Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.2 L+₹2.8 L (13.2%)Rejected-AOC | L2 | Rejected-AOC Not lowest |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Abohar
Garrison Engineer Abohar PIN-152116
Provn of guard room with toilet facility at Inf Bde Sig Coy and other sanctioned works at Mil Stn Fazilka
2020_MES_381225_1
GE ABH-25/20-21
Open Tender
Civil Works
Item Rate
180 days
Fazilka Mil Stn
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Garrison Engineer Abohar
₹52,000
Yes
17 Dec 2020
26 Sept 2020
6 Nov 2020
26 Sept 2020
4 Nov 2020
19 Oct 2020
60 days
Amount
SCHEDULE 'A' SECTION-I (B&R PORTION)
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in loose / soft soil all as specified and directed by Engineer - in – Charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations etc or manholes, cesspits, pipes and cables etc. not exc 10 Sqm on plan and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers of soft / loose soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge.
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth, in layers not exceeding 25cm, watering, and removing surplus spoil to a distance not exceeding 50m and making good surface all as specified and directed by Engineer - in - Charge.
Spreading and leveling of earth in layers not exceeding 25cm thick and well ramming including watering as required all as specified and directed by Engineer - in - Charge.
Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engineer - in - Charge.
M & L for broken bricks hard core of gauge not exceeding 63mm, deposited, spread leveled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed by Engineer - in - Charge
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation of columns, building pillar, posts, struts, etc. filling and mass concrete all as specified and directed by Engineer – in - Charge.
M & L cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate filling of pressed steel frame and hold fast blocks etc all as specified and directed by Engineer - in - Charge .
M & L pre-cast RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in landing, chajjas, shelves, cover slabs and similar articles of any thickness, size or shape including necessary from work, finishing the concrete surfaces fair and even in cement mortar and setting in cement Mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
M & L RCC 1:2:4, (nominal mix), type B-1using 20mm graded stone aggregates for slabs supported on walls, beams, columns and in shelves, the like all as specified and directed by Engineer - in - Charge .
M & L RCC 1:1½ :3, (nominal mix), Type A-1 using 20mm graded stone aggregates for slabs supported on walls, beams, columns and in shelves, the like all as specified and directed by Engineer - in - Charge .
M & L RCC 1:1½ :3, (nominal mix), Type A-1, using 20mm graded aggregates as in beams, cantilevers, bressummers,, lintels over 1.5mtr clear span etc all as specified and directed by Engineer - in - Charge.
M & L Reinforced cement concrete M-25 design mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed.
M & L Reinforced cement concrete M-25 design mix as in slabs supported on walls, beams, columns and in shelves, the like all as specified and directed by Engineer - in - Charge .
M & L Reinforced cement concrete M-25 design mix as in beams, cantilevers, bressummers, lintels over 1.5mtr clear span etc complete all as specified and directed.
M & L Reinforced cement concrete M-25 design mix as in columns, pillars, piers, posts and struts all as specified and directed by Engineer - in - Charge.
Supply only Integral waterproofing compound all as specified and directed by Engineer - in - Charge.
M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .
M & L brick work with sub class ‘B’ old size burnt fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
M & L 40mm thick damp proof course to horizontal or vertical surface incl necessary formwork, applying evenly a coat of blown type bitumen at the rate of 1.50 kg/sqm and binding with clean dry sand @ 0.05 cum/sqm Polyethene film 50 micron thick, laid on a coat of bitumen primer @ 0.30 to 0.50 kg/sqm completed all as specified and directed by Engineer - in - Charge.
M & L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
M & L form work to soffits of suspended slabs such as roof slab and similar work not exceeding 200mm thick for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge .
Form work to chullah hoods, chajjas, troughs and similar items including edges with rough finished surface of concrete all as specified and directed by Engineer - in - Charge.
Form work to sides and soffits of floor or roof beams, lintels cantilevers, shelves including supports, over hangs and the like for rough finished surfaces complete all as specified and directed by Engineer – in – Charge.
M & L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for fair finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.24 (a) ; supplied and fitted to chowkats all as specified and directed by Engineer - in - Charge .
S & F flush shutter 35mm thick solid core construction with block board core and plywood face panels commercial type on both sides with lipping / frame to match all as specified and directed by Engineer - in - Charge.
Taking down chowkhats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each all as specified and directed by Engineer - in – Charge.
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each and all as specified and directed by Engineer - in - Charge.
Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.0 Sqm each & refixing in same opening all as specified and directed by Engineer - in - Charge .
S&F Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification complete all as specified and as directed by Engineer-in-Charge.
S & F Solid PVC door frame factory made of size 50mmx 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube jointed , supplying and fixing in opening complete all as specified and as directed by Engineer-in-Charge.
S & F stainless steel tower bolt 150 mm long heavy duty all as specified and directed by Engineer - in – Charge .
S & F Aluminium anodised barrel tower bolt of extruded section 150mm long all as specified and directed by Engineer - in - Charge .
S & F Aluminium anodised barrel tower bolt of extruded section 200mm long all as specified and directed by Engineer - in - Charge .
S & F 250mm stainless steel sliding door bolts, plate types, with bright bolt not less than 12mm dia and including minimum of 6 bolts and nuts, four on bolt plate and two on staple complete all as specified and directed by Engineer - in - Charge.
S & F aluminium alloy anodized sliding door bolt with hasp and staple (bolt type) and fixing clips of sheets cast or extruded section and fixing bolts of extruded section or cast aluminium alloy 250mm size all as specified and directed by Engineer - in – Charge .
S & F MS butt hinges, medium weight cold rolled 100mm size all as specified and directed by Engineer - in - Charge .
S & F Butt hinges, 100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-22 all as specified and directed by Engineer - in - Charge .
S & F stainless steel handles of size 150mm heavy duty all as specified and directed by Engineer - in - Charge .
S & F aluminium handle cast type anodised, 125mm long all as specified and directed by Engineer - in - Charge .
S & F drapery curtain rod, mild steel, powder coated 25mm dia with brackets, knobs, end stops etc all as specified and directed by Engineer - in - Charge .
S & F 40mm dia cup board knobs fixed with nuts, screws and washer of mild steel bright finished complete all as specified and as directed by Engineer-in-Charge.
S & F brass chromium plated tubular towel rail 20mm dia “D” type 60 cm long between flanges incldg brackets complete all as specified and directed by Engineer - in - Charge .
S & F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm all as specified and directed by Engineer - in - Charge .
S & F framed work such as grills, grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work for water tanks and similar work conforming to Fe-290 Gde E-165 all as specified and directed by Engineer - in - Charge.
M & L mild steel TMT bars 8 to 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed by Engineer - in - Charge .
All as per Srl item No. 51 here in before but 5mm and over for as in stirrups, spacers and binders all as specified and directed by Engineer - in - Charge.
S & F structural steel in roof trusses Fe 410-W (Gde E- 250 ), quality-A, (framed), trussed, purlins, rails and fastenings and heavy bracket framing including distance pieces, cleats etc all as specified and directed by Engineer - in - Charge.
S & F pressed steel door frames with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, size of frame 125 x 60mm, complete all as specified and directed by Engineer - in - Charge.
S & F pressed steel door frames for cup boards with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, size of frame 75 x 60mm, complete all as specified and directed by Engineer - in - Charge.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engineer - in - Charge.
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engineer - in - Charge.
M & L pre-laminated particle board, 18/19mm thick, interior grade, pre-laminated one side with decorative choice laminations, and other side balancing white lamination fixed with screws to timber frame work complete all as specified and directed by Engineer-in-Charge.
M & L machine cut Kota stone slab flooring 20 – 25mm thick over and including cement screed base 20mm thick in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer - in – Charge.
All as per Srl item No. 58 here in before but for vertical surfaces over screed 10mm thick in cement mortar 1:3 all as specified and directed by Engineer - in - Charge.
M & L 18-20mm thick Granite(of any type) tiles machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, rubbing and polishing laid over and including screed 10mm thick in cement mortar 1:3 all as specified and directed by Engineer - in - Charge.
M & L for 50mm thick cement concrete type C-1 (1:3:6) using 20mm graded stone aggregate as in plinth protection etc finished even and smooth without using extra cement all as specified and directed by Engineer - in - Charge.
M & L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge.
M & L 40 mm thick Cement Concrete 1:2:4 type B–1 using 20mm graded stone aggregates flooring finished even and smooth without using extra cement all as specified and directed by Engineer - in – Charge .
M & L 25 mm thick Cement Concrete 1:2:4 type B–0 using 12.5mm graded stone aggregates flooring finished even and rough to receive topping layer all as specified and directed by Engineer - in – Charge .
S & F glass dividing strips, 3mm thick, 38mm width and inserted in position to conform to design all as specified and directed by Engineer - in - Charge.
M & L for glazed ceramic coloured tiles 7mm thick 300 x 200mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to tile shade over and including 10mm thick cement sand plaster (1:3) complete all as specified and directed by Engineer - in - Charge.
M & L for glazed ceramic coloured tiles 7mm thick 450X 300 mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick cement sand plaster (1:3) complete all as specified and directed by Engineer - in - Charge.
M & L for non skid ceramic coloured tiles with matt finish, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:4) complete all as specified and directed by Engineer - in - Charge.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow "P" section of size 60mm x 25mm single rebated comprises guaged skeleton shutter ERW Section 50mm x 20mm and 1mm thick with two open able leaf consisting two Nos. of sash bars of flat iron 12mm x 3mm complete welded to frame with one vertical mullion of ERW box type "T" section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:2:4) type B-1, four Nos. for each window including following fittings welded to the frame shutter complete all as specified and directed by Engineer-in-Charge :- (a) Hold fast 150mm long of 12mm x 3mm made to shape - 04 Nos. per window. (b) Handle of "Z" section 20mm x 25mm, 100mm long - 01 No. per leaf. (c) MS tower bolt 150mm long - 02 Nos. per leaf. (d) MS pintol hinges of size 100mm x 14mm - 02 Nos per leaf. (e) "Z" section 20mm x 25mm x 100mm long stopper - Per leaf. Note : Wire mesh and painting shall be measured and paid separately under appropriate items of BOQ.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow "P" section of size 60mm x 25mm single rebated comprises glazed skelton shutter ERW section 50mm x 20mm and 1mm thick with two open able leaf consisting two Nos. of sash bars of flat iron 12mm x 3mm complete welded to frame with one vertical mullion of ERW box type "T" section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:2:4) type B-1 four Nos. for each window including following fittings welded to the frame shutter complete all as specified and directed by Engineer-in-Charge :- (a) Hold fast 150mm long of 12mm x 3mm made to shape - 04 Nos per window. (b) Handle of "Z" section 20mm x 25mm, 100mm long - 01 No. per leaf. (c) MS tower bolt 150mm long - 02 Nos. per leaf. (d) MS pintol hinges of size 100mm x 14mm - 02 Nos. per leaf. Note : Glass and painting shall be measured and paid separately under appropriate items of BOQ.
S&F in repairs, steel ventilators fixed type 1.25mm thick Box Type (Primer Coat) ERW hollow "P" section of size 60mm x 25mm single rebated optional full glass or wire mesh complete all as specified and directed by Engineer-in-Charge. Note : Glass, wire mesh and painting shall be measured and paid separately under appropriate items of BOQ
M & L for chequered cement concrete designer prepolished glossy finished tiles 25cm x 25cm x 25mm thick with grey cement and pigments, heavy duty, set jointed and pointed in neat cement slurry and pigments as in floors over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
Dismantling floor or wall tiles including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer - in – Charge.
M & L 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
M & L 10mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
Taking down cement plaster/ terrazo finish on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified and directed by Engineer - in - Charge.
M & L one coat of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .
M & L three coats of white wash including preparing new plastered or unplastered surfaces of walls complete all as specified and directed by Engineer - in - Charge.
M & L one coat of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .
M & L three coats of white wash including preparing new plastered or unplastered surfaces of ceiling complete all as specified and directed by Engineer - in - Charge.
M & L two coats of distemper oil emulsion on old decorated plastered surfaces of walls including preparation of surfaces by washing, rubbing down and stopping of distempered surfaces complete all as specified and directed by Engineer - in - Charge .
M & L two coats of distemper oil emulsion over chalk whiting, preparatory to distempering, on newly plastered surfaces of walls including preparation of surfaces all as specified and directed by Engineer - in - Charge.
M & L applying two coat of cement base paint on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in – Charge
S & F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane all as specified and directed by Engineer - in - Charge .
S & F figured glass 3mm thick pin head type and glazing with oil putty and securing with glazing pins not exceeding 0.50 Sqm in each pan complete all as specified and directed by Engineer - in - Charge .
M & L providing two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge .
M & L providing two coats of synthetic enamel paint and a coat of red oxide primer on new steel surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge .
S & F 15mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge .
S & F 20mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge .
Taking down steel tubing 15mm bore and connections including cleaning for refixing/ removal complete all as specified and directed by Engineer - in – Charge.
Taking down steel tubing 20mm bore and connections including cleaning for refixing/ removal complete all as specified and directed by Engineer - in – Charge.
S & F rotational moulded polythene water storage tanks, white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres all as specified and directed by Engineer - in - Charge .
S & F bib tabs long body 15 mm bore dia, fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified and directed by Engineer – in – Charge .
S&F Pillar taps 15mm bore dia, fancy type, cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed all as specified and directed by Engineer – in – Charge .
S & F 20mm bore stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified and directed by Engineer - in – Charge.
S & F 15mm bore angle valve, cast copper alloy screwed down, fancy type, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified and directed by Engineer - in – Charge.
S & F in repairs 15mm bore stop valve, fancy type, chromium plated cast copper alloy screwed down, high pressure, with long shank and cup (concealed type) with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified and directed by Engineer - in – Charge.
S & F gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 20mm bore complete all as specified and directed by Engineer – in – Charge.
M&L ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball with minimum weight 210 gm screwed for 20mm bore iron pipe supplied and fixed complete all as specified and as directed by Engineer-in-charge.
S & F grating round 125mm with waste hole of PTMT (minimum weight 40 gms) all as specified and directed by Engineer - in - Charge.
S & F swivel shower for PTMT with shower arm 195mm long with bend of 45 degree 15mm dia (minimum weight 80 gms) all as specified an directed by Engineer - in - Charge .
S & F in repairs swivel shower for PTMT with shower arm 195mm long with bend of 45 degree 15mm dia (minimum weight 80 gms) all as specified an directed by Engineer - in - Charge .
S & F towel Rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats .(Minimum weight 190gms) all as specified an directed by Engineer - in - Charge.
S & F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engineer - in – Charge.
S & F PVC connection 15mm size with PTMT nuts of length 450mm all as specified and directed by Engineer - in – Charge.
S & F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by Engineer - in - Charge .
S&F PVC ( SWR) bends any radius bore of 110 mm all as specified and directed by Engineer - in - Charge
M & L cast iron floor trap 100mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B–1 in repairs all as specified and directed by Engineer - in - Charge .
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement 110mm diameter of outlet all as specified and directed by Engineer - in - Charge
M & L reinforced concrete pipes 150mm bore class NP-3, laid and jointed complete with collars, all as specified and directed by Engineer - in - Charge.
S & F vitreous china squatting pan Orissa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime: 2 sand : 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing and provision of PVC 10 ltrs syphonic action type low level flushing cistern including PVC connection 15mm size with PTMT nuts of length 450mm and flush pipe of PVC and connection to WC pan all as specified and directed by Engineer - in - Charge .
S&F in repairs vitreous china wash down water closet (Padestal pattern) White, including plastic water closet seat cover, black, closed pattern with flat bottom with mild steel chromium plated or aluminium hinging device and fixing with all joints including connection to drain or outgoing pipe and to flushing pipe, anti-syphonage pipe etc complete all as specified and as directed by Engineer-in-Charge.
S & F in repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime: 2 sand : 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing all as specified and directed by Engineer - in - Charge .
S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve and float including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified and directed by Engineer - in - Charge .
S & F vitreous china bowl urinal flat back, size of 465 x 355 x 265mm white (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws complete with PVC flush pipe all as specified and directed by Engineer - in - Charge.
S & F Vitreous china half stall urinal white with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws complete with PVC flush pipe and half turn valve 15mm bore chromium plated all as specified and directed by Engineer - in - Charge.
S & F vitreous china wash basin, white, flat back, size 550x400mm with pillar tap cast copper alloy with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts, waste fitting brass chromium plated, PVC connection and PVC waste pipe and fixing with new brackets including cutting and pinning in ends of brackets complete all as specified and directed by Engineer - in – Charge .
S & F in repairs brass chromium plated shower rose 125mm size with or without swivel joint any size including fixing to steel pipe or union all as specified and directed by Engineer - in - Charge.
S & F PVC flexible waste pipe of standard length 25mm dia. with PVC cap suitable for waste coupling all as specified and directed by Engineer - in - Charge .
S & F soap dish brass chromium plated, fixed to plugs with brass chromium plated screws complete all as specified and directed by Engineer - in - Charge.
Dismantling of brick work built in cement mortar all as specified and directed by Engineer – in - Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified and directed by Engineer - in - Charge.
Providing and applying microfibre reinforced UV resistant Acrylic polymer coating three coats having solid contents 69% polymer content 35% & tensile strength 2.6 N/mm2 of Dr. Fixit Newcoat/ stat /Parex or equivalent with a paint brush over existing roof surface after removal of all loose material, lime dust etc. with wire brushes, coir brushes from roof surface to get absolutely cleaned surface free of foreign containment filling of cracks wherever found with polymer based mortar, and after repairing the surface apply primer coat with Dr. Fixit prime seal polyester reinforced fiber net laid on the surface repair before executing the water proofing treatment complete all as specified and directed by Engineer in Charge. Note - The treatment shall be carried out by authorised applicator approval by GE as per manufacture instructions and as directed by Engineer-in-Charge.
Certain items of external as well as internal electrification of the toilet block, ass as per directed by Engineer - in - Charge
S & F repair brass chromium plated central hole basin mixer with regular spout, popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engineer-in-Charge.
S & F Table top basin, size 500x420x190mm including waste fitting brass chromium plated, PVC waste pipe and fixing complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs for brass chromium plated shower rose 200 mm dia round shape with arm including fixing to 15 mm dia steel pipe or union all as specified and as directed by Engineer-in-Charge.
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below and as directed by Engineer-in-Charge. :- (a) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. (c) Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:4:8 over the coating as per requirement (h) Joining the sanitary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and sanitary pipe with non shrink cementatious grout complete as specified Manufacturer. Make:- Dr. Fixit/Fosroc/STP Note: (i) The treatment shall be carried out by approved authorised applicator approved by CWE as per the manufacturers instructions and as directed by the Engineer in charge. (ii) The Plan area of floor (sunken) shall be considered for payment and provn of cement work except PCC in sunken filling item 89 is included in quoted rate for this item. (iii) PCC filling in sunken portion will be measured separately.
S & F in repairs chromium plated hand jet spray/health faucet with 1 m crominium plated coated 15 mm size pipe complete all as specified and as directed by Engineer-in-Charge.
S & F false ceiling of 9.5 mm thick gypsum tiles (600mm x 600 mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or crack) fixed using T grid/Cross-T/Wall angle/level clip & suspenders/hangers 4 mm dia. GI wire (upto 1200 mm length) adjusting level fixed to roof slabs/trusses complete all as specified and as directed by Engineer-in-Charge. Make : Saint Gobain / Armstrong/Everest
Soakage well of size 3.0 m dia x 3.0 m efective depth, excavation in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring M25 concrete including one inlet chamber made of brick masonry in CM, RCC Cover slab in M25/SFRC Cover, interconnecting pipes of RCC/DWC complete filled with brick bats, external all around filled with coarse gravel, design and drawing as per Drg No CE BTD-887 dated 22 May 2018 all as specified and directed by Engineer-in-Charge.
SCHEDULE 'A' SECTION-II (E&M PORTION)
M & L point wiring complete with 1.5 Sqmm (nominal area) PVC FRLS insulated unsheathed copper stranded conductor cable with colour code in and including medium grade rigid PVC conduit with tees, bends, elbows, couplers, MS junction boxes concealed after cutting chases in wall, floor etc and making good to match with existing surface including sunken iron terminal box, 3mm thick bakelite sheet cover, clips, pipe hooks, brass screws, washers and 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light /bell point/ fan point controlled by one, one way switch all as specified and directed at site by Engineer – in – Charge.
All as per item No.137 here in before but for socket out let 3 pin 5 amp on same board all as specified and directed by Engineer - in - Charge
All as per item No.137 here in before but for socket out let 3 pin 5 amp on independent board all as specified and directed by Engineer - in - Charge
All as per Srl item No. 137 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and unsheathed cable for one multipurpose switch socket outlet 6 pin, 15 Amps on independent board including 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly.
All as per item No. 137 here in before but for socket out let 3 pin 15 amp on same board all as specified and directed by Engineer - in - Charge
All as per item No. 137 here in before but for socket out let 3 pin 15 amp on independent board all as specified and directed by Engineer - in - Charge
S & F switch piano flush type single pole one way 5 Amp all as specified and directed by Engineer - in – Charge.
S & F switch piano flush type single pole one way 15 Amp all as specified and directed by Engineer - in – Charge.
S&F socket outlet 2 in 1, 3 pin, 5 Amps, flush type all as specified and directed by Engineer-in –Charge.
S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed by Engineer-in-Charge.
S&F lamp holder, PVC / polycarbonate type with back plate for batten fittings all as specified and directed by Engineer - in - Charge.
S & F isolator single pole 40 Amp 240 volt all as specified and directed by Engineer – in – Charge .
S & F isolator triple pole and neutral 63 Amp 415 volt all as specified and directed by Engineer – in – Charge .
S & F MCB distribution board of sheet metal single pole and neutral 4 way, single door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S & F MCB distribution board of sheet metal triple pole and neutral 4 way, single door, with 200 Amp rated bus bar 440 volt all as specified and directed by Engineer-in- Charge.
S & F MCB single pole 6 to 32 Amp 240 volt with rupturing capacity not less than 10 KA all as specified and directed by Engineer – in – Charge .
S & F MCB double pole 6 to 32 Amp 240 volt with rupturing capacity not less than 10 KA all as specified and directed by Engineer – in – Charge .
S & F ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge .
S & F submain wiring with two single core cables PVC FRLS insulated unsheathed 2.5 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC insulated 1.5 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
S & F submain wiring with two single core cables PVC FRLS insulated unsheathed 6 Sqmm stranded copper conductor drawn in and including PVC casing capping with and including PVC insulated 4.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations or laying cables/ pipes etc and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers of soft / loose soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge.
Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engineer - in - Charge.
M & L sand cushioning for under ground cable 23 cm thick (one layer of 8 cm thickness before laying the cable and other layer of 15 cm thickness after laying the cable) all as specified and directed by Engineer-in-Charge.
Supplying and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable XLPE aluminium conductor armoured PVC sheathed 10 Sqmm 4 core nominal cross section in service connections all as specified and directed by Engineer – in - Charge.
Boring for road crossing in any kind of soil/rock strata all as specified and directed by Engineer-in-Charge.
M & L for LED 10W bulkhead fitting with IP-65 engineering plastic housing with clear, single phase 240C, including 1.0 sqmm copper flexible cable twisted three core along with flexible PVC conduit from ceiling rose to fitting testing complete Cat part No. BLRB 18W CW of make Bajaj or equivalent model of make Havells/ Crompton Greaves/ Philips / Wipro as approved by GE. Note : Warranty and test certificate of LED light fittings to be produced before incorporating.
Supplying and installation of electric storage water heater 25 litres vertical including temperature control system complete with all fittings and accessories, ferules Technology, incoloy glass coated heating element CFC free high density PUF insulation preventing heat loss, minimum Five star rating all as specified and as directed by Engineer-in-Charge. Make : Havells cat part No. GHWAMFSWH025 or equivalent model of BAJAJ /Crompton Greaves / V GUARD / RACOLD / ORIENT
S & F of ceiling fan of 1200mm sweep mounted in suitable arrangement for operation on 230 volts, single phase, 50 cycle per second, AC supply with electronic type regulator and connecting accessories BEE 5 Star rating and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable from ceiling rose to fan fixing in ceiling complete and making the surface good after fixing the fan complete all as specified and as directed by Engineer-in-Charge. Make : Bajaj/Havells/Crompton
S&F Air freshner PVC exhaust fan of 250-300 mm sweep with AC supply single phase 230 volts including all fixing accessories and louvers complete all as specified and as directed by Engineer-in-Charge. Make :- Crompton / Bajaj / Havells / Orient
M&L Batten for LED tube light lighting fixture with extruded aluminium heat sink, environmental friendly energy efficient ready to use with 18W LED 6000K (4') including electric connection with PVC copper flexible twin core cable, 1.0 Sqmm from ceiling rose to light fitting complete Cat part No. BLRB-DB 118 of make Bajaj or equivalent model of make Havells/ Crompton Greaves/ Philips / Wipro as approved by GE. Note : Warranty and test certificate of LED light fittings to be produced before incorporating.
M&L for LED light fitting 2"X2" recess mounting fitting with IP-43 engineering plastic housing with clear, single phase 240V, including 1.0 Sqmm copper flexible cable twisted three core along with flexible PVC conduit from ceiling rose to fitting testing complete all as specified and directed by Engineer - in - Charge. Make : Bajaj/CG/Philips
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to and including galvanized earth lead wire 4mm dia by means of GI bolts, nuts, check nuts and washers and connected other end to main board duly protected by GI pipe 15mm bore, medium grade, earth plate surrounded by packed layer of coal dust and common salt 15cm thick all around bottom and top watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate No. 3 of SSR Part – I and connecting to earthing test point, main switch board and testing on completion including CI cover, frame and PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in earthing pit with CI cover and frame including necessary earth works etc, all as specified and directed by Engineer - in – Charge. Note:- 1. PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner.
KATARIA CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .