Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹30.5 L+₹1.8 L (6.33%)Rejected-Finance 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L2 | Rejected-Finance Rejected being not L1 | |
| 3 | L3₹35.1 L+₹6.4 L (22.4%)Rejected-Finance | L3 | Rejected-Finance Rejected being not L1 | |
| 4 | L4₹35.4 L+₹6.7 L (23.4%)Rejected-Finance | L4 | Rejected-Finance Rejected being not L1 | |
| 5 | L5₹35.6 L+₹6.9 L (23.9%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹50.0 L
EMD Value
₹99,980
Closing Date
5 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (MES) ROORKEE
Garrison Engineer Roorkee
PROVN OF HIGH MAST LIGHT AND CERTAIN MINOR AND REVENUE WORK AT RTS AND DEPOT SAHARANPUR UNDER GE ROORKEE
2024_MES_636026_1
8392/344/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
SAHARANPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (MES) ROORKEE
₹99,980
Yes
11 Mar 2024
5 Jan 2024
7 Feb 2024
5 Jan 2024
5 Feb 2024
22 Jan 2024
Amount
Supply & installation of 20 Metre height high mast shaft in two section suitbale for 44 m/sec wind speed bearing capacity along with head frame, luminiaries carriage suitable for 08 luminiaries in symmetrical arrangement and other accesories manufactured in approved factory with raising lowering system comprising double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightining finial, (Wiring material from Junction Box to individual luminiare & MCB in base compartment are part of installation), including provision of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template and outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminiaries, power tool control with 2 No 9A contactors and raise lower push button, Incoming cable 25 sq. mm and out going cable 16 & 2.5sq. mm terminals including one number aviation obstruction light (along with reqd wiring) & lightening arrester spike (along with 6 sq mm copper cable connect to earthing) with following accessoroes and components complete all as specified and directed. Make for light fittings and high mast: bajaj or equivalent in GE, Crompton, Philips, Havells, BPP high Mast( B.P. Project PVT LTD)
HIGH MAST SYSTEM MAKE : Approved Make Height of mast : 20 Metre No. of Section : Two Plate Thickness : Top - 3 MM, Bottom- 4 MM Material Construction : HT Steel as per BS-EN10 025 Base dia and top diameter (A/F) : Top : 150mm Bottom : 410 mm Cross section of Mast : 20 side polygon Standard for Galvanisation : A per BS EN ISO 1461 Size of Opening and door at base : 1200 x 250 mm Diameter of base plate : 570 mm Thickness of base plate : 25 mm Lighting protection finial : GI single spike of length 1200mm Max. wind speed : 44m/s as per IS 875 (Part III) Number of foundation bolts : 12 Nos PCD of foundation bolts : 490 mm Type / diameter / length of foundation bolts : TS 600/30mm dia/ 850 mm long
FOUNDATION DETAILS 1. Excavation dimensions 2800 x 2800 x 1500mm size 2. Lean Concrete 100 mm thick PCC ( 1:4:8) D2 (using 40mm graded Aggregate) 3. Matt bars 12mm dia TMT Bars @ 200C/C both ways in double layers 4. RCC (1: 1.5 : 3) 2600 X 2600 X300MM as in footing 5. RCC (1 : 1.5 : 3) 1000 X 1000 X 1400 MM (1100MM below GL and 300 mm above GL) 6. 8 Nos 16mm dia TMT Bars 4 at corners 4 at centres of pedastal col as main bar with 600mm long craking at bottom over matt bars 7. 16 Nos 12mm dia TMT main bars (4 Nos each at 4 side with 600mm long cranking at bottom over matt bars. 8. 10mm dia TMT bars @ 100mm C/C as Stirrups 9. 300mm dia 850mm long foundation bolts 08 Nos inserted in to 16 mm thick anchoring plate 590mm dia at bottom with pointed galvanised nut one each at bottom and top of plate. 10. Foundaiton bolt min clearance 150mm above pedestal col to rest high mast base plate 25mm thick over the bolts. Galvanised nuts 01 number at bottom of base plate 2 Nos at top of base plate. Note : The unit rate is inclusive of necessary formwork, RFR removal of surplus earth, foundation concrete,external finishes and all other unforeseen items all as directed by Engr - in- Charge
LUMINAIRES CARRIAGE Material of construction : 50 NB ERW Class B-M.S Pipe Diameter of carriage ring (mm) : 710 mm (ID) Construction : 09 Arm, Welded Load carrying capacity : 09 Luminaire
TRAILING CABLE Conductor : Copper, 5 core, 2.5 Sqmm Insulation : EPR insulated PCP scheathed No.of circuits per mast : One
WINCH / POWER TOOL Type /SWL of winch : single gear Double drum, SWL 500 Kg Method of Operation : Integral Motor Motor Capacity : 2 HP ( Including suitable starter) No of Speeds : 6 Pole, Single speed Torque Limitor : With Mechanical Tripping Facility
STAINLESS STEEL WIRE ROPE Grade / construction : AISI 316, 7/19 Construction Number of Ropes : Two Continuous Diameter (mm) : SS304 Grade, 6 mm Breaking load Capacity : 2350 Kg (minimum)
Supply & installation of 15 Metre height high mast shaft in two section suitbale for 44 m/sec wind speed bearing capacity along with head frame, luminiaries carriage suitable for 08 luminiaries in symmetrical arrangement and other accesories manufactured in factory with raising lowering system comprising double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightining finial, (Wiring material from JB to individual luminiare & MCB in base compartment are not included and are a part of installation), with supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template and outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminiaries, power tool control with 2 No 9A contactors and raise lower push button, Incoming cable 35 sq. mm and out going cable 16 & 2.5sq. mm terminals including one number aviation obstruction light (along with reqd wiring) & lightening arrester spike (along with 6 sq mm copper cable connect to earthing) with following accessoroes and components complete all as specified and directed. Make for light fittings and high mast: bajaj or equivalent in GE, Crompton, Philips, Havells, BPP high Mast( B.P. Project PVT LTD)
HIGH MAST SYSTEM MAKE : Approved Make Height of mast : 15/16 Meter No. of Section : Two Plate Thickness : Top - 3 MM, Bottom- 4 MM Material Construction : S355 Grade as per BS-EN10 025 Base dia and top diameter (A/F): Top : 150mm Bottom : 460 mm Cross section of Mast : 20 side polygon Standard for Galvanisation : A per BS EN ISO 1461 Size of Opening and door at base : 1200 x 250 mm Diameter of base plate : 670 mm Thickness of base plate : 25 mm Lighting protection finial : GI single spike of length 1200mm Max. wind speed : 44m/s as per IS 875 (Part III) Number of foundation bolts : 12 Nos PCD of foundation bolts : 590 mm Type / diameter / length of foundation bolts : TS 600/30mm dia/ 850 mm long
FOUNDATION DETAILS 1. Excavation dimensions 2800 x 2800 x 1500mm size 2. Lean Concrete 100 mm thick PCC ( 1:4:8) D2 (using 40mm graded Aggregate) 3. Matt bars 12mm dia TMT Bars @ 200C/C both ways in double layers 4. RCC (1: 1.5 : 3) 2600 X 2600 X300MM as in footing 5. RCC (1 : 1.5 : 3) 1000 X 1000 X 1400 MM (1100MM below GL and 300 mm above GL) 6. 8 Nos 16mm dia TMT Bars 4 at corners 4 at centres of pedastal col as main bar with 600mm long craking at bottom over matt bars 7. 16 Nos 12mm dia TMT main bars (4 Nos each at 4 side with 600mm long cranking at bottom over matt bars. 8. 10mm dia TMT bars @ 100mm C/C as Stirrups 9. 300mm dia 850mm long foundation bolts 08 Nos inserted in to 16 mm thick anchoring plate 590mm dia at bottom with pointed galvanised nut one each at bottom and top of plate. 10. Foundaiton bolt min clearance 150mm above pedestal col to rest high mast base plate 25mm thick over the bolts. Galvanised nuts 01 number at bottom of base plate 2 Nos at top of base plate. Note : The unit rate is inclusive of necessary formwork, RFR removal of surplus earth, foundation concrete,external finishes and all other unforeseen items all as directed by Engr - in- Charge
LUMINAIRES CARRIAGE Material of construction : 50 NB ERW Class B-M.S Pipe Diameter of carriage ring (mm) : 535 mm (ID) Construction : 06 Arm, Welded, 2 Sections Load carrying capacity : 08 Luminaire
TRAILING CABLE Conductor : Copper, 5 core, 2.5 Sqmm Insulation : EPR insulated PCP scheathed No.of circuits per mast : One
WINCH / POWER TOOL Type /SWL of winch : Single gear, Double drum, SWL 500 Kg Method of Operation : Integral Motor Motor Capacity : 1.5 HP ( Including suitable starter) No of Speeds : 6 Pole, Single speed Torque Limitor : With Mechanical Tripping Facility
STAINLESS STEEL WIRE ROPE Grade / construction : AISI 316, 7/19 Construction Number of Ropes : Two Continuous Diameter (mm) : SS304 grade, 6 mm Breaking load Capacity : 2350 Kg x 2
S&F LED Flood light fitting 1 x 200 Watts ((Make : Bajaj Cat No GLEAM F 220L WH SY PC SD V2 200W LED)
Supply installation commisioning and testing high mast timer Panel outdoor type total enclosed weather proof dust vermin proof MS Sheet iron clad of 3.15 mm thick powder coated with inter connecting with copper wire and MS angle frame of 40mm X 40mm X 5 mm complete comprising of the following :-
INCOMINGS
(a) MCB 4 POLE 415 V 63 A -01 No.
OUTGOINGS
(a) MCB 6-32 Amp - 1 No
(b) 40 Amp TP Contactor -03 No
(f) Indicator RYB - 1 Set
(g) Push Button and auto manual switch (Raise and low switch)
(g) Timer - 1 No
Material & labour XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 Sqmm, 3.5 core complete all as specified and directed.
Excavation in trecnhces, n.exc 1.5 m wide and n.exc 1.5 m in depth, for foundation / laying of UG cable, etc or for shafts, well, cesspits, manholes, pier holes, etc n.exc 10 sq m on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returing, filling, spreading, leveling, watering & well ramming in layers n.exc 25 cm thick as in soil complete all as specified and directed.
Removing excavated soil n.exc 50 mtr and depositing as directed n.exc 1.5 mtr above the starting point complete all as specified and directed.
M&L dry clean Sand filling in trenches around underground cables for cushioning, complete all as specified and directed. Note: Depth of sand shall be measured after punning complete all as specified and directed.
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
S&F 50mm dia GI pipe light grade for protecting cable over road crossing complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick burried directly in ground. (earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 25x4 mm GI strip as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to High mast & panel, including testing on completion complete all as specified and directed .
Supply,installed and commissioning of air cooled split unit air conditioner (All weather AC with hot & cold) electric driven single phase of capacity of 1.5 TR, complete all as specified and directed. Make:- LG Cat No- RS-H19VNXE /Hitachi cat no FTHT 50 or equvilant in Voltas/Blue Star/Usha
Supply,installed and commissioning of Deep freezer electric driven, single phase, 240 volt, glass top up of 300 to 320 litre capacity having single door complete all as specified and directed . Make:- Godrej/Blue Star/Voltas
Supply,installed and commissioning of storage water cooler full stainless steel body, electric driven, single phase, 240 volt of storage capacity 80 ltrs and nominal cooling capacity 40 ltrs per hrs with water connection complete all as specified and directed. Make:- Voltas/Blue Star/Usha
Supply and installed voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4 KVA complete all as specified and directed.
Supply and installed voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 1 KVA complete all as specified and directed.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
M & L for sub main wiring with two runs of single core PVC insulated unsheathed 1100V grade multistranded copper conductor cable 4 Sqmm size incl suitable size PVC casing and caping fixed in wall surface type incl one run 2.5 Sqmm PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed.
M & L for sub main wiring with two runs of single core PVC insulated unsheathed 1100V grade multistranded copper conductor cable 2.5 Sqmm size incl suitable size PVC casing and caping fixed in wall surface type incl one run 1.5 Sqmm PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts grade PVC insulated unsheathed cable drawn in and including surface PVC casing & caping of suitable size with all accessories ,with PVC 1.5 Sqmm multi standard insulated unsheathed copper wire for continuous earth, sunk in cast iron/MS terminal box duly painted with aluminum inside and anticorrosive paint out side with 2.8 mm thick laminated white bakelite sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed. (a) One light point /Exhaust fan point controlled by one switch with 1.5 sqmm multi stranded copper conductor 1100 volts grade PVC insulated unsheathed cable complete all as specified and directed.
S&F in replacement switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
Supply and fix PVC inlet/outlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser (nuts of length 300mm ) complete all as specified and directed.
Supply and fix angle stop valve, brass chronium plated, 15mm bore screwed down high pressure with crutch or butter fly handle screwed both ends fixed to GI pipe complete all as specified and directed.
Supply and fix bib tap chromium plated of size 15 mm, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Cutting existing steel tubing for alterations or additions (Each cut measured separately), complete all as specified and directed for 15 mm bore GI pipes complete all as specified and directed.
Supply , fixing & laying only GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittings for laid in trenches/wall/ceiling/ floor/ all as specified and directed of 15 mm bore dia complete all as specified and directed.
Supply and fix in replacement vertical water heater,storage type steel body with steel inner tank and heating element upto 1.5/ 2 KW capacity 25 litre, BEE 5 Star rated, ISI Marked, 240 V, 50 Hz complete with all accessories such as safety valve, thermostate, Plug top, NRV, Hot and cold water connection pipe all as specified and directed.
S&F exhaust fan, steel body, 300mm, 900 RPM with louvers, single phase, 240V AC including necessary fittings and M&L for fixing arrangement on wall with frame holdfastener, bolt, washer, etc including connection with PVC insulated PVC sheathed copper cable of size 0.5 sqmm from ceiling rose to connector, fixing of exhaust fan on plywood of size minimum 12mm thickness cut to shape, suitable for 300 mm metal body exhaust fan including making hole on wall as per exhaust fan size and making good as per existing surrounded wall complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm M&L for fixing arrangement on wall with frame hold fastener, bolt, washer, etc including connection with PVC insulated PVC sheathed copper cable of size 0.5 sqmm from ceiling rose to connector including making hole on wall as per exhaust fan size and making good as per existing surrounded wall complete all as specified and directed.
KAPOOR ELECTRICALS
RAMSONS DEVELOPERS
KUKREJA BROTHERS
OMVIN ENTERPRISES LLP
SIYA ASSOCIATES
NITHYA INFRATECH
Pradeep Bros
janta tradrers
PARADISE INFRA POWER COMPANY
TARUN ENGINEERING WORKS
RAMAPATI ENGINEERING SERVICES
M/s Kang Builders & Developers
M/s RAM RATAN AND SONS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .