| 1 | L1₹34.8 LAccepted-AOC SHOP NO 04 AKBAR ARCADE NEAR INDRAYANI BRIDGE LONAVLA PUNE 410401 | PUNE | MAHARASHTRA | 410401 | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹38.7 L+₹3.3 L (9.27%)Rejected-Finance 601 A WING SAI PARAMOUNT APARTMENT SHRADDHA VIHAR COLONY INDIRANAGAR NASHIK NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹39.9 L+₹4.6 L (12.9%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L4₹40.9 L+₹5.6 L (15.7%)Rejected-Finance FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L4 | Rejected-Finance GREATER THAN L1 | |
| 5 | L5₹41.1 L+₹5.7 L (16.0%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L5 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹35.5 L
EMD Value
₹71,000
Closing Date
26 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Gaurav Tiwari, IDSE, EE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
SPL REPAIRS TO ROOF OF MEIKB, STATIC BAY, LIVE BAY AND CLASS ROOMS (BLDG. NO P-293), PROVN OF GRILLS FOR WINDOWS ON THE FIRST FLOOR OF DAYASHANKAR BLOCK (P-218), DEFICIENT PARKING SHED AT DEEKSHA BUILDING (BLDG. NO P-546) AND DEFICIENT GEYSER IN F-B
2024_MES_645711_1
GE/LONAVLA/8229/E8
Open Tender
Civil Works
Item Rate
225 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹71,000
Yes
20 May 2024
8 Mar 2024
28 Mar 2024
8 Mar 2024
26 Mar 2024
15 Mar 2024
8 Mar 2024 - 14 Mar 2024
Amount
Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosaic wherever occurs over roof and chhajja surfaces and scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris to a distance exc. 1500m but n.exc. 2000m etc complete all as specified and directed by Engr-in-charge.
M/L for rendering 10mm thick in cm 1:4 on concrete roof and chajja surface to get a uniform level surface for laying of membrane treatment all as directed
M/L for PCC 1:2:4 type B-1 (using 20mm graded agg) for PCC padding on RCC roof surface finished even and smoother using extra cement all as specified and directed by Engr-in-Charge.
M&L for water proofing treatment to RCC roof slab all as specified below and as directed:- a) Apply one coat of bitumous primer @ 0.25 Kg/Sqm. (b) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (c) Laying APP polymer modified membrane 4mm thick with non woven polyster reinforcement weighing not less than 4.00 Kg/ Sqm applied by torch application method. (d) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/sqm of the surface area. (e) Laying APP polymer modified membrane 4mm thick with non woven polyster reinforcement weighing not less than 4.00 Kg/ Sqm applied by torch application method. (f) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/sqm of the surface area. (g) Apply a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm.
Disconnecting existing tanks of any capacity setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after carrying out Roof treatment with all accessories all as specified and directed
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Material and Labour for Rendering cement plaster on stone/brick masonary surfaces in two coats, 8mm thick in CM 1:4 and mixing with waterproofing compound @ 3% of total weight of cement over 12mm thick in CM 1:6 on external faces of walls finished even and fair complete all as specified and directed. NOTE: Water proofing compound shall be measured and paid separately.
Material and labour for 5 mm thick rendering on concrete ceiling surfaces in CM 1:3, finished even and smooth without using extra cement all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
M&L preparation of old/ new plastered surfaces including complete removal of existing treatment on old plastered wall including removing fungus/ algae dirt, oil, grease and loose particles by wire brush, cleaning, washing and removing dust and cracks more than 5mm shall be sealed with "Pidilite URP" manufactured by DR Fixit or with "Plaster seal" manufactured by STP and cracks more than 2mm and less than 5mm shall be sealed with " crack X powder" manufactured by Dr.Fixit or "Plaster seal" manufactured by STP and applying primer and two coats of water proof decorative elastomeric coating of approved shade/colour complete all as specified and as directed. Note :- (i) Primer shall be "Prime seal" manufactured by DR Fixit or "Plaster seal" manufactured by STP. (ii) Water proofing decorative elastomeric coat shall be Rain coat DFT 100 manufactured by Dr Fixit or Shalicry 215 manufactured by STP. (iii) The rate of application of primer and waterproofing coat shall be as per manufacturers instructions. (iv) A time gap of eight hours shall be maintained between the application primer and each water proof coat after application of sealant. (v) Unit rate quoted shall be deemed to include for necessary scaffolding for execution of the same.
M&L for preparation of new plastered surface of ceiling surface and applying three coats of white wash etc all as specified and directed.
Material and labour for preparation of existing wall surfaces including crack & patch filling making surface plain and uniform with wall care putty and applying two coats of oil bound distemper on walls complete all as specified and as directed.
S&F Anodised aluminium grill DG-104 (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of windows handles and fixing approved anodised aluminium standard C section around the opening, all complete as per requirement and direction of Engineer?in-charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil
Excavating in post holes (or similar holes) each n exc 1.00 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard/dense soil
M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc confirming to Fe-410W (Gde E-250) quality -A grade (work at a hight of upto 7mtr including scaffolding etc) complete all as specified and directed
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F MSA Flat wind ties for roof including securing bolts, posts and struts including all necessary drilling bolt or riveting etc and similar work confirming to FE-290 Gde E-165.
M&L preparation of new steel surfaces of any descriplain, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide chrome primer all as specified and as directed.
M & L PCC (1:3:6) type C-2 (Using 40 mm graded stone agg.) as in foundation, bed blocks, filling and mass concrete.
M/L Brick work with sub class ‘B’ bricks on straight or curved on plan to any radius in full brick work in CM 1:6.
M & L 15mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. (a) One light point or one fan point or bell point controlled by one switch
(b) One 3 pin socket outlet, 5 Amp independent
(c) One 3 pin socket outlet, 5 Amp on the same board with other switches
All as per item No.23 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed.
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed by engineer in charge.
Supply and fixing Batten 1x18W(single side supply)for LED TUBE LIGHT pre -coated CRCAA sheett, end caps made up with engineering plastic all as specified and directed.Make : Bajaj (BLRB - DB 118) or equivlent PhilipsHavells.
Supply and fixing ROD 1x18W (single side supply)for LED TUBE LIGHT T8 tube with polycarbonate body all as specified and directed.Make : Bajaj (BLRB - 20W LED) or equivlent PhilipsHavells.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Highbay luminaire with AL die-cast housing for efficient thermal heat management and secondary modular lens optimised light distribution to improve operational efficiency with EMC/EMI compliant potted driver,flicker free illumination .Make -Bajaj Cat No. TENTO NXT B 88L WH MB SD 80W WHITE, Duranto Highbay Light or equivalent Philips/Havells/Crompton .Note:(a) Highbay led life warranty 3 yrs provide by contractor of company (b)S' Steel chain for hanging LED with each LED provide by contractor.
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x2.5 sq. mm +1x1.5 sq. mm earth wire earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 2.5 sqmm wire and One run of 1.5 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x4.0 sq. mm +1x2.5 sq. mm earth wire earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 4 sqmm wire and One run of 2.5 sqmm wire and One run of PVC casing caping will be measured as one running meter.
S&F in repairs MCB SP 5 To 32 AMP, single pole 240 Volts 10KA ''C''&''B'' curve , as per site requirment,Complete all as specified and directed.
S&F in repairs MCB SPN 6-32 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc. complete all as specified and directed.
S & F of PVC connections 15mm size with PTMT nuts of length 300mm complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings with outer diameter of 20mm in trenches complete all as specified.
S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof
M & L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.’25 mtr below normal ground level) with top edge of the plate not less 1.5 mtr below normal ground level connected to galvanized earth plate with 4.0 mm thick GI wire by means of suitable size of GI nuts, bolts, check nuts and washers all as specified in electrical plate SSR Part I including necessary .Exc & earth work, providing charcoal and salt dust layers and construction of PCC pit in 1:3:6 using 20 mm size graded stone aggregate, precast RCC 40 mm thick cover in 1:2:4 type B 1 with 12 mm dia steel MS plain bar, lifting handle GI pipe of 50 mm bore for earth lead protection andGI pipe 15 mm dia for watering, with funnel and wire mesh including testing on completion. All as specified and as directed incl dismentling existing unsserviciable earthing .
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size120 sq mm 3.5 core
Supply,& fixing Onload change over switch with enclosure of capacity 1000 Amps 415 Volt , 50 Hz four pole type Make : - Havells or equivalent with INDOASIAN, L&T & STANDARD
SAI SAMARTH ENTERPRISES
M/s S.D Construction Co
DWARKESH STRUCT-CON
SHAILENDRA B TULSANI
RK AND SONS CREATION
VIJAYA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .