Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC 20 A 2ND FLOOR BLOCK C RAJEEV NAGAR BEGUMPUR DELHI 110086 | NORTH WEST | DELHI | 110086 | L1 | Accepted-AOC Lowest BIdder | |
| 2 | L2₹37.4 L+₹1.6 L (4.43%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹44.3 L+₹8.5 L (23.7%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹97,600
Closing Date
21 Dec 2023, 6:00 pmClosed
GE NASIRABAD
Garrison Engineer, Military Engineer Services, Nasirabad, Pin 305601
PROVN OF TOILET BLOCK CONSISTING OF TEN LATRINES WC FOUR BATHROOM AND TWO WASH HAND BASINS, PROVN OF TOILET BLOCK IN OR LINE AREA OF OMC, SECURITY FENCING 300 MTRS BEHIND OR LINE BLDG NO. 3 OF SATA REGT AND CERTAIN MINOR WORK UNDER AGE BR II AT GE NA
2023_MES_629630_1
8385/E8
Open Tender
Civil Works
Item Rate
183 days
GE Nasirabad
MES Contractor enlisted as Class D and above and category a i having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
Yes
₹97,600
Yes
9 Jan 2024
23 Nov 2023
23 Dec 2023
23 Nov 2023
21 Dec 2023
7 Dec 2023
23 Nov 2023 - 7 Dec 2023
Amount
Surface dressing n exc 15 cm deep in soft/loose soil complete, all as specified and directed.
M&L for PCC 1:4:8 type D-2, with 40 mm graded stone aggregate as in foundation and mass concrete complete all as specified and directed.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for mild steel TMT bars of 6mm to 8mm dia and over, in stirrups , spacers and boinders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for mild steel round bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for RCC M-25 grade (design mix) using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams , and similar work, vertical or to batter, flat surfaces of concrete , surface is required to be fair finished complete all as specified and as directed by the Engineer-in-Charge
M & L for M-25 grade (design mix) using 20mm graded aggregates as in columns, pillars, piers, posts and struts complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, rectangular or polygonal surfaces of concrete , surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge
M & L for RCC M-25 (design mix) using 20mm graded aggregates as in roof beams, lintel beams/bands, cantilevers, bressummers, lintels over 1.5m span, chajjas etc complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, soffits of lintel beams/ bands, chajjas, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., flat surfaces of concrete ,surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge
M & L for RCC M-25 (design mix) using 20mm graded aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), flat surfaces of concrete , surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, as roughed finished surface of concrete complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound @ 3 % by weight of cement on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement, complete all as specified and directed (WPC measured and paid separately) complete all as specified and directed.
M & L for preparing new surfaces (at plastered/ rough cast plastered) of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
M & L for brocken stone boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Supply only liquid water proofingcomplete all as specified and directed. Make : Fosroc Conplast/Sika
M & L for Non-skid Ceramic coloured tiles 7 to 8 mm thick ( square /Rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured in white or coloured cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6), over 25 mm thick PCC type 1:2:4 type B-0 using 12.5mm graded stone/aggregates as in base concrete to floor finish, complete all as specified and directed.
M&L for glazed ceramic coloured tiles 7 to 8mm thick, area of tile exc 0.11 sqm but n.exc 0.18 sqm, on vertical surfaces of wall such as skirting/ dados ect set and jonted in neat cement slurry and pointed in white cement to match the shade the tiles over and including 10mm thick screed plaster on stone/brick masonry walls in CM 1:4 complete all as specified and directed.
M & L for Non-skid Ceramic coloured tiles 7 to 8 mm thick ( square /Rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured in white or coloured cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6) complete all as specified and directed.
M&L for 25mm thcik PCC (1:2:4) type B-0, using 12.5mm garded aggregates as in base concrete to floor finish all as specified and directed.
Demolition of stone/ brick masonry built in cement or cement lime mortar as in portion ordered and directed.
M & L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge
M&L for brick work with fly ash old size bricks,straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) complete all as specified and directed.
Supply and fixing in repairs Squatting pattern Water closet, Orissa pattern of vitreous china Size 580x440mm wide with integral foor rest etc complete all as specified and directed.
S&F vitreous china wash down water closet pedestal pattern pan white with trap including connection to existing out joint pipe, flushing pipe or Cistern, antisyphonage pipe, including making, etc complete including making good to floor etc complete all as specified and as directed.
S & F Toilet paper holder with flat recessed type stainless steel complete all as specified and as directed.
S&F health faucet cast copper alloy chromium plated with flexible chrome hose and wall hooks complete. Make :-Jaguar ALD 573 or parryware T9941A1
S&F vitreous china white wash basins, including waste pipe, brackets, and connecting pipe Table top basin Kerovit Mazer KB1086 or equivalent complete all as specified and directed.
S&F vitreous china wash hand basin white flat, back of size 550mm x 400mm including 32mm waste coupling and PVC waste down pipe and bracket complete all as specified and directed.
S&F vitreous china urinal half stall type incl connecting pipe, spreader, flushing valve and flush/waste pipe fixed to wall complete. Make : Parryware C0580 with C8123 or Jaguar URS WHT 132530
S&F PVC valve less syphonic action type, low level flushing cistern, 10 Ltrs capacity . White, with inlet ball valve, float and handle & flush pipe, fixed on walls by drilling holes and using PVC rawl plug of suitable size complete all as specified and directed.
S & F 15mm bore, 450mm long PVC connections with two nos CP nuts complete all as specified and as directed by the Engineer-in-Charge
S & F chromium plated Soap dish, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge.
S&F tubular towel rail brass chromium plated 20mm dia 'D' type 60cm long between flanges complete all as specified and directed.
S&F tubular towel rail aluminium anodised 20mm dia 'D' type 60cm long between flanges complete all as specified and directed.
S&F stop/angle valve 15mm bore cast copper alloy, chromium plated, fancy type with long crutch or butterfly handle screwed down high pressure screwed both ends for iron pipe complete all as specified & directed.
S&F 15mm bore angle valve/stop valves fancy type, chromium plated cast copper alloy,with long shank and cap (Concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions fixed complete all as specified and directed
S&F pillar tap,15mm bore, cast copper alloy, chromium plated, fancy type, screwed down high pressure with or without lettred hot or cold with long screw shanks and fly nuts screwed for iron pipe complete all as specified and directed
S & F 15mm bore brass cast copper alloy chlromium plated mixer valve wall or wash basin mixer for mixing hot and cold water with crutch handle screwed down for iron pipe and fixed complete all as specified and directed.
S&F Chromium plated 15mm bore bib taps of PTMT any colour , with capstan heads, screwed down for iron pipe or for brass ferrule & fixed complete all as specified & directed.
Supply and fixing in CP brass shower rose (4'' overhead ABS) with 225mm CP brass arm and flange complete all as specified. Make :- Prayag Cat No. BOS-87
S&F sheet glass shelf assembly consisting of 5.5mm thick 120mm wide with chromium plated brackets guard and railing, 60cm long complete all as specified and directed.
S&F 15mm bore, water tubing, medium grade, galvanised with all fittings and fixed to walls, ceiling or laid in floors / trenches complete all as specified and directed.
S&F 20mm bore, water tubing, medium grade, galvanised with all fittings and fixed to walls, ceiling or laid in floors / trenches complete all as specified and directed.
S&F 25mm bore, water tubing, medium grade, galvanised with all fittings and fixed to walls, ceiling or laid in floors / trenches complete all as specified and directed.
S&F PVC(SWR) Floor trap 75 mm outlet,with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as spd and directed.
S&F solid PVC moulded door frame of size 50mm x 47mm made out of 5mm prelam coloured PVC sheet uses instead of plain colour PVC sheet & edges will be painted to match with prelam sheet as reinforced with MS square tube and fixing in opening as specification & drawing complete all as specified and directed.
Supply and fixing of 30mm thick factory made solid panel PVC door shutter (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded. sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement, complete all as specified and directed.
Supply and fixing of 30mm thick factory made solid panel PVC skelton door shutter (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain, wire gauzed i.e. panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be elded to M.S. tubes. The wire gauge shall be stretched to tighten firmly PVC sheet for top rail, lock rail & bottom rail on either side and joined together with solvent cement, complete all as specified and directed.
S & F Solid PVC Double door frame of size 50mm x 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, supply & fixing in opening as per specification & drawing complete all as specified and directed.
S & F Steel window/ventilator factory made, made out of MS hollow section 79mm x 39mmx1.6mm thick frame with double shutter (glazed & wiregauged shutters) made out of Z section using flush butt welding and tennon riveting all as per IS 1038/83, dobby hinges shall be provided to both shutters, Locking arrangements as per sample approval by GE, provided with knob, 10mm MS square bars in grill, Z section handle 100mm size and 150mm long hook & eye welded to frame and shutter, four Nos lugs welded to frame inculding necessary flat iron beading for securing wire gauge etc including holes, cutting holes for hold fast and making good in PCC 1:2:4 type B-1, and plaster with finishes to match the existing surfaces, including 02 coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and directed. Note : Wire mesh and sheet glass shall be measured & paid separately under respective items.
S & F aluminium alloy, anodised sliding door bolt, 300mm long, ISI marked, with hasp and staple (bolt type) and fixing bolts and sliding bolt of extruded section or cast aluminium alloy complete all as specified and directed.
S&F 150mm long extrueded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolt of extruded section all as specified and directed.
S&F 300 mm rat tail rod Mild Steel ordianary pattern springs including roller and roller plate complete all as specified and directed.
S&F 100mm butt hinges extruded aluminium alloy with galvanised mild steel hinge and anodised ISI marked and fixed type B-21, complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed tinned or stainless steel wire staple complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth applying two coats of synthetic enamel paint (1st grade) complete all as specified.
S&F 3mm thick plain/figured glass, ordinary quality, 3mm thick fixed with oil putty size of glass not exc 0.50 sqm in each pane, complete all as specified and directed.
Supply and fixing 1000 Litre capacity rotational moulded polyethylene water storage tanks ISI Marked (cylindrical vertical with closed top) , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete all as specified and directed.
S&F 20mm ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe of 20mm dia and fixed (minimum weight 210 gms) complete all as specified and directed.
S&F gun metal globe or gate valve, wheel head cast copper alloy screwed down light pressure with crutch or butterfly handle screwed both ends for iron pipe or for union 25 mm dia, ISI marked complete all as specified and directed.
S&F gun metal globe or gate valve, wheel head cast copper alloy screwed down light pressure with crutch or butterfly handle screwed both ends for iron pipe or for union 20 mm dia, ISI marked complete all as specified and directed.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and fixed to wall with clamps complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and fixed to wall with clamps complete all as specified and as directed by the Engineer-in-Charge
S & F for 110mm bore PVC (SWR) junction single (Single T) equal or unequal with oval access door, complete all as specified and directed.
S & F 110mm bore PVC (SWR) bends / shoe of any radius with oval access door, complete all as specified
S & F 110mm bore PVC (SWR) vent cowl, complete all as specified
S & F 75mm bore PVC (SWR) bends/shoe of any radius with oval access door, complete all as specified
M & L for MS work for fencing post and struts made from angle iron and flat iron in any section including cutting tops to shape, drilling holes and notching for fixing of wires etc confirming to Fe-290 (Gde E-165) complete all as specified and directed.
S & F in repairs Galvanised 2 strand, steel barbed wire, 2.20mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, includdigng, securing or tying at crossings with and provisiion of galavnised (Zink coating 60 gsm) mild steel wire, staples or steel pins, etc as directed each line wire to measured complete all as specified and directed.
Fixing only chain link fencing including line wire, any mesh, size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed.
Supply only chain link MS zinc coating 60gms as per IS 4826 fencing of any mesh & 3mm dia of wire complete all as specified and directed. Note :- This item shall be measured and paid as per actual weight or standard weight as per SSR which ever is less.
M & L 5 to 10mm dia mild steel screw bolts (Machine made) with hexagonal or square head at one end and screwed the other or screwed both ends each screwed and to be bolted with washers and one hexagonal or square not exc 50mm long and dia of shank 5 to 10mm including fixed with welding to angle complete all as specified and directed.
M & L for preparation of newly plastered surfaces of Ceiling & applying three coat of white wash complete all as specified and directed
M & L for preparation of newly plastered surfaces of walls & applying three coat of white wash complete all as specified and directed
M & L for 40 mm thick sand stone slab set and jointed in CM 1:4 as in base of water tank and M&L 25mm thick PCC 1:2:4 type B-0 (using 12.5mm crushed stone aggregate) finished concrete surface even and smooth complete all as specified and directed
M & L for 5 CM thick Sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified and directed.
S&F mild steel framed work such as grills, grating cooler stands, etc, with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
For Non-Acessable Roof:- M&L for provn of water proofing roof treatment to RCC roof with APP modifed plain membrane, thickness of membrane not less than 3 mm and weighing not less than 3 kg/sqm comprising with following (a)The surface of roof, parapet and gutters, drain mouths, etc. over which waterproofing treatment is to be applied shall be cleaned of all foreign matter such as, fungus, moss, dust etc by wire brushing and dusting. For cast iron drain out lets a grove shall be cut around to tuck in the treatment. Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes. chimneystacks, etc. and other similar situation to ease up about corners.incl 10mm thick screed bed in CM 1:4 mix with water proofing compound under Bitumious based Primer conforming to IS: 3384 @ 0.3 Kg/SM to be applied on prepared surface, till the surface is properly impregnated. (c) After the application of approved bituminous primer the water proofing membrane shall be laid on the primed surface by torch application method as per manufacturer's instruction. The overlap while torching shall be 100mm in longitudinal direction and 100mm in transverse direction. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer and seling it with the help of hot trowel. The overlap joints shall be made as a monolithic layer. (d) All joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane. (e)A fillet of PCC (1:2:4) type B-0 of 100x100mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of direction. The membrane should not be taken over at any steep turns and hence all corners/timers should be rounded. Apply two coats of bituminous aluminium paint over APP membrane @ 0.30 Kg/Sqm complete all as per manufacturers instructions. complete all as per manufacturers instructions, after as specified and directed.
M&L cement concrete 1:2:4 using 20mm graded aggregate as in surface channel and drain complete all as specified and directed.
Extra for fair finishes drain or channel 30cm and over in girth in cement concrete using extra cement including forming mounds metred /stopped ends etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cill , steps, parapets and railing upto 60cm in height , coping, kneelers, apex stones, bed plates, and the like including weathering, slightly rounded or chamfered angles and throating as directed complete all as specified and directed.
M & L for rough cast plaster mix with crusted stone (6-10 mm), sand and cement in the ratio 1:1:1 , over 15mm thick rendering in CM 1:4 as in under coat including dubbing coat (if required) complete all as specified and directed.
M&L for rendering in cement mortar (1:6), 10mm thick on other than fair faces of brick work / stone masonary surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 5 mm thick in cement plaster 1:3 as in ceiling surfaces finished even and smooth (without using exta cement) complete all as specified & directed.
Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc.and getting out in any type of soil, complete all as specified & directed.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc.and getting out in hard/dense soil, complete all as specified & directed.
Excavation in post holes (or similar holes) each n.exc 0.5 cum getting out, returning, filling in and ramming earth and removing surplus soil to a distance n.exc 50 m in soft / loose soil complete all as specified and directed.
Returning, fillings in including spreading, levelling, watering and well ramming in layers, n.exc 25cm thick in soil complete all as specified and directed.
Removing of excavated soils, not exc 50mtr and depositing where directed at a level n. exc 1.50mtr above the starting point complete all as specified and directed.
M & L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified & directed.
S&F salt glazed stone ware drain pipes of 150mm bore, grade `A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified.
M&L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in bedding to SGSW drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe all as specified and as directed.
M&L for LLDPE Septic tank designed to carry sewage and sludge water , excavation in any type of soil In PCC 1:4:8 below foundation ,vent shaft ,connection, etc., complete for 30 users, complete, all as specified and directed.
M&L for LLDPE Septic tank designed to carry sewage and sludge water , excavation in any type of soil In PCC 1:4:8 below foundation ,vent shaft ,connection, etc., complete for 10 users, complete, all as specified and directed.
M & L for soakage wells including excavation in any type of soil, foundation in PCC (1:4:8), walls of honey combed fly ash brick masonry with top ring of RCC 1:1.5:3 type A-1 concrete including intercepting chamber and screen chamber made of fly ash brick masonry in CM (1:6), RCC cover slab in1:1.5:3 type A-1 & SFRC MH cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80m dia & 3.0m effective depth all as per drg No. CEBZ/TD/78/2011 sh No 1/2 & 2/2 complete all as specified and directed.
M & L for soakage wells including excavation in any type of soil, foundation in PCC (1:4:8), walls of honey combed fly ash brick masonry with top ring of RCC 1:1.5:3 type A-1 concrete including intercepting chamber and screen chamber made of fly ash brick masonry in CM (1:6), RCC cover slab in1:1.5:3 type A-1 & SFRC MH cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4m dia & 3.0m effective depth all as per drg No. CEBZ/TD/78/2011 sh No 1/2 & 2/2 complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
M & L for 75 mm thick cement concrete type C-2, 1:3:6 using 40mm graded aggregate , as in sub base. complete all as specified and as directed by the Engineer-in-Charge
M&L 100mm thick cement concrete type D-2 1:4:8 (40mm graded stone aggregate ) as in floors / pavings complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment coloured, reflective type of approved quality and vibrated with mechanical vibrator & including 50 mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & directed.
M & L for precast cement concrete (Type B-1, 1:2:4, 20 mm graded aggregate) in landings, cover slabs (for manholes etc.)complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, multi stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box of, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box 1.2 mm thick sheet with bakelite laminated sheet top cover 3 mm thick( Make - Hylem/Anchor) ISI Marked, brass screws and cup washers including 1.5 Sqmm multi stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed for:- Make of wire- Havells/Polycab/Anchor/Finolex. Make of PVC conduit -AKG/Plaza/Kalinga
All as above item no 111.00 here-in-before but One light point/bell point controlled by one, one way 5 Amp SP switch.
All as above item no 111.00 here-in-before but One ceiling fan/exhaust fan point controlled by one, one way switch.
All as above item no 111.00 here-in-before but One 5 pin 5 Amp socket on same board with other switches.
All as per item No. 111.03 here-in-before but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 2.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth complete all specified and directed .
S&F of modular switch 1 way 6/10 Amp 1 module complete all as spd and directed.
S&F of modular switch 1 way 16 Amp 1 module complete all as spd and directed.
S&F of modular socket 6 Amp, 2/3 pin combined 2 module complete all as spd and directed.
S&F of modular socket 6 Amp/16 Amp, 2/3 pin combined 2 module complete all as spd and directed.
S&F Switch piano, flush type, single pole, one way, 6/10 Amps, 240 volt, 50Hz, AC, complete all as specified and as directed by Engr-in-Charge.
S&F switch piano flush type 16 amps, single pole one way 240 volts complete all as speciied and directed by Engr-in-Charge.
S&F socket out let 2 in 1,multipurpose 3 pin 15/16 Amp flush type ISI marked complete all specified and directed .
S&F ceiling rose surface bakelite 3 terminals 63.5 x 17 mm complete all as speciied and directed by engr-in-Charge.
S&F of lamp holder PVC/polycarbonate type with back plate complete all as speciied and directed by Engr-in-Charge. MAKE:-Havells/Anchor/Legrand
S&F LED tube light fitting in acrylic linear tube (1x 20 watt),230V for single LED tube light including 1 x 20 W LED retrofit bar professional CW 6500 K cover channel, bipin holders,LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed.
S&F LED tube light fitting in acrylic linear tube (1x 18 watt), 230V for single LED tube light including 1 x 18 W LED retrofit bar professional CW 6500 K cover channel, bipin holders,LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed.
S&F LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistance complete with driver, lamp and street light bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S & F LED mirror light fitting 1X10W, attractive wall/ ceiling mounted type with mettalic channel and white reflector, suitable for mirror light fittings with complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed by Engr-in-Charge Make Bajaj/Havells/CG
Supply and fixing LED lamp 9/11 watt suitable for 230 volts , 50 Hzs, B-22 base complete all as specified and directed
S & F LED light fitting 1X10W bulkhead luminaires IIP 65 protection including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge Make Bajaj/Havells/CG
Supply and fixing testing and commissioning energy saving street light luminaire 35 watt LED , pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete, IP 66 protection incl connecting with three core copper flexible wire from ceiling rose to connector of light fitting complete all as specified and directed by Engr-in-Charge. Make- Havells Cat Part No ENDURACITYLITEPLAT PLUSSL35WLED757SASYBOPC or equivalent model of Surya/Control& Switchgear/Bajaj
S&F MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-43 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing MCB's including blanking plate complete all as specified and directed. Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
S&F MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-43 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 4 way, 240 volts suitable for housing MCB's including blanking plate complete all as specified and directed. Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
S & F MCB SPN, 240 volt, 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge by Engr-in-Charge. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB 'SP' "C" series for solar water heater as electric backup complete all as specified and directed.
S&F house service bracket hook type complete with 3Mtr long GI pipe 40mm dia medium grade two Nos 900 bracket, MS hook and stay complete all as spd and directed
S & F of MCB SP, 240 volt, 6 Amp to 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge. . Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20mm bore GI med grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in electrical plate No. 3 of SSR Pt-I of 2009 incl dismanteling of old unsv existing earthing and connected to earthing test point all as specified or indicated including testing on completion
supplying and spreading in trenches dry river sand cusioning to underground cable in trenches including spreading, levelling hand punning down complete all as spd and directed. Note : Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Supply and laying including jointing, testing or fixing or passing through pipe, trench or duct commissioning and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade size 10 Sqmm 2 core cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying including jointing, testing or fixing or passing through pipe, trench or duct commissioning and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade size 16 Sqmm 2 core cable complete all as specified and directed by Engineer-in-Charge.
Supply and fixing tubes light grade GI tubing 40 mm dia with all fitting laid in trenches complete all as specified and directed by Engineer-in-Charge.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
S & F MCB TPN, 240 volt, 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S&F exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, RPM 1200 Copper winding of sweep 300mm complete all as specified & directed.
Supply and fixing street light bracket made of 32 mm GI pipe , 1.2 mtr lenght fixed with two nos of clamp , nut and bolts for fixing of street light complete all as specified and directed by Engr-in-Charge.
S&F storage type water heater (Geyser) electrical operated capacity 25 litres, BEE 5 star rated, 240 Volts, input 2 KW , puff insulated fitted with stainless inner cantainer and copper coil of BEE 5 star rating models, max working head of water 25 mtr , fixed to wall with suitable MS tower/ anchor bolts, inlet/ outlet pipes incl PVC connections grouted to wall, mounting bolt, nuts and carrying out testing for proper functioning of all as directed by Engr-In-Charge.
Supply and fixing tubes medium grade GI tubing 50 mm dia with all fitting laid in trenches, fixed on pole/ on wall for cable protection complete all as spd and directed.
M&L Sand/Moorum filling under floors or in foundation including watering, consolidating, well ramming in layers not exceeding 25cm thick complete all as specified and directed.
M/s SUNIL ENTERPRISES
kirtiman traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .