Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | ₹17.9 L Quoted ₹17.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹17.9 L+₹5,583 (0.31%)Rejected-Finance 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | ₹17.9 L+₹5,583 (0.31%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹19.9 L+₹2.1 L (12.0%)Rejected-Finance CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | ₹19.9 L+₹2.1 L (12.0%) | L3 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
21 Oct 2020, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer 345001
REPAIR AND MAINT OF LT UG CABLE/OH LINE NETWORK AND MISC WORK FOR ZONE II UNDER THE JURISDICTION OF GE ARMY JAISALMER
2020_MES_375449_1
8954/20-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹40,000
Yes
25 Feb 2021
7 Sept 2020
23 Oct 2020
7 Sept 2020
21 Oct 2020
17 Sept 2020
Amount
Taking down the old existing unsv LT Cable of any size etc all as specified and directed.
Taking out serviceable / unserviceable stone patti from excavated trenches.
Relaying the stone patti in the excavated trench .
Taking down old U/S MCCBs of any type and make.
Taking down old U/S rusted and U/S GI Pipe of any type and make.
Taking down old U/S, broken HT cable route indicator of any type and make.
Taking down old U/S, broken LT cable route indicator of any type and make.
Taking down old U/S, on load change over of any type and make.
Excavation in trenches in soft/disintegrated rocks not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or soil for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engineer-in-Charge.
Excavation in trenches in soft/disintegrated rocks not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable and erection of poles a all as specified and directed at site.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/disintegrated soil in any type of soil all as specified & directed by Engineer-in-Charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness will be measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-charge.
Supply,Laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 10 Sqmm 4 core complete all as specified and directed by Engineer-in-charge. (Make: Havells, Polycab,CCI)
--- ditto --- all as per item No. 15.00 above but of 16 Sqmm 4 Core.
--- ditto --- all as per item No. 15.00 above but of 25 Sqmm 4 Core.
--- ditto --- all as per item No. 15.00 above but of 35 Sqmm 3.5 Core.
--- ditto --- all as per item No. 15.00 above but of 70 Sqmm 3.5 Core.
--- ditto --- all as per item No. 15.00 above but of 95 Sqmm 3.5 Core.
Laying only and jointing, testing (after through inspection of cable and rectification of fault) XLPE/PVC insulated, armoured, heavy duty, aluminum conductor cable 1100 Volts grade of any description, laid in trenches/ ducts, floors, fixed to wall etc.complete all as specified and directed for the following size: Note :- (Cable will be issued under Sch 'B') :-
(a) 50 Sqmm 3.5 Core.
(b) 120 Sqmm 3.5 Core.
(c) 150 Sqmm 3.5 Core.
(d) 185 Sqmm 3.5 Core.
Dismantling insulator any type,any size all as specified and directed.
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of stay assembly including necessary form work all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified & directed by Engineer-in-Charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair LT 1100 Volt pin type porcelain/ vitreous china, white, brown, or green insulator height 100 mmx 65mm dia, grade incl. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete all as specified and directed by Engineer-in-Charge. (Make : Jaipuria Brothers/ABB/Pactil).
S&F in repair shackle insulator, Porcelain, vitreous, white, brown or green insulator height 100 mmx 115 mm max dia grade including galvanised mild steel straps, washers, insulators bolts, washers and nuts, complete all as specified and directed by Engineer-in-charge. (Make : Jaipuria Brothers/ABB/Pactil).
Dismantling of ACSR conductor of any size from LT/HT pole complete all as specified and directed.
Dismantling of earth wire of any size from LT/HT pole complete all as specified and directed.
Refixing the retreaved ACSR.
Supply and fixing aluminium conductor steel reinforced [ACSR] straining properly on insulators on PCC pole 9 mtr long and binding with aluminium tape/binding wire, connectors, jumpers etc including taking down old ACSR conductor complete all as specified and directed by Engineer-in-Charge of required size.
Supply and fixing galvanised earth wire of size 4.00 mm dia, straining properly on cross arms on PCC LT/HT pole and binding with aluminium tape/binding wire, connectors including taking down old GI earth wire complete all as specified of required size.
Supply fabricate , fixing in repair structural mild steel RS joist , channel angle iron, flat iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clamps, eye hook and back plate etc fabricated from structural steel section including nuts , bolts, washers, welding (cold and hot ) drilling holes for bolts, bend to any shape or size as indicated and directed , inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
Opening the binding wire from pin / shackle insulator on steel/PCC pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin / shackale insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- Charge. NOTE: (i) The above work includes clearing/ prooning of tree branches falling around the conductors. (ii) Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid.
Opening the binding wire from "J" hook or opening nut, bolts of cross arms on steel/PCC pole of any height for re-stretching the galvanised iron earth wire any size, after re-stretching without kinks & bend , binding the "J" hook with appropriate size of aluminium binding wire or fixing with appropriate size of nut, bolts, washers complete all specified & directed by Engineer-in- Charge. NOTE: (i) Cost of binding wire / nut bolts and washers deemed to be included in the quoted rate, No extra amount will be paid.
M & L for stay assembly comprising of 16 mm dia,1.80 meter long galvanized stay rod,having 7/3.15 mm GI stay wire stranded and 230 mm x 230 mm x 6 mm thick stay plate,complete all as shown on electric plate No.1 of SSR part-I 2009 with and including all necessary fittings/accessories like loop insulators,stay clamps complete all as specified and directed.
Scrubbing the old paint and prepare the smooth surface of PCC pole with the help of wire brush and emery paper. Painting of PCC pole upto 1.5 mtr above ground level and making alternative strip in black and white colour of 30 cm each (Total - 05 Nos) with synthetic enamel paint including marking and writing complete all as specified and as directed by Engineer-in-Charge.
Scrubbing the old paint and prepare the smooth surface of steel tubular pole with the help of wire brush and emery paper. Painting of steel tubular pole from ground level to top with two coat of synthetic enamel paint over a coat of red oxide and making alternative strip in black and white colour of 30 cm each (Total - 05 Nos) with synthetic enamel paint including marking and writing complete all as specified and as directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing on completion with earth chamber and test point terminal complete all as specified and directed by Engineer-in-Charge.
M & L for ON load change over switch of capacity 300 Amps,4 pole, 415 Volts,50 Hz complete all accessories and specified and directed.As per sample.Make :
M & L for ON load change over switch of capacity 400 Amps,4 pole, 415 Volts,50 Hz complete all accessories and specified and directed.As per sample.Make :
S&F in repair MCCB, 63 Amps, four pole,16 KA, 415 volt with fixed thermal maganetic release all as specified and Engineer-in- Charge. Note: ICS = ICU 100%. (Make:- Legrand/ABB/Siemens).
S&F in repair MCCB, 100 Amps, four pole,16 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%. (Make:- Legrand/ABB/Siemens).
S&F in repair MCCB, 160 Amps, four pole, 16 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%. (Make:-Legrand/ABB/Siemens).
S&F in repair MCCB, 200 Amps, four pole, 25 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%. (Make:- Legrand/ABB/Siemens).
S&F in repair MCCB, 250 Amps, four pole, 35 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%. (Make:- Legrand/ABB/Siemens).
S&F in repair MCCB, 400 Amps, four pole, 35 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%. (Make:- Legrand/ABB/Siemens).
S&F in repair MCCB, 630 Amps, four pole, 35 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge. Note: ICS = ICU 100%. (Make:-Legrand/ABB/Siemens).
S&F GI pipe light grade of dia 50 mm laying in road and along with poles for cable protection complete including taking down old pipe all as directed byEngineer-in-Charge. (Make :- Jindal/Tata/Prakash Surya).
------ ditto ----- all as per item No. 49 above but size 80mm dia. (Make :- Jindal/Tata/Prakash Surya).
------ ditto ----- all as per item No. 49 above but size 100mm dia. (Make :- Jindal/Tata/Prakash Surya).
Supply, transportation fixing and erection of prestressed cement concrete pole 9 metre long, minimum cross section 102 mm x 172 mm at top and 102 mm x279 mm at bottom class -10 confirming to IS-1678 and including making alternate white and black strips 30 cm height (Total 5 Nos ), with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in-Charge.
Supply, transportation fixing and erection of prestressed cement concrete pole 11 metre long, minimum cross section 152 mm x 152 mm at top and 152 mm x260 mm at bottom class -9 confirming to IS-1678 and including making alternate white and black strips 30 cm height (Total 5 Nos ), with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in-Charge.
Dismantling broken concrete poles/struts of any size complete all as specified & directed by Engineer-in- Charge.
Cutting and trimming the tree branches touching the over head lines of LT/HT one meter around the conductor and removal the same from the site complete all as specified and directed.
S & F HT cable route indicator made out of cast iron plate of 150 mm dia 4 thick having embosed wiriting HT cable fixed on MS angle iron 30x30x5 mm of 900 mm long with two nuts,bolts and grouting 500 mm length under ground and splitted and bent to shape and embedded in ground with PCC (15 cmx 15cm x 15 cm complete all as specified and directed.
S & F LT cable route indicator made out of cast iron plate of 150 mm dia 4 thick having embosed wiriting LT cable fixed on MS angle iron 30x30x5 mm of 900 mm long with two nuts,bolts and grouting 500 mm length under ground and splitted and bent to shape and embedded in ground with PCC (15 cmx 15cm x 15 cm complete all as specified and directed.
S&F in repair, LT Cable 6 Sqmm Twin Core, aluminium multstrand, PVC insulated and sheathed, 1100 Volts grade complete all as specified and directed by Engineer-in-Charge. (Make: Havells, Polycab,CCI)
S&F in repair, LT Cable 10 Sqmm Twin Core, aluminium multstrand, PVC insulated and sheathed, 1100 Volts grade complete all as specified and directed by Engineer-in-Charge. (Make: Havells, Polycab,CCI)
Supply,jointing and testing outdoor type heat shrinkable end teriminal cable joint including all material and accessories suitable for 3.5 core 16 to 35 Sqmm of 1100 Volts grade all as per manufacture recommendation complete all as specified and directed.Make :- Dension/M seal/Raychem.
All as per item No 60 above here-in-before but suitable size for 3.5 Core 50 to 95 Sqmm.
All as per item No. 60 above here-in-before but suitable size for 3.5 Core 120 to 185 Sqmm.
All as per item No 60 above here-in-before but suitable size for 3.5 Core 240 to 320 Sqmm.
Labour only for checking and disconnecting the cable from both ends,testing the serviceblity of cable by meggering and reconnecting the same after detection of fault complete all as specified and directed of following size :-
(a) 10 Sqmm to 16 Sqmm 3.5 core
(b) 25 Sqmm to 50 Sqmm 3.5 core
(c) 70 Sqmm to 150 Sqmm 3.5 core
Dismantling & Taking down old climbing device and fixing for anti climbing device, comprising 2.24 mm dia galvanised steel-2 strand barbed wire with 2.00 mm dia barbs wrapped spirally round poles to a length of 0.5 to 1.0 mtr clamped and properly secured or as orded (clamps measured seperatly all as specified).
Dismantling, taking down and removing the old existing unsv non-functional/broken hinges of any description and in any postiion of existing feeder piller boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100mm long medium weight mild steel but hineges in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangments complete all as specified and directed by Engineer-in-Charge.(Note : All Hinges fixed in one panel will be considred under one job only )
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shape, supply, fixing and febrication in existing, shape and size with and including 2 mm thick CRCA sheet and all jointing material such as nuts, bolts or washer and welding etc.
NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/wermin proof for installing incoming/ outgoing MCCB/ Switch fuses/cable etc complete all as directed. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board. (iii) The replaced porting shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer. (iv) The rates quoted by the contrqactor deemed to be with and including dismantling/taking out/removing carefully, any damaged part/portion of the feeder pillar box/panel board as directed.
Preparation of the old decorated existing external and internal steel surfaces of feeder pillar boxes/panels/boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrpping or by blow stopping as required and applying two coats of synthetic enameled paint (grey in colour) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-Charge.
S R ENTERPRISES
M/S PRASHANT BENIWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .