EMD Value
₹8.1 L
Closing Date
9 Mar 2022, 2:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PUBLIC HEALTH ENGINEERING DIVISION NO 2 HISAR
Const of RCC NP2 pipe channel 2 No RCC SS Tank Suction Scour well 2 Nos RCC CWT Const of 1 MLD WTP PC SV Houdi B Wall Road Path PL at HWorks PMachinery Disty Sys Repair of existing structures of BS 1and2 OandM for 5 yrs after 1 yr defect liability
2022_HRY_210030_1
3452 dated 25.02.2022
Open Limited
Civil Works
Works
7 days
HISAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹8.1 L
Yes
1 Apr 2022
2 Mar 2022
9 Mar 2022
2 Mar 2022
9 Mar 2022
2 Mar 2022
Amount
Construction of 1.00 MLD Rapid Sand Filtration plant Comprising of Labor For DI Pipe from existing Raw water/ Pump, Inlet Box, Inlet channel, Alum Dozing, Flash Mixing, Tapered Flocculate, Rectangular setting tank, filter box, Over hear reservoir for back wash including pump sets and electric control penal, sluice valve houdi, Di Pipes , Di Specials Manhole Covers, air squer equipment, Chemical house including chlorination equipment and arrangement of flow measurement and sand bed complete in all respect as per DNIt . Labor rate for fixing DI, S/S class K9 ISI marked pipe including cost of DI specials/fitting. ISI marked PN 1.6 sluice valve including cost of excavation, layig, cutting, jointig,threading,and jointing material in horizontal length including connections complete in all respect. From existing raw water tank. NOTE - Di Pie will be supplied by the departmental free of cost ( BASED ON SCADA SYSTEM – 1.00 MLD WTP)
Supply & Erection of Horizontal spindle split casing type pumping sets of minimum Four (4) Star rating duties directly coupled to AC squirrel cage induction type motor with 1440 RPM, 3 phase, 50 Hz and accessories as described in Schedule No. II complete in all respect with priming arrangement and complete base frame as per IS marked complete in all respect A) Raw Water Pump 1100 LPM, 12.00 Mtrs. Head 10.00 BHP
Supply, erection, testing and commissioning of Wall mounted electrical panel board. fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated e deep having following items : approximate size 500 x 1200mm and 400mm deep having following accessories comlete in all respect as per approved NIT a) Incomer switch 200 amp b) Aluminum bus bar chamber of 300 Amp. Capacity c) Volt meter 100 x 100mm range 0 to 500 volt 2 No.(AE/KAPPA/L&T) d) Including Lamp-One set
Supply, erection, testing and commissioning of Wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900mm and 400mm deep having following items : A) For Raw water pump sets for 1100 Lpm x 12 M head = 2 No. AT WIW a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1 No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g)motor starter, star dela, 2 No. for 1100 LPM x12M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable capacity 2 Nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
B) For Clear water pump sets for 2200 Lpm x 40 M head = 2 No. AT WIW a) Main switch 100 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 2 No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 2 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motor starter, star dela, No. for 2200 LPM x40 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 100 Amp = 1 No )
C) For Clear water pump sets for 500 Lpm x 25 M head = 2 No. for B/Stn. 1 at W/W a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motor starter, star dela, 2 No. for 500 LPM x25 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
D) For Clear water pump sets for 500 Lpm x 30 M head = 2 No. at B/Stn. 1 a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motor starter, star dela, 2 No. for 500 LPM x30 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
E) For Clear water pump sets for 900 Lpm x 25 M head = 2 No. for B/Stn. 2 at W/W a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motor starter, star dela, 2 No. for 900 LPM x25 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
F) For Clear water pump sets for 900 Lpm x 30 M head = 2 No. at B/Stn. a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motor starter, star dela, 2 No. for 900 LPM x30 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
Supply erection, testing of ISI marked Copper wire for 4 Nos motor with under ground system in PVC and Flexible Pipes Copper wire complete in all respects with accessories like thimble ete, complete in respects. 6 Sq mm 3 Core
10 Sq mm 3 Core
16 Sq mm 3 Core
Supply erection, testing of light fittings ineluding wire in the Pump Chamber with material upto 10 points including switch, button, plug. PVC conduit pipe & copper wire etc. as per approved specifications complete in respect
Supply erection, testing of reputed make LED light 100 watts with fittings and accessories complete in respects.
Operation and mantenence of WTP complete scope of work ( Distiction Material Supplied by the PHED) as per schedule - iv for a period of 5 year after 12 months during defect liability period and 3 months trial run period ( wil be charged to a/mtc. estimate. Complete in all respect Operation and mantenence during defect liability period ( Operation Only ) after 3 months trial run period
For 1st Year Operation and Maintenance after defect liability period
For 2nd Year Operation and Maintenance after defect liability period
For 3rd Year Operation and Maintenance after defect liability period
For 4th Year Operation and Maintenance after defect liability period
For 5th Year Operation and Maintenance after defect liability period
Bidder Name
Amount
RAM PHAL SINGH CONT(GSTN-NA)
NAFE SINGH CONTRACTOR(GSTN-NA)
ROHTASH KUMAR CONTRACTOR(GSTN-NA)
Vinod Kumar Contractor(GSTN-NA)
M/s Sourabh Construction Pvt. Ltd.(GSTN-NA)
RAM PHAL SINGH CONT
NAFE SINGH CONTRACTOR
ROHTASH KUMAR CONTRACTOR
Vinod Kumar Contractor
Vinod Kumar Contractor
RAM PHAL SINGH CONT
M/s Sourabh Construction Pvt. Ltd.
ROHTASH KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .