Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC Reasonable lowest tenderer | |
| 2 | L2₹10.9 L+₹37,714.40 (3.59%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Tenderer | |
| 3 | L3₹11.3 L+₹85,241.90 (8.12%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Tenderer | |
| 4 | L4₹11.4 L+₹95,639 (9.11%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Tenderer | |
| 5 | L5₹11.6 L+₹1.1 L (10.5%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L5 | Rejected-Finance Not Lowest Tenderer |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
20 Apr 2022, 6:00 pmClosed
GE (East ) Ferozepur Cantt.
GE (East ) Ferozepur Cantt.
REPAIR/ MAINT OF WATER SUPPLY PIPE LINES/ PIPE SETS AND ALLIED WORKS AT 2 ASD KASUBEGU AND ALG AREA UNDERF GE (EAST) FEROZEPUR CANTT.
2022_MES_503228_3
8146/GE/E/FZR/21-22/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE (East ) Ferozepur Cantt.
please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (East ) Ferozepur Cantt
₹20,000
Yes
19 May 2022
5 Apr 2022
22 Apr 2022
5 Apr 2022
20 Apr 2022
15 Apr 2022
Amount
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for getting out in any type of soil complete all as specified and as directed by Engr/in/Charge.
Returning filling in including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil all as spd.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified .
Taking out cast iron water main/Ductile iron ( including all fittings) Bore of pipe 150mm. with spigot and socket ends including burning out lead joints and recovering lead , cleaning the pipe and removing to store for reuse of serviceable portion complete all as directed of following sizes :- ( Note :- Excavation & Earth Work shall be measured and paid seperately under relevant items. )
All as per Item No 4 here in before But of Bore of pipe 100 mm.
All as per Item No 4 here in before But of Bore of pipe 80 mm.
Supply and laying Ductile iron pipes of Bore of pipe 150mm with spigot and socket ends centrifugally cement mortar lined complete as per IS8329/2000 class K -9 with including suitable for tyton joint and jointing material / joints laid in trenches laid in trenches complete all as specified and directed:- Note:-DI specials and earth work shall be measured and paid separately. Make :- Electro steel, Lanco, Kesoram, Tata metaliks,Electro therm.
All as per Item No 7 here in before But of Bore of pipe 100 mm.
M&L Cast iron pipes with spigot and socket ends centrifugally cast Class LA, in any length laid in trenches complete all as specified of 80mm dia bore. Note:-CI specials and earth work shall be measured and paid separately. Make :- Electro steel, Lanco, Kesoram, Tata metaliks,Electro therm.
M&L for relaying/re-routing serviceable portion of CI/DI pipe line of Bore of pipe 150mm obtained from item no 4 after through cleaning/Srubbing internally and externally all as directed by Engr-in-Charge Note : Excavation , CI specials & lead joint will be measured and paid seperately under relevant item of sch.
All as per Item No 10 here in before But of Bore of pipe 100 mm.
All as per Item No 10 here in before But of Bore of pipe 80 mm.
Burnning out run lead joints and spoun yarn in any position for Bore of pipe 150mm including excavation, returning filling and removal complele all as specified and directed.
All as per Item No 13 here in before But of Bore of pipe 100 mm.
All as per Item No 13 here in before But of Bore of pipe 80 mm.
M & L for DI /CI Specials like Bends ( any type radius and angle) tapers any type, Tees branch single piece all sockets spigots collars,caps plugs ,tail piece etc of size 200/150/100/80 mm dia completed as speicified and directed.
Taking out Old U/S rusted/Broken Galvanised iron water main GI pipe of dia 80mm ( including all fittings) cleaning the pipe and removing to store for reuse of serviceable portion if any complete all as directed : Note :- Excavation & Earth Work shall be measured and paid seperately under relevant items.
All as per Item No 17 here in before But of Bore of pipe 50 mm.
All as per Item No 17 here in before But of Bore of pipe 40 mm.
All as per Item No 17 here in before But of Bore of pipe 25 mm.
All as per Item No 17 here in before But of Bore of pipe 15 mm.
Supply and laying / fixing Galvanised iron pipe, medium grade GI pipe of dia 80mm with and including all fittings and testing, complete all as specified and directed:- Note:Excavation & Earth Work shall be measured and paid seperately under relevant items of this schedule. Make :- Jindal, TATA, Prakash Tubes
All as per Item No 22 here in before But of Bore of pipe 50 mm.
All as per Item No 22 here in before But of Bore of pipe 40 mm.
All as per Item No 22 here in before But of Bore of pipe 25 mm.
All as per Item No 22 here in before But of Bore of pipe 15 mm.
Refixing old steel tubing and re-routing/relaying of serviceable portion of GI pipe line of GI pipe of dia 80 mm after through cleaning/Srubbing internally and externally all as directed by Engr-in-Charge Note : (i) Serviceable GI tubing obtained from item No 17 will be reused (ii) Excavation will be measured and paid seperately under relevant item of sch. (iii) Minor items such as Sockets,union,Tee, bends,elbow reqd are demeed to be included in unit rate.
All as per Item No 27 here in before But of Bore of pipe 50 mm. Note : (i) Serviceable GI tubing obtained from item No 18 will be reused (ii) Excavation will be measured and paid seperately under relevant item of sch. (iii) Minor items such as Sockets,union,Tee, bends,elbow reqd are demeed to be included in unit rate.
All as per Item No 27 here in before But of Bore of pipe 40 mm.Note : (i) Serviceable GI tubing obtained from item No 19 will be reused (ii) Excavation will be measured and paid seperately under relevant item of sch. (iii) Minor items such as Sockets,union,Tee, bends,elbow reqd are demeed to be included in unit rate.
All as per Item No 27 here in before But of Bore of pipe 25 mm. Note : (i) Serviceable GI tubing obtained from item No 20 will be reused (ii) Excavation will be measured and paid seperately under relevant item of sch. (iii) Minor items such as Sockets,union,Tee, bends,elbow reqd are demeed to be included in unit rate.
All as per Item No 27 here in before But of Bore of pipe 15 mm. Note : (i) Serviceable GI tubing obtained from item No 21 will be reused (ii) Excavation will be measured and paid seperately under relevant item of sch. (iii) Minor items such as Sockets,union,Tee, bends,elbow reqd are demeed to be included in unit rate.
Taking out Sluice Valve Refacing,regrinding and refixing of 150 mm bore complete all as specified and directed.
All as per Item No 32 here in before But of Bore of pipe 100 mm.
All as per Item No 32 here in before But of Bore of pipe 80 mm.
Taking out old U/S sluice valve/Non return valve any type any size
Supply and fixing Sluice valve for 200 mm dia pipe ISI marked flanged type, class PN 1.6 with Stainless steel spindle, necesary bolts & nuts of suitable size with and including rubber gasket for flanged joints and testing complete of following sizes all as specified and directed:- Make : Leader / BIR / ZOLOTO
All as per Item No 36 here in before But of Bore of pipe 150 mm.
All as per Item No 36 here in before But of Bore of pipe 100 mm.
All as per Item No 36 here in before But of Bore of pipe 80 mm.
Supply and fixing CI Non return valves for 150mm dia pipe ISI marked, flanged type class PN 1.6 with necesary bolts & nuts of following size with and including rubber gasket for flanged joints and testing complete of following sizes all as specified and directed. Make : BIR/Leader/ ZOLOTO
Taking out old U/S stop valve/ Gate valve any type any size complete all as specified and directed
Supply and fixing UPVC globe/gate valve for 50mm Dia pipe ISI marked with and including jointing materials complete all as specified and directed Make :- Advance,Bir, Leader, Sant.
Supply and fixing Gun metal globe/gate valve for 25mm dia pipe ISI marked with and including jointing materials complete all as specified and directed of following sizes:- Make :- Advance,Bir, Leader, Sant.
All as per Item No 43 here in before But for Bore of pipe 20 mm.
All as per Item No 43 here in before But for Bore of pipe 15 mm.
Cutting existing cast iron pipe in position for insertion of CI specials & fittings viz Tee, Collar, Bend, or Tail piece etc for 80 mm bore pipe including removing of blockage, cleaning of pipe line complete all as specified and directed. Note:- (i) Joints and CI fittings will be measured and paid separately under respective items of this schedule.
Cutting existing cast iron pipe in position for insertion of CI specials & fittings viz Tee, Collar, Bend, or Tail piece etc for 100 mm bore pipe including removing of blockage, cleaning of pipe line complete all as specified and directed. Note:- Joints and CI fittings will be measured and paid separately under respective items of this schedule.
Cutting existing cast iron pipe in position for insertion of CI specials & fittings viz Tee, Collar, Bend, or Tail piece etc for 150 mm bore pipe including removing of blockage, cleaning of pipe line complete all as specified and directed. Note:- Joints and CI fittings will be measured and paid separately under respective items of schedule.
M & L for cocking of lead joints for cast iron pipe of 150 mm bore including spun yarn and lead to stop the leakage of water from the joint including excavation, returning filling and removal complete all as specified and directed.
All as per Item No 49 here in before But for Bore of pipe 100 mm.
All as per Item No 49 here in before But for Bore of pipe 80 mm.
Cutting/Welding to GI pipe line 50/40 mm bore joints to sockets or flanges on both side complete all as directed at site by Engr in charge.
Repair / Replacement of MS sheet cover not less than 3mm thick with handle and locking arrangement and painting with two coats of synthetic enamelled paint over a coat of red oxide primer on steel surface including welding suitable for valve pit 105x105x120 cm,90x90x90, 60x60x90 cm or any size as reqd all as directed at site by Engr in charge.
Dismantling/reparing/welding the existing CI/MS pipe line 200/150/100/80mm bore joint by welding or replacing rubber packing or worn out nuts,bolts and washers inluding replacement of sluice valve of 150 mm/100mm/80mm dia size as reqd of any make provided vertical in rising /supply/overflow washout of overhead reservoir by means of all required T&P like lifting jack for holding the vertical pipe , scaffolding etc Note : (i) All type of T&P required for work is deemed to be included in the quoted rate) (ii) Sluice valve 150mm/100mm/80mm dia will be measured and paid seperately under relevant item of Sch.
Cleaning the U/G Sump cap 50000 gallons (twin or single chamber) by draining the complete water and brushing the surfaces with iron brush and removing the complete mud/silt and getting washed the complete inner surfaces of the tank and writing date of cleaning the tank all as specified and directed by the Engr- in-charge. Note : ( All type of T&P required for cleaning deemed to be included in the quoted rate)
M&L cleaning of valve pit chamber of size 1.2m x 1.2 m x 0.6 m with sluice valve, pipes etc including replacement of existing wornout/defective gland packing, nut, bolt & washer, etc with new one to make the sluice valve perfectly leak proof of complete all as required and directed
All as per item No 56 above but of size 0.9m x 0.9m x 0.6m complete all as specified and directed.
Painting of rising main,Delivery, wash out, overflow line of OH reservoir 100/150/200 mm dia bore pipe by scraping, dust cleaning body by wire brush and applying two coats of synthetic enamel paint of standard colour as approved by Engr-in-Charge and forming the arrow showing direction of water flow all as specified and directed. Note : All T&P required for painting the pipe lines is deemed to be included in unit rate.
Supply and fix Cast iron Air Valves with two air outlet 100 mm dia fixing up in water supply rising main Ductile Iron /CI Pipe, all as specified and directed by Engr-in-charge..
S&F Submersible cable PVC of copper conductor of size16 sqmm 3 core of required length from panel to star delta starter and motor of VT/Submersible pumping set installed complete all as specified and directed.
S&F Star Deluxe Automatic star delta submersible pump starter 3 Phase ,415 Volt ,50 HZ with SPP conforms to IS :13947-4 for 30 HP to 40 HP pump of contact size 50 and overload relay range 55-70 Amps , Coil voltage 380V , with single phase preventer Make L&T or Equivalent of Havells ,Simens complete all as specified and directed.
Demolition of cement concrete in ground floor and paving not exceeding 15 cm thickness (below or above ground) as specified and directed.
M&L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in paving/footpath and finished the surface even and smooth without using extra cement and making impression of expanded metal, whilst the concrete is green complete all as specified and directed
S&F GI tubing of medium grade 65mm dia (3 mtr long) to each hand pump machine in replacement of length and lowering the pipe in bore hole after joining with 32mm dia pipe providing GI reducer 65x32mm complete all as specified
S&F GI tubing medium grade 32mm dia approx 10 mtr long piece in replacement of length and lowering the pipe in bore hole all as specified and directed
Supply and lowering starter slotted type made out of 32mm dia GI pipe medium grade of length 1.5 mtr long along with MS plug welded at the one end of the strater complete all as specified and directed.
Supply and fixing on the strainer of the filter PVC net cloth of size 1.5mtrx0.75 mtr to prevent the passage complete all as specified and directed.
Supply only Altoch -GP complete all as specified and directed
Dismantling existing hand pump and its accessories such as hand pump machine, handle, suction box and taking out GI pipes and stainer etc from under ground hand pump bore well and Servicing,cleaning the hand pump,assembling testing complete all as specified and directed.
Supply and fixing in position after replacing the Gun metal sleeves of 65/30mm threaded on both sides complete all as specified and directed.
Supply and fixing in position after replacing the Non return valve as suitable along with rubber washer complete all as specified and directed.
Supply and fixing in position after replacing the Steel connecting rod 12 mm dia 5 mtr long incl connecting socket and "U'' clamp nuts bolts and washers etc along with rubber washer complete all as specified and directed.
Supply and fixing in position after replacing the GI sunction valve complete with PVC washer(Heavy Duty) complete all as specified and directed.
Supply and fixing in position after replacing the Head assmbly complete with clamp hold fast handle nuts bolts and washers GI pipe etc complete all as specified and directed.
Attending emergency breakdown of water supply installations where directed, Lifting defective submersible pumpset, column pipes (any number) from bore well, setting aside and stacking column pipes for reuse, lowering of submersible pumpset with column pipes in the bore well as existingand making water and electrical connections as existing for running of pump motors complete all as directed. Note: (i) lifting /lowerig shall be measured and paid only once for same nature of repair. (ii) In case the Submersible Pump Set falls down during Extn/Lowering the same shall be Extracted by contracter at his own arrangements and nothing extra from the department shall be admissible on this account what-so-ever
Supply only New Rubber gasket for submerible pump column pipes as per existing dia complete all as specified and directed
Supply only New Nut and Bolt & washer for submerible pump column pipes as per existing dia and length complete all as specified and directed
Repairs to submersible pumpset of capacity 30-35 HP 3 phase, 415 volts involving the following operations : (a) Opening of the defective motor in MES yard/ workshop, cleaning the covers and parts as applicable in presence of Engineer in Charge to ascertain the quantam of defects and repairs involved. (b) Transporting the defective motor to contractors workshop for repairs as directed by the Engineer in Charge and carrying out the needful repairs including replacement of defective unserviceable parts. (c) Assembling the motor after repair. (d) Transporting the repaired motor to MES yard/ workshop and carrying out necessary test in presence of Engineer in Charge to establish the functionability of the repaired motor up to the entire satisfaction of the Engineer in Charge.
All as per item No.78 here in before but for submersible pumpset and motor of capacity 5-7.5 HP all as directed. Note for item No. 78 to 79 above: (i) Any parts required to be replaced during servicing, overhauling of motor, pump set etc shall be measured and paid for separately under appropriate item as "Supply only" of this schedule. However labour element involved in replacement is deemed to be included in quoted rates against this item. (ii) Any minor repairs involved to make the motor, pump functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department. (iii) Rewinding of stator of motor, any machine to pump where involved shall be measured and paid separately against relevant item of this schedule. (iv) Greasing/ oiling etc of parts as required shall be done by the contractor without any extra cost to the department.
Supply only Water lubricant seal suitable for motor of submersible pumpset of cap 7.5 HP to 35 HP .
Supply only Bowl assembly for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only T bolt for motor for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only Thrust bearing for motors as per existing for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only Stud Ring set for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only Neck ring for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only Stainless steel key for impeller shaft for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only Impeller CI/Bronze type for for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only Stainless steel motor - pump coupler for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only bush for pump as per existing for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only Bushes to motor shaft as per existing for submersible pumpset of cap 7.5 HP to 35 HP .
Supply only Repair to Impeller by brazing or as required for for submersible pumpset of cap 7.5 HP to 35 HP .
Rewinding of stator of submersible motor pump working on 3 phase 415 to 440 V volts of capacity 30 HP-35HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed.
Rewinding of stator of submersible motor pump working on 3 phase 415 to 440 V volts of capacity 7.5 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed.
Manjeet Singh Contractor
shivam builders
M/S Pee Kay Builders
S S BUILDERS
manoj and company
Kissan contractor and engg works
M/S Yashpaul Gulati
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .