Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC As per bid committee minutes | |
| 2 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC As per bid committee minutes | |
| 3 | L2₹18.9 L+₹5.4 L (7.25%)Accepted-AOC | L2 | Accepted-AOC As per bid committee minutes | |
| 4 | Rejected-Technical | - | Rejected-Technical Bidder does not have single work order of value more than the package value |
Tender Value
₹82.4 L
EMD Value
₹1.6 L
Closing Date
19 Oct 2022, 2:00 pmClosed
The SE,Nagaon Circle(I),Nagaon
The Superintending Engineer ,Nagaon Circle(I),Nagaon
Repairing of barge, Repairing and Renovation works of Brick lined Main Canal Bed and Side walls from Ch.0.00 to Ch.103.00, Repairing of Main Canal Bed and Side walls from Ch. 85.00m -335.00m of Main Canal,Supply and Installation of pumpset, supply
2022_ID_27221_1
SEI/T-27/ET-7/2022-23/487 Dtd 28/09/2022
Open Tender
Civil Works
Item Rate
90 days
Phulaguri
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,700
Yes
₹1.6 L
Yes
19 Dec 2022
29 Sept 2022
19 Oct 2022
29 Sept 2022
19 Oct 2022
29 Sept 2022
Amount
Repairing & Renovation works of Brick linned Main Canal Bed and Side walls from Ch.0.00 to Ch.103.00.
Labour charge for dismantling of old CC works of canal structures and carriage the spoils and depositing the same in a safe distance as directed. : Carriage up to lead of 30 M and lift upto 1.50 M
River sand filling in plinth, canal bed, canal slopes, bases of structure, etc in layers not more than 150 mm thick including necessary carriage, watering etc, complete as directed as specified.
CC work in proportion 1:2:4 in foundation / abutment / piers / wing walls etc.with hard broken stone aggregate of size 6 mm to 20 mm including curing with necessary timber shuttering, scaffolding where necessary complete as directed.(Shuttering, scaffolding cost will be paid separately) WITH HARD BROKEN STONE AGGREGATE 6 MM TO 20 MM
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc,including racking out joints and curing etc, complete as directed.(i) In proportion 1:4
12 mm cement plastering including clearing surface and curing, complete as directed. (ii) In proportion 1:4
Earthwork in back filling of structures, obtained from outside borrow pits filling in 15 cm layers, ramming, dressing, watering, including paying compensation of land if any (with lead up to 30 M and lift 1.5 M).
Repairing of Main Canal Bed and Side walls from Ch. 85.00m -335.00m of Main Canal
Labour cost for dismantling of old CC canal lining and carriage of the materials and depositing the same in a safe distance as directed.
River sand filling in plinth, canal bed, canal slopes, bases of structure, etc in layers not more than 150 mm thick including necessary carriage, watering etc, complete as directed as specified.
Labour for preparation of subgrade of lined canal section as per design drawing and grade by ramming and rolled to level and according to the required cross section of the typical lined canal including cutting, filling the existing canal section where necessary compacting the earth in layers in not more than 15 cm thick to form a firm compacted bed & side for lining including watering to obtain required moisture content where necessary etc, complete as directed.
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
CC work in proportion 1:2:4 in foundation / abutment / piers / wing walls etc.with hard broken stone aggregate of size 6 mm to 20 mm including curing with necessary timber shuttering, scaffolding where necessary complete as directed.(Shuttering, scaffolding cost will be paid separately)
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works, complete as directed. (Measurement to be taken on the face area timbered).
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc,including racking out joints and curing etc, complete as directed.(i) In proportion 1:4
12 mm cement plastering including clearing surface and curing, complete as directed.(ii) In proportion 1:4
Cement pointing including racking out joints and curing etc, complete as directed.(i) In proportion 1:3
Labour for fitting and fixing hume pipe in position with collars including joining the cement mortar in proportion 1:3 and curing, including carrying the same from godown to site and complete as directed.(i) For 30 cm to 60 cm dia
Earthwork in filling in all soils in plinth, canal embankment and bed filling as per CuM Rs. 478.09 design section and grade by truck carriage for a minimum distance of 4 KM including paying compensation of earth obtained from private land if any loading, unloading, spreading the same including light jungle, removing trees upto 15 cm dia and uprooting roots and stumps etc. from the seat of the embankment, breaking clods not more than 10 mm cube, ramming, profiling etc. with all lift, complete as directed. (Payment will be made after deduction of 12.50 % shrinkage allowance from the gross quantity).
Repairing of Barge
REPAIRING OF BARGE:- Repairing of deck type barge of size 10.00 M x 5.00 M x 1.50 M. The Job includes necessary allied works such as dismentling of the damaged parts, supply and fabrication of the side and deck portion, supply fitting fixing of the super structure of the barge with roofing, shifting and floating of the barge , along with leakage testing, painting etc. complete as directed.
TRUSSESS , GI SHEETS, FLY PROOF WIRE GAUZE AND RAILING IN BARGE Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete , Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m² , Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.10.29.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides and Side Railing on Barge.
Supply and Installation of pumpset, supply of LT Main panel board, LT Sub panel board and Transformer sub station etc.
Supply and installtion of 60 HP pumpset
Rewinding of 60 HP induction motor
Repairng of 60 HP induction motor
Repairing and Overhauling of 60HP pumpset
Repaing of 60HP Starter
Construction of 315kVA 11kV/0.433kV Pad Mounted Sub station alongwith Supply & Erection of the transformer and all necesaary materials including Testing & Commisioning, Making all necessary payments to APDCL for Supervision/Meter Security etc. ( Except Laod Security) complete as directed & comprising of the following: 11kV/0.433kV transformer of appropiate rating, PSC Pole -9.75metre long to be erected with boulder packing, Support - G point l-Point channel cross arm 75mm x 50mmx 6mmx 2200mm for G.O., D.O.,etc, Insulators- i) 11kV polymeric disc insulator, for 5kN with neccesary hardware fitting & ii) 11kV polymeric pin insulator, 5kN, Cable XLPE -PVC insluated 1.1kV Grade armoured single core cable of suitable size (for connection from DTR terminal to feeder panel), Security fencing around the Sub-station plus earth filling , Lighting arrestor -3nos, C.I. Earth Pipe -7nos, Feeder panel with Cu busbar and 415V FP MCCB of suitable rating, G.O. 1 set and D.O. - 1 set , HT metering unit along with CT/PT set , B.) 315kVA S/S (DTR Cu wound as per CEA Guideline) (Cost of Pad of size 1.2M x 1.2M x 2.5M included)
Repairing of Overhead 11kV HT Line
Dismantling of existing faulty disc /pin insulator in 11kV HT line
Dismantling of existing ACSR/AAA Racoon Rabbit conductor
Supply & Erection of 11kV Polymeric pin insulator 5KN
supply, laying & erection of AAA Rabbit Conductor 7/3.15mm
LT Cabling
Supply & laying of 31/2 core PVC XLPE insulated Armoured LT power Cable 1.1kV Grade with AI conductor in existing open trench /in air includind fixing with necc. Clamps etc in wall/pole/ other support including End termination iwtyh brass comprssion Gland & cable lug as reqd. & as directed Size: 300sq.mmx 3.5 core
Supply & laying of 3 core PVC XLPE insulated Armoured LT power Cable 1.1kV Grade with AI conductor in existing open trench /in air includind fixing with necc. Clamps etc in wall/pole/ other support including End termination iwtyh brass comprssion Gland & cable lug as reqd. & as directed Size: 70sq.mmx 3 core
LT CABLE END TERMINATION
LT CABLE TERMINATION with brass compression glands and Al. lugs. Providing End Terminaation of PVC/XLPE insulated Al. conductor, armoured LT power cable, 1.1kV grade of following sizes with brass compression gland & Al. lugs along with supply of all materials as reqd. & as directed Size: 300sq.mmx 3.5 core
LT CABLE TERMINATION with brass compression glands and Al. lugs. Providing End Terminaation of PVC/XLPE insulated Al. conductor, armoured LT power cable, 1.1kV grade of following sizes with brass compression gland & Al. lugs along with supply of all materials as reqd. & as directed Size: 70sq.mmx 3 core
Miscellaneous items required for operation of 60 HP Pumset
Sri Babul Kumar Das
KULADIP BORAH
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .