| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC NEAR OLD POST OFFICE SUJANPUR TEH DISTT PATHANKOT PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.6 L+₹3.8 L (15.3%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹29.1 L+₹4.3 L (17.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹29.5 L+₹4.7 L (19.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹29.5 L+₹4.8 L (19.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
26 Feb 2022, 6:00 pmClosed
GE Bhopal
GE Bhopal, Bairagarh, Bhopal
REPAIR MAINT OF INTERNAL ELECTRIFICATION AND FIXTURES IN CERTAIN OFFRs JCOs AND OR MD ACCN AND REPAIR TO EM INSTALLATIONS AT SI LINES UNDER GE BHOPAL
2022_MES_506013_1
8843/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Bhopal
As per tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Bhopal
₹60,000
Yes
25 Apr 2022
5 Feb 2022
5 Mar 2022
5 Feb 2022
26 Feb 2022
19 Feb 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc, complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in and including non metallic rigid PVC casing capping not less than 25mm base size with all fitting and fixing accessories including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs, sunken sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators, etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No 2.00 above, but for one light point controlled by two way switches complete all as specified and directed .
All as per BOQ item No 2.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No 2.00 above, one 3 pin 5 Amps socket outlet point controlled by one switch on same board with other switches, complete all as specified and directed.
All as per BOQ item No 2.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination for 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly, complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit, concealed (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover, complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No 7.00 above, but for one light point controlled by two way switches complete all as specified and directed .
All as per BOQ item No.7.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No 7.00 above, one 3 pin socket outlet 5 Amps on same board all as specified and directed.
All as per BOQ item No.7.00 above, but 3 pin socket outlet 15 amps on independent board elect wiring 2.5 sq mm complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in Existing concealed conduit including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, by suitable lugs and 3 mm thick laminated hylum sheet cover including taking old point wiring (any type without conduit) complete all as specified and directed [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.12.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No 12.00 above, one 3 pin socket outlet 5 Amps on same board all as specified and directed.
All as per BOQ item No. 12.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination for 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F in repairs Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch piano, one way, single pole, 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repair socket outlet 2 in 1, 3 pin 5 and 15 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repair switch socket combination 2in 1 , type 5/6 Amps flush type, 230 volt AC complete all as specified and directed. MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE
S&F in repairs switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Buzzer electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND /HAVELLS as approved by GE]
S&F in repairs Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND /HAVELLS as approved by GE]
S&F in repair LED tube light fitting, surface mounted lumanaires, 1 x 18 W, 240V, decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps,connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. [Make : Havells Cat No : LHEXBLP7PN1W020 or equivalant in C&G/Bajaj/Surya]
Dismantling and removing tube light rod from any fitting patty/box/decorative and replacement with LED tube rod 20/22 watt, 240V, PV > 0.90, colour Temp 6500 K, system luminious efficancy > 100Lm/W completecomplete all as specified and directed. [Make : Havells C&G/Bajaj/Surya]
S&F in repairs ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular socket outlet 2-in-1, 5pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Supply and fixing modular switch socket combination 2-in-1, 5 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Supply and fixing modular switch socket combination, multipurpose 6 pin, 16 amp, 3 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Supply and fixing modular fan regulator, 5 step, high speed complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular metal flush box of 6 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
&F modular metal flush box of 4 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular metal flush box of 3 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular white cover plate of 6 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular white cover plate of 4 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular white cover plate of 3 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Taking down old unserviceable sub main wiring including service connections, of any size and any description including conduit pipe complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 2.5 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 2.5 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including wooden boards complete all as specified and directed.
S&F sheet metal enclosure for MCB, DB, TPN (Triple pole and neutral), 415 Volts, 200 amps rated busbar, 4 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
Supply and fixing factory made epoxy powder coated Distribution Board TP & N 4 ways ( VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCCB shall be measured and paid seperatly.
S&F sheet metal enclosure for SPN (single pole and neutral) DB single door type surface mounted concealed in wall 8 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid separately.
S&F MCCB 160 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 6 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE:(L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SP suitable for 240 volts, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SPN suitable for 240 volts, AC supply 32 Amps, C Curve , with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S & F in repairs MCB SPN suitable for 240 volts, AC supply 40 to 63 Amps, C curve , with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S & F in repairs MCB TPN suitable for 415 volts, AC supply 40 to 100 Amps, C curve, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in replacement 3 pin plug top AC-230 V, 5 Amp, complete all as specified and directed. Make : Anchor/LEGRAND/HAVELLS
S&F in replacement 3 pin plug top AC-230 V, 15 Amp complete all as specified and directed. Make : Anchor/LEGRAND/HAVELLS
S&F in replacement sheet metal earth plug & socket, single pole and neutral with and including 1no. single pole MCB 20 Amps 240 volts complete all as specified and directed. [Make:-Legrand Cat No. 607841 or equivalent in L&T/C&S/Havells as approved by GE].
S&F in replacement PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC, 240 V complete all as specified and directed. Make Havells/ Palza/ Polycab/Anchor
S&F non metallic rigid PVC casing and caping ISI marked of 20mm size complete all as specified and directed.
S&F non metalic PVC conduit ISI marked of size 20mm dia complete all as specified and directed.
S&F LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified and directed. [Make :- Havells Cat no VENUSNEOHE2X2R36WLED840PIRSENSOR or Equivalent in crompton/syska]
Supply and fix in repairs Coral post top lantern fitting 25 Watt (for Gate light) , energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories complete all as specified and directed. [Make: Havells , Cat NO: RUBYPT25WLED757PSYMTOPC or equivalent in Bajaj as approved by GE]
S&F building security light fitting 30 Watt made up of pressure die cast alluminium housing with high efficient LED as lighting source and pc over having top opening separate driver compartment with IP-66 Protection and impact resistance of IK07 including suitable galvanized iron pipe "light grade" brackets 1 mtr length bent to shape to obtain required shape including clamps ,nuts/bolts/washers etc connecting with suitable copper wire of size 23/0.0076 complete including all accesories ( bracket, clamps for fitting on wall) complete all as specified and directed. [Make: Bajaj Cat No: ENXTP30LWHCRPCSD or equivalent in Havells /C&G as approved by GE]
S&F in replacement flexible wire twin core copper conductor of size 23/0.0076 for ceiling fans, light fittings etc complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of size 25X 4 mm galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
S&F PVC insulated unsheathed, FRLS, copper cable 1.5 sq mm, AC, 230V, complete all as specified and directed
S&F PVC insulated unsheathed, FRLS, copper cable 2.5 sq mm, AC, 230V, complete all as specified and directed
S&F in replacement, Compact flouorcent lamp 36 watt, PL L 4P, 6500 K, 2900 Lumen,78 lm/w, from recessed/ surface mounting CFL light fitting complete all as specified and directed. [Make :- Philips Model : Philips Master, PL L 4P, 36W/865 or equivalent in Bajaj/ Crompton]
S&F in replacement, ballast 36/40 watt for compact flourecent lamp 36 watt, PL L 4P, 6500 K, 2900 Lumen, 78 lm/w, from recessed/ surface mounting CFL light fitting complete all as specified and directed. [Make :- Philips / Bajaj/ Crompton]
S&F in replacement starter 36/40 watt for Compact flouorcent lamp 36 watt, PL L 4P, 6500 K, 2900 Lumen, 78 lm/w, from recessed/ surface mounting CFL light fitting complete all as specified and directed. [Make :- Philips / Bajaj/ Crompton]
S&F in replacement first class wooden rectangular board, closed recessed type of size 250mm x 300mm x 40mm for fixing and mounting single phase KWH meter complete all as specified and as directed.
S&F in replacement first class wooden rectangular board, closed recessed type of size 300mm x 450mm x 40mm for fixing and mounting three phase KWH meter complete all as specified and as directed.
S&F LED Sleek round recess mounting LED ceiling light 1' x 1' decorative type aluminium casted edge ceiling light, recess mounting LED, luminaire 15 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified & directed. [Make :- Havells Cat No PLUTO1X1PLR15WLED840S]
S&F in repair LED tube light complete fitting, surface mounted luminanaires, 1x9 watt, 240V, decorative ultra slimround/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with bipin holders, LED Lamps, connector block, etc complete with all accessories internally prewired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed. [Make : Havells Cat No: LHEXBLP7IN1W009 or equivalent in Bajaj/ C&G]
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Demolition of brickwork/stone masonry built in cement or cement lime mortar complete all as specified and directed.
M&L for Brick work with fly ash bricks (Modular), straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M&L for Brick work with fly ash bricks (Modular size), straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
M&L for Chequered paver tiles reflective/glossy type, any colour as decided by GE, size- 300mm x 300mm x 20 to 25mm thick, set, jointed and pointed in neat cement slurry in floors, etc with & including 20mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L 25 to 35 mm thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4, complete all as specified and directed.
M&L for Machine cut Kota stone slab flooring 20-25mm thick (size not less than 450mm x 600mm) with and including 20mm thick cement screed base in CM 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar, etc with and including 10mm thick rendering in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, 75mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed.
M&L for Factory made, machine pressed, M-35 grade concrete interlocking paver blocks (glossy/reflective type), with grey cement and pigment, any shape and size conforming to IS:15658-2006 (ISI Marked) of 60 mm thickness with & including 50 mm thick stone dust cushion and joints filled with sand complete all as specified and directed. [MAKE:- MEHTAB / NAVYA TILES / SAP PAVERS/ SAGAR TILES or any ISI marked as approved by GE]
M&L for Factory made, machine pressed, M-40 grade concrete interlocking paver blocks (glossy/reflective type), with grey cement and pigment, any shape and size conforming to IS:15658-2006 (ISI Marked) of 80 mm thickness with & including 50 mm thick stone dust cushion and joints filled with sand complete all as specified and directed. [MAKE:- MEHTAB / NAVYA TILES / SAP PAVERS/ SAGAR TILES or any ISI marked as approved by GE]
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 25 mm thick Cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in leveling course, benching, sub base, complete all as specified and directed.
M&L for heavy duty flooring tiles, harsh weather & UV Resistance, high abrasion resistance, MOH Hardness >6, thickness 10 mm thick, area of each tile not less than 0.09 sqm, anti slip type, laid in floors, steps, edges, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tile with & including 15mm thick rendering in CM 1:4 complete all as specified and directed. [MAKE:-JOHNSON ENDURA or equivalent in SOMANY/ KAJARIA/ORIENT as approved by GE]
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beads complete all as specified and directed.
S&F Sheet glass 3.0 mm thick, ordinary quality not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F steel windows with side hung shutters including box type hinges with steel handle, and peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repair Aluminium alloy, anodised, sliding door bolt 300 mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F in repair 300 mm, ordinary rat tail rod pattern springs of mild steel including roller and roller plate complete all as specified and directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, ceilings, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:3 on concrete ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Dismantling Asbestos cement , corrugated or semi corrugated sheets in roofs, walls etc, fixed with new L or J type or cranked hook bolts complete all as specified and directed.
Dismantling timber in fillets, rails, posts, rafters, purlins, etc under 40 Sqcm in section, in unframed work in any position complete all as specified and directed.
M&L for Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in roof coverings/cladding to wall, etc, fixed with & including self tapping screws on angle frame complete all as specified and directed. [MAKE: TATA BLUE SCOPE / EVEREST INDUSTRIES/JINDAL as approved by GE]
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet, 0.5mm thickness, of colour as approved by GE, having tensile strength of 550 Mpa as in ridges, etc, fixed with & including self tapping screws complete all as specified and directed. [MAKE: TATA BLUE SCOPE / EVEREST INDUSTRIES/JINDAL]
S&F Framed work of rolled mild steel conforming to Fe 410-W (Gde E-250) quality -A as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting, running rails & guides) and hanging, fastening & fixing including taking down old steel/iron works complete all as specified and directed.
S&F Steel work in tubular/structural trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 or steel sections conforming to Fe 410-W (Gde E-250) quality -A complete all as specified and directed.
S&F Mild steel conforming to Fe-290 Gde E-165 in bands, straps, supports or stays for rain water, including bolts, if required, hook and pintle hinges; handmade sliding bolts; clamps; hold fasts; hooks for hanging fans and similar small articles complete all as specified and directed.
S&F Rolled mild steel conforming to Fe-290 (Gde E-165) as in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, complete all as specified and directed.
S&F in repairs Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm to 80mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (Each line wire to be measured) including dismantling old rusted/broken barbed wire, complete all as specified and directed.
Supply only chain link mild steel galvanized fencing, any type or size complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed.
Excavating in post holes (or similar holes) in hard/dense soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed.
Dismantling posts or struts (Wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground (posts embedded in concrete, brick work, masonry work, etc.) complete all as specified and directed.
Demolition of reinforced concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) of shelves, platforms, jaffri and similar work etc complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F Mild steel TMT bars 6 to 8mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Use & waste of Form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for fair finished flat surfaces of concrete complete all as specified and directed.
Use & waste of Form work to edges of concrete flats, openings, floors & roofs and sides of RCC/PCC bands in walls and similar work exceeding 5cm but not exceeding 10cm wide for fair finished surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete (Nominal Mix) type B1, 1:2:4 (using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for column, basement slabs, under reamed piles and mass concrete, complete all as specified and directed.
M&L for grouting with cement mortar with mechanical pressure through nozzles HD PVC 10 cm long 25mm dia to stop cracks/leakages seepage from wall/floor, nozzle shall be fixed at 1 mtr centre to centre in stagered manner and mortar (CM 1:1) mixed with WPC, shall be filled with pressure to stop leakage (seepage in cracks, concrete, walls or floor) till rejection, finishing the nozzles by concrete mix with epoxy treatment including taking down plaster, treatment to be made as per manufacturer’s instructions complete all as specified and directed.
Deduct schedule of credit (calculation will be done off line) Rs. 59430.00
Samaksh Enterprises
deepak mehra & associates
M/s AKG Engineers & Contractors
H S ENTERPRISES
RAJPATI CONSTRUCTION
M/S RAKESH TRADERS
M/s VIKAS TRADERS
Vee kay construction
M/S Shanti Traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .