Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 LAccepted-AOC 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹43.1 L+₹14,836 (0.35%)Rejected-AOC GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 3 | L3₹48.0 L+₹5.1 L (11.8%)Rejected-AOC | L3 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 4 | L4₹49.9 L+₹6.9 L (16.0%)Rejected-AOC | L4 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 5 | L5₹52.1 L+₹9.1 L (21.2%)Rejected-AOC | L5 | Rejected-AOC REJECTED DUE TO NOT LOWEST |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
6 Oct 2022, 6:00 pmClosed
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
SPECIAL REPAIR TO CERTAIN AC PLANTS UNDER GE (AF) LOHEGAON AT AIR FORCE STATION PUNE
2022_MES_544488_2
8601/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹91,000
Yes
5 Dec 2022
17 Sept 2022
13 Oct 2022
17 Sept 2022
6 Oct 2022
24 Sept 2022
Amount
Supply installation & testing of HW air cooled split type 5 Star rated Inverter Air Conditioner 2.0 TR capacity having dual rotor inverter compressor , 7 filters, iFeel, Blow clean, Hidden display, Comfort sleep, 5 Sensors, 100% copper IDU & ODU, installation kit including extra length of copper piping, connection eclect cord, drain water pipe and core cutting in stone masonary wall if required for passing of refrigerant piping & cables etc and making good to the disturbed surface matching to existing specification complete all as specified and directed.
Supply installation & testing of HW air cooled split type 5 Star rated Inverter Air Conditioner 1.0 TR capacity having dual rotor inverter compressor , 7 filters, iFeel, Blow clean, Hidden display, Comfort sleep, 5 Sensors, 100% copper IDU & ODU, installation kit including extra length of copper piping, connection eclect cord, drain water pipe and core cutting in stone masonary wall if required for passing of refrigerant piping & cables etc and making good to the disturbed surface matching to existing specification complete all as specified and directed.
M&L for taking out the existing unserviceable split/window type AC any capacity & deposit to E/M store yard for further disposal , including making good to the disturbed surface matching to esisting specifications complete all as specified and directed.
M&L for Sheet metel enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volt complete all as specified and directed.
M&L for sub main wiring with two runs of single core 4.0 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 2.5 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping complete all as specified and directed.
M&L for taking out carefully damaged ducting including all accessories complete all as specified and directed.
Supply assembly and erection of GI sheet with C &SS rectangular/square duct made out of L shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints ect complete of size 22 gauge all as specified and including with required scaffolding work to install the ducts at site complete all as specified and directed. Note :-(i) for measurement only the final finished area in Sqmm shall be measured. (ii) Vanes, splitters, MS frames for joints, flanges, access doors etc shall not be measured separately. These shall be treated as part of duct work. (iii) only external angle Iron/C channel duct support shall be measured and paid separatly.
Ditto all as per Ser Item No 7.00 above but 20 gauge galvanized sheet steel complete all as specified and directed.
M&L for duct thermal insulation class O nitrile rubber based thermal insulation 19 mm thick with treated woven glass fibre covering of 0.18mm thick, density of 200+20 GSM, Tensile strength 275+-25 Kg/mm for exposed to sun application (green colour) including fixing with adhesive which is specifically formulated for duct insulation which shall be free from benzene and joints shall be fixed with glass cloth foil based tape with self adhesive ability to ensure 100% leak proof, including taking out existing unsv insulation material, cleaning the duct surface complete all as specified and directed.
Supply, installation, testing and commissioning of site fabricated MS channel / angle structure work complete all as specified and directed.
M/s Vijay Airconditioning Pvt Ltd
BRITE INDUSTRIES
AIRFRAME
somnath engineering corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .