Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.4 L+₹2.6 L (20.8%)Rejected-Finance 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹15.5 L+₹2.7 L (21.6%)Rejected-Finance E 37 CWE AF SOUTH BANGALORE A I A II B I | BENGALURU URBAN | KARNATAKA | 560001 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹15.5 L+₹2.8 L (21.9%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹21.3 L+₹8.6 L (67.3%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Mar 2023, 6:00 pmClosed
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIR /REPLACEMENT OF NORMAL ELECTRIC LIGHT FITTING INTO ENERGY EFFCIENT LED FITTING AND (REPLACEMENT OF OLD CONDUICT WIRING OF AIRMEN L IN ACCOMMODATION (CPL BELOW) AT AT AFAC COIMBATORE.
2023_MES_580321_1
84227/E8
Open Tender
Civil Works
Item Rate
120 days
AGE (I) (AF) Coimbatore
AS per tender document
7 documents required · 7 mandatory
₹500
AGE (I) (AF) Coimbatore
₹40,000
19 Apr 2023
10 Feb 2023
17 Mar 2023
10 Feb 2023
15 Mar 2023
3 Mar 2023
11 Feb 2023 - 20 Feb 2023
Amount
Taking down carefully the point wiring (light, Fan, socket or power) complete, (fittings such as switches, sockets any type, ceiling roses, pandents, light fittings, etc.to be measured seperately) removing materials for keeping in safe custody or for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
Taking down ceiling fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed.
Taking down exhaust fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed.
Hanging/Refixing only ceiling fan and connecting up including provision of cable from celling rose/ connector to fan all as specified and as directed.
Refixing only exhaust fan and connecting up including provision of cable from celling rose/ connector to fan all as specified and as directed.
M& L for painting of ceiling fan/ exhaust fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc all as specified and as directed.
M&L for concealed point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps etc complete including pressed steel sunken boxes 2 mm thick concealed in walls including 3 mm thick phenolic laminated sheet cover and including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor connected with dolly, all as specified and as directed for the following :- Note: ( Cutting chases and making good in wall / floor will be Measured and paid seperately.
One light point controlled by one, one way switch.
One ceiling / exhaust fan point controlled by one, one way switch.
One , 2 way light point controlled by 2, two way switches.
One 05 Amps socket outlet point on same board.
One 05 Amps socket outlet point on independent board.
All as per item No. 7 described here-in-before but with copper conductor cable FRLS, 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
Note for item No. 7 &8 : Cutting chases and making good in wall / floor will be Measured and paid seperately.
Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals.
S&F Switch piano, flush type single pole, one way 05 Amps complete all as specified and as directed.
S&F Switch piano, flush type single pole, one way 15 Amps complete all as specified and as directed.
S&F Switch piano, flush type 2 way 5 Amps complete all as specified and as directed.
S&F Socket outlet 3/5 pin, 06 Amps, flush type complete all as specified and as directed.
S&F multi socket outlet , 2 in 1, 3 pin, 16 Amps, flush type complete all as specified and as directed.
S&F step type,electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
Taking down old lights and Supply & fixing LED mirror light helios 10 watt complete. Make: Havekks/ Crompton/Bajaj.
Taking down old lights and Supply & fixing LED PRIDE PLUS DECOR 1x20 watt surface mounting tube light fitting with tube rod complete and making connection complete. Make: Havells Cat No. LHEXACP71N1J020 or equivelent in crompton/ Bajaj.
Taking down old lights and Supply & fixing Lumiline Plus LED batten 1x10 watt surface mounting tube light fitting with tube rod complete and making connection complete. Make: Havells Cat No LHEXACP7FN1W010 or equivelent/Bajaj/ Crompton.
Taking down old lights and Supply & fixing LED lamp 15 Watt complete. Make-Havells/Bajaj/Crompton.
Taking down old lights and Supply and fixing building security light 30 Watt, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 complete including fixing bracket of suitable size . Make:Havells Cat No.LHEXAYP7PN6K030, or Equivelent in Bajaj/ Crompton.
Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces all as directed.
M&L for concealed Sub main wiring by making recess in wall/surface complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc for three phase sockets all as specified and as directed by engr - in- charge. Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
Supply and fix sheet metal enclosure with distribution board vertical (DB) VTPN, 415 volts, having IP:43 protection, isolated neutral bar, insulated busbar assembly, door earthing arrangement, mechanical impact strength IK08, 04 way double door suitable for fixing MCCB 125 Amps as incommer and MCBs SP as out going complet, fixed on wall and connecting with all electric connections/circuit complete all as directed by Engineer in charge. Make: L&T/Havells/C &S.
Supply and fix MCCB 3 pole, 16 KA, 415 V, F1 frame, adjustable thermal setting, 125 Amps complete. Make: L&T/ Havells/Legrand.
Supply and fix MCB DB, SPN, 8 ways, Isolated neutral bar, IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete.
Supply and fix MCB SPN 32 Amps, 240Volts, 10 KA, "B" Curve complete. Make: L&T/ Havells/Legrand.
Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, "B" Curve complete. Make: L&T/ Havells/ Legrand.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and 20mm bore medium grade GI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:2:4 type B-1 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009. (i) The unit rate includes earthing wire, and protection pipe upto 7.5 metre.
M&L for 4 mm dia galvanised iron or steel wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete.
Disconnecting carefully electric energy meter single phase and keeping aside , and re-fixing the same after necessary wiring work complete.
Disconnecting carefully old unserviceable distribution boards any sizes including MCBs complete and making good the disturbed surface of wall.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth
rvelectricals
SEMBA ELECTRICALS
p.chinnasamy
D NAGI REDDY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .