Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹12.9 L+₹3.3 L (34.6%)Rejected-AOC 37 4TH CROSS ASHWATHNAGAR SANJYANAGAR POST BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
18 Sept 2024, 6:00 pmClosed
COL MANOJ NEGI
CWE AF NORTH BANGALORE BELLARY ROAD JC NAGAR POST BANGALORE 560006
REPAIR MAINTEANANCE OF DG SETS AMF PANELS CABLES INCLUDING PAINTINGS AND OTHER CONNECTED WORKS AT HQTC BANGALORE
2024_MES_666610_1
87443CWEAFNBAN
Open Tender
Civil Works
Item Rate
330 days
GE (AF) BANGALORE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (AF) BANGALORE
₹30,000
Yes
16 Oct 2024
19 Jul 2024
25 Sept 2024
20 Jul 2024
18 Sept 2024
5 Aug 2024
20 Jul 2024 - 29 Jul 2024
Amount
Maintenance and servicing of Diesel Generator sets by carrying out routine 'A' check of the engine complete for smooth functioning of 250 KVA DG Set Make: Cummins-Model-6CTAA at power house all as per manufacturer's instructions and as directed :- NOTES:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work. (ii) Servicing of DG set alongwith connected Alternator and Panel Board including 'A' check of the Engine shall be carried out monthly basis (Contractor shall detail his mechanic to check all the DG sets on all working days to check the serviceability and report any abnormality found in DG sets to the JE/ AGE E/M) as directed by the Engineer-in-Charge and the Contractor shall carry out periodical inspections during the maintenanace period and shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenance / breakdown repairs as and when required in that period except in case of major repairs. (iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be included in the rate quoted. (iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (v) List of checks to be carriedout under 'A' check is attached as Appendix 'A' to the Particular specifications.
All as per item No 1 above but for 140 KVA DG set Make:-Cummins -type- 6CTA at MAP II
All as per item No 1 above but for 125 KVA DG set Make:-Ashok layland at power house
All as per item No 1 above but for 125 KVA DG set. Make: Mahindra behind REB
All as per item No 1 above but for 100 KVA DG set. Make: Ashok layland at power house
All as per item No 1 above but for 100 KVA DG set. Make:-Ashok layland at DMSS
All as per item No 1 above but for 100 KVA DG set. Make: Kirloskar -type-6R1040 TA at CCC. Note : 100 KVA DG set -02 Nos at CCC
All as per item No 1 above but for 82.5KVA DG set. at pump house & STP
All as per item No 1 above but for 40 KVA DG set. Make:-Cummins at MAP I
Maintenance and servicing of Diesel Generator sets by carrying out routine 'B' check of the engine including items covered in 'A' check complete for smooth functioning of 250 KVA DG Set Make: Cummins-Model-6CTAA at power house all as per manufacturer's instructions and as directed. NOTES:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exclusive for servicing/ maintenance of the above item of work. (ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set alongwith connected Alternator and Panel Board including items covered in 'A' check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG Set for a period of 30 days from the date of service and shall also attend all the maintenance / breakdown repairs as and when required in that period except in case of Major repairs. (iii) Spare parts , engine oil and radiaton coolant oil required for replacement during the maintenance period shall be measured and paid seperatly at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. (iv) Cost of all consumables, diesel / oil filters etc., required during the maintenance period shall be deemed to be included in the rate quoted for this item. (v) List of checks to be carriedout under 'B' check is attached as Appendix 'A' to the Particular specifications.
All as per item No 10 above but for 140 KVA DG set Make:-Cummins -type- 6CTA
All as per item No 10 above but for 125 KVA DG set Make:-Cummins -type- 6BTA
All as per item No 10 above but for 125 KVA DG set. Make: Mahindra behind REB
All as per item No 10 above but for 100 KVA DG set. Make: Kirloskar -type-RB66 TA.
All as per item No 10 above but for 100 KVA DG set. Make:-Cummins -type-NTC 495 G
All as per item No 10 above but for 100 KVA DG set. Make: Kirloskar -type-6R1040 TA at CCC. (100 KVA DG set -02 Nos)
All as per item No 10 above but for 82.5KVA DG set. Make:-Cummins -type-6BT
All as per item No 10 above but for 40 KVA DG set. Make:-Cummins
Overhauling of following mentioned Self Starter assembly of DG Set by disconnecting and removing from the engine , cleaning all accessories, replace the wornout parts like :- brushes, bushes, contact plates, jumping leads and seals, revarnishing the field coil, armature and reassembling the same , refitting to the engine , including testing on load after repairs all as directed . For Self starter assembly, 24 Volt DC [Make - Delco Remi]/ Self starter assembly, 24 Volt DC [Make - lucas TVS ]
All as per item No 19 above but for Self starter assembly, 12 Volt DC [Make - lucas TVS ]
Checking for radiator, disconnecting the radiator hoses and taking down the radiator assembly complete from the engine , dismantling the top & bottom chambers , descalling the sediments and scales , corrosion etc., by means of acid cleaning and high pressure water washing , air blast cleaning ,re- assembling the same with new gaskets, including arresting leakage , if any and fixing to the engine with new hoses ,clips for 250 KVA DG Set complete all as required and directed. Note : The rate quoted shall be inclusive of servicing parts of the radiator and all incidental charges.
All as per item No 21 above but for 140 KVA DG set.
All as per item No 21 above but for 125 KVA DG set.
All as per item No 21 above but for 100 KVA DG set.
All as per item No 21 above but for 100 KVA DG set.
All as per item No 21 above but for 82.5KVA DG set.
All as per item No 21 above but for 40 KVA DG set.
Checking the engine for abormal running of engine due to improper flow of fuel, overhauling the fuel injection pump assy and Injectors by disconnecting the fuel supply lines, and taking out FIP to workshop for servicing /repair , replacing the worn out / un- servicable parts like service kit, D - Valve, Elements , nozzles etc., as required and calibrating the same for increasing proper flow with pressure & efficiency , assembling at site and testing on load all as directed for 250 KVA DG Set/140 KVA DG set capacity of Gen sets.
All as per item No 28 above but for 125 KVA DG set/ 100 KVA DG set.
All as per item No 28 above but for 82.5KVA DG set/40 KVA DG set.
Supply only Lead acid battery 12 volt 180 AH Make :- Exide/ Express/Amco
Supply only Lead acid battery 12 volt 150 AH Make :- Exide/ Express/Amco
Supply only Lead acid battery 12 volt 110 AH Make :- Exide/ Express/Amco
Supply only Engine Oil SAE 15W-40W. Make :- (VOLVOLINE/IOC )
Supply only radiator coolant. Make :- (VOLVOLINE/IOC )
Supply only fan belt as per existing make for 250 KVA DG Set/ 140 KVA DG set capacities of DG set.
Supply only fan belt as per existing for 125 KVA DG set/ 100 KVA DG set.
Supply only fan belt as per existing for 82.5KVA DG set/ 40 KVA DG set.
Supply only Air filter element as per existing make for 250/ 140 KVA DG Set capacities of DG sets.
Supply only Air Filter element as per existing make for 125/100 KVA DG set.
Supply only Air Filter element as per existing make for 82.5/ 40KVA DG set.
Supply only Solenoid switch, 24 Volts, DC Suitable for DG SET
Supply only Solenoid switch, 12 Volts, DC Suitable for DG SET
Supply only electronic Hooter 12 volts DC.
Supply only Water Temp gauge with adopter.
Supply only Oil Temp gauge with adopter.
Supply only Oil pressure meter with pipe.
Supply only Timer AC / DC.
Supply only PLA Relay with Base AC/DC.
Supply only Single phase preventer.
Supply only MCB 16amps.
Supply only Push Button for start , stop, reset.
Supply only Digital type Frequency meter.
Supply only Digital type Volt mete.
Supply only Digital type Ammeter.
Supply only Indicator lamps [LED Type].
Supply only Two pole ON/OFF switch assembly.
Supply only LLOP switch assembly.
Supply only HWT switch assembly.
Supply only Ignation switch assembly.
Supply only surge suppressor for MCX 41-45.
Supply and fix Automatic Voltage Regulator Suitable for140KVA/ 250 KVA DG set incl taking out old unserviceable AVR complete all as speciifed and directed.
Supply and fix Automatic Voltage Regulator Suitable for 125/100 KVA DG set incl taking out old unserviceable AVR complete all as speciifed and directed.
Supply and fix Automatic Voltage Regulator Suitable for 82.5/40 KVA DG set incl taking out old unserviceable AVR complete all as speciifed and directed.
M/L for fixing the static SCR type 15 Amps battery charger 12 volt DC in existing control panel including necessary connections , cutting for fixing the volt meter , ammeter and connecting the battery complete all as speciifed and directed. Make : Naren
M&L for spray painting of DG sets complete upto 140 KVA capacity with one coat of synthetic enamel paint of existing colour and writing MES/ SM No complete all as speciifed and directed.
Supply and fix contactor 4 pole, 160 amps 415 Volts Model no MCX 132/135 including taking down unserviceable contactor complete all as speciifed and directed. Make L & T or equivalent .
Supply and fix MCCB 4 pole 63 A rating, 25 KA with 80-100 thermal settings in LT panel including taking down unserviceable MCCB complete all as speciifed and directed.
Supply and fix MCCB 4 pole 250 Amps , 36 kA, with 200-250 thermal settings 415 volts including taking down unserviceable MCCB complete all as speciifed and directed.
Supply and fix MCCB 4 pole 400Amps , 50 kA, with thermal settings 415 volts including taking down unserviceable MCCB complete all as speciifed and directed.
M/S J S PRAKASAM (BID ID -3098994)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .